PAGE 1
INJECTOR SPECIFICATION
EDITION: 4 NOZZLE HOLDER
APPLICATIONS: SEE PAGE 2 ASSEMBLY NO. 34107
DATED: 02-12-99 SUPERSEDES:
CUSTOMER: AABENRAA CUSTOMER PART NO. SEE PAGE 2
TEST STAND: ISO 8984 NOTE: Reference Conventional Injector
1. CALIBRATION FLUID...SAE J967 / ISO 4113 Service Manual 99118 for additional
(Ref. S.B. 201). AT ROOM TEMPERATURE (70°-80° F) service information.
2. CALIBRATING HIGH PRESSURE PIPES... 0.063 X 12"
(1.6 X 305 mm)
ITEM PART
NO. NO. QTY. DESCRIPTION
1 34107 1 BODY ASSY, * (1 PREFERRED 2 MAX.)
nozzle holder PART THICKNESS
NO. mm (inches)
781229 1.000 (.0397)
2 SEE * SHIM, pressure 781230 1.050 (.0413)
TABLE adjusting 781231 1.100 (.0433)
781232 1.150 (.0453)
781233 1.200 (.0472)
781234 1.250 (.0492)
3 34164 1 SPRING, pressure 781235 1.300 (.0512)
adjusting 781236 1.350 (.0531)
781237 1.400 (.0551)
781238 1.450 (.0571)
781239 1.500 (.0591)
4 33578 * SEAT, spring 781240 1.550 (.0610)
781241 1.600 (.0630)
781242 1.650 (.0650)
781243 1.700 (.0669)
781244 1.800 (.0709)
5 29418 1 PLATE ASSEMBLY, 781246 1.850 (.0728)
adapter 781247 1.900 (.0748)
6 PAGE 2 1 NOZZLE ASSEMBLY, hole type
(not included in nozzle holder assembly)
7 34109 1 NUT, nozzle retaining
(torque to 50-60 N⋅m / 37-44 lbf⋅ft)
8 --- 1 WASHER , sealing (purchased separately)
FOR ENGINEERING USE ONLY
DATE ECN NO. EDITION
02-17-98 25153 1
11-18-98 25153 2
11-20-98 25153 3
02-12-99 26134 4
PAGE 2
APPLICATION AND SERVICE INFORMATION
FOR HOLDER ASSEMBLY 34107
INJECTOR NOZZLE
STANADYNE CUSTOMER INSCRIPTION STANADYNE CUSTOMER INSCRIPTION APPLICATION
PART NO. PART NO. CODE PART NO. PART NO. CODE
34106 610 B 9120 PER 70157 34110 - PER 70157 DV 29 / 48
SDLLA 150P 34
34494 610 B 9250 PER 70157 34495 610 B 9152 PER 70157 DV 29 / 48
SDLLA 150P 50
OPENING PRESSURE
NEW AND SERVICE
INJECTOR MAX VALVE LIFT NO. OF HOLES
NO. MPa (PSI) mm (inches) @ DIA. mm (inches)
34106 18.0 - 18.8 (2610 - 2726) 0.275 (.0108) 4 @ 0.245 (.00964)
34494 23.0 - 23.8 (3335 - 3451) 0.325 (.0127) 4 @ 0.272 (.0107)
For bar, multiply MPa by 10
Maximum valve lift for service: + 0.05mm beyond value shown in table.