Your hyphen/dash is escaped as it needs to be so that's good.
If you haven't yet, it would be advisable to temporarily trim down your regex past the ${Device} until you're able to get that part capturing correctly. And from there continue to add portions of the regex back until it misbehaves again.
What platform and device is this output from?
Without a copy of your template and a (sanitized) copy of your raw output there's not much to help with.
@tuobi555 Your hyphen/dash is escaped as it needs to be so that's good.
If you haven't yet, it would be advisable to temporarily trim down your regex past the ${Device} until you're able to get that part capturing correctly. And from there continue to add portions of the regex back until it misbehaves again.
What platform and device is this output from? Without a copy of your template and a (sanitized) copy of your raw output there's not much to help with.
Hello @tuobi555
Ah, this is Huawei VRP.
There are quite a few command outputs in that 5 MByte cs01.txt file.
💡 Rather than parse a mountain of output with a single template, it would be better to create a template per command. (And some of the work may already exist over at ntc-templates [hyperlink below].)
From your screenshots I figure you are intending to parse "environmental" related items (Fans, etc). This appears to be the display device command.
Your template
Value List Device (\w+\W?\w+\W?\w+)
Value List Device_state (\w+)
Start
^[\w]{1,4}\s+\-\s+${Device}\s+\S+\s+\S+\s+\S+\s+${Device_state}\s+\S+\ *$$
Regarding the template, instead of two lists, why not capture multiple dictionaries of the two pairs {device, device_state}?
The benefit here is the ability to loop over a list of dictionaries and access both values more easily than having to "track" and access the index across the second list. (Example at the end of this post.)
Your raw CLI output
<ABCDEFG_HIJ_cs01>display device
CE12808S's Device status:
-------------------------------------------------------------------------------------------
Slot Card Type Online Power Register Alarm Primary
-------------------------------------------------------------------------------------------
3 - CE-L24LQ-EC1 Present On Registered Normal NA
4 - CE-L24LQ-EC1 Present On Registered Normal NA
6 - CE-L24LQ-EC1 Present On Registered Normal NA
7 - CE-L24LQ-EC1 Present On Registered Normal NA
8 - CE-L48XS-EC Present On Registered Normal NA
9 - CE-MPUA-S Present On Registered Normal Master
10 - CE-MPUA-S Present On Registered Normal Slave
11 - CE-SFUC-S Present On Registered Normal NA
12 - CE-SFUC-S Present On Registered Normal NA
13 - CE-SFUC-S Present On Registered Normal NA
14 - CE-SFUC-S Present On Registered Normal NA
15 - CMU(MPU 9) Present On Registered Normal Master
16 - CMU(MPU 10) Present On Registered Normal Slave
PWR1 - PHD-3000WA Present On Registered Normal NA
PWR2 - PHD-3000WA Present On Registered Normal NA
PWR3 - PHD-3000WA Present On Registered Normal NA
PWR4 - PHD-3000WA Present On Registered Normal NA
FAN1 - FAN-600A-B Present On Registered Normal NA
FAN2 - FAN-600A-B Present On Registered Normal NA
FAN3 - FAN-600A-B Present On Registered Normal NA
FAN4 - FAN-600A-B Present On Registered Normal NA
FAN5 - FAN-600A-B Present On Registered Normal NA
FAN6 - FAN-600A-B Present On Registered Normal NA
-------------------------------------------------------------------------------------------
A template for huawei_vrp display device does not yet exist over at ntc-templates, but I'll assist and we can make that happen. If I do that I'd plan to capture most if not all the columns of data.
@mjbear
Indeed, following your suggestions would be much easier. As a novice in DevOps, I lack experience and my coding skills are not strong. My initial idea was to use a single TextFSM template to extract everything, so that it could directly generate a JSON and then transfer it to Excel for convenient data analysis. If it were to be split up now, with each command having its own template, I would have to find a way to integrate the data in the code. Fortunately, I now have AI assistance; otherwise, it would take me several months with my abilities. Thank you all for your enthusiastic help. However, I am still curious why my writing style, it does not recognize the '-'.
@tuobi555
No worries, we all start somewhere and learn new things every day.
Ah, I was thinking you might have been using a library such as Paramiko/Netmiko to connect to the device and pull output which you were then parsing with TextFSM.
It may be necessary to "anchor" the regexes to make them more rigid -- loose regexes can match in situations where you don't want them to.
Combining the structured output (from TextFSM) into a single object or output file wouldn't be too difficult.
Does the display device output really differ from what you provided where the slot is sometimes not present in the leftmost "column"?
