A COMPACT, FULLY AUTOMATED SOLUTION FOR HIGH
QUALITY CLINICAL CHEMISTRY TESTING
www.therxseries.com
          SYSTEM OVERVIEW
The RX daytona+ is a bench-top, fully automated, random access clinical chemistry analyser capable
of performing routine & specialised testing and emergency STAT sampling. With the world leading RX
series test menu, the RX daytona+ provides excellent opportunity for consolidation and is perfect for
use as a back up analyser in the larger laboratory.
REAGENT CAROUSEL                                           CUVETTES
                     Reagents cooling 8-15 °C                           72 reaction cuvettes (semi-permanant)
                     50 cooled positions for 20ml & 70ml                Cuvettes life-span: 3 – 6 Months
                     bottles
                                                                        Minimum reaction volume of 100µl
                     Automatic barcode for reagent
                     identification                                     Minimum reaction volume of 350µl
 Dual 5 Speed Stirrers
The RX daytona+ provides high quality testing on a compact, easy to use clinical chemistry analyser for
accurate results you can trust.
WASH STATION                                                SAMPLE CAROUSEL
                     12 stage washing process                                 Sample interruption for addition of
                                                                              emergency samples
                     Includes acid, alkali and pure water
                                                                              Barcode sample identification
                     wash steps
                     Stations 1 - 4 have liquid level                         100µl in standard or primary tubes -
                     sensors to prevent cuvette                               50µl in paediatric cups
                     overflows
                                                                                               Optional ISE unit
Fully automated chemistry analyser
270 photometric tests per hour and up to 450 including ISE
Reagent carousel with 50 cooled positions
Universal sample carousel with 40 positions and 10 control/calibrator positions
Low water consumption of just 5 litres per hour
Intuitive icon based user friendly software (Windows® 7)
Dual 5 speed stirrers optimised for each assay ensuring better performance
Storage of up to 30,000 patient reports with search facility
Liquid level, clot & crash detection
Unique emergency loading port allows emergency samples to be analysed
quickly and easily during run
Low reagent volume - R1: 20 - 250µl (1µl increments) R2: 20 -180µl
 (1µl increments) & sample volume of just 1.5µl (0.1µl increments)
Barcode readers for both sample and reagent identification
Why   ?
HIGHLY ACCURATE TESTING
•	 Separate sample and reagent pipettes minimise carryover
•	 Dedicated micropipettes are equipped with liquid level sensors and crash detection
•	 Dual five speed stirrers optimise mixing for each assay
•	 Serum indices detect lipaemic, icteric and haemolytic samples, building confidence in results and reducing the need for
   expensive repeats
EASE OF USE
•	 Easy to use Windows® based software
•	 Just one click opens the emergency sample ordering screen for rapid STAT testing
•	 Barcode readers for both sample and reagent identification
•	 Ability to register samples for routine measurement with an auto-template function
•	 Symbol based software for ease of use
SUPERIOR PERFORMANCE
•	 Sensitive clot detection sensor detects clots such as fibrin at the sample pipette
•	 72 cuvettes onboard with cuvette check function ensuring only clean and viable 	reaction vessels are reused
•	 Built in inventory management system automatically calculates remaining reagent volume and the number of tests available
OPTIMUM LABORATORY EFFICIENCY
•	 Low minimum reaction volume of 100µl improves cost-effectiveness and reduces waste
•	Automatic test re-run function saves time and reduces risk of human error
•	Automatic sample dilution
•	Automatic wake up and sleep functionality
TIME AND COST SAVINGS
•	 Minimal maintenance required
•	 Extensive menu allows consolidation of testing
•	 Economic platform with low water consumption of only 5 litres per hour
UNRIVALLED QC CAPABILITIES
•	 Generation of Levey-Jennings charts, calibration curves and QC statistics for reliable results
•	 View QC history
FLEXIBILITY
•	 12 wavelengths generated via diffraction grating: 340, 380, 415, 450, 510, 546, 570, 600, 660, 700, 750 and 800nm
•	 Capable of running monochromatic, bi-chromatic, endpoint, kinetic, ISE, sample blanking and reagent blanking assays
