BS-480 Chemistry Analyzer
BS-480 Chemistry Analyzer
                                                    Robust hardware
 Enhanced Liquid System
 Reagent and sample aspiration with extreme
 accuracy and precision
 Air bubble will be eliminated prior to washing
 High pressure interior probe wash
 Carry-over <0.05%
 Economy Usage
 Light-Spot Flatting Technology – an enhanced
 optical system facilitates lower reaction volume
 24 hours non-stop refrigeration at 2-10°C
 Minimum sample volume: 1.5 μl
 Reagent volume: 10 ~ 350 μl
 Easy to perform maintenance
 All containers & maintenance kits are located in
 the front of the analyzer
 Easily accessible for part replacement, routine
 maintenance or troubleshooting
 Step-by-step maintenance guide built in the
 software design
 Intelligent functions and smart
 protection                                                           Tailor made
 Support 4 reagents (R1, R2, R3 & R4)
 Vertical and horizontal collision protection
 Automatic System Recovery upon collision
 Liquid level detection, clot detection
                 Advanced software
                                     User-friendly Interface
                                     Uniform platform of BS-2000 series, BS-800 series,
                                     BS-480 and future instrument
                                     Real-time status monitoring between analytical
                                     unit and carousels
                                     Bi-directional LIS interface transmission
                                     Real-time QC Status Monitoring
                                     Westgard Rules and Two-Control Evaluation
                                     Levy-Jennings chart and Twin-Plot chart
                                     Real-time alarm when QC result(s) is out of range
                                     Auto QC setup capability
                                     Traceable Test Results
                                     Reagent, calibrator and control data can be
                                     recalled from archive history
                                     User-friendly, intuitive software design, easy
                                     to recall from historical results
                                     Reflex Function
                                     Pre-defined reflexive assays will be performed
                                     automatically when preset criteria is met
                                     Each assay may involve multiple reflexive criteria
                                     Each criteria may initiate up to a maximum of
                                     20 relevant assays
                                     Test Summary
e for your lab                       Test summary report calibration, QC, sample,
                                     validation test and rerun tests can be generated
                                     Facilitate computation of total test costs
                                     Error Log Export function -facilitate error report
                                     to engineers
                                     Results Archive can be transferred to engineers
                                     for evaluation
 Accurate, Reliable Results
 To ensure accuracy, reliability and correlation of diagnostic data, Mindray utilizes
 the International Standard in result reporting. To assure ease of report retrieving,
 Mindray establishes the Mindray Clinical Chemistry Measurement System for
 result traceability.
 Standard reference system
 Adopt JCTLM reference system
 IFCC primary method for enzyme, ID/MS method for substrate
 NIST, IRMM reference materials
 JCTLM, Joint Committee On Traceability In Laboratory Medicine
 NIST, National Institute of Standards and Technology,USA
 IRMM, Institute for Reference Materials and Measurements,EU
 IFCC, International Federation of Clinical Chemistry and Laboratory Medicine
 Complete traceability process                                                    Proficiency testing for reference measurement
 Complete calibration hierarchy and traceability chain based on                   Participate RELA (External quality control for reference laboratory)
 ISO standard (EN/ISO17511) from reference system to routine                      to verify the accuracy of the value assignment procedure.
 measurement system
    Traceability chain of Mindray measurement system (Glu)
                            Calibration /
Traceability   Material                      Procedure Implentation Uncertainty
                            Value Assignment
                                                                     Uc(y)
                             SI unit,mmol/L
     Reference material                       Primary Reference
     SRM 917C                                 measurement procedure
     Mindray Master                           CDC Hexokinase
     Calibrator                               reference method
     Mindray Product                          Mindray standard
     Calibrator                               Measurement system
                                              End user’ Routine                                                                               Mindray
     Routine Sample
                                              Mindray
                                Result
International standardization certification
International Standardization certificates of Cholesterol and HbA1c from CRMLN and NGSP.
More information refers to website (http://www.cdc.gov).
CRMLN (Cholesterol Reference Method of Laboratory Network)
NGSP(National glycosylated hemoglobin standardization program)
Matched calibrators and controls
Dedicated calibrators with traceability and specific target value
Convenient design of multi items of calibrators and controls combined into one vial
Long shelf life of lyophilized powder
Dedicated, high-quality reagents
Diagnostic function test panels
Test panels such as : Hepatic panel, renal panel, pancreatic panel, lipid panel, cardiac
panel, diabetic panel, rheumatic factor panel
Reliable analysis performance
EP series standard (CLSI)-evaluate and optimize reagent system for reliable performance
in precision, linearity, stability, specificity and anti-interference capability
ISO standard manufacturing
Mindray follows straightly the ISO certified manufacturing process to ensure every lot of
reagent in production is of supreme quality
Reagent Menu
Enzymes                                         Substrates
Alanine Aminotransferase (ALT)                  Total Cholesterol (TC)
Aspartate Aminotransferase (AST)                Triglycerides (TG)
Alkaline Phosphatase (ALP)                      HDL-Cholesterol (HDL-C)
γ-Glutamyl Transferase (γ-GT)                   LDL-Cholesterol (LDL-C)
α-Amylase (α-AMY)                               Apolipoprotein A1 (ApoA1)
Lactate Dehydrogenase (LDH)                     Apolipoprotein B (ApoB)
Lipase (LIP)                                    Direct Bilirubin (D-Bil) DSA
Cholinesterase (CHE)                            Direct Bilirubin (D-Bil) VOX