<HUAWEI> display device
Device status:
--------------------------------------------------------------------------------------
Slot Card Type Online Power Register Alarm Primary
--------------------------------------------------------------------------------------
1 - CE6850-48S4Q-EI Present On Registered Normal Master
FAN2 FAN-40SA-B Present On Registered Normal NA
PWR2 W1PA04BF0 Present On Registered Normal NA
--------------------------------------------------------------------------------------
AS02.log @mjbear The CE6800 series, CE128, and CE168 series, although all referred to as the CE series, have some differences in the distribution of display content. Moreover, the hardware configuration of my current environment is the same, and I am unable to provide sample data that shows the differences. Currently, there is also a CE68 series at the access layer available for your reference. I am very grateful to the enthusiastic friends for their help.
💡 Retrieving one large blob/string of commands from a device and parsing it with a single template is asking for difficulty. You should retrieve and parse command output individually (one command at a time) to simplify your problem.
❓ How are you retrieving your command output?
❓ Are you doing this via a programming language and/or automation software?
❗ There are some syntactically incorrect commands given the output saying Error: Unrecognized command found at '^' position.
❓ It doesn't make sense to parse both the output of display vlan and display vlan brief. Wouldn't the normal vlan output contain everything as brief and more? (Same situation with display stp and display stp brief as well as display ospf lsdb and display ospf lsdb router and so on.)
❗ Wow, this is around 116 commands in one blob (cs01), which is when I stopped compiling my list below.
@tuobi555
Would you be able to get sanitized output for display device elabel and put it in a code block in your response?
(put X's in for your barcode, serial number, and any other sensitive information)
@mjbear "Of course, that's fine. Initially, I just wanted to use this method to help me monitor the status of the equipment. As long as the requirements are met, it doesn't matter. Additionally, for the CE series devices, if you want to view the device's own serial number, the command should be 'display esn'. For other series, the commands might be 'display device manufacture-info' or 'display elabel slot slot-id', where 'slot-id' is the slot number of the corresponding device."
@tuobi555
You didn't say whether you're using Python, but regardless of the programming language it's simple to have a script loop through a list of commands and retrieve output from your VRP device.
I don't have access to any Huawei VRP devices. I'm trying to help you so that's why I need you to provide output.
Please provide output for display device elabel (put X characters in for the serial number and anything else sensitive).
If you like, I can look at your long template file but you'll need to share it.
@mjbear "The information I provided earlier was all the data I had collected. If there is no output for 'esn' in it, then there's nothing more that can be done. I also cannot casually take log files from my workplace. Thank you for your enthusiastic help. Of course, you can also share the command parsing templates that have already been made, so that more people can enjoy the convenience."
@mjbear "The information I provided earlier was all the data I had collected. If there is no output for 'esn' in it, then there's nothing more that can be done. I also cannot casually take log files from my workplace. Thank you for your enthusiastic help. Of course, you can also share the command parsing templates that have already been made, so that more people can enjoy the convenience."
@tuobi555
Ok, I'm guessing there could be some misunderstanding or mistranslation occurring.
I'm not asking for sensitive or confidential data.
Output could come from a lab device that is not in production or mask the potentially "sensitive data" with other characters or words. But I won't push the subject as I have a feeling this isn't going much further.
The template I created covers three display device commands since their output was similar. The new template details can be found at ntc-templates PR#1804.
Activity
mjbear commentedon Jul 24, 2024
@tuobi555
Your hyphen/dash is escaped as it needs to be so that's good.
If you haven't yet, it would be advisable to temporarily trim down your regex past the
${Device}until you're able to get that part capturing correctly. And from there continue to add portions of the regex back until it misbehaves again.What platform and device is this output from?
Without a copy of your template and a (sanitized) copy of your raw output there's not much to help with.
tuobi555 commentedon Jul 25, 2024
cs01.txt
textfsm.txt
mjbear commentedon Jul 26, 2024
Hello @tuobi555
Ah, this is Huawei VRP.
There are quite a few command outputs in that 5 MByte cs01.txt file.
💡 Rather than parse a mountain of output with a single template, it would be better to create a template per command. (And some of the work may already exist over at ntc-templates [hyperlink below].)
From your screenshots I figure you are intending to parse "environmental" related items (Fans, etc). This appears to be the
display devicecommand.Your template
Regarding the template, instead of two lists, why not capture multiple dictionaries of the two pairs {device, device_state}?
The benefit here is the ability to loop over a list of dictionaries and access both values more easily than having to "track" and access the index across the second list. (Example at the end of this post.)
Your raw CLI output
A template for
huawei_vrp display devicedoes not yet exist over at ntc-templates, but I'll assist and we can make that happen. If I do that I'd plan to capture most if not all the columns of data.How's this sound? 😀
Example on the list vs dictionary:
Versus
mjbear commentedon Jul 26, 2024
Teaser
tuobi555 commentedon Jul 26, 2024
@mjbear
Indeed, following your suggestions would be much easier. As a novice in DevOps, I lack experience and my coding skills are not strong. My initial idea was to use a single TextFSM template to extract everything, so that it could directly generate a JSON and then transfer it to Excel for convenient data analysis. If it were to be split up now, with each command having its own template, I would have to find a way to integrate the data in the code. Fortunately, I now have AI assistance; otherwise, it would take me several months with my abilities. Thank you all for your enthusiastic help. However, I am still curious why my writing style, it does not recognize the '-'.
mjbear commentedon Jul 26, 2024
@tuobi555
No worries, we all start somewhere and learn new things every day.
