Skip to content

andyed/pupil-lfhf

Repository files navigation

pupil-lfhf

Real-time LF/HF pupillometric cognitive load measurement via Butterworth IIR filters.

Based on Duchowski (2026): two 4th-order Butterworth filters split the pupil diameter signal into low-frequency (0-1.6 Hz, tonic/autonomic) and high-frequency (1.6-4 Hz, phasic/cognitive) bands. The LF/HF power ratio indexes cognitive load with a 1-second minimum window — 7.5x shorter than DWT-based approaches.

Usage

from pupil_lfhf import PupilLFHF

# Batch processing (offline, zero-phase)
detector = PupilLFHF(fs=150)
ratio = detector.compute(pupil_signal)  # single LF/HF value

# Per-segment (e.g., per-event cognitive load)
lf_signal, hf_signal = detector.filter(pupil_signal)
# Then compute variance ratio on any segment of interest

# Streaming (real-time, sample-by-sample)
detector = PupilLFHF(fs=150, mode='stream')
for sample in pupil_stream:
    ratio = detector.update(sample)  # None until buffer fills

Validation

validation/ contains empirical validation on the AdSERP dataset (2,719 eye-tracking trials, 150 Hz Gazepoint GP3 HD, Latifzadeh et al. SIGIR 2025):

  • Three-method convergence (Butterworth, DWT, raw PD agree on direction)
  • Per-position cognitive load trajectory during SERP evaluation
  • Head-to-head sensitivity comparison against trial-level LHIPA on 5 known effects

See validation/README.md for details.

Parameters

Parameter Default Description
fs 60 Sampling rate (Hz)
order 4 Butterworth filter order
lf_cutoff 1.6 LF band upper cutoff (Hz)
hf_band (1.6, 4.0) HF band (Hz)
power_window 1.0 Sliding window for variance (seconds, streaming mode)

Minimum windows

From Duchowski (2026), minimum signal duration for stable LF/HF estimation:

Method Minimum At 60 Hz At 150 Hz
FFT 10 s 600 samples 1,500 samples
DWT 7.5 s 450 samples 1,125 samples
Butterworth 1 s 60 samples 150 samples

References

Duchowski, A. T. (2026). Real-Time Cognitive Load Measurement of Pupillary Oscillation. Proc. ACM Comput. Graph. Interact. Tech. 9, 2. https://doi.org/10.1145/3803537

Duchowski, A. T., Krejtz, K., Gehrer, N. A., Bafna, T., & Baekgaard, P. (2020). The Low/High Index of Pupillary Activity. CHI '20. https://doi.org/10.1145/3313831.3376394

License

MIT

About

Real-time LF/HF pupillometric cognitive load via Butterworth IIR filters (Duchowski 2026). Includes AdSERP validation on 2,719 eye-tracking trials.