https://www.phoenixcontact.
com/pi/products/2814663
Current transducers - MCR-S-10-50-UI-SW-DCI - 2814663
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and
distorted currents, with relay and transistor output, input current 0...10 to 0...50 A, configured
The figure shows version MCR-
S-10-50-UI-DCI
Why buy this product
3-way isolation
Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software
True r.m.s. value measurement
Key Commercial Data
Packing unit 1 STK
Weight per Piece (excluding packing) 189.400 g
Weight per piece (including packing) 189.400 g
Custom tariff number 85437090
Country of origin Germany
Note Made to Order (non-returnable)
Technical data
Note
EMC: class A product, see manufacturer's declaration in the download
Utilization restriction
area
Dimensions
Width 22.5 mm
Height 99 mm
Depth 114.5 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Maximum altitude < 2000 m
01/22/2018 Page 1 / 5
https://www.phoenixcontact.com/pi/products/2814663
Current transducers - MCR-S-10-50-UI-SW-DCI - 2814663
Technical data
Input data
Input Current measuring input
Configurable/programmable Yes, preconfigured
Operate threshold 0.8 % (of measuring range nominal value 50 A)
Setting range for min. input current 0 A ... 9.5 A
Setting range for max. input current 0 A ... 55 A
Impulse form AC, DC or distorted currents
Overload capacity Depending on through connected conductor
Surge strength Depending on through connected conductor
Frequency measuring range 15 Hz ... 400 Hz
Connection method Through connection, diameter 10.5 mm
Output data
Output name Voltage output / current output
Configurable/programmable Yes, preconfigured
Voltage output signal 0 V ... 10 V
2 V ... 10 V
-10 V ... 10 V
0 V ... 5 V
1 V ... 5 V
-5 V ... 5 V
10 V ... 0 V
10 V ... 2 V
10 V ... -10 V
5 V ... 0 V
5 V ... 1 V
5 V ... -5 V
Current output signal 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Load/output load voltage output > 10 kΩ
Load/output load current output < 500 Ω
Switching output
Output name Relay output
Contact type 1 PDT
Contact material AgSnO, hard gold-plated
Maximum switching voltage 30 V AC
36 V DC
250 V AC
Limiting continuous current 50 mA (for gold layer, 30 V AC/ 36 V DC)
2 A (in case of a destroyed gold layer, 250 V AC)
01/22/2018 Page 2 / 5
https://www.phoenixcontact.com/pi/products/2814663
Current transducers - MCR-S-10-50-UI-SW-DCI - 2814663
Technical data
Switching output
Output name Transistor output, pnp
Output voltage range 19 V ... 29 V (supply voltage - 1 V)
Continuous load current 80 mA (Not short-circuit proof)
Setting range of the threshold value 1 % ... 110 %
Setting range of the response delay 0.1 s ... 20 s
Status display Yellow LED
Power supply
Supply voltage range 20 V DC ... 30 V DC
Max. current consumption < 50 mA (without load)
Connection data
Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Stripping length 8 mm
Screw thread M3
General
Maximum transmission error < 0.5 % (of nominal range value under nominal conditions)
Temperature coefficient, typical < 0.025 %/K
Step response (10-90%) 330 ms (with AC)
40 ms (with DC)
Status display Green LED
Overvoltage category III
Degree of pollution 2
Rated insulation voltage 300 V AC (to earth)
Test voltage input/output 4 kV (50 Hz, 1 min.)
Test voltage input/power supply 4 kV (50 Hz, 1 min.)
Test voltage output/power supply 500 V (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Color green
Housing material Polyamide PA non-reinforced
Mounting position any
Conformance CE-compliant
UL, USA/Canada Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
01/22/2018 Page 3 / 5
https://www.phoenixcontact.com/pi/products/2814663
Current transducers - MCR-S-10-50-UI-SW-DCI - 2814663
Technical data
General
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Connection in acc. with standard CUL
Low Voltage Directive Conformance with Low Voltage Directive
Conformance CE-compliant
UL, USA/Canada Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Classifications
eCl@ss
eCl@ss 5.0 27210190
eCl@ss 5.1 27210190
eCl@ss 6.0 27210190
eCl@ss 7.0 27210123
eCl@ss 8.0 27210123
eCl@ss 9.0 27210123
ETIM
ETIM 3.0 EC002475
ETIM 4.0 EC002475
ETIM 5.0 EC002475
ETIM 6.0 EC002475
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 39121032
Approvals
Approvals
01/22/2018 Page 4 / 5
https://www.phoenixcontact.com/pi/products/2814663
Current transducers - MCR-S-10-50-UI-SW-DCI - 2814663
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / cULus Listed
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
EAC
EAC-Zulassung
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
01/22/2018 Page 5 / 5