MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted
currents, input current 0...0.2 to 0...11 A, unconfigured
Your advantages
True r.m.s. value measurement
Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software
3-way isolation
Key Commercial Data
Packing unit 1 pc
GTIN
GTIN 4017918169275
Technical data
Note
EMC: class A product, see manufacturer's declaration in the download
Utilization restriction
area
Dimensions
Width 22.5 mm
Height 99 mm
Depth 114.5 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Maximum altitude < 2000 m
Degree of protection IP20
Noise immunity EN 61000-6-2
09/18/2019 Page 1 / 6
https://www.phoenixcontact.com/pi/products/2814715
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715
Technical data
Input data
Input Current measuring input
Number of inputs 3
Configurable/programmable Yes, unconfigured
Input current range 0 A ... 11 A (AC/DC)
Operate threshold 2 % (of measuring range nominal value 1/5/10 A)
Setting range for min. input current 0 A ... 200 mA
Setting range for max. input current 0 A ... 11 A
Impulse form AC, DC or distorted currents
Overload capacity 2 x IN (continuous)
Surge strength 20 x IN (1 s)
Frequency measuring range 15 Hz ... 400 Hz
Connection method Screw connection
Output data
Output name Voltage output / current output
Configurable/programmable Yes, unconfigured
Voltage output signal 0 V ... 10 V
2 V ... 10 V
-10 V ... 10 V
0 V ... 5 V
1 V ... 5 V
-5 V ... 5 V
10 V ... 0 V
10 V ... 2 V
10 V ... -10 V
5 V ... 0 V
5 V ... 1 V
5 V ... -5 V
Current output signal 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Load/output load voltage output > 10 kΩ
Load/output load current output < 500 Ω
Switching output
Output name No switching output
Power supply
Supply voltage range 20 V DC ... 30 V DC
Max. current consumption < 40 mA (without load)
Connection data
09/18/2019 Page 2 / 6
https://www.phoenixcontact.com/pi/products/2814715
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715
Technical data
Connection data
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
General
Maximum transmission error < 0.5 % (of nominal range value under nominal conditions)
Temperature coefficient, typical < 0.025 %/K
Step response (10-90%) 330 ms (with AC)
40 ms (with DC)
Status display Green LED
Overvoltage category III
Degree of pollution 2
Rated insulation voltage 300 V AC (to earth)
Test voltage input/output 4 kV (50 Hz, 1 min.)
Test voltage input/power supply 4 kV (50 Hz, 1 min.)
Test voltage output/power supply 500 V (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Color green
Housing material Polyamide PA non-reinforced
Mounting position any
Conformance CE-compliant
UL, USA/Canada Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Connection in acc. with standard CUL
Low Voltage Directive Conformance with Low Voltage Directive
Conformance CE-compliant
UL, USA/Canada Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
09/18/2019 Page 3 / 6
https://www.phoenixcontact.com/pi/products/2814715
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
09/18/2019 Page 4 / 6
https://www.phoenixcontact.com/pi/products/2814715
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715
Dimensional drawing
Circuit diagram
Approvals
Approvals
09/18/2019 Page 5 / 6
https://www.phoenixcontact.com/pi/products/2814715
Current transducers - MCR-S-1/5-UI-DCI-NC - 2814715
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / cULus Listed
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
EAC
EAC-Zulassung
cULus Recognized
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com