Mitsubishi Heat Pump Specs

This document provides submittal data for a 15,000 BTU/H wall-mounted heat pump system, including: - Electrical requirements of 208/230V, 1-Phase, 60 Hz with a recommended breaker size of 15A - Indoor unit dimensions of 11-5/8" x 31-7/16" x 9-1/8" and outdoor unit dimensions of 21-5/8" x 31-1/2" x 11-1/4" - Operating conditions and rated cooling and heating capacities between 3,100 to 18,200 BTU/h and 4,800 to 20,900 BTU/h respectively

Uploaded by

kamran shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views2 pages

Mitsubishi Heat Pump Specs

This document provides submittal data for a 15,000 BTU/H wall-mounted heat pump system, including: - Electrical requirements of 208/230V, 1-Phase, 60 Hz with a recommended breaker size of 15A - Indoor unit dimensions of 11-5/8" x 31-7/16" x 9-1/8" and outdoor unit dimensions of 21-5/8" x 31-1/2" x 11-1/4" - Operating conditions and rated cooling and heating capacities between 3,100 to 18,200 BTU/h and 4,800 to 20,900 BTU/h respectively

Uploaded by

kamran shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

M-SERIES

SUBMITTAL DATA: MSZ-*/1$8& MUZ-*/NA+82


,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM

-RE1DPH /RFDWLRQ 'DWH


3XUFKDVHU (QJLQHHU
6XEPLWWHGWR )RU5HIHUHQFH$SSURYDO&RQVWUXFWLRQ
6\VWHP'HVLJQDWLRQ 6FKHGXOH1R
(OHFWULFDO3RZHU
5HTXLUHPHQWV
93KDVH+]

0LQLPXP&LUFXLW$PSDFLW\ 0&$ *

,QGRRU2XWGRRU 5%6 A  $5HFRPPHQGHG%UHDNHU6L]H


Wireless Remote Controller
*All electrical work shall comply with National (CEC) and local codes and regulations.
,QGRRU8QLW

ACCESSORIES: %ORZHU0RWRU (&0 F.L.A. 


%ORZHU0RWRU2XWSXW W 
Indoor Unit
6+)0RLVWXUH5HPRYDO SWK
$QWL$OOHUJ\(Q]\PH)LOWHU 0$&)7(
)LHOG'UDLQSLSH6L]H2' In.(mm)  

Note: Mitsubishi Electric (MESCA) 2XWGRRU8QLW


Outdoor Unit supports the use of only MESCA supplied
and approved Snow Guard / Wind &RPSUHVVRU '&,19(57(5GULYHQ7ZLQ5RWDU\
:LQGVFUHHQV 0E-FR-12-17 Deflectors / Windscreens and accessories
for proper functioning of the unit(s). Use of )DQ0RWRU (&0 F.L.A. 

Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.
non-MESCA supported Snow Guard / Wind
Deflectors / Windscreens and accessories $LUÀRZ5DWH 4XLHW/R0HG+L6XSHU+L
will affect warranty coverage.
Controls
,QGRRU '5< 
:LUHOHVV&RQWUROOHU 0+. &RROLQJ :(7 
:LUHG5HPRWH&RQWUROOHU3$5400$$ 5HTXLUHV0$&4,)( CFM
,QGRRU
7KHUPRVWDW,QWHUIDFH 3$&86&1
+HDWLQJ
'5< 

2XWGRRU 
SPECIFICATIONS:
6RXQG3UHVVXUH/HYHO 4XLHW/R0HG+L6XSHU+L
5DWHG&RQGLWLRQV &DSDFLW\,QSXW
&RROLQJ 
&RROLQJ Btu/h / W  ,QGRRU
+HDWLQJ 
+HDWLQJDWº) Btu/h / W  dB(A)
&RROLQJ 
&DSDFLW\5DQJH 0LQLPXP 0D[LPXP 2XWGRRU
+HDWLQJ 
&RROLQJ Btu/h  
([WHUQDO'LPHQVLRQV
+HDWLQJDWº) Btu/h  
[[
+HDWLQJDWº) Btu/h   ,QGRRU +[:['
[[
+HDWLQJDWº) Btu/h   In.(mm)
[[
2XWGRRU +[:['

