0% found this document useful (0 votes)
55 views2 pages

Structural Beam Design Guide

This document provides design specifications and calculations for reinforcing a 200x300mm concrete beam with a 4m span. Key details include: - The beam is analyzed as singly reinforced based on its maximum moment capacity of 64.61kN-m exceeding the applied load of 38.15kN-m. - The required steel reinforcement includes 5 bars of 16mm diameter in tension and 9 bars of 12mm diameter in compression. - Calculations determine the steel ratios and amounts based on material properties like yield strength and concrete compressive strength.

Uploaded by

KULOT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views2 pages

Structural Beam Design Guide

This document provides design specifications and calculations for reinforcing a 200x300mm concrete beam with a 4m span. Key details include: - The beam is analyzed as singly reinforced based on its maximum moment capacity of 64.61kN-m exceeding the applied load of 38.15kN-m. - The required steel reinforcement includes 5 bars of 16mm diameter in tension and 9 bars of 12mm diameter in compression. - Calculations determine the steel ratios and amounts based on material properties like yield strength and concrete compressive strength.

Uploaded by

KULOT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

B3

Design Specs
dbot = 74 say 90
Beam Size = 200 x 300 fy = 230
Beam Span = 4 m fc' = 27
Liveload = 1.9 KN d = 210
Slab = 3 KN/m2 α = 96.78
Side of Slabs = 1 sides d' = 75
Wt of Beam = 1.44 KN/m
Wt of Partition = 7.32 KN/m
m = 0.500
l = 4
s = 2

Design
A Load Analysis;
W = 7.43 KN/m2

We = 6.81 Kn/m

Wu = 19.07 Kn/m

Mu = 38.15 Kn-m

B Verify if Singly or Doubly Reinforced

ρmax = 0.75((.85^2*fc'/fy)(600/(600+fy))

ρmax = 0.0460

ρb = As/bd ----------> ρmax = Asmax/bd

Asmax = 1931.33 mm2

Max moment Capacity

Mu = 64.61 Kn-m

Applied Load Ultimate Load


38.15 64.61

Required Strength < Design Strength

Therefore; Analyze as Singly Reinforced Beam

C As1 = Asmax = 1931.33 mm2

Mu2 = -26.46 Kn-m excess load

c = 113.86 mm2

Extra Steel (As2)

As2 = -946.87 mm2

Tension Bars

As = As1 + As2
As = 984.46 mm2

Compression Bar
fs' = 204.76

fs' > fy therefore; Steel will not yeild

use fs' = fy = 230 Mpa

As'fs' = As2fy

As' = -946.87 mm2

Number of Rebars

Tension Bars use 16 mm deform bar

no of bars = 4.90
say 5 pcs - 16 mm deform bar

Compression Barsuse 12 mm deform bar

no of bars = -8.37
say -9 pcs - 12 mm deform bar

Therfore: USE 200 X 300 R.C. BEAM


with 5 pcs 16 mm Tension deform bar
and -9 pcs 12 mm Compression deform bar