0% found this document useful (0 votes)
107 views18 pages

Crossover Matrix EJA-A To EJA-E

This document provides a crossover matrix to convert EJA-A series transmitters to the new EJA-E series transmitters. It lists the applicable EJA-A models and provides a simple matching system to identify the corresponding EJA-E code and specifications based on the EJA-A code description. The matrix includes categories such as transmitter type, output signal, measurement span, wetted parts material, process connections, and more.

Uploaded by

Gie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views18 pages

Crossover Matrix EJA-A To EJA-E

This document provides a crossover matrix to convert EJA-A series transmitters to the new EJA-E series transmitters. It lists the applicable EJA-A models and provides a simple matching system to identify the corresponding EJA-E code and specifications based on the EJA-A code description. The matrix includes categories such as transmitter type, output signal, measurement span, wetted parts material, process connections, and more.

Uploaded by

Gie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

Crossover

Matrix EJA-A Series to EJA-E Series

ඵ Introduction
This Crossover Matrix is designed to quickly and
accurately convert an EJA-A series transmitter to
the new EJA-E series transmitter.

ඵ Applicable Models
EJA110A, EJA120A, EJA130A, EJA210A, EJA220A,
EJA310A, EJA430A, EJA440A, EJA510A, and
EJA530A

ඵ Instructions
This Matrix is a simple cross match system.

Corresponding EJA-E code and position


EJA-A Series code

EJA-E Series Code Description


EJA-A Series Code Description

Availability of EJA-A Series Option


in EJA-E Series
ඵ Symbol Key

Yokogawa Corporation of America PCO-501


2 Dart Road; Newnan, Georgia U.S.A. 30265 Original Issue April 2013
Tel: 1-800-888-6400 1st Edition April 2013
2

ඵ Contents

>Differential Pressure Transmitter


EJA110A to EJA110E Page 3
EJA120A to EJA120E Page 3
EJA130A to EJA130A Page 3

>Level Transmitter
EJA210A to EJA210E Page 6
EJA220A to EJA210E Page 9

>Absolute Pressure Transmitter


EJA310A to EJA310E Page 12

>Gauge Pressure Transmitter


EJA430A to EJA430A Page 12
EJA440A to EJA440E Page 12

>In-Line Transmitter
EJA510A to EJA510E Page 15
EJA530A to EJA530E Page 15

PCO-501
Original Issue April 2013
1st Edition April 2013
3

‫ ڰ‬EJA110A, EJA120A, and EJA130A


Start
Here

EJA110E

EJA120E

EJA130E
Transmitter Type (Pressure Type) - X X X X X - X X X X X / ….
EJA110A Differential Pressure S EJA110E - - / Differential Pressure
EJA120A Differential Pressure S EJA120E - - / Differential Pressure
EJA130A Differential Pressure S EJA130E - - / Differential Pressure
Output Signal
-D 4 to 20 mA with BRAIN S S S - D - / 4 to 20 mA with BRAIN
-E 4 to 20 mA with HART 5 S S S - J - / 4 to 20 mA with HART 5/7
-F FOUNDATION Fieldbus S S S - F - / FOUNDATION Fieldbus
-G PROFIBUS PA X X X - - / Future Option
Measurement Span (Capsule)
E 0.4 to 4 inHЇK X S X - E - / 0.4 to 4 inHЇK
L 2 to 40 inHЇK - F - / 2 to 20 inHЇK;Wetted Part Material code S)
S X X
- L - / ϮƚŽϰϬŝŶ,ЇK;ůůŽƚŚĞƌtĞƚƚĞĚWĂƌƚDĂƚĞƌŝĂůĐŽĚĞƐͿ
M 4 to 400 inHЇK S X S - M - / 4 to 400 inHЇK
H 20 to 2000 inHЇK S X S - H - / 20 to 2000 inHЇK
V 20 to 2000 psi S X X - V - / 20 to 2000 psi
Wetted Parts Material
S Hastelloy / 316 SST / 316 SST S S S - S - / Hastelloy / 316 SST / 316 SST
H Hastelloy / Hastelloy / 316 SST S X X - H - / Hastelloy / Hastelloy / 316 SST
M Monel / Monel / 316 SST S X X - M - / Monel / Monel / 316 SST
T Tantalum / Tantalum / 316 SST S X X - T - / Tantalum / Tantalum / 316 SST
A Hastelloy / Hastelloy / Hastelloy S X X - A - / Hastelloy / Hastelloy / Hastelloy
D Tantalum / Hastelloy / Hastelloy S X X - D - / Tantalum / Hastelloy / Hastelloy
B Monel / Monel /Monel S X X - B - / Monel / Monel /Monel
Process Connections
0 EŽĐŽŶŶĞĐƚŽƌƐ;ZĐϭͬϰͿ S S S - 0 - / EŽĐŽŶŶĞĐƚŽƌƐ;ZĐϭͬϰͿ
1 Rc 1/4 S S S - 1 - / Rc 1/4
2 Rc 1/2 S S S - 2 - / Rc 1/2
3 1/4 NPT S S S - 3 - / 1/4 NPT
4 1/2 NPT S S S - 4 - / 1/2 NPT
5 EŽĐŽŶŶĞĐƚŽƌƐ;ZĐϭͬϮͿ S S S - 5 - / EŽĐŽŶŶĞĐƚŽƌƐ;ZĐϭͬϮͿ
Bolts
A SCM435 S S S - J - / B7 Carbon Steel
B SUS630 S S S - G - / 316L SST
C SUH660 S S S - C - / 660 SST
Installation
-2 Vertical RSHP PCU U U U - - 7 / Vertical LSHP PCD
-3 Vertical RSHP PCD U U U - - 7 / Vertical LSHP PCD
-6 Vertical LSHP PCU U U U - - 7 / Vertical LSHP PCD
-7 Vertical LSHP PCD S S S - - 7 / Vertical LSHP PCD
-8 Horizontal RSHP S S S - - 8 / Horizontal RSHP
-9 Horizontal LSHP S S S - - 9 / Horizontal LSHP
Electrical Connection
0 G 1/2 S S S - - 0 / G 1/2
2 1/2 NPT S S S - - 2 / 1/2 NPT
3 Pg 13.5 X X X - - / Not Avialable
4 M20 S S S - - 4 / M20
5 G 1/2 with Plug S S S - - 5 / G 1/2 with Plug
7 1/2 NPT with Plug S S S - - 7 / 1/2 NPT with Plug
8 Pg 13.5 with Plug X X X - - / Not Avialable
9 M20 with Plug S S S - - 9 / M20 with Plug
A G 1/2 with 316 SST Plug S S S - - A / G 1/2 with 316 SST Plug
C 1/2 NPT with 316 SST Plug S S S - - C / 1/2 NPT with 316 SST Plug
D M20 with 316 SST Plug S S S - - D / M20 with 316 SST Plug
Display
D Display S S S - - D / Display
E Display with switch S S S - - E / Display with switch
N No Display S S S - - N / No Display
Bracket
A &ůĂƚ;^Ϳ U U U - - B / &ůĂƚ;ϯϬϰ^^dͿ
B &ůĂƚ;ϯϬϰ^^dͿ S S S - - B / &ůĂƚ;ϯϬϰ^^dͿ
J &ůĂƚ;ϯϭϲ^^dͿ S S S - - J / &ůĂƚ;ϯϭϲ^^dͿ
C >ͲƚLJƉĞ;^Ϳ U U U - - D / >ͲdLJƉĞ;ϯϬϰ^^dͿ
D >ͲdLJƉĞ;ϯϬϰ^^dͿ S S S - - D / >ͲdLJƉĞ;ϯϬϰ^^dͿ
K >ͲdLJƉĞ;ϯϭϲ^^dͿ S S S - - K / >ͲdLJƉĞ;ϯϭϲ^^dͿ
N None S S S - - N / None