&RROLQJ_,QGRRUž) ž& '%ž) ž& :%2XWGRRUž) ž& '%ž) ž& :%* [[

+HDWLQJDWž)_,QGRRUž) ž& '%ž) ž& :%2XWGRRUž) ž& '%ž) ž& :%*

+HDWLQJDWž)_,QGRRUž) ž& '%ž) ž& :%2XWGRRUž) ž& '%ž) ž& :%*

+HDWLQJDWž)_,QGRRUž) ž& '%ž) ž& :%2XWGRRUž) ž& '%ž) ž& :% 1HW:HLJKW
*
5DWLQJ&RQGLWLRQVSHU$+5,6WDQGDUG
,QGRRU  
2SHUDWLQJ&RQGLWRQV ,QGRRU,QWDNH$LU7HPS  0D[0LQ Lbs.(kg)
2XWGRRU  
&RROLQJ ž) ž& '%ž) ž& '%
([WHUQDO)LQLVK
+HDWLQJ ž) ž& '%ž) ž& '%
,QGRRU 0XQVHOO<
2SHUDWLQJ&RQGLWRQV 2XWGRRU,QWDNH$LU7HPS  0D[0LQ
2XWGRRU 0XQVHOO1R<
&RROLQJ ) ž& '%ž) ž& '%
5HIULJHUDQW 5$OER]
+HDWLQJ ž) ž& '%ž) ž& '%

$SSOLFDWLRQVVKRXOGEHUHVWULFWHGWRFRPIRUWFRROLQJRQO\HTXLSPHQWFRROLQJDSSOLFDWLRQVDUHQRW 5HIULJHUDQW3LSLQJ )ODUHG
UHFRPPHQGHGIRUORZDPELHQWWHPSHUDWXUHFRQGLWLRQV
/LTXLG +LJK3UHVVXUH  
In.(mm)
$+5,(I¿FLHQF\5DWLQJV *DV /RZ3UHVVXUH  

6((5+63)((5  0D[7RWDO5HIULJHUDQW


3LSH/HQJWK +HLJKW'LII
 
&23DWR)R)  Ft. (m)
0D[7RWDO5HIULJHUDQW
3LSH/HQJWK /HQJWK
 
(QHUJ\6WDU® <HV
(1(5*<67$5SURGXFWVDUHWKLUGSDUW\FHUWL¿HGE\DQ(3$UHFRJQL]HG&HUWL¿FDWLRQ%RG\ 6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
‹70LWVXELVKL(OHFWULF6DOHV&DQDGD,QF 3DJHRI )RUP6%B06=*/1$8B08=*/1$+82B2005
DIMENSIONS: 06=*/1$8 08=*/1$+82
MSZ-*/1$8 8QLWLQ PP

Should this document be altered or changed without MESCA’s permission, it becomes null and void. MESCA assumes no responsibility for any consequences in such cases.
Insulation ¡2'

Piping
/LTXLGOLQH ¡ )ODUHGFRQQHFWLRQ¡
Gas line ¡
)ODUHGFRQQHFWLRQ¡ GL06/09/12NA ¡ GL15NA
Drain hose ,QVXODWLRQ¡2'&RQQHFWHGSDUW¡2'

MUZ-*/1$+8 REQUIRED SPACE 8QLWLQ PP


*1 4 in. (100 mm) or more when

clear *1
front and sides of the unit are clear

)
(GL09/12/15NA)
mm
(GL12/15NAH)
4 in (100 re
.( n. o
or 100 m 4 i or m
mo
re m)

m) 14
0m in.
(
holes n. (20 re *2 or m350 m
8 i r mo ore m)
o

*2 When any 2 sides of left, right


Liquid refrigerant pipe joint and rear of the unit are clear
Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 3/8 (GL09/12)
Ø 1/2 (GL15)

)RUP6%B06=*/1$8B08=*/1$+U2B2005
6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
ZZZ0LWVXELVKL(OHFWULFFD
‹70LWVXELVKL(OHFWULF6DOHV&DQDGD,QF 3DJHRI