CCT Calibration

This project calibrates one or more cameras from CCT target detections using a mix of detection, initialization, and bundle adjustment. The main workflows are:

  • run_combined.py for multi-camera rigs
  • run_cct_calibration.py for single-camera calibration

The repository is designed to work well both with a known 3D target reference and with a fully automatic SfM-based initialization path.

Requirements

  • Python 3.10 or newer
  • uv for dependency management and execution

Installation

Run this from the repository root:

uv sync

You can then invoke the scripts without activating a virtual environment:

uv run python run_cct_calibration.py --help
uv run python run_combined.py --help

Data layout

Multi-camera rig

For multi-camera calibration, place one subfolder per camera under a common root:

images/
  cam0/
    frame000.jpg
    frame001.jpg
  cam1/
    frame000.jpg
    frame001.jpg

The image file names should match across cameras so the pipeline can associate them by frame.

Single camera

For single-camera calibration, use a flat folder of images (the legacy photos_* layout is only supported with --detect-only).

Example flat-folder layout:

reflex/
  _CAL9476.JPG
  _CAL9477.JPG
  ...

Reference target file

If you have metric 3D target coordinates, pass them with --targets3d.

Supported input formats are:

  • simple whitespace- or tab-separated text: target_id x y z
  • Metashape-style exports with columns such as Label actual, X, Y, and Z

When --targets3d is provided, the pipeline can use those known coordinates to anchor the solution to a metric frame.

The reference file also defines the codebook: target IDs are then decoded by correlating the code ring with each valid code (all rotations), which recovers targets the generic decoder misses, including single-arc codes. Without --targets3d the generic decoder is used, unchanged (--valid-ids-file / --valid-id-max then only filter the decoded IDs).

Detection caches are stamped with the detector version; a cache from an older detector is reused with a warning, so pass --force-detections after a detector update.

Quick start

1. Multi-camera calibration

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output"

This runs the full pipeline:

  1. detect CCT targets in each camera
  2. initialize the rig with SfM
  3. run bundle adjustment
  4. write reports and calibration outputs

2. Multi-camera calibration with known target coordinates

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output_reference" \
  --targets3d "reference.txt"

This is the preferred mode when you have a reliable reference file. It constrains the solution to the known metric target geometry and improves the accuracy of the final poses and intrinsics.

3. Multi-camera calibration without SfM

If SfM is unstable or fails on a difficult dataset, you can skip it entirely:

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output_skip_sfm" \
  --targets3d "reference.txt" \
  --skip-sfm

This mode requires --targets3d. It bypasses pycolmap, uses the known 3D targets to initialize the camera poses, and then runs the remaining calibration steps.

4. Single-camera calibration

uv run python run_cct_calibration.py \
  --image-root "reflex" \
  --output-dir "reflex_output" \
  --targets3d "reference.txt"

This is the standard mono workflow for a flat image folder. A single camera is calibrated as the one-camera case of the combined pipeline: the same centre refinement, staged adjustment, covariance diagnostics, optional checkpoints and PDF report are used, and only rig-specific results (relative orientation, stereo diagnostics) are omitted. With --targets3d, the camera is initialized from the known targets (no SfM). Any option of run_combined.py (e.g. --checkpoints, --observation-sigma-px, --evaluate-detections, --no-pdf-report, --model fisheye, --dist k1 k2 k3 p1 p2) can be added. run_combined.py --image-root <folder of images> is equivalent.

Calibrating without --targets3d is possible but not recommended and prints a warning: initialization then uses natural-feature SfM, targets become free object points, and the scale of a single-camera solution is arbitrary (only the interior orientation is meaningful).

5. Detection-only mode

uv run python run_cct_calibration.py \
  --image-root "reflex" \
  --output-dir "reflex_output" \
  --targets3d "reference.txt" \
  --detect-only

This runs detection only and exports the detections without performing pose initialization or bundle adjustment.

Important flags

Common flags

  • --image-root: root folder with images. For multi-camera rigs this should contain camera subfolders such as cam0/ and cam1/. For mono calibration it can be a folder of image files directly.
  • --output-dir: destination folder for reports, summaries, caches, and plots.
  • --targets3d: path to a known 3D target reference file. Use this when you want a metric calibration.
  • --checkpoints [RATIO]: optionally withhold complete target IDs from target-based initialization and every calibration bundle for final independent accuracy checks. With no ratio it uses 0.2; --checkpoints 0 preserves the ordinary workflow. Checkpoint runs restore original detector coordinates from the cache so refined centers from an earlier target partition cannot leak into the experiment; only legacy or incomplete caches require a one-time redetection.
  • --checkpoint-seed: reproducible integer seed for checkpoint selection (default 42). The selected IDs and realised ratio are written to checkpoint_split.json.
  • --force-detections: ignore existing detection cache files and rerun target detection.
  • --workers: number of parallel image-processing workers for target detection, calibrated centre refinement and --evaluate-detections (default 0 = automatic, up to 8 limited by the CPU count; 1 = sequential). Results are identical; each worker holds one image in memory, so lower it for very large images on machines with little RAM.