EXAMPLE: EJA110E - J M S 5 G - 9 2 E N/

Continued on next page Determine Amplifier Housing Material code per EJA-E GS to complete model code.

PCO-501
Original Issue April 2013
1st Edition April 2013
4

‫ ڰ‬EJA110A, EJA120A, and EJA130A


Continue
Here

EJA110E

EJA120E

EJA130E
Agency Approvals (Optional) EJAxxxE - X X X X X - X X X X X / ….
/FF1 FM Explosionproof - -
S S S / FF1 FM Explosionproof
/FF15 FM Explosionproof (Fieldbus) - -
/FS1 FM Intrinsically Safe S S S - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) S S S - - / FS15 FM Intrinsically Safe (Fieldbus)
/FU1 FM Combo S S S - - / FU1 FM Combo
/KF21 ATEX Flameproof S S S - - / KF22 ATEX Flameproof
/KS2 ATEX Intrinsically Safe S S S - - / KS21 ATEX Intrinsically Safe
/KS25 ATEX Intrinsically Safe (Fieldbus) S S S - - / KS26 ATEX Intrinsically Safe (Fieldbus)
/KU22 ATEX Combo S S S - - / KU22 ATEX Combo
/CF1 CSA Explosionproof - -
S S S / CF1 CSA Explosionproof
/CF15 CSA Explosionproof (Fieldbus) - -
/CS1 CSA Intrinsically Safe S S S - - / CS1 CSA Intrinsically Safe
/CU1 CSA Combo S S S - - / CU1 CSA Combo
/SU2 IECEx Combo U U U - - / SF2 IECEx Flameproof

EXAMPLE: EJA110E - J M S 5 G - 9 1 2 E N / FF1

Continued on next page

PCO-501
Original Issue April 2013
1st Edition April 2013
5

‫ ڰ‬EJA110A, EJA120A, and EJA130A


Continue
Here

EJA110E

EJA120E

EJA130E
High Accuracy (Option) EJAxxxE - X X X X X - X X X X X / ….
/HAC High Accuracy S S X - - / HAC High Accuracy
Painting (Option)
/P1 Amp Cover Black S S S - - / P1 Amp Cover Black
/P2 Amp Cover Jade Green S S S - - / P2 Amp Cover Jade Green
/P7 Amp Cover Metallic Silver S S S - - / P7 Amp Cover Metallic Silver
/PR Amp and terminal Cover Red S S S - - / PR Amp and terminal Cover Red
/X1 Epoxy Paint U U U - - / X2 Anti-corrosion Paint
316 SST Exterior Parts (Option)
/HC 316 SST Exterior Parts S S S - - / HC 316 SST Exterior Parts
Fluoro-rubber O-ring (Option)
/HE Fluoro-rubber O-ring S S S - - / HE Fluoro-rubber O-ring
Lightning Protector (Option)
/A Lightning Protector S S S - - / A Lightning Protector
Oil-prohibited use (Option)
/K1 Degrease S S S - - / K1 Degrease
/K2 Degrease with fluorinated oil fill S X S - - / K2 Degrease with fluorinated oil fill
/K5 Degrease with dehydration treatment S S S - - / K5 Degrease with dehydration treatment
/K6 Degrease, fluorinated oil fill, & deh. S X S - - / K6 Degrease, fluorinated oil fill, & deh.
Calibration Units (Option)
/D1 psi S S S - - / D1 PSI
/D3 Bar S S S - - / D3 Bar
/D4 Kgf/cm² S S S - - / D4 Kgf/cm²
Sealing Treatment (Option)
/Y Sealing Treatment on 630 SST Bolts X X X - - / Not available
Long Vent (Option)
/U Long Vent S S S - - / U1 Long Vent
Fast Response (Option)
/F1 Fast Response Z Z Z - - / Standard - no option code required
Analog Signal Options (Option)
/C1 Standard output, failure down-scale S S S - - / C1 Standard output, failure down-scale
/C2 Namur NE43 output, failure down-scale S S S - - / C2 Namur NE43 output, failure down-scale
/C3 Namur NE43 output, failure up-scale S S S - - / C3 Namur NE43 output, failure up-scale
Stainless Steel Housing (Option)
/E1 Stainless Steel Housing S S S - - 2 / Stainless Steel Housing
Gold Plated Diaphragm (Option)
/A1 Gold Plated Diaphragm S X S - - / A1 Gold Plated Diaphragm
Custom Software (Option)
/R1 Custom Software X X X - - / Not available
Body Options (Option)
/N1 No drain or vent plugs S S S - - / N1 No drain or vent plugs
/N2 N1 with kidney flange S S S - - / N2 N1 with kidney flange
/N3 N2 with material certs S S S - - / N3 N2 with material certs
Wired on Tag (Option)
/N4 Wired on Tag S S S - - / N4 Wired on Tag
Low volume cover flange (Option)
/N5 For remote seal attachment S X X - W - / For remote seal attachment
Fieldbus Options (Option)
/LC1 PID Control Z Z Z - - / Standard - no option code required
/EE Software Download S S S - - / EE Software Download
Data Configuration (Option)
/CA Hart Data Configuration S S S - - / CA Hart Data Configuration
PED (Option)
/PE3 PED X X S - - / PE3 PED
Material Certificate (Option)
/M01 Material Certificate S S S - - / M01 Material Certification
/M11 Material Certificate S S S - - / M11 Material Certification
Pressure Test (Option)
/T01 Pressure Test X X X - - / T12 Pressure Test
/T04 Pressure Test X S X - - / T04 Pressure Test
/T09 Pressure Test X X S - - / T09 Pressure Test
/T12 Pressure Test S X X - - / T12 Pressure Test

EXAMPLE: EJA110E - J M S 5 G - 9 2 2 E N / FF1 / HG / M01 / T09 / D1

Model code complete!

PCO-501
Original Issue April 2013
1st Edition April 2013
6

‫ ڰ‬EJA210A
Start
Here

EJA210E
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
EJA210A Flange Mounted DP Transmitter S EJA210E - S - - W 0 - / Flange Mounted DP Transmitter
Output Signal
-D 4 to 20 mA with BRAIN S - D - - - / 4 to 20 mA with BRAIN
-E 4 to 20 mA with HART 5 S - J - - - / 4 to 20 mA with HART 5/7
-F FOUNDATION Fieldbus S - F - - - / FOUNDATION Fieldbus
-G PROFIBUS PA X - - - - / Future Option
Measurement Span (Capsule)
M 4 to 400 inHЇK S - M - - - / 4 to 400 inHЇK
H 20 to 2,000 onHЇK S - H - - - / 20 to 2,000 onHЇK
Wetted Parts Material
S 316L SST / 316 SST S - - - SW - / 316L SST / 316 SST
H Hastelloy / Hastelloy S - - - HW - / Hastelloy / Hastelloy
T Tantalum / Tantalum S - - - TW - / Tantalum / Tantalum
W Hastelloy / 316 SST S - - - WW - / Hastelloy / 316 SST
Process Flange Rating
J1 JIS 10K S - - - J1 - / JIS 10K
J2 JIS 20K S - - - J2 - / JIS 20K
A1 ANSI Class 150 S - - - A1 - / ANSI Class 150
A2 ANSI Class 300 S - - - A2 - / ANSI Class 300
D2 DIN PN10/16 S - - - P1 - / DIN PN10/16
D4 DIN PN25/40 S - - - P2 - / DIN PN25/40
P1 JPI Class 150 S - - - D2 - / JPI Class 150
P2 JPI Class 300 S - - - D4 - / JPI Class 300
Process Flange Size / Material
A 2-inch / S25C S - - - 2 A - / 2-inch / S25C
B 2-inch / 304 SST S - - - 2 B - / 2-inch / 304 SST
C 2-inch / 316 SST S - - - 2 C - / 2-inch / 316 SST
D 3-inch / S25C S - - - 3 A - / 3-inch / S25C
E 3-inch / 304 SST S - - - 3 B - / 3-inch / 304 SST
F 3-inch / 316 SST S - - - 3 C - / 3-inch / 316 SST
Process Connections
0 No connectors (Rc 1/4) S - 0 - - - / No connectors (Rc 1/4)
1 Rc 1/4 S - 1 - - - / Rc 1/4
2 Rc 1/2 S - 2 - - - / Rc 1/2
3 1/4 NPT S - 3 - - - / 1/4 NPT
4 1/2 NPT S - 4 - - - / 1/2 NPT
5 No connectors (Rc 1/2) S - 5 - - - / No connectors (Rc 1/2)
Bolts and Nuts Material
A SCM435 S - J - - - /
B SUS630 - G - - - /
C SUH660 - C - - - /
Installation
-9 Always 0 S - - 9 - - / Always 9
Electrical Connection
0 G 1/2 S - - 0 - - / G 1/2
2 1/2 NPT S - - 2 - - / 1/2 NPT
3 Pg 13.5 X - - - - / Not Avialable
4 M20 S - - 4 - - / M20
5 G 1/2 with Plug S - - 5 - - / G 1/2 with Plug
7 1/2 NPT with Plug S - - 7 - - / 1/2 NPT with Plug
8 Pg 13.5 with Plug X - - - - / Not Avialable
9 M20 with Plug S - - 9 - - / M20 with Plug
A G 1/2 with 316 SST Plug S - - A - - / G 1/2 with 316 SST Plug
C 1/2 NPT with 316 SST Plug S - - C - - / 1/2 NPT with 316 SST Plug
D M20 with 316 SST Plug S - - D - - / M20 with 316 SST Plug
Display
D Display S - - D - - / Display
E Display with switch S - - E - - / Display with switch
N No Display S - - N - - / No Display
Bracket
N None S - - N - - / None

EXAMPLE: EJA210E - J M S 4 G - 9 2 E N - W A1 3 B SW 0 - /

Continued on next page


Determine proper code per EJA-E GS to complete model code.

PCO-501
Original Issue April 2013
1st Edition April 2013
7

‫ ڰ‬EJA210A
Continue
Here

EJA210E
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
/FF1 FM Explosionproof S - - - -
/ FF1 FM Explosionproof
/FF15 FM Explosionproof (Fieldbus) S - - - -
/FS1 FM Intrinsically Safe S - - - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) S - - - - / FS15 FM Intrinsically Safe (Fieldbus)
/FU1 FM Combo S - - - - / FU1 FM Combo
/KF21 ATEX Flameproof S - - - - / KF22 ATEX Flameproof
/KS2 ATEX Intrinsically Safe S - - - - / KS21 ATEX Intrinsically Safe
/KS25 ATEX Intrinsically Safe (Fieldbus) S - - - - / KS26 ATEX Intrinsically Safe (Fieldbus)
/KU22 ATEX Combo S - - - - / KU22 ATEX Combo
/CF1 CSA Explosionproof S - - - -
/ CF1 CSA Explosionproof
/CF15 CSA Explosionproof (Fieldbus) S - - - -
/CS1 CSA Intrinsically Safe S - - - - / CS1 CSA Intrinsically Safe
/CU1 CSA Combo S - - - - / CU1 CSA Combo
/SU2 IECEx Combo U - - - - / SF2 IECEx Flameproof

EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - W A1 3 B 1 SW B 0 - A / FF1