Adenosine deaminase (ADA)                       Total Bilirubin (T-Bil) DSA
α-L-fucosidase (AFU)                            Total Bilirubin (T-Bil) VOX
5'-nucleotidase (5'-NT)                         Total Protein (TP)
Creatine Kinase (CK)                            Albumin (ALB)
Creatine Kinase-MB (CK-MB)                      Total Bile Acids (TBA)
α-Hydroxybutyrate Dehydrogenase (α-HBDH)        Glucose (Glu) GOD-POD
Glucose-6-phosphate dehydrogenase (G6PD) *      Glucose (Glu) HK
Angiotensin converting enzyme (ACE) *           Urea (UREA)
D3-hydroxybutyric acid (D3-HB) *                Creatinine (CREA) Modified Jaffé
                                                Creatinine (CREA) Enzymatic
Specific Proteins                               Uric Acid (UA)
Immunoglobulin A (IgA)                          Carbon dioxide (CO2)
Immunoglobulin G (IgG)                          Fructosamine (FUN)
Immunoglobulin M (IgM)                          Hemoglobin A1c (HbA1c)
Immunoglobulin E (IgE) *                        Cystatin C (CysC)
Complement C3 (C3)                              Microalbumin
Complement C4 (C4)                              β2-Microglobulin (β2-MG) *
C-Reactive Protein (CRP)
Lipoportein(a) [LP(a)]                          Inorganic ions
Prealbumin (PA)                                 Calcium (Ca)
High sensitivity C-reactive protein (hs-CRP)    Magnesium (Mg)
Rheumatoid Factor (RF)                          Phosphate Inorganic (P)
Antibodies Against Streptolysin O (ASO)         Iron (Fe)
Homocysteine (HCY)
Ferritin (FER)                                  Electrolytes/ISE
Transferrin (TRF)                               Chloride(Cl)
Total iron binding capacity /                   Potassium(K)
unsaturated iron Binding capacity (TIBC/UIBC)   Sodium(Na)
Myoglobin*
D-dimer*
Retinol binding protein (RBP) *
* Coming soon
Mindray solution for clinical chemistry
                                                           Robust
                                                          hardware
                     Mindray
                     solution
                         for
                      clinical
                    chemistry
                                                                             Advanced
                                                                              software
                                         Dedicated
                                       reagent system
Mindray can now provide 60 parameters of dedicated reagents (more than 8 others are coming), covering
hepatic, renal, cardiac, lipids, diabetes, pancreatitis, inorganic ions and immunalassays, etc.,together with
original calibrators with metrological traceability as well as controls for BS-480 chemistry analyzer.
BS-480 Chemistry Analyzer
Technical Specifications
System function                                                                         Reaction System
Fully automated, discrete, random access,                                               Reaction rotor: Rotating tray, 90 cuvettes with automatic washing
STAT, urine and homogeneous immunoassays;STAT sample priority                           Cuvette:         Optical length 5mm
Throughput:       400 photometric tests/hour, up to 240 tests/hour for ISE              Reaction volume: 120~360µl
Measuring principles: Absorbance Photometry, Turbidimetry                               Operating temperature: 37°C
Methodology:      End-point, Fixed-time, Kinetic, optional ISE                          Temperature fluctuation: ±0.1°C
                  Single/Dual/Triple/Quadruple reagent chemistries,                     Mixing system: 2 independent mixers
                  Monochromatic/Bichromatic
Programming:      User defined profiles and calculation                                 Optical System
                                                                                        Light Source:   Halogen-tungsten lamp
Sample Handling                                                                         Photometer:     Reversed optics, grating photometry
Sample tray:       90 positions for primary or secondary tubes and sample cups          Wavelength:     340nm, 380nm, 412nm, 450nm, 505nm, 546nm,
Sample volume:     1.5~45 µl, step by 0.1µl                                                              570nm, 605nm, 660nm, 700nm, 740nm, 800nm
Sample probe:      Liquid level detection, clot detection and collision protection      Absorbance range: 0~3.3Abs (10mm conversion)
Probe cleaning:    Interior and exterior automatic probe washing                        Resolution:     0.0001Abs
                   carry-over < 0.05%
                   Automatic sample dilution, Pre-dilution and post-dilution            Control and Calibration
                   Dilution with ratio up to 1: 150                                     Calibration mode: Linear (one-point, two-point and multi-point),Logit
Dilution vessel:   Cuvette                                                                                -Log 4P, Logit-Log 5P, Spline, exponential, Polynomial,
                                                                                                          Parabola
Internal bar code reader (optional)                                                     Control rules:    Westgard multi-rule, Levy-Jennings, Cumulative sum
Sample/Reagent barcode reading – applicable to various bar code systems                                   check, twin plot
including Codabar, ITF (Interleaved Two of Five), code128, code39,
UPC/EAN, Code93; Bi-directional LIS Interface transmission                              Operation Unit
                                                                                        Operation system: Window XP Professional or
ISE Module (optional)                                                                                    Windows 7 Professional (32bit)
Optional selection of K+, Na+, Cl-                                                      Interface:        RS-232, Network Port, USB/ parallel port
Throughput:        Up to 240 tests per hour
                                                                                        Working Conditions
Reagent Handling                                                                        Power Supply:    200~240V, 50/60Hz, 1500VA
Reagent tray:    80 positions in refrigerated compartment (2~10°C)                                       or 110~130V, 60Hz, 1500VA
Reagent volume: 10~350µl                                                                Temperature:    15~30°C
Reagent probe: Liquid level detection, collision protection and                         Humidity:        35~85%
                 inventory check                                                        Water consumption: ≤20L/hour, De-ionized water
Probe cleaning: Interior and exterior automatic probe washing                           Dimension:       1180mm x 710mm x 1150mm (W x D x H)
                                                                                        Weight:          300 Kg
                                                             P/N:ENG-BS-480-210285x8-20131010