•	 7 different calibration option available including; Factor, Linear, Point to point, Log-logit, Exponential, Spline and Spline 2
EXTENSIVE DEDICATED TEST MENU
•	Wide range of tests available from a sole supplier, including routine and unique assays
•	Ability to run specific proteins removes the need for a separate nephelometry system
            TEST MENU
 CLINICAL
AUTOIMMUNE:                    Chloride                     Complement Component 3         NUTRITIONAL STATUS:
Complement Component 3         CO2 Total                    Complement Component 4         Albumin
Complement Component 4         Creatinine Enzymatic         Direct Bilirubin               Copper
CRP                            Creatinine (Jaffe)           Gamma GT                       Ferritin
CRP Full Range (0.3-160mg/l)   Glucose                      GLDH                           Iron
CRP High Sensitivity           Lactate                      Glycerol                       Iron (UIBC)
IgA                            Potassium                    Haptoglobin                    Lipase
IgE                            Sodium                       IgA                            Magnesium
IgG                            Total Bilirubin              IgG                            Potassium
IgM                            Total Protein                IgM                            TIBC
Rheumatoid Factor              Urea                         Iron (UIBC)                    Transferrin
                                                            LAP                            Transthyretin (Prealbumin)
BASIC METABOLIC PROFILE:       DIABETES:                    LDH                            Zinc
Calcium                        Adiponectin                  Total Bilirubin
CO2 Total                      Cholesterol                  Total Protein                  PANCREATIC FUNCTION:
Chloride                       Creatinine Enzymatic         Transferrin                    Amylase
Creatinine Enzymatic           Creatinine (Jaffe)           Transthyretin (Prealbumin)     Glucose
Creatinine (Jaffe)             Cystatin C                                                  LDH
Glucose                        Direct HDL Cholesterol       INFLAMMATION AND               Lipase
Potassium                      Direct LDL Cholesterol       INFECTION:                     Pancreatic Amylase
Sodium                         Fructosamine                 Alpha-1Acid Glycoprotein
Urea                           Glucose                      ASO                            RENAL FUNCTION:
                               Glycerol                     CRP                            Albumin
BONE PROFILE:                  HbA1c/Hb                     Lactate                        Ammonia
Alkaline Phosphatase           Microalbumin                 Rheumatoid Factor              Beta-2 Microglobulin
Calcium                        NEFA (Non-Esterified Fatty                                  Calcium
Phosphorus                     Acids)                       LIPIDS:                        Chloride
Total Protein                  Ranbut (Hydroxybutyrate)     Apolipoprotein A-1             Creatinine Enzymatic
                               Total Protein                Apolipoprotein AII             Creatinine (Jaffe)
CARDIAC:                       Triglycerides                Apolipoprotein B               Cystatin C
Cholesterol                    Urinary Protein              Apolipoprotein CII             Glucose
CK-MB                                                       Apolipoprotein CIII            HbA1c/Hb
CK-NAC                         ELECTROLYTES:                Apolipoprotein E               IgG
CRP                            Calcium                      Cholesterol                    LDH
CRP Full Range (0.3-160mg/l)   Chloride (Nondirect)         Direct HDL Cholesterol         Magnesium
CRP High Sensitivity           CO2 Total                    Direct LDL Cholesterol         Microalbumin
Digoxin                        Lithium                      Lipoprotein (a)                Potassium
Direct HDL Cholesterol         Magnesium                    sLDL                           Sodium
Direct LDL Cholesterol         Potassium (Nondirect)        Triglycerides                  Phosphorus (Inorganic)
H-FABP                         Sodium (Nondirect)                                          Urinary Protein
Homocysteine                                                NEONATAL SCREENING:            Urea
Lipoprotein (a)                HAEMOLYTIC ANAEMA:           Alpha-1 Antitrypsin            Uric Acid
Myoglobin                      G6P-DH                       CRP
sLDL                           Haptoglobin                  CRP Full Range (0.3-160mg/l)
Triglycerides                  LDH                          CRP High Sensitivity
TxB Cardio                                                  IgE
                               HEPATIC FUNCTION:            Transthyretin (Prealbumin)
COMPREHENSIVE                  Albumin
METABOLIC PROFILE:             Aldolase                     NEUROLOGICAL
Albumin                        Alkaline Phosphatase         DISORDERS (CSF):
Alkaline Phosphatase           Alpha-1 Antitrypsin          IgA
ALT                            ALT                          IgG
AST (GOT)                      Ammonia                      IgM
Direct Bilirubin               AST (GOT)
Calcium                        Cholinesterase
 VETERINARY
Albumin                           CK-NAC                         Lactate                           Total Protein
Alkaline phosphatase              CO2 Total                      Lactate dehydrogenase             Triglycerides
ALT (GPT)                         Copper                         LDL                               Urea
Aldolase                          Creatinine                     Lipase                            Uric Acid
Ammonia                           Canine CRP                     Magnesium                         Urinary protein
Amylase                           CRP                            NEFA (Non-esterified fatty        Zinc
AST (GOT)                         Fructosamine                   acids)
Bile acids                        Gamma-GT                       Phosphorus (Inorganic)
Bilirubin                         GLDH                           Potassium
Calcium                           Glucose                        Ranbut (Hydroxybutyrate)
Chloride                          Glycerol                       Ransel (Glutathione peroxidase)
Cholesterol                       HDL                            Ransod (Superoxide dismutase)
Cholinesterase (Butyryl)          Iron (UIBC)                    Sodium
 TOXICOLOGY
THERAPEUTIC DRUGS:                                               DRUGS OF ABUSE:
Acetaminophen                     Phenobarbitol                  Amphetamines                      Ecstasy
Carbamazepine                     Phenytoin                      Barbiturates                      EDDP
Digoxin                           Salicylate                     Benzodiazepines                   Ethanol
Gentamicin                        Theophyline                    Cannabinoids                      Methadone
Lithium                           Valproic Acid                  Cocaine metabolite                Opiates
 PROTEIN
SPECIFIC PROTEINS:
Alpha-1 Antitrypsin               ASO                            Cystatin C                        IgM
Alpha-1 Acid Glycoprotein         Beta-2 Microglobulin           Ferritin                          Lipoprotein (a)
Apolipoprotein A-1                Ceruloplasmin                  Fructosamine                      Microalbumin
Apolipoprotein AII                Complement Component 3         Haptoglobin                       Myoglobin
Apolipoprotein B                  Complement Component 4         HbA1c/Hb                          Rheumatoid Factor
Apolipoprotein CII                CRP                            IgA                               Transthyretin (Prealbumin)
Apolipoprotein CIII               CRP Full Range (0.3-160mg/l)   IgE                               Transferrin
Apolipoprotein E                  CRP High Sensitivity           IgG
 RESEARCH
ANTIOXIDANTS:                     FOOD AND WINE TESTING:         BIOTECHNOLOGY:                    SPECIALITY:
Albumin                           Acetic acid                    Glutamate                         Acid phosphatase
Bilirubin                         Ammonia                        Glutamine
Ferritin                          Copper
Glutathione Reductase             Ethanol
Ransel (Glutathione Peroxidase)   Glucose/fructose
Ransod (Superoxide Dismutase)     Lactic acid
TIBC                              Malic acid
Total Antioxidant Status          NOPA
Transferrin                       Potassium
Uric Acid                         TAS
                                  Total SO2
                                                        Software
The symbol based intuitive software allows easy access to information and control of operations from the
main screen with informative tabs
                                                      CALIBRATION
                                                      •	Sets calibrator serial dilution and displays multipoint
                                                        calibration curves
                                                      QUALITY CONTROL
                                                      •	Generation of Levey-Jennings charts, calibration curves
