RNC6 ES

HEAT RECOVERY VENTILATOR

ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED DEFROST
ALUMINUM CORE Recirculating damper defrost system.
The cross-flow heat recovery core transfers heat between the two airstreams.
It is easily removed for cleaning or service. CASE
Twenty gauge prepainted galvanized steel for superior corrosion resistance.
MOTORS AND BLOWERS Insulated to prevent exterior condensation. Drain connections 2 - 1/2 in. (12 mm) OD.
Each airstream has one motorized impeller with multiple fan speed operations. Balancing ports are located on door.

FILTERS INSTALLER SELECTABLE HIGH SPEED SETTINGS


Washable air filters in exhaust and supply airstreams. Adjustable DIP switches are located on the circuit board, Hi3 is the factory setting.
Upgrade to MERV-13 option available. . Refer to the Installation manual for the adjustment instructions.

MOUNTING ELECTRONICS
Four threaded inserts at corners of the cabinet designed to accept the The optional control can be wall mounted in a central location of the home.
“S” hooks and hanging straps supplied with the unit. 3 wire 20 gauge (min.) 100 ft length (max.).

OPTIONAL ACCESSORIES:
Dual Hood Weather Hood TechGrille Terminator
99-190 99-185 99-EAG4 Fitting
99-194 99-186 99-EAG5 99-TM4
99-187 99-EAG6 99-TM5
99-EAG8 99-TM6

LIFEBREATH CONTROL OPTIONS TIMER OPTIONS


99-DET01 - Lifebreath 20/40/60 Minute Timer
FEATURES 99-DXPL02 99-BC02 99-BC03 99-BC04
Initiates high speed Ventilation for 20, 40 or 60 minutes. 3 wire
connection.
5 speed fan operation on each mode 
  99-DET02 - Wireless Lifebreath 20/40/60 Minute Timer
2 speed fan operation (Low/High)
Initiates high speed Ventilation for 20, 40 or 60 minutes. Wirelessly
Continuous low speed fan operation     connects to main control for ease of installation. 40’ approximate range.
Exclusive to Lifebreath.
Humidity control through adjustable Dehumid-   
istat 99-RX02 - Wireless Lifebreath Repeater
Large digital LCD screen  Extends range of 99-DET02 Wireless Timers. Plugs into 120V power
outlet. Wirelessly connects to main control and 99- DET02. Install at
LED status indicator lights    halfway point between timer and main wall control if timer is out of
range.
Continuous Ventilation    
Continuous Recirculation  
20 ON/40 OFF   
10 ON/50 OFF 
20 ON/40 Recirculation   
99-BC02 99-BC03 99-BC04 99-DET02 99-DET01
20/40/60 min. High speed override button 
Compatible with 99-DET02 Wireless Timer    
3 wire connection    

69-RNC6 ES (0921) www.lifebreath.com


RNC6 ES
HEAT RECOVERY VENTILATOR

PERFORMANCE (HVI CERTIFIED)

0.2 (50) 0.3 (75) 0.4 (100) 0.5 (125) 0.6 (150) 0.7 (175) 0.8 (200) 0.9 (225) ELECTRICAL SPECIFICATIONS
IN. W.G. (PA)
CFM (L/s) CFM (L/s) CFM (L/s) CFM (L/s) CFM (L/s) CFM (L/s) CFM (L/s) CFM (L/s)
VAC @ 60Hz 115

Net Supply Airflow 176 (83) 164 (77) 152 (72) 140 (66) 128 (61) 116 (55) 103 (49) 89 (42) Watts / Low Speed 48

Gross Supply Airflow 179 (85) 167 (79) 155 (73) 143 (68) 131 (62) 118 (56) 105 (50) 91 (43) Watts / High Speed 74

Gross Exhaust Airflow 171 (81) 159 (75) 148 (70) 136 (64) 124 (59) 111 (52) 98 (46) 83 (39) Amp Rating 1.25

Sensible Effectiveness (ASE)


180
H3
WEIGHT:
@ 64 CFM (30 L/s)
32°F (0°C) 73% 51 LBS (23 KG)
160
Sensible Efficiency (SRE)
140
H2 SHIPPING WEIGHT:
@ 64 CFM (30 L/s)
32°F (0°C) 65%
H1 54 LBS (25 KG)
Airflow (cfm)

120
Sensible Efficiency (SRE)
-13°F (-25°C) 60%
@ 71 CFM (33 L/s) 100
NOTE:
80 Front clearance of 25 in. (635 mm)
Low
60 is recommended for servicing unit.
Round duct connections are 5 in. (127
40 mm) and oval collars use 6 in. (152 mm)
20 connections.

MERV 13 Upgrade: 65-195-6R


0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Static Pressure (in w.g.)

DIMENSIONS
FRONT VIEW TOP VIEW
5 in.
(125 mm)
Collar size

Recirculating
Defrost Damper
14 in. (366 mm)

(For TPD Model Only)


17 1/4 in. (438 mm)

Filter

Removable Heat
Recovery Core

Stale air to outside

Motorized Fresh air from outside


Impeller Stale air from inside
Condensate 22 3/4 in. (578 mm)
Fresh air to inside
Drains

Date: Contractor: WARRANTY


Units carry a lifetime warranty
Tag: on the HRV core and a 5 year
Supplier:
replacement parts warranty.

Project: Qty: Quote #:


All units conform to CSA and UL standards
Engineer: Submitted By:

Control: Timer: Timer Qty:

69-RNC6 ES (0921) www.lifebreath.com