Code Contents Cause Operation Reset Procedure
Communication
error between
e-EPOS Automatic reset when
82 Communication Err!! * Note
controller and problem is corrected
instrument
panel
1 EPPR v/v short Short Circuit
Cut off output After correcting problem,
2 Press Up s/v short Short Circuit current (0 mA) turn start switch
3 Swing pri. s/v short Short Circuit
Automatic reset
11 EPPR v/v open Open Circuit
when problem is
corrected
12 Press Up s/v open Open Circuit
13 Swing pri. s/v open Open Circuit
Output voltage
21 Dial Voltage Err (H)
Over 4.6±0.2 V
Output voltage
22 Dial Voltage Err (L) Over
0.4±0.2 V
Cut off EPPR
Output voltage
23 TPS Voltage Err (H) v/v current (0
Over 4.6±0.2 V
mA)
Cut off EPPR
Output voltage v/
24 TPS Voltage Err (L)
Over 0.4±0.2 V v current (0
mA)
Output voltage
25 Fpump Sensor Err (H)
Over 4.6±0.2 V
Output voltage
26 Fpump Sensor Err (L)
Over 0.4±0.2 V
Output voltage
26 Fpump Sensor Err (L)
Over 0.4±0.2 V
Output voltage
27 Rpump Sensor Err (H)
Over 4.6±0.2 V
Output voltage
28 Rpump Sensor Err (L)
Over 0.4±0.2 V
Under
1067±20Hz (On
condition that
29 Speed Sensor Err
alternator
output exceeds
over 12±1V)
Sensor’s
resistance
between two
31 Fuel shot to GND
terminals is
under
150±100W
Sensor’s
resistance
between two
32 Fuel Sensor open
terminals is
under 6.5±0.5
kW
Output voltage
of
alternator
33 Alternator too high exceeds 33 V
for more than 3
seconds
When the
output voltage
is maintained
under 18±1 for
more than 3
34 Alternator too low
seconds (On
condition that
speed sensor
output exceeds
over 1,067Hz)