Ah, I was thinking you might have been using a library such as Paramiko/Netmiko to connect to the device and pull output which you were then parsing with TextFSM.
It may be necessary to "anchor" the regexes to make them more rigid -- loose regexes can match in situations where you don't want them to.
Combining the structured output (from TextFSM) into a single object or output file wouldn't be too difficult.
Does the
display deviceoutput really differ from what you provided where theslotis sometimes not present in the leftmost "column"?reference: https://support.huawei.com/enterprise/en/doc/EDOC1100074755/91652f17/device-status-checking-commands#EN-US_CLIREF_0141119950
tuobi555 commentedon Jul 26, 2024
AS02.log
@mjbear The CE6800 series, CE128, and CE168 series, although all referred to as the CE series, have some differences in the distribution of display content. Moreover, the hardware configuration of my current environment is the same, and I am unable to provide sample data that shows the differences. Currently, there is also a CE68 series at the access layer available for your reference. I am very grateful to the enthusiastic friends for their help.
mjbear commentedon Jul 26, 2024
Hello @tuobi555
💡 Retrieving one large blob/string of commands from a device and parsing it with a single template is asking for difficulty. You should retrieve and parse command output individually (one command at a time) to simplify your problem.
❓ How are you retrieving your command output?
❓ Are you doing this via a programming language and/or automation software?
❗ There are some syntactically incorrect commands given the output saying
Error: Unrecognized command found at '^' position.❓ It doesn't make sense to parse both the output of
display vlananddisplay vlan brief. Wouldn't the normal vlan output contain everything as brief and more? (Same situation withdisplay stpanddisplay stp briefas well asdisplay ospf lsdbanddisplay ospf lsdb routerand so on.)❗ Wow, this is around 116 commands in one blob (cs01), which is when I stopped compiling my list below.
(Here's my [partial] guess in alphabetical order based on the "cs01" raw output you shared and Huawei command reference.)
💡 In case you end up having any interest in ntc-templates, here's some information:
https://pynet.twb-tech.com/blog/netmiko-and-textfsm.html
https://github.com/networktocode/ntc-templates/
https://github.com/networktocode/ntc-templates/tree/master/tests/huawei_vrp
https://ntc-templates.readthedocs.io/en/latest/user/lib_overview/
https://ntc-templates.readthedocs.io/en/latest/dev/dev_parser/#index-file
mjbear commentedon Jul 26, 2024
@tuobi555
Would you be able to get sanitized output for
display device elabeland put it in a code block in your response?(put X's in for your barcode, serial number, and any other sensitive information)
(The example in Huawei's
display device elabelcommand docs may have output removed.)mjbear commentedon Jul 30, 2024
@tuobi555
Are you willing to split up your process to one command at a time?
Do you have output for the command
display device elabel?tuobi555 commentedon Jul 31, 2024
@mjbear "Of course, that's fine. Initially, I just wanted to use this method to help me monitor the status of the equipment. As long as the requirements are met, it doesn't matter. Additionally, for the CE series devices, if you want to view the device's own serial number, the command should be 'display esn'. For other series, the commands might be 'display device manufacture-info' or 'display elabel slot slot-id', where 'slot-id' is the slot number of the corresponding device."
mjbear commentedon Jul 31, 2024
@tuobi555
You didn't say whether you're using Python, but regardless of the programming language it's simple to have a script loop through a list of commands and retrieve output from your VRP device.
I don't have access to any Huawei VRP devices. I'm trying to help you so that's why I need you to provide output.
Please provide output for
display device elabel(put X characters in for the serial number and anything else sensitive).If you like, I can look at your long template file but you'll need to share it.
tuobi555 commentedon Aug 3, 2024
@mjbear "The information I provided earlier was all the data I had collected. If there is no output for 'esn' in it, then there's nothing more that can be done. I also cannot casually take log files from my workplace. Thank you for your enthusiastic help. Of course, you can also share the command parsing templates that have already been made, so that more people can enjoy the convenience."
mjbear commentedon Aug 4, 2024
@tuobi555
Ok, I'm guessing there could be some misunderstanding or mistranslation occurring.
I'm not asking for sensitive or confidential data.
Output could come from a lab device that is not in production or mask the potentially "sensitive data" with other characters or words. But I won't push the subject as I have a feeling this isn't going much further.
The template I created covers three
display devicecommands since their output was similar. The new template details can be found at ntc-templates PR#1804.