                                                        and QC statistics offer simple assessment of results
                                                      RUN MONITOR
                                                      •	Displays full patient demographics
                                                      •	View status in real time including time to completion
                                                      •	Indication of amounts of tests remaining
Calibration Screen
                                                      INVENTORY
                                                      •	Automatically calculates remaining reagent volume and
                                                        the number of tests available and stability
                                                      MAINTENANCE
                                                      •	5minutes minimal daily maintenance required
                                                      RESULTS
                                                      •	Download and print results
                                                      •	Send to host automatically
Inventory Screen
                     CHEMISTRY PARAMETERS
                     •	Enables sample dilution and test re-runs
                     •	Set up to 20 test profiles and define order of analysis
                     CONNECTIVITY
                     •	Software capable of connecting to LIMS system via ASTM
                       standard
                     EASY TO FOLLOW REPORTS
                     •	V
                        iew real time results status, including time to
                       completion
Parameter Screen
                     USER - FRIENDLY INTERFACE
                     •	Familiar Microsoft Windows® based software offers ease
                        of navigation
                     •	Intuitive symbol based software results in minimal training
                        requirements and enhanced productivity
Run Monitor Screen
           SPECIFICATIONS
PHYSICAL DIMENSION
Height   	                    625mm
Depth   	                     670mm
Length    	                   870mm
Weight     	                  120kg
PERFORMANCE CHARACTERISTICS
Throughput	                   270 tests per hour, 450 tests per hour with ISE	
Analyser Type	                Compact fully automated random access bench top clinical analyser
Assay Tests                   Monochromatic, bi-chromatic, endpoint, kinetic, sample and reagent blanking and ISE
Maintenance 	                 Daily maintenance-less than 5 minutes. No rear access required. Simple twice yearly 		
	                             preventative maintenance service.
REAGENT & SAMPLE SYSTEM
Data Management 	             Storage of up to 30,000 patient reports, search facility
Test Channels	                50 photometric channels, 3 direct ISE
Sleep mode	                   User defined sleep mode capabilities with automatic wash and instrument prep
Maintenance	                  Minimal daily maintenance. No rear access required. Simple twice yearly			
	                             preventative maintenance
Reagent Pipette	              Dedicated reagent micropipette with liquid level sensor and crash detection
Reagent Volume	               R1: 20 to 250µl (1µl increments)
	                             R2: 20 to 180µl (1µl increments)
Reagent Capacity	             Removable turntable with 50 cooled positions for 20ml and 70ml bottles
Reagent Cooling	              8 to 15°C
Reagent Identification	       Barcode reagent identification
Reagent Inventory	            Calculation of remaining reagent volume and tests available. Alert for shortage, expired
Sample Addition	              Sampling interruption for addition of samples
Sample Capacity	              Removable turntable with 40 positions for samples, calibrators and controls
Sample Dead Volume	           100µl in standard or primary tubes. 50µl in paediatric cups
Sample Dilution	              Pre-dilution and automatic re-assay with diluted, reduced or increased sample volume
Sample Identification	        Barcode sample identification
Sample Pipette	               Dedicated sample micropipette with liquid level sensor, crash protection and clot detection
Sample Tube size	             Multiple primary tube sizes (diameter 12 to 16mm, height 55 to 100mm) Paediatric cups
Sample Type	                  Serum, plasma, urine & supernatants
Sample volume	                1.5 to 35µl (0.1µl increments)
STAT Sampling	                STAT samples can be added immediately via emergency loading port
REACTION SYSTEM
Reaction Time	                10 minutes (R1: 5 min. + R2: 5 min.)
Reaction Volume	              100 to 350µl
Stirring Speed	               5 speed levels available
Stirring System	              Dual 5 speed stick type rotating stirrers
Temperature Control	          Dry bath
Water Consumption	            Maximum 5 litres per hour
Water Requirements	                 NCCLS type 1 or 2 purified water supply
Wash Unit	                          12 stage washing process
Cuvettes 	                          72 semi-permanent cuvettes
Incubator Temperature	              37°C ± 0.1°C
Cycle Time 	                        13 seconds
OPTICAL SYSTEM
Detector Method	                    Direct absorbance in cuvette (bi-chromatic and monochromatic)
Detection Principal	                12 wavelengths generated via diffraction grating: 340, 380, 415, 450, 510, 546, 570, 600, 	
	                                   660, 700, 750 and 800nm
ISE Unit	                           Optional ISE unit available
Light Source	                       Halogen tungsten lamp air cooled by fan
CALIBRATION & QC
Quality Control	                    Interactive Levey Jennings charts, daily, monthly and batch QC with data archiving. 		
	                                   Automatic QC and automatic calibration
Calibration Principal	              Factor, Linear, Point to point, Log-logit, Exponential, Spline and Spline 2
POWER & CONNECTIVITY
Power Requirement	             AC100V to 120V, 6.5A (Max.)
	                              AC200 to 230V, 3.3A (Max.)
	50/60Hz
Power Consumption	650VA
Permissable Voltage Variation	 ± 10% (Max.)
LIMS Connectivity	             Bi-directional ASTM Standard (RS232 connection)
OPERATING SYSTEM
Operator Interface                  Windows® based software
ORDERING INFORMATION
RX daytona plus analyser without ISE	RX4041
RX daytona plus analyser with ISE	RX4040
		
             A-Z TEST MENU
Acetaminophen                  Glucose/Fructose
Acetic Acid                    Glutamate
Acid phosphatase               Glutamine
Adiponectin                    Glutathione Peroxidase (Ransel)
Albumin                        Glutathione Reductase
Aldolase                       Glycerol
Alkaline Phosphatase           Haptoglobin
Alpha-1 Acid Glycoprotein      HbA1c/Hb
Alpha-1 Antitrypsin            HDL Cholesterol (Direct)
ALT                            Heart-Type Fatty Acid Binding Protein (H-FABP)
ALT (GPT)                      Homocysteine
Ammonia                        Hydroxybutyrate (Ranbut)
Amphetamines                   IgA
Amylase                        IgE
Apolipoprotein A-1             IgG
Apolipoprotein AII             IgM
Apolipoprotein B               Iron
Apolipoprotein CII             Lactate
Apolipoprotein CIII            LAP
Apolipoprotein E               LDH
ASO                            LDL Cholesterol (Direct)
AST (GOT)                      Lipase
Barbiturates                   Lipoprotein (a)
Benzodiazepines                Lithium
Beta-2 Microglobulin           L-Lactic Acid
Bile Acids                     Magnesium
Bilirubin (Direct & Total)     Malic Acid
Calcium                        Methadone
Canine CRP                     Microalbumin
Cannabinoids                   Myoglobin
Carbamazepine                  NEFA (Non-Esterified Fatty Acids)
Ceruloplasmin                  Opiates
Chloride (Non-Direct)          Pancreatic Amylase
Cholesterol                    Phenobarbitol
Cholinesterase                 Phenytoin
Cholinesterase (Butyryl)       Phosphorus
CK-MB                          Potassium (Non-Direct)
CK-NAC                         Rheumatoid Factor
CO2 Total                      Salicylate
Cocaine metabolite             sLDL
Complement Component 3         Sodium (Non-Direct)
Complement Component 4         Superoxide Dismutase (Ransod)
Copper                         Theophyline
Creatinine (Jaffe)             TIBC
Creatinine Enzymatic           Total Antioxidant Status
CRP                            Total Protein
CRP Full Range (0.3-160mg/l)   Transferrin
CRP High Sensitivity           Transthyretin (Prealbumin)
Cystatin C                     Triglycerides
Digoxin                        TxB Cardio
Ecstasy                        Urea
EDDP                           Uric Acid
Ethanol                        Urinary Protein
Ferritin                       Valproic Acid
Fructosamine                   Zinc
G-6-PDH
Gamma GT
Gentamicin
GLDH
Glucose
The RX series has been developed by Randox to meet the growing needs of clinical laboratory testing. Robust hardware
combined with intuitive software ensures exceptionally low downtime with unrivalled precision and accuracy for results
you can trust.
                                          RX monza
                                          The RX monza is a compact semi-automated analyser with astonishing
                                          functionality, offering 192 channels, 79 of which have dedicated parameters.
                                          The RX monza will open exciting opportunties for both routine and specialised
                                          testing including coagulation testing.
                                          RX monaco
                                          The RX monaco is a fully automated random access clinical analyser capable
                                          of carrying out 170 tests per hour. It provides unrivalled performance for low
                                          to mid volume testing.
                                          RX daytona+
                                          Superior performance for mid volume laboratories. The RX daytona+ is
                                          capable of running 270 photometric tests per hour or 450 tests per hour
                                          including ISEs.
                                          RX imola
                                          Efficiency for medium sized laboratories. The RX imola is a random access
                                          benchtop clinical analyser with a throughput of 560 tests per hour including
                                          ISEs.
                                                                                                         International Headquarters
                                      Randox Laboratories Limited, 55 Diamond Road, Crumlin, County Antrim, United Kingdom, BT29 4QY
                                      T +44 (0) 28 9442 2413                            F +44 (0) 28 9445 2912                           E marketing@randox.com                            I www.randox.com
                              Australia                                                      Brazil                                                     China                                                     Czech Republic
                     Randox (Australia) Pty Ltd.                                      Randox Brasil Ltda.                                      Randox Laboratories Ltd.                                     Randox Laboratories S.R.O.
                      Tel: +61 (0) 2 9615 4640                                      Tel: +55 11 5181-2024                                      Tel: +86 021 6288 6240                                         Tel: +420 2 1115 1661
                               France                                                     Germany                                                    Hong Kong                                                         Italy
                       Laboratoires Randox                                      Randox Laboratories GmbH                              Randox Laboratories Hong Kong Limited                                  Randox Laboratories Ltd.
                     Tel: +33 (0) 130 18 96 80                                  Tel: +49 (0) 2151/93 706-11                                    Tel: +852 3595 0515                                            Tel: +39 06 9896 8954
                              India                                                     Poland                                                       Portugal                                                     Puerto Rico
                Randox Laboratories India Pvt Ltd.                         Randox Laboratories Polska Sp. z o.o.                    Irlandox Laboratorios Quimica Analitica Ltda                   Clinical Diagnostics of Puerto Rico, LLC
                     Tel: +91 22 6714 0600                                       Tel: +48 22 862 1080                                         Tel: +351 22 589 8320                                          Tel: +1 787 701 7000
                         Republic of Ireland                                               Slovakia                                                 South Africa                                                    South Korea
                           Randox Teoranta                                               Randox S.R.O.                                   Randox Laboratories SA (Pty) Ltd.                                         Randox Korea
                        Tel: +353 7495 22600                                        Tel: +421 2 6381 3324                                    Tel: +27 (0) 11 312 3590                                        Tel: +82 (0) 31 478 3121
                                Spain                                                  Switzerland                                                       USA                                                     Vietnam
                      Laboratorios Randox S.L.                            Randox Laboratories Ltd. (Switzerland)                             Randox Laboratories-US, Ltd.                             Randox Laboratories Ltd. Vietnam
                       Tel: +34 93 475 09 64                                     Tel: +41 41 810 48 89                                          Tel: +1 304 728 2890                                      Tel: +84-8-39 11 09 04
                                           Randox Laboratories Ltd, 55 Diamond Road, Crumlin, County Antrim, United Kingdom, BT29 4QY
                                             T +44 (0) 2894422413 F +44 (0) 2894452912 E marketing@randox.com I www.randox.com
                                                                                                                                                                                                                                              LT365JUN14
Information correct at time of print.
Randox Laboratories Limited is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151 6827 08. Product
availability may vary from country to country. Please contact your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA