Time Sync.
Tester/Analyzer - TimeCatcher 1588
                                                                                    TimeCatcher 1588
                                                                                    Time Synchronization Tester / Analyzer
     The TimeCatcher 1588 is a Sync Tester / Analyzer that allow the user to test and analyze synchronization quality and compliance
     in various types of networks. The TimeCatcher 1588 is developed for both traditional SDH/SONET core networks and IP-based
     backhaul networks, that can measure synchronization conformance simultaneously at a packet sync level (based on SyncE and
     IEEE 1588v2 technologies) and at a traditional physical sync level (1PPS, E1 interface) behind a packet synchronized devices.
     Multiple packet sync measurements can be performed, whether it’s related to IEEE 1588v2 slave / boundary clock performance
     qualification or SyncE wander can be also measured at any node in the network.
     Basic Function
     ▪▪Embedded time and frequency GPS / Rubidium reference                      do not have GPS antenna environment
        Visible Fault Locator fast locates defective connectors, faults in     ▪▪Provide G.703 2.048MHz, 2.048Mb/s accuracy external clock
        macrobends, patch cords and patch cord panels                            input interface
     ▪▪Built-in Rubidium oscillator, High sensitivity GPS receiver,BD          ▪▪Supports long period continue test,Statistic analysis time
        receiver for timing measurement vs UTC                                   synchronization and clock synchronization long-term
     ▪▪High sensitivity measurement 1588v2 time server, PTN/                     drift,calculateMTIE, TDEV
        OTN Data transmission devices and traditional physical                 ▪▪Instantscreen capturefunction, you can savetest result via
        sync level (PTP,1PPS, 1PPS+TOD)                                          graph modeinstant
     ▪▪ Precision measurement IEEE1588v2 clock synchronization or SyncE        ▪▪Supports testresult storedand datareplayfunction
        clock synchronization accuracy performance including                   ▪▪Built-in Li-Ion rechargeable battery, supports 8 hours
        2.048MHz, 2.048Mb/s, Ethernet                                            continuous operation
     ▪▪TOD instant message display, TOD deviation real-time                    ▪▪USB data upload/download ports, Results of measurements
        display                                                                  on a PCsorting, archiving, analysis
     ▪▪PTPmessage sinstantly capture, analysis, storage, PTP                   ▪▪Extensive systeminformation query functions, such as
        synchronization processinstantly displays                                satellitestate, Rubidiumstate, storage space, temperature,
     ▪▪use as auxiliary timeserver to provide 1PPS+TOD or PTP                    and otherinformation
        signal for system time                                                 ▪▪Supports tassociationtest function, PTP + TOD simultaneously
     ▪▪Select GPS Rubidium atomic clock for at least 3 hour                      test
        continue test, suitable for indoor or the place where user             ▪▪Supports multi-input physical sync measurements
     Main Features
     ▪▪7 inch TFT color screen operation,language support Chinese/ English with GUI interface
     ▪▪Fully comply with IEEE, ITU-T standard
     ▪▪Provide differenttypes of test modules for users,to meet the different requirements of the test environment
     ▪▪Supports Instant results, trends, test patterns, message statistics, packet analysis, compensationview
     ▪▪Supports PTP / TOD simulation tests
     ▪▪Supports manual, automatic and timed tests
     ▪▪Supports real-time screenshots, and the test result can be saved as an image at anytime
     ▪▪Supports in-depth analysis, template matching
     ▪▪Supports on-line firmware upgrade
     Specifications
     Built-in GPS       L1 Band: CA code 50 channels, L1 frequency 1575MHz      Input port                    TOD: RS422, RS232          1PPS: TTL
     receiver           1 PPS accuracy: 15ns                                                                  G.703: 2.048MHz, 10MHz
     Built-in BD        Compass B1: 24 channels, B1 frequency 1561MHz                                         PTP: 10/100/1000Base-T, 100Base-FX, 1000Base-FX
     receiver           1PPS accuracy: 30ns                                                                   Supports Unicast and Multi-cast
     TOD mode                                                                   Ext. Clock Input
                        China Mobile, NMEA, ASCII                                                G.703: 2.048MHz, 2.048Mb/s
                                                                                port
     Rubidium atomic                                                            Management port Console, USB, 10/100Base-TX Ethernet
                        1x 10-12(Typical values)
     clock
     Depthlock time                                                             Battery          Li-Ion Rechargeable battery, supports 8 hours
                        45 minutes
                                                                                                 continuous operation
     Frequency test     1x10 -9                                                 Battery Recharge 3 hours
     accuracy
                                                                                time
     Time Test Input    1PPS + TOD: RS422, RS232      TOD: RS422, RS232
     port                                                                       Power Input      16V/8A DC adatpter
                        1PPS: TTL
                        PTP: 10/100/1000Base-T, 100Base-FX, 1000Base-FX         LCD screen       7 inch TFT color screen, 800x480
                        Supports Unicast and Multi-cast                         Dimension        292mm x 200mm x 90mm (W x H x D)
     Clock Test Input   G.703: 2.048MHz, 2.048Mb/s                              Temperature
     port                                                                                        Operating 0 ~ 50°C, Storage -20°C ~ 60°C
                        Sync-E: 10/100/1000Base-T, 100Base-FX, 1000Base-FX
                                                                                Humidity         0% ~ 95% non-condensing
                                                                                Weight           2.3kg (with Battery)
                                                                       Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details.
 13-2                       www.ctcu.com
                            sales@ctcu.com                             TimeCatcher 1588
                                                                                                Time Sync. Tester/Analyzer - TimeCatcher 1588
  Typical Application
   Based on IEEE 1588 Time Synchronization base station site deployment, security, cost, future maintenance, GPS has Obvious
   advantages.
   IEEE 1588 implementations need to assume that two-way pass time delay is equal, but Fiber cutover/Fiber splicing/jump fiber/
   network transformation and expansion may affect time delay and cause time synchronization accuracy goes down. As a result,
   when user doing the installation, test and maintenance, making time synchronization accuracy is very important.
     Port1 Synchronization device and transmission device use GPS and Compass asreference time source for instant
     measuringtime synchronizationto synchronizethe device output accuracy and long-term stability.
                                                                                                                                                                                    13
    ▪▪Synchronization device time synchronization deviation test
                                                                                                                                                                                     Time Sync. Tester/
    ▪▪Synchronization device long-term stability and time keeping ability test
    ▪▪Synchronous deviceGPS, Compass test switch performance changes
                                                                                                                                                                                         Analyzer
     Port2 Transmission device use tester built-in high performance Rubidium atomic clock for reference time to measure
     time synchronization accuracy for PTP interface and 1PPS + TOD output interface.
    ▪▪By-point basis Link asymmetric compensation                                                         ▪▪IEEE1588 PTP Synchronization message Mechanism analysis
    ▪▪Transmission devicetime outputdeviationtest                                                         ▪▪BMC best verification clock mechanism vertification
    ▪▪TOD Packet decoding analysis
     Port3 Transmission device and base station device use GPS and Compass to lock the reference time for the tester built-in
     Rubidium atomic clock. Then connect to base station device time and clock output interface to verify the transmission
     accuracy when time info pass through the network.
    ▪▪The verification of time delay compensation function when P to P link asymmetric
    ▪▪The verification of time accuracy when time path switching.
    ▪▪The verification of time source info when time switching.
  Application
 GPS/Compass                                                                                                                                GPS/Compass
 Statellite Positioning System                                                                                                              Statellite Positioning System
                                                                                                                                Base station
                                    1
                                                                                                2                                                            BBU            RRU
                                                    Aggregation                                                        ACCESS                       3
                                                                                                                                                         Base station
                                                                                                2
                                                                                                                                        3
                      RNC
                                                                                                                                                  Base station
  Ordering Information
   Model Name                           Description
   TimeCatcher 1588                     Time Synchronization Tester / Analyzer
Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details.
                                                                               TimeCatcher 1588
                                                                                                                                    www.ctcu.com
                                                                                                                                    sales@ctcu.com                                13-3