Camera model flags

The projection and distortion functions follow COLMAP's camera models exactly (src/cct_calibration/camera_models.py); the intrinsics vector is fx fy cx cy followed by the selected coefficients, and exports use the matching COLMAP model.

  • --model {pinhole,fisheye} (default pinhole).
  • --dist NAME [NAME ...]: distortion coefficients to estimate, given as a preset or as coefficient names (space- or comma-separated). Coefficients that are not listed are fixed at zero.
--model --dist Estimated coefficients COLMAP / export model
pinhole opencv (default) k1 k2 p1 p2 OPENCV
pinhole e.g. k1 k2 k3 p1 p2 any subset of k1 k2 p1 p2 k3 k4 k5 k6 FULL_OPENCV (if beyond k1 k2 p1 p2)
pinhole full_opencv / none all eight / none FULL_OPENCV / OPENCV
fisheye opencv_fisheye (default) k1 k2 k3 k4 OPENCV_FISHEYE
fisheye e.g. k1 k2 k3 k4 p1 p2 any subset of k1 k2 p1 p2 k3 k4 sx1 sy1 THIN_PRISM_FISHEYE (if beyond k1..k4)
fisheye thin_prism_fisheye k1 k2 p1 p2 k3 k4 sx1 sy1 THIN_PRISM_FISHEYE
fisheye rad_tan_thin_prism_fisheye k0..k5 p0 p1 s0..s3 (or a subset) RAD_TAN_THIN_PRISM_FISHEYE
  • --no-cheirality-check (fisheye only): by default, as in COLMAP, points with camera depth z <= 0 are not projectable. For lenses with a field of view above 180° this flag accepts them; the fisheye angle is computed as atan2(r, z), which equals COLMAP's atan(r / z) in front of the camera. PnP-based initialisation and triangulation still use only directions below 90°.

Kalibr's camchain.yaml is written only for models Kalibr can represent (OPENCV → radtan, OPENCV_FISHEYE → equidistant). Cached refined centres record the camera model they were measured with and are re-measured when the model changes.

Multi-camera flags

  • --camera: choose specific camera folders. Repeat it to select multiple cameras explicitly, for example --camera cam0 --camera cam1.
  • --known-baseline: provide either the cam0–cam1 baseline magnitude (one value, metres) or its XYZ translation vector (three values); it initializes the SfM scale and applies the corresponding rig constraint.
  • --skip-sfm: bypass the SfM stage and bootstrap from known 3D targets instead. Requires --targets3d. Intrinsics are initialized from a bounded, geometry-diverse subset (up to 24 frames, selected from at most 96 candidates); fixed-intrinsic PnP then registers the remaining retained frames before the full bundle adjustment.
  • --force-sfm: ignore any existing SfM reconstruction cache and recompute it.
  • --min-detections: minimum number of detections required for an image to be kept.
  • --min-shared: minimum number of shared target observations required for initialization.
  • --max-reprojection-error: threshold in pixels for rejecting weak initial observations.
  • --max-iterations: maximum number of bundle-adjustment iterations.
  • --huber-delta: Huber loss parameter used in the solver.
  • --loss-tolerance: convergence threshold for stopping based on relative loss change.
  • --loss-patience: number of stable iterations before early termination.
  • --outlier-mad-scale: robust outlier threshold based on the median absolute deviation of object-space residuals.
  • --valid-ids-file: optional file listing valid target IDs.
  • --valid-id-max: use all target IDs from 0 to N as valid.
  • --max-id-hamming-distance: allow decoded target IDs to be snapped to the nearest valid ID only within this Hamming-distance limit.

Developer diagnostics

  • --evaluate-detections (off by default, requires --targets3d): projects every reference target with the final calibration, reports per-camera detection recall and detections far from the projection of their ID, and attributes each miss to the detector stage that rejected it (detection_evaluation.json). It re-runs detection on images with misses, so it is slow; it is a consistency tool for detector development, not independent ground truth.

