You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Verify EFRAC and IERR are acceptable values when GLOW is run. #45
The ETRANS error code IERR and energy conservation ratio EFRAC
should be checked for normal return. IERR should equal zero; if it doesn't
it means that the total inelastic cross section is near zero somewhere, which
is usually caused by a near zero ambient electron density. EFRAC should be
less than ~0.03 for photoelectron calculations, and less than ~0.1 for aurora.
It can get up to the 0.1-0.2 range in the twilight, which is not good, but at
present unavoidable.
Activity
mattzett commentedon Dec 15, 2020
What is efrac? Something like the flux through the bottom of the grid?
guygrubbs commentedon Dec 3, 2024
The ETRANS error code IERR and energy conservation ratio EFRAC
should be checked for normal return. IERR should equal zero; if it doesn't
it means that the total inelastic cross section is near zero somewhere, which
is usually caused by a near zero ambient electron density. EFRAC should be
less than ~0.03 for photoelectron calculations, and less than ~0.1 for aurora.
It can get up to the 0.1-0.2 range in the twilight, which is not good, but at
present unavoidable.