0% found this document useful (0 votes)
265 views4 pages

F5C Uk

This document provides information on the F5C proportional throttle valve series from Parker Hannifin, including: - The F5C valve allows adjustable flow proportionate to an input signal and can provide load-compensated flow when used with pressure compensators. - The valve is available in sizes from 3/4" to 1-1/4" with maximum pressures up to 270 bar and flows up to 380 l/min. - Technical data, dimensions, characteristic curves and ordering information is given to specify the valve for a particular application.

Uploaded by

Jas Sum
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
265 views4 pages

F5C Uk

This document provides information on the F5C proportional throttle valve series from Parker Hannifin, including: - The F5C valve allows adjustable flow proportionate to an input signal and can provide load-compensated flow when used with pressure compensators. - The valve is available in sizes from 3/4" to 1-1/4" with maximum pressures up to 270 bar and flows up to 380 l/min. - Technical data, dimensions, characteristic curves and ordering information is given to specify the valve for a particular application.

Uploaded by

Jas Sum
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Catalogue HY11-3500/UK Proportional Throttle Valve

Characteristics Series F5C (Denison)

Proportional throttle valves series F5C allow to adjust


the flow in proportion to the input signal. The combina-
tion of the F5C with pressure compensators R5A or R5P
serves as a flow control valve - providing load compen-
sated flow.
The F5C is offered with two types of response time:
standard 350 ms at 1 l/min pilot flow
code A, faster 150 ms at 2 l/min pilot flow

Features
• Spool type proportional throttle valve
• SAE61 flange
• Maximum pressure 270 bar
• Maximum flow 380 l/min
• 3 sizes, SAE 3/4“, 1“, 1 1/4“
• Load compensated flow in combination with R5A
and R5P

F5C_UK.INDD RH

9-49 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-3500/UK Proportional Throttle Valve
Ordering Code Series F5C (Denison)

F5C 4 3 1 0 A

Pressure Nominal Pilot flow SAE61 Pilot Spool Proportional Pilot Accesso- Design Seals Options
relief valve size and interface ports type solenoid connection ries series
response G¼"

Code Nominal size Code Seals


06 SAE ¾" 1 NBR
08 SAE 1" 5 FPM
10 SAE 1¼"

F5C without F5C for com- F5C for com-


Max. Pilot connec-
Code Pilot flow Code compensators bination with bination with
response tions
R5A, R5P R5A R5P
omit 1 l/min 350 ms internal PD (Y) X1, X3, Y2
A 2 l/min 250 ms 2 internal PP (X) X2, Y1
X2, Y1
external PD (Y) X1, X3, Y2
Spool type 3 external PP (X) X2, Y1
Code Size Max. flow 1)
A 06 23 l/min external PD (Y) X3, Y2 X2, X3, Y1, Y2
B 06/08 45 l/min 4 external PP (X) X1 X1
1 06/08/10 95 l/min X2, Y1
2 08/10 190 l/min external PD (Y) X1, Y2
3 10 380 l/min 5 internal PP (X) X3
1)
At nominal pressure drop (∆p = 8.4bar) X2, Y1
external PD (Y) X1, X3 X1, X3
6 internal PP (X) X2, Y1 X2, Y1, Y2
Y2

* optional open closed closed by counterpart

F5C_UK.INDD RH

9-50 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-3500/UK Proportional Throttle Valve
Technical Data / Characteristic Curves Series F5C (Denison)

Technical data
General
Size 06 (¾") 08 (1") 10 (1¼")
Mounting Flanged according to SAE 61
Mounting position unrestricted
Ambient temperature [°C] -20...+50
Weight [kg] 3.9 4.1 5.8
Hydraulic
Max. operating pressure
Ports A, B, X1, X2, X3 [bar] 270
Ports Y1, Y2 [bar] 70
Max. pressure drop (from A to B) [bar] 21
Nominal flow [l/min] 95 190 380
Fluid Hydraulic oil as per DIN 51524...525
Fluid temperature [°C] -20...+80
Viscosity permitted [cSt] [mm2/s] 10...650
Viscosity recommended [cSt] [mm2/s] 30
Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Electrical characteristics
Duty ratio [%] 100
Solenoid connection Connector as per EN175301-803
Protection class IP65 in accordance with EN 60529 (plugged and mounted)
Supply voltage [V] 12
Current consumption [mA] 220
Resistance [Ohm] 60
Response time [ms] see ordering code
Coil insulation class H (180 °C)

Characteristic curves

F5C_UK.INDD RH

9-51 Parker Hannifin GmbH & Co. KG


Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-3500/UK Proportional Throttle Valve
Dimensions Series F5C (Denison)

l1 b1 h1 h2 h3 h4 h5 h6 d1 d2 d3
F5C06 47.6 60 68.2 26 22.2 103.2 119.2 20.8 19 10.5 G¼"
F5C08 52.4 60 73.6 29 26.2 108.6 124.6 24.3 25 10.5 G¼"
F5C10 58.7 75 83.5 36.5 30.2 118.5 134.5 29.3 32 12.5 G¼"