Continued on next page

PCO-501
Original Issue April 2013
1st Edition April 2013
8

‫ ڰ‬EJA210A
Continue
Here

EJA210E
Painting (Option) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
/P1 Amp Cover Black S - - - - / P1 Amp Cover Black
/P2 Amp Cover Jade Green S - - - - / P2 Amp Cover Jade Green
/P7 Amp Cover Metallic Silver S - - - - / P7 Amp Cover Metallic Silver
/PR Amp and terminal Cover Red S - - - - / PR Amp and terminal Cover Red
/X1 Epoxy Paint U - - - - / X2 Anti-corrosion coating
Exterior Parts (Option)
/HC 316 SST Exterior Parts S - - - - / HC 316 SST Exterior Parts
Fluoro-rubber O-ring (Option)
/HE Fluoro-rubber O-ring S - - - - / HE Fluoro-rubber O-ring
Lightning Protector (Option)
/A Lightning Protector S - - - - / A Lightning Protector
Oil-prohibited use (Option)
/K1 Degrease S - - - - / K1 Degrease
/K2 Degrease with fluorinated oil fill S - - - - / K2 Degrease with fluorinated oil fill
/K5 Degrease with dehydration treat. S - - - - / K5 Degrease with dehydration treat.
/K6 Degrease, fluor. oil fill, & deh. S - - - - / K6 Degrease, fluor. oil fill, & deh.
Calibration Units (Option)
/D1 PSI S - - - - / D1 PSI
/D3 Bar S - - - - / D3 Bar
/D4 Kgf/cm² S - - - - / D4 Kgf/cm²
Sealing Treatment (Option)
/Y 630 SST Bolts sealed X - - - - / Not available
Serration (Option)
/Q No Serration S - - - 2 - / No Serration
Teflon Film (Option)
/T Teflon Film S - - - - / TF1 Teflon Film
Fast Response (Option)
/F1 Fast Response Z - - - - / Standard - No option code required
Analog Signal Options (Option)
/C1 Standard output, failure down S - - - - / C1 Standard output, failure down
/C2 Namur NE43 output, failure down S - - - - / C2 Namur NE43 output, failure dow
/C3 Namur NE43 output, failure up S - - - - / C3 Namur NE43 output, failure up
Stainless Steel Housing (Option)
/E1 Stainless Steel Housing S - - 2 - - / Stainless Steel Housing
Wired on Tag (Option)
/N4 Wired on Tag S - - - - / N4 Wired on tag
Fieldbus Options (Option)
/LC1 PID Control Z - - - - / Standard - No option code required
/EE Software Download S - - - - / EE Software Download
Data Configuration (Option)
/CA Hart Data Configuration S - - - - / CA Hart Data Configuration
Gold Plate (Option)
/A1 Gold Plate - - - - / A1 Gold Plate
Material Certificate (Option)
/M03 Material Certificate S - - - - / M0W Material Certification
/M13 Material Certificate S - - - - / M1W Material Certification
Pressure Test (Option)
/T31 Pressure Test S - - - - / T51 Pressure Test
/T32 Pressure Test S - - - - / T54 Pressure Test
/T36 Pressure Test S - - - - / T52 Pressure Test
/T37 Pressure Test S - - - - / T56 Pressure Test
/T38 Pressure Test S - - - - / T55 Pressure Test

EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - W A1 3 B 1 SW B 0 - A / FF1 / TF1 / D1

Model code complete!

PCO-501
Original Issue April 2013
1st Edition April 2013
9

‫ ڰ‬EJA220A
.
Start
Here

EJA210E
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
EJA220A Flange Mounted DP Transmitter S EJA210E - S - - E 0 - / Flange Mounted DP Transmitter
Output Signal
-D 4 to 20 mA with BRAIN S - D - - - / 4 to 20 mA with BRAIN
-E 4 to 20 mA with HART 5 S - J - - - / 4 to 20 mA with HART 5/7
-F FOUNDATION Fieldbus S - F - - - / FOUNDATION Fieldbus
-G PROFIBUS PA X - - - - / Future Option
Measurement Span (Capsule)
M 4 to 400 inHЇK S - M - - - / 4 to 400 inHЇK
H 20 to 2,000 onHЇK S - H - - - / 20 to 2,000 onHЇK
Wetted Parts Material
S 316L SST / 316 SST S - - - SE - / 316L SST / 316 SST
W Hastelloy / 316 SST S - - - WE - / Hastelloy / 316 SST
Process Flange Rating
J1 JIS 10K S - - - J1 - / JIS 10K
J2 JIS 20K S - - - J2 - / JIS 20K
A1 ANSI Class 150 S - - - A1 - / ANSI Class 150
A2 ANSI Class 300 S - - - A2 - / ANSI Class 300
D2 DIN PN10/16 S - - - P1 - / DIN PN10/16
D4 DIN PN25/40 S - - - P2 - / DIN PN25/40
P1 JPI Class 150 S - - - D2 - / JPI Class 150
P2 JPI Class 300 S - - - D4 - / JPI Class 300
Extension
2 50mm S - - - 1 - / 50mm
4 100mm S - - - 3 - / 100mm
6 150mm S - - - 5 - / 150mm
Process Flange Size / Material
G 4-inch / S25C S - - - 4 A - / 4-inch / S25C
H 4-inch / 304 SST S - - - 4 B - / 4-inch / 304 SST
J 4-inch / 316 SST S - - - 4 C - / 4-inch / 316 SST
D 3-inch / S25C S - - - 3 A - / 3-inch / S25C
E 3-inch / 304 SST S - - - 3 B - / 3-inch / 304 SST
F 3-inch / 316 SST S - - - 3 C - / 3-inch / 316 SST
Process Connections
0 No connectors (Rc 1/4) S - 0 - - - / No connectors (Rc 1/4)
1 Rc 1/4 S - 1 - - - / Rc 1/4
2 Rc 1/2 S - 2 - - - / Rc 1/2
3 1/4 NPT S - 3 - - - / 1/4 NPT
4 1/2 NPT S - 4 - - - / 1/2 NPT
5 No connectors (Rc 1/2) S - 5 - - - / No connectors (Rc 1/2)
Bolts and Nuts Material
A SCM435 S - J - - - /
B SUS630 - G - - - /
C SUH660 - C - - - /
Installation
-9 Always 0 S - - 9 - - / Always 9
Electrical Connection
0 G 1/2 S - - 0 - - / G 1/2
2 1/2 NPT S - - 2 - - / 1/2 NPT
3 Pg 13.5 X - - - - / Not Avialable
4 M20 S - - 4 - - / M20
5 G 1/2 with Plug S - - 5 - - / G 1/2 with Plug
7 1/2 NPT with Plug S - - 7 - - / 1/2 NPT with Plug
8 Pg 13.5 with Plug X - - - - / Not Avialable
9 M20 with Plug S - - 9 - - / M20 with Plug
A G 1/2 with 316 SST Plug S - - A - - / G 1/2 with 316 SST Plug
C 1/2 NPT with 316 SST Plug S - - C - - / 1/2 NPT with 316 SST Plug
D M20 with 316 SST Plug S - - D - - / M20 with 316 SST Plug
Display
D Display S - - D - - / Display
E Display with switch S - - E - - / Display with switch
N No Display S - - N - - / No Display
Bracket
N None S - - N - - / None

EXAMPLE: EJA210E - J M S 4 G - 9 2 E N - E A1 3 B SE 0 1 - /

Continued on next page


Determine proper code per EJA-E GS to complete model code.

PCO-501
Original Issue April 2013
1st Edition April 2013
10

‫ ڰ‬EJA220A
Continue
Here

EJA210E
Transmitter Type (Pressure Type) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
/FF1 FM Explosionproof S - - - -
/ FF1 FM Explosionproof
/FF15 FM Explosionproof (Fieldbus) S - - - -
/FS1 FM Intrinsically Safe S - - - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) S - - - - / FS15 FM Intrinsically Safe (Fieldbus)
/FU1 FM Combo S - - - - / FU1 FM Combo
/KF21 ATEX Flameproof S - - - - / KF22 ATEX Flameproof
/KS2 ATEX Intrinsically Safe S - - - - / KS21 ATEX Intrinsically Safe
/KS25 ATEX Intrinsically Safe (Fieldbus) S - - - - / KS26 ATEX Intrinsically Safe (Fieldbus)
/KU22 ATEX Combo S - - - - / KU22 ATEX Combo
/CF1 CSA Explosionproof S - - - -
/ CF1 CSA Explosionproof
/CF15 CSA Explosionproof (Fieldbus) S - - - -
/CS1 CSA Intrinsically Safe S - - - - / CS1 CSA Intrinsically Safe
/CU1 CSA Combo S - - - - / CU1 CSA Combo
/SU2 IECEx Combo U - - - - / SF2 IECEx Flameproof

EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - E A1 3 B 1 SE 0 1 - A / FF1

Continued on next page

PCO-501
Original Issue April 2013
1st Edition April 2013
11

‫ ڰ‬EJA220A
Continue
Here

EJA210E
Painting (Option) EJA210E - X X X X X - X X X X X - X X X X X X X X - X / …
/P1 Amp Cover Black S - - - - / P1 Amp Cover Black
/P2 Amp Cover Jade Green S - - - - / P2 Amp Cover Jade Green
/P7 Amp Cover Metallic Silver S - - - - / P7 Amp Cover Metallic Silver
/PR Amp and terminal Cover Red S - - - - / PR Amp and terminal Cover Red
/X1 Epoxy Paint U - - - - / X2 Anti-corrosion coating
Exterior Parts (Option)
/HC 316 SST Exterior Parts S - - - - / HC 316 SST Exterior Parts
Fluoro-rubber O-ring (Option)
/HE Fluoro-rubber O-ring S - - - - / HE Fluoro-rubber O-ring
Lightning Protector (Option)
/A Lightning Protector S - - - - / A Lightning Protector
Oil-prohibited use (Option)
/K1 Degrease S - - - - / K1 Degrease
/K2 Degrease with fluorinated oil fill S - - - - / K2 Degrease with fluorinated oil fill
/K5 Degrease with dehydration treat. S - - - - / K5 Degrease with dehydration treat.
/K6 Degrease, fluor. oil fill, & deh. S - - - - / K6 Degrease, fluor. oil fill, & deh.
Calibration Units (Option)
/D1 PSI S - - - - / D1 PSI
/D3 Bar S - - - - / D3 Bar
/D4 Kgf/cm² S - - - - / D4 Kgf/cm²
Sealing Treatment (Option)
/Y 630 SST Bolts sealed X - - - - / Not available
Serration (Option)
/Q No Serration S - - - 2 - / No Serration
Fast Response (Option)
/F1 Fast Response Z - - - - / Standard - No option code required
Analog Signal Options (Option)
/C1 Standard output, failure down S - - - - / C1 Standard output, failure down
/C2 Namur NE43 output, failure down S - - - - / C2 Namur NE43 output, failure dow
/C3 Namur NE43 output, failure up S - - - - / C3 Namur NE43 output, failure up
Stainless Steel Housing (Option)
/E1 Stainless Steel Housing S - - 2 - - / Stainless Steel Housing
Wired on Tag (Option)
/N4 Wired on Tag S - - - - / N4 Wired on tag
Fieldbus Options (Option)
/LC1 PID Control Z - - - - / Standard - No option code required
/EE Software Download S - - - - / EE Software Download
Data Configuration (Option)
/CA Hart Data Configuration S - - - - / CA Hart Data Configuration
Gold Plate (Option)
/A1 Gold Plate - - - - / A1 Gold Plate
Material Certificate (Option)
/M04 Material Certificate S - - - - / M0E Material Certification
/M14 Material Certificate S - - - - / M1E Material Certification
Pressure Test (Option)
/T31 Pressure Test S - - - - / T51 Pressure Test
/T32 Pressure Test S - - - - / T54 Pressure Test
/T36 Pressure Test S - - - - / T52 Pressure Test
/T37 Pressure Test S - - - - / T56 Pressure Test
/T38 Pressure Test S - - - - / T55 Pressure Test

EXAMPLE: EJA210E - J M S 4 G - 9 1 2 E N - E A1 3 B 1 SE 0 1 - A / FF1 / C1 / D1

Model code complete!

PCO-501
Original Issue April 2013
1st Edition April 2013
12

‫ ڰ‬EJA310A, EJA430A, and EJA440A


Start
Here

EJA310E

EJA430E

EJA440E
Transmitter Type (Pressure Type) EJAxxxE - X X X X X - X X X X X / ….
EJA310A Absolute Pressure S EJA310E - - / Absolute Pressure
EJA430A Gauge Pressure S EJA430E - - / Gauge Pressure
EJA440A Gauge Pressure S EJA440E - - / Gauge Pressure
Output Signal
-D 4 to 20 mA with BRAIN S S S - D - / 4 to 20 mA with BRAIN
-E 4 to 20 mA with HART 5 S S S - J - / 4 to 20 mA with HART 5/7
-F FOUNDATION Fieldbus S S S - F - / FOUNDATION Fieldbus
-G PROFIBUS PA X X X - - / Future Option
Measurement Span (Capsule)
L 0.2 to 2.95 inHg S X X - L - / 0.2 to 2.95 inHg
M 0.38 to 28 inHg S X X - M - / 0.39 to 38 inHg
A 4.3 to 430 psi S S X - A - / 4.3 to 500 psi
B 20 to 2,000 psi S S X - B - / 20 to 2,300 psi
C 720 to 4,500 psi X X S - C - / 720 to 4,500 psi
D 720 to 7,200 psi X X S - D - / 720 to 7,200 psi
Wetted Parts Material
S Hastelloy / 316 SST / 316 SST S S S - S - / Hastelloy / 316 SST / 316 SST
H Hastelloy / Hastelloy / 316 SST X S X - H - / Hastelloy / Hastelloy / 316 SST
M Monel / Monel / 316 SST X S X - M - / Monel / Monel / 316 SST
T Tantalum / Tantalum / 316 SST X S X - T - / Tantalum / Tantalum / 316 SST
A Hastelloy / Hastelloy / Hastelloy X S X - A - / Hastelloy / Hastelloy / Hastelloy
D Tantalum / Hastelloy / Hastelloy X S X - D - / Tantalum / Hastelloy / Hastelloy
B Monel / Monel /Monel X S X - B - / Monel / Monel /Monel
Process Connections
0 No connectors (Rc 1/4) S S S - 0 - / No connectors (Rc 1/4)
1 Rc 1/4 S S S - 1 - / Rc 1/4
2 Rc 1/2 S S S - 2 - / Rc 1/2
3 1/4 NPT S S S - 3 - / 1/4 NPT
4 1/2 NPT S S S - 4 - / 1/2 NPT
5 No connectors (Rc 1/2) S S S - 5 - / No connectors (Rc 1/2)
Bolts
A SCM435 S S S - J - / B7 Carbon Steel
B SUS630 S S S - G - / 316L SST
C SUH660 S S S - C - / 660 SST
Installation
-2 Vertical RSHP PCU U U U - - 7 / Vertical LSHP PCD
-3 Vertical RSHP PCD U U U - - 7 / Vertical LSHP PCD
-6 Vertical LSHP PCU U U U - - 7 / Vertical LSHP PCD
-7 Vertical LSHP PCD S S S - - 7 / Vertical LSHP PCD
-8 Horizontal RSHP S S S - - 8 / Horizontal RSHP
-9 Horizontal LSHP S S S - - 9 / Horizontal LSHP
Electrical Connection
0 G 1/2 S S S - - 0 / G 1/2
2 1/2 NPT S S S - - 2 / 1/2 NPT
3 Pg 13.5 X X X - - / Not Avialable
4 M20 S S S - - 4 / M20
5 G 1/2 with Plug S S S - - 5 / G 1/2 with Plug
7 1/2 NPT with Plug S S S - - 7 / 1/2 NPT with Plug
8 Pg 13.5 with Plug X X X - - / Not Avialable
9 M20 with Plug S S S - - 9 / M20 with Plug
A G 1/2 with 316 SST Plug S S S - - A / G 1/2 with 316 SST Plug
C 1/2 NPT with 316 SST Plug S S S - - C / 1/2 NPT with 316 SST Plug
D M20 with 316 SST Plug S S S - - D / M20 with 316 SST Plug
Display
D Display S S S - - D / Display
E Display with switch S S S - - E / Display with switch
N No Display S S S - - N / No Display
Bracket
A Flat (CS) U U U - - B / Flat (304 SST)
B Flat (304 SST) S S S - - B / Flat (304 SST)
J Flat (316 SST) S S S - - J / Flat (316 SST)
C L-type (CS) U U U - - D / L-Type (304 SST)
D L-Type (304 SST) S S S - - D / L-Type (304 SST)
K L-Type (316 SST) S S S - - K / L-Type (316 SST)
N None S S S - - N / None

EXAMPLE: EJA430E - J B S 5 G - 9 2 E N /

Continued on next page Determine Amplifier Housing Material code per EJA-E GS to complete model code.

PCO-501
Original Issue April 2013
1st Edition April 2013
13

‫ ڰ‬EJA310A, EJA430A, and EJA440A


Continue
Here

EJA310E

EJA430E

EJA440E
Agency Approvals (Optional) EJAxxxE - X X X X X - X X X X X / ….
/FF1 FM Explosionproof - -
S S S / FF1 FM Explosionproof
/FF15 FM Explosionproof (Fieldbus) - -
/FS1 FM Intrinsically Safe S S S - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) S S S - - / FS15 FM Intrinsically Safe (Fieldbus)
/FU1 FM Combo S S S - - / FU1 FM Combo
/KF21 ATEX Flameproof S S S - - / KF22 ATEX Flameproof
/KS2 ATEX Intrinsically Safe S S S - - / KS21 ATEX Intrinsically Safe
/KS25 ATEX Intrinsically Safe (Fieldbus) S S S - - / KS26 ATEX Intrinsically Safe (Fieldbus)
/KU22 ATEX Combo S S S - - / KU22 ATEX Combo
/CF1 CSA Explosionproof - -
S S S / CF1 CSA Explosionproof
/CF15 CSA Explosionproof (Fieldbus) - -
/CS1 CSA Intrinsically Safe S S S - - / CS1 CSA Intrinsically Safe
/CU1 CSA Combo S S S - - / CU1 CSA Combo
/SU2 IECEx Combo U U U - - / SF2 IECEx Flameproof

EXAMPLE: EJA430E - J B S 5 G - 9 1 2 E N / FF1

Continued of next page

PCO-501
Original Issue April 2013
1st Edition April 2013
14

‫ ڰ‬EJA310A, EJA430A, and EJA440A


Continue
Here

EJA310E

EJA430E

EJA440E
High Accuracy (Option) EJAxxxE - X X X X X - X X X X X / ….
/HAC High Accuracy X S X - - / HAC High Accuracy
Painting (Option)
/P1 Amp Cover Black S S S - - / P1 Amp Cover Black
/P2 Amp Cover Jade Green S S S - - / P2 Amp Cover Jade Green
/P7 Amp Cover Metallic Silver S S S - - / P7 Amp Cover Metallic Silver
/PR Amp and terminal Cover Red S S S - - / PR Amp and terminal Cover Red
/X1 Epoxy Paint S S S - - / X2 Anti-corrosion Paint
316 SST Exterior Parts (Option)
/HC 316 SST Exterior Parts S S S - - / HC 316 SST Exterior Parts
Fluoro-rubber O-ring (Option)
/HE Fluoro-rubber O-ring S S S - - / HE Fluoro-rubber O-ring
Lightning Protector (Option)
/A Lightning Protector S S S - - / A Lightning Protector
Oil-prohibited use (Option)
/K1 Degrease S S S - - / K1 Degrease
/K2 Degrease with fluorinated oil fill S S S - - / K2 Degrease with fluorinated oil fill
/K5 Degrease with dehydration treatment S S S - - / K5 Degrease with dehydration treatment
/K6 Degrease, fluorinated oil fill, & deh. S S S - - / K6 Degrease, fluorinated oil fill, & deh.
Calibration Units (Option)
/D1 PSI S S S - - / D1 PSI
/D3 Bar S S S - - / D3 Bar
/D4 Kgf/cm² S S S - - / D4 Kgf/cm²
Sealing Treatment (Option)
/Y Sealing Treatment on 630 SST Bolts X X X - - / Not avialable
Long Vent (Option)
/U Long Vent S S S - - / U1 Long Vent
Fast Response (Option)
/F1 Fast Response Z Z Z - - / Standard - no option code required
Analog Signal Options (Option)
/C1 Standard output, failure down-scale S S S - - / C1 Standard output, failure down-scale
/C2 Namur NE43 output, failure down-scale S S S - - / C2 Namur NE43 output, failure down-scale
/C3 Namur NE43 output, failure up-scale S S S - - / C3 Namur NE43 output, failure up-scale
Stainless Steel Housing (Option)
/E1 Stainless Steel Housing S S S - - 2 / Stainless Steel Housing
Gold Plated Diaphragm (Option)
/A1 Gold Plated Diaphragm S X S - - / A1 Gold Plated Diaphragm
Custom Software (Option)
/R1 Custom Software X X X - - / Not avialable
Body Options (Option)
/N1 No drain or vent plugs S S S - - / N1 No drain or vent plugs
/N2 N1 with kidney flange S S S - - / N2 N1 with kidney flange
/N3 N2 with material certs S S S - - / N3 N2 with material certs
Wired on Tag (Option)
/N4 Wired on Tag S S S - - / N4 Wired on Tag
Low volume cover flange (Option)
/N5 For remote seal attachment X S X - W - / For remote seal attachment
Fieldbus Options (Option)
/LC1 PID Control Z Z Z - - / Standard - no option code required
/EE Software Download S S S - - / EE Software Download
Data Configuration (Option)
/CA Hart Data Configuration S S S - - / CA Hart Data Configuration
PED (Option)
/PED PED X X S - - / PE3 PED
Material Certificate (Option)
/M01 Material Certificate S S S - - / M01 Material Certification
/M11 Material Certificate S S S - - / M11 Material Certification
Pressure Test (Option)
/T02 Pressure Test X S X - - / T12 Pressure Test
/T03 Pressure Test S S X - - / T01 Pressure Test
/T04 Pressure Test S X X - - / T04 Pressure Test
/T08 Pressure Test X X S - - / T08 Pressure Test
/T09 Pressure Test X X S - - / T09 Pressure Test

EXAMPLE: EJA430E - J B S 5 G - 9 2 2 E N / FF1 / HG / M01 / T09 / D1

Model code complete!

PCO-501
Original Issue April 2013
1st Edition April 2013
15

‫ ڰ‬EJA510A and EJA530A


Start
Here

EJA510E

EJA530E
Transmitter Type (Pressure Type) EJAxxxE - X X X X X - X X X X X / ….
EJA510A Absolute Pressure S EJA510E - - / Absolute Pressure
EJA530A Gauge Pressure S EJA530A - - / Gauge Pressure
Output Signal
-D 4 to 20 mA with BRAIN S S - D - / 4 to 20 mA with BRAIN
-E 4 to 20 mA with HART 5 S S - J - / 4 to 20 mA with HART 5/7
-F FOUNDATION Fieldbus S S - F - / FOUNDATION Fieldbus
-G PROFIBUS PA X X - - / Future Option
Measurement Span (Capsule)
A 1.45 to 29 psi S S - A - / 1.45 to 29 psi
B 14.5 to 290 psi S S - B - / 14.5 to 290 psi
C 72.5 to 1,450 psi S S - C - / 72.5 to 1,450 psi
D 720 to 7,200 psi S S - D - / 720 to 7,200 psi
Wetted Parts Material
S Hastelloy / 316 SST / 316 SST S S - S - / Hastelloy / 316 SST / 316 SST
H Hastelloy / Hastelloy / 316 SST S S - H - / Hastelloy / Hastelloy / 316 SST
Process Connections
4 1/2-inch FNPT S S - 4 - / 1/2-inch FNPT
7 1/2-inch MNPT S S - 7 - / 1/2-inch MNPT
8 G 1/2 DIN 16 288 Male S S - 8 - / G 1/2 DIN 16 288 Male
9 M20 x 1.5 DIN 16 288 male S S - 9 - / M20 x 1.5 DIN 16 288 male
Always N
N Always N S S - N - / Always N
Installation
-0 Always 0 S S - - 0 / Always 0
Electrical Connection
0 G 1/2 S S - - 0 / G 1/2
2 1/2 NPT S S - - 2 / 1/2 NPT
3 Pg 13.5 X X - - / Not Avialable
4 M20 S S - - 4 / M20
5 G 1/2 with Plug S S - - 5 / G 1/2 with Plug
7 1/2 NPT with Plug S S - - 7 / 1/2 NPT with Plug
8 Pg 13.5 with Plug X X - - / Not Avialable
9 M20 with Plug S S - - 9 / M20 with Plug
A G 1/2 with 316 SST Plug S S - - A / G 1/2 with 316 SST Plug
C 1/2 NPT with 316 SST Plug S S - - C / 1/2 NPT with 316 SST Plug
D M20 with 316 SST Plug S S - - D / M20 with 316 SST Plug
Display
D Display S S - - D / Display
E Display with switch S S - - E / Display with switch
N No Display S S - - N / No Display
Bracket
E Carbon Steel U U - - L / 316 SST
F 304 SST U U - - L / 316 SST
L 316 SST S S - - L / 316 SST
N None S S - - N / None

EXAMPLE: EJA530E - J B S 4 N - 0 2 E N /

Continued on next page Determine Amplifier Housing Material code per EJA-E GS to complete model code.

PCO-501
Original Issue April 2013
1st Edition April 2013
16

‫ ڰ‬EJA510A and EJA530A


Continue
Here

EJA510E

EJA530E
Agency Approvals (Optional) EJAxxxE - X X X X X - X X X X X / ….
/FF1 FM Explosionproof - -
S S / FF1 FM Explosionproof
/FF15 FM Explosionproof (Fieldbus) - -
/FS1 FM Intrinsically Safe S S - - / FS1 FM Intrinsically Safe
/FS15 FM Intrinsically Safe (Fieldbus) S S - - / FS15 FM Intrinsically Safe (Fieldbus)
/FU1 FM Combo S S - - / FU1 FM Combo
/KF21 ATEX Flameproof S S - - / KF22 ATEX Flameproof
/KS2 ATEX Intrinsically Safe S S - - / KS21 ATEX Intrinsically Safe
/KS25 ATEX Intrinsically Safe (Fieldbus) S S - - / KS26 ATEX Intrinsically Safe (Fieldbus)
/KU22 ATEX Combo S S - - / KU22 ATEX Combo
/CF1 CSA Explosionproof - -
S S / CF1 CSA Explosionproof
/CF15 CSA Explosionproof (Fieldbus) - -
/CS1 CSA Intrinsically Safe S S - - / CS1 CSA Intrinsically Safe
/CU1 CSA Combo S S - - / CU1 CSA Combo
/SU2 IECEx Combo U U - - / SF2 IECEx Flameproof

EXAMPLE: EJA530E - J B S 4 N - 0 1 2 E N / FF1

Continued on next page

PCO-501
Original Issue April 2013
1st Edition April 2013
17

ඵEJA510A and EJA530A


Continue
Here

EJA510E

EJA530E
High Accuracy (Option) EJAxxxE - X X X X X - X X X X X / ….
/HAC ,ŝŐŚĐĐƵƌĂĐLJ S S - - / HAC ,ŝŐŚĐĐƵƌĂĐLJ
Painting (Option)
/P1 ŵƉŽǀĞƌůĂĐŬ S S - - / P1 ŵƉŽǀĞƌůĂĐŬ
/P2 ŵƉŽǀĞƌ:ĂĚĞ'ƌĞĞŶ S S - - / P2 ŵƉŽǀĞƌ:ĂĚĞ'ƌĞĞŶ
/P7 ŵƉŽǀĞƌDĞƚĂůůŝĐ^ŝůǀĞƌ S S - - / P7 ŵƉŽǀĞƌDĞƚĂůůŝĐ^ŝůǀĞƌ
/PR ŵƉĂŶĚƚĞƌŵŝŶĂůŽǀĞƌZĞĚ S S - - / PR ŵƉĂŶĚƚĞƌŵŝŶĂůŽǀĞƌZĞĚ
/X1 ƉŽdžLJWĂŝŶƚ U U - - / X2 ŶƚŝͲĐŽƌƌŽƐŝŽŶWĂŝŶƚ
Fluoro-rubber O-ring (Option)
/HE &ůƵŽƌŽͲƌƵďďĞƌKͲƌŝŶŐ S S - - / HE &ůƵŽƌŽͲƌƵďďĞƌKͲƌŝŶŐ
Lightning Protector (Option)
/A >ŝŐŚƚŶŝŶŐWƌŽƚĞĐƚŽƌ S S - - / A >ŝŐŚƚŶŝŶŐWƌŽƚĞĐƚŽƌ
Oil-prohibited use (Option)
/K1 ĞŐƌĞĂƐĞ S S - - / K1 ĞŐƌĞĂƐĞ
/K2 ĞŐƌĞĂƐĞǁŝƚŚĨůƵŽƌŝŶĂƚĞĚŽŝůĨŝůů S S - - / K2 ĞŐƌĞĂƐĞǁŝƚŚĨůƵŽƌŝŶĂƚĞĚŽŝůĨŝůů
Calibration Units (Option)
/D1 W^/ S S - - / D1 W^/
/D3 Ăƌ S S - - / D3 Ăƌ
/D4 <ŐĨͬĐŵ² S S - - / D4 <ŐĨͬĐŵ²
Fast Response (Option)
/F1 &ĂƐƚZĞƐƉŽŶƐĞ Z Z - - / StandardͲŶŽŽƉƚŝŽŶĐŽĚĞƌĞƋƵŝƌĞĚ
Analog Signal Options (Option)
/C1 ^ƚĂŶĚĂƌĚŽƵƚƉƵƚ͕ĨĂŝůƵƌĞĚŽǁŶͲƐĐĂůĞ S S - - / C1 ^ƚĂŶĚĂƌĚŽƵƚƉƵƚ͕ĨĂŝůƵƌĞĚŽǁŶͲƐĐĂůĞ
/C2 EĂŵƵƌEϰϯŽƵƚƉƵƚ͕ĨĂŝůƵƌĞĚŽǁŶͲƐĐĂůĞ S S - - / C2 EĂŵƵƌEϰϯŽƵƚƉƵƚ͕ĨĂŝůƵƌĞĚŽǁŶͲƐĐĂůĞ
/C3 EĂŵƵƌEϰϯŽƵƚƉƵƚ͕ĨĂŝůƵƌĞƵƉͲƐĐĂůĞ S S - - / C3 EĂŵƵƌEϰϯŽƵƚƉƵƚ͕ĨĂŝůƵƌĞƵƉͲƐĐĂůĞ
Stainless Steel Housing (Option)
/E1 ^ƚĂŝŶůĞƐƐ^ƚĞĞů,ŽƵƐŝŶŐ S S - - 2 / ^ƚĂŝŶůĞƐƐ^ƚĞĞů,ŽƵƐŝŶŐ
Wired on Tag (Option)
/N4 tŝƌĞĚŽŶdĂŐ S S - - / N4 tŝƌĞĚŽŶdĂŐ
Fieldbus Options (Option)
/LC1 W/ŽŶƚƌŽů Z Z - - / StandardͲŶŽŽƉƚŝŽŶĐŽĚĞƌĞƋƵŝƌĞĚ
/EE ^ŽĨƚǁĂƌĞŽǁŶůŽĂĚ S S - - / EE ^ŽĨƚǁĂƌĞŽǁŶůŽĂĚ
Data Configuration (Option)
/CA ,ĂƌƚĂƚĂŽŶĨŝŐƵƌĂƚŝŽŶ S S - - / CA ,ĂƌƚĂƚĂŽŶĨŝŐƵƌĂƚŝŽŶ
PED (Option)
/PE3 W X X - - / PE3 W
Material Certificate (Option)
/M15 DĂƚĞƌŝĂůĞƌƚŝĨŝĐĂƚĞ S S - - / M15 DĂƚĞƌŝĂůĞƌƚŝĨŝĐĂƚŝŽŶ
Pressure Test (Option)
/T05 WƌĞƐƐƵƌĞdĞƐƚ S S - - / T05 WƌĞƐƐƵƌĞdĞƐƚ
/T06 WƌĞƐƐƵƌĞdĞƐƚ S S - - / T06 WƌĞƐƐƵƌĞdĞƐƚ
/T07 WƌĞƐƐƵƌĞdĞƐƚ S S - - / T07 WƌĞƐƐƵƌĞdĞƐƚ
/T08 WƌĞƐƐƵƌĞdĞƐƚ S S - - / T08 WƌĞƐƐƵƌĞdĞƐƚ

yDW>͗ EJA530E - J B S 4 N - 0 2 2 E N / FF1 / HE / M15 / T06 / D1

Model code complete!

PCO-501
Original Issue April 2013
1st Edition April 2013
18

This Page Blank

2 Dart Road
Newnan, GA 30265

PCO-501
Original Issue April 2013
1st Edition April 2013