Single-camera flags

  • --data-root: root directory containing the legacy photos_* folders (--detect-only only).
  • --camera: camera name for --detect-only; for calibration the camera is named after its image folder.
  • --detect-only: run detection only and skip initialization and bundle adjustment.
  • --show-3d: no longer available for calibration; inspect <output-dir>/colmap instead.

Caching behavior

The pipeline reuses previous intermediate results where possible.

  • Multi-camera detections are cached under each camera output folder as target_detections.txt.
  • Multi-camera SfM is cached under the output directory in the sfm/ folder.
  • Single-camera detections are cached the same way, under <output-dir>/<camera>/.

Use --force-detections or --force-sfm when you want to rebuild those intermediate results from scratch.

PDF calibration report

The multi-camera pipeline automatically generates calibration_report.pdf in the output directory. The report is aimed at photogrammetry experts and contains:

  • Summary — residual statistics (mean/RMS/median/percentiles for pixel and object-space residuals), per-camera overview, and solution redundancy (unknowns, degrees of freedom, redundancy ratio, outlier-filter accounting).
  • Residual analysis — signed u/v and radial/tangential statistics, standardized residuals, local redundancy, per-frame/per-target diagnostics, outlier selection, error histograms/CDFs, and bundle-adjustment convergence.
  • Parameter determinability — initial/final/status tables, marginal standard deviations and 95% intervals, the full correlation heatmap, a condition indicator, and the a-posteriori variance factor. Supplying --observation-sigma-px also enables a chi-square consistency test.
  • Projection uncertainty — intrinsic projection-uncertainty maps and joint calibration/triangulation uncertainty versus working distance.
  • Per-camera deep dive — binned signed-vector fields, separate u/v/radial/tangential heatmaps, error-vs-radius trends, distortion profiles, and density-aware FoV coverage.
  • Ground sampling distance — per-observation GSD (target depth / focal length, mm per pixel) with per-camera distributions and the GSD profile along the acquisition, image and point-to-ray residuals against GSD, ray errors expressed in GSD units, and checkpoint accuracy relative to the GSD of the checkpoint rays.
  • Network strength — pose, range, image-scale and field-angle distributions; camera-target connectivity; local reliability; and explicit weak-frame/weak-target tables. Surface-incidence angles are reported as unavailable unless target normals become part of the input model.
  • Rig quality (multi-camera only) — component-wise extrinsic uncertainty, shared support, Sampson error, rectified vertical disparity, stereo intersection angle, baseline/depth ratio, internal triangulation discrepancies, rig geometry and scene layout.

Pass --no-pdf-report to skip PDF generation. Use --observation-sigma-px VALUE to state the a-priori one-sigma precision of each image coordinate. The reporting code lives in src/cct_calibration/reporting/.

Pass --save-report-plots to also export every plot included in the PDF as a 600 dpi PNG in <output-dir>/plots/. Filenames are numbered in report order and include the plot title. The PDF itself keeps its usual resolution. This flag cannot be combined with --no-pdf-report.

Output files

Multi-camera outputs

Typical outputs include:

  • combined_summary.json
  • report.txt
  • calibration_report.pdf — rich PDF report (see below)
  • camchain.yaml
  • combined_convergence.png
  • sfm/
  • colmap/
  • per-camera detection folders and caches

Single-camera outputs

The same files as for a multi-camera rig (combined_summary.json, report.txt, calibration_report.pdf, camchain.yaml, colmap/, detection folders and caches), without the rig-specific content.

The reports contain reprojection error in pixels and, when available, object-space error in meters.

Suggested workflows

  • Use --targets3d whenever you have a reliable 3D reference file.
  • Use --skip-sfm when pycolmap is unstable or when the dataset is difficult.
  • Use --detect-only to inspect the detections before running full calibration.
  • Use --force-detections if you have changed the detector or the input images and want to rebuild the detections cache.

Example commands

Standard multi-camera run

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output"

Metric multi-camera run

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output_reference" \
  --targets3d "reference.txt"

Robust multi-camera run without SfM

uv run python run_combined.py \
  --image-root "images" \
  --output-dir "combined_output_skip_sfm" \
  --targets3d "reference.txt" \
  --skip-sfm

Mono run on a flat image folder

uv run python run_cct_calibration.py \
  --image-root "reflex" \
  --output-dir "reflex_output" \
  --targets3d "reference.txt"

About

Target-based calibration of multi-camera systems

Resources

Stars

3 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages