0% found this document useful (0 votes)
116 views20 pages

High Flow NAMUR Valve G1/4" & G1/2": For Control of Pneumatic Actuators

Namur Valve

Uploaded by

Ion Floarea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
116 views20 pages

High Flow NAMUR Valve G1/4" & G1/2": For Control of Pneumatic Actuators

Namur Valve

Uploaded by

Ion Floarea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

aerospace

climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding

High Flow NAMUR Valve


G1/4" & G1/2"
for Control of Pneumatic Actuators
Market
Description
Process industries
Chemical, Petrochemical industries
Oil & Gas
Water & Sewage
Pulp & Paper
Food & Beverage
Pharmaceutical industry
Powder Dosing-Transportation
Air Dryers

Description
of Applications
Control of single or double acting pneumatic actuators,
in safe or dangerous areas.

NAMUR Interfaces
1/4" & 1/2"
D4
The interface design is conform to the NAMUR
D3
standard and to the VDI/VDE 3845 recommendations
F M
of the actuator industry. It allows a compact design
of the actuator/valve unit. In case of a 3/2 function, T
the air of the actuator spring chamber also flows
through the pilot valve (re-breather function). D1

This prevents corrosion of the actuator springs. "2" "4"

Ra 3.2
F T D1 D2 D3 D4 min. M D2
mm mm mm Mm mm
M5 1/4 32 24 8 12 M5
M6 1/2 45 40 10 16 M6 F: 2 mounting holes - T: 2 actuators control port - M: 2 holes for dowel pins

2 Catalogue 1101/UK - Ed. June 2010


Customer Value
Proposition
● High flow: 1.250 l/min (1/4"), 3.000 l/min (1/2")
● Compact design
● Long life expectancy
● N3x series compatible with any Parker Lucifer coil
(ATEX or not) of electrical group 2 (8/9 W coils)
● Fail safe standard
● Reduced inventory (3/2 & 5/2 functions with the same
valve on 341Nx5 series)
● Mechanical part of the valve ATEX certified according
standard EN 13463-1 & -5

General
Information
Function: 3/2 , 5/2, 3/2 <=> 5/2 and 5/3 valves.
Manual override: Standard on all versions.
Design: Solenoid operated spool valve with combined spring and air
return & external air pressure operated versions.
Mounting: For direct mounting on NAMUR interface ¼" & ½".
Mounting position: Indifferent.
Material specifications: Aluminium body. Internal parts from stainless steel.
Sealing material from NBR.
Range of admissible pressure drop: Δp min. = see table.
Δp max. = 10 bar.
Media: Dry or lubricated air.
Fluid temperature: Min. 0°C Max. + 50°C
Ambient temperature: -10°C to +50°C
Electrical part: N0x series are compatible with 22mm coil 496131 / 496482 / 496637 Series
N3x series are compatible with 32/37/40 mm coils part of electrical group 2 (8/9W),
including 481865 / 495870 / 495905 Series.
Solenoid duty: 100% ED.
Voltage: 481865 coil: 12 VDC , 24 VDC , 48 VDC , 110VDC, 24 V / 50 AC, 48 V / 50 AC,
110 V / 50 AC, 220-230V/50 AC, 115 V / 60 Hz AC, 230 V / 60 AC.
Voltage tolerance: ± 10% of nominal for 481865 coil.
Class of insulation material: Class F for 481865 coil.
Standards: Mechanical ATEX conform to EN 13463-1 & -5.

3 Catalogue 1101/UK - Ed. June 2010


G1/4" Series
Solenoid Operated Versions
N03-N05 Series with 22 mm Coil
Admissible Max. admissible
differential fluid
Port size Orifice QN pressure temperature Seat Reference Consumption Weight Dimensions
(bar) disc number Power (g) Reference
(ºC)
(Watt)
max. Min. = 0ºC

G mm L/min min DC= AC~ Air & Valve Housing Coil DC AC


Neutral gases

3/2 Solenoid operated - Combined spring & air return (monostable)


3 1
1/4 7 1250 2.5 10 10 50 NBR 331N03 - 496131 3 3 300 1
1/4 7 1250 2.5 10 10 50 NBR 331N03 - 496482 3 3 300 1
1/4 7 1250 2.5 10 10 50 NBR 331N03 - 496637 3 3 300 1

4 2

5/2 Solenoid operated - Combined spring & air return (monostable)


5 1 3
1/4 7 1250 2.5 10 10 50 NBR 341N03 - 496131 3 3 300 2
1/4 7 1250 2.5 10 10 50 NBR 341N03 - 496482 3 3 300 2
1/4 7 1250 2.5 10 10 50 NBR 341N03 - 496637 3 3 300 2

2 4 2

3/2 <=> 5/2 with conversion plate - Solenoid operated


Combined spring & air return (monostable) 3 1 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 341N05 - 496131 3 3 310 3
1/4 7 1250 2.5 10 10 50 NBR 341N05 - 496482 3 3 310 3
1/4 7 1250 2.5 10 10 50 NBR 341N05 - 496637 3 3 310 3

4 2

5/2 Solenoid operated and return (bistable)


5 1 3
1/4 7 1250 2.5 10 10 50 NBR 347N03 - 496131 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 347N03 - 496482 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 347N03 - 496637 3 3 430 4

4 2

5/3 W1 closed in center position - Solenoid operated and return


5 1 3
1/4 7 1250 2.5 10 10 50 NBR 342N03 - 496131 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 342N03 - 496482 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 342N03 - 496637 3 3 430 4

4 2

5/3 W3 exhausted in center position


Solenoid operated and return (bistable) 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 343N03 - 496131 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 343N03 - 496482 3 3 430 4
1/4 7 1250 2.5 10 10 50 NBR 343N03 - 496637 3 3 430 4

Please consult the "How to Order" part at the end of each coil chapter.

4 Catalogue 1101/UK - Ed. June 2010


Dimensions Reference 1 Dimensions Reference 2
50 50
67

67
32
40

32
40
12 10 14 12
3 2 4 2

23 24 23 23 24 23
36.5 86 36.5 86

13 44 13 13 44 13

3 1 5 3
22

22
7.2 7.2
G1/4" (2x) M5 G1/4" (3x) M5

Dimensions Reference 3 Dimensions Reference 4


50 50 50

67
67

67
32

32
40

40
14 12
4 2

23 24 23 23 24 23
36,5 90 102

13 22 22 13 13 44 13

5 3 5 3
22
22
32

7.2
7.2 G1/4" (3x) M5
G1/4" (3x) M5

5 Catalogue 1101/UK - Ed. June 2010


G1/4" Series
Solenoid Operated Versions
N33-N35 Series with 32 / 37 / 40 mm Coil
Admissible Max. admissible
differential fluid
Port size Orifice QN pressure temperature Seat Reference Consumption Weight Elect. Dim.
(bar) disc number Power (g) Group Ref.
(ºC)
(Watt)
max. Min. = 0ºC

G mm L/min min DC= AC~ Air & Valve Housing Coil DC AC


Neutral gases

2 4 2

3/2 <=> 5/2 with conversion plate - Solenoid operated


Combined spring & air return (monostable) 3 1 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 341N35 2995 481865 9 8 480 2 5
1/4 7 1250 2.5 10 10 50 NBR - 2995 495870 9 8 700 - 2
1/4 7 1250 2.5 10 10 50 NBR - - 495905 8 8 740 - 2
4 2

5/2 Solenoid operated and return (bistable)


5 1 3
1/4 7 1250 2.5 10 10 50 NBR 347N33 2995 481865 9 8 750 2 6
1/4 7 1250 2.5 10 10 50 NBR - 2995 495870 9 8 1190 2 -
1/4 7 1250 2.5 10 10 50 NBR - - 495905 8 8 1270 2 -

4 2

5/3 W1 closed in center position


Solenoid operated and return (bistable) 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 342N33 2995 481865 9 8 750 2 6
1/4 7 1250 2.5 10 10 50 NBR - 2995 495870 9 8 1190 2 -
1/4 7 1250 2.5 10 10 50 NBR - - 495905 8 8 1270 2 -

Dimensions Reference 5 Dimensions Reference 6


13 22 22 13
32

40
40
32

14 12
4 2

23 24 23 23 24 23

100 130
19.5 24 19.5 24

32 G1/8" 32 G1/8"

DIN 43650A DIN 43650A


38

38
97

87

13 22 22 13

5 3 5 3
22

22
32

7.2
G1/4" (3x) M5 7.5 G1/4" (3x) M5

Please consult the "How to Order" part at the end of each coil chapter.

6 Catalogue 1101/UK - Ed. June 2010


G1/4" Series
External Pressure Air Operated Series
5xx N03 Series
Admissible Max. admissible
differential fluid
Port size Orifice QN pressure temperature Seat Reference Consumption Weight Dimensions
(bar) disc number Power (g) Reference
(ºC)
(Watt)
max. Min. = 0ºC

G mm L/min min DC= AC~ Air & Valve Housing Coil DC AC


Neutral gases

2
3/2 External pressure air operated
Combined spring & air return (monostable)
External pressure supply 2.5 to 10 bar 3 1
1/4 7 1250 2.5 10 10 50 NBR 531N03 - w/o - - 210 7

4 2
5/2 external pressure air operated
Combined spring & air return (monostable)
External pressure supply 2.5 to 10 bar 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 541N03 - w/o - - 210 8

4 2
5/2 external pressure air operated
External pressure air return (bistable)
External pressure supply 2.5 to 10 bar 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 547N03 - w/o - - 240 9

4 2
5/3 W1 closed in center position - External pressure air operated
External pressure air return (bistable)
External pressure supply 2.5 to 10 bar 5 1 3
1/4 7 1250 2.5 10 10 50 NBR 542N03 - w/o - - 240 9

Dimensions Reference 7 Dimensions Reference 8 Dimensions Reference 9


40

40

40
32

32

32

23 24 23 23 24 23 23 24 23

86 86 86

13 44 13 13 22 22 13 13 22 22 13

3 1 5 3 5 3
22

22

22

G1/8 7.2 G1/8 7.2 G1/8 7.2


G1/4" (2x) M5 G1/4" (3x) M5 G1/4" (3x) M5

7 Catalogue 1101/UK - Ed. June 2010


G1/2" Series
Solenoid Operated Versions
N34 Series with 32 / 37 / 40 mm Coil
Admissible Max. admissible
differential fluid
Port size Orifice QN pressure temperature Seat Reference Consumption Weight Elect. Dim.
(bar) disc number Power (g) Group Ref.
(ºC)
(Watt)
max. Min. = 0ºC

G mm L/min min DC= AC~ Air & Valve Housing Coil DC AC


Neutral gases

3/2 Solenoid operated


Combined spring & air return (monostable) 3 1
1/2 12 3000 2.5 10 10 50 NBR 331N34 2995 481865 9 8 910 2 10
1/2 12 3000 2.5 10 10 50 NBR - 2995 495870 9 8 1130 2 -
1/2 12 3000 2.5 10 10 50 NBR - - 495905 8 8 1170 2 -

4 2

5/2 Solenoid operated


Combined spring & air return (monostable) 5 1 3
1/2 12 3000 2.5 10 10 50 NBR 341N34 2995 481865 9 8 900 2 11
1/2 12 3000 2.5 10 10 50 NBR - 2995 495870 9 8 1120 2 -
1/2 12 3000 2.5 10 10 50 NBR - - 495905 8 8 1160 2 -
4 2

5/2 Solenoid operated and return (bistable)


5 1 3
1/2 12 3000 2.5 10 10 50 NBR 347N34 2995 481865 9 8 1240 2 12
1/2 12 3000 2.5 10 10 50 NBR - 2995 495870 9 8 1680 2 -
1/2 12 3000 2.5 10 10 50 NBR - - 495905 8 8 1760 2 -

Dimensions Reference 10 Dimensions Reference 11 Dimensions Reference 12

Please consult the "How to Order" part at the end of each coil chapter.

8 Catalogue 1101/UK - Ed. June 2010


G1/2" Series
External Pressure Air Operated Series
5 xx N04 Series
Admissible Max. admissible
differential fluid
Port size Orifice QN pressure temperature Seat Reference Consumption Weight Dimensions
(bar) disc number Power (g) Reference
(ºC)
(Watt)
max. Min. = 0ºC

G mm L/min min DC= AC~ Air & Valve Housing Coil DC AC


Neutral gases

2
3/2 External pressure air operated
Combined spring & air return (monostable)
External pressure supply 2.5 to 10 bar 3 1
1/2 12 3000 2.5 10 10 50 NBR 531N04 - w/o - - 620 13

4 2
5/2 external pressure air operated
Combined spring & air return (monostable)
External pressure supply 2.5 to 10 bar 5 1 3
1/2 12 3000 2.5 10 10 50 NBR 541N04 - w/o - - 600 14

Dimensions Reference 13 Dimensions Reference 14

9 Catalogue
C
Cat
Cata logu
og e 1
1101/UK - Ed. June 2010
Coils and Spare Parts Informations
Safe Area & ATEX Zone 22

Coils 22 mm for N03-N05 Series


Safe Area & ATEX Zone 22 Ref. 496131 / 496482 / 496637

These coils with connection for 2 P+G DIN 43650 B plug are encapsulated in synthetic material,
conform to the IEC/CENELEC safety standards and comply with European low voltage directive
73/23/EC .

● Power: 3W 3 different types are available:


● Insulation Class: F (155°C) ● Ref. 496131
● Degree of Protection: IP65 for a safe area without plug
(with plug) ● Ref. 496482
● Duty Cycle: 100% ED for a safe area with plug
● Ambient Temperature: ● Ref. 496637
-10°C to 50°C for an ATEX area Zone 22

496637 coil series with connection 2P + G when mounted together with the supplied Pg9 plug
(delivered with the coil) are suitable for use in dangerous areas (dust Zone 22) according to
the European directive ATEX 94/9/C. Protection mode: Ex tD A22 IP65 - T95°C

Available Safe area Safe area ATEX


Voltages without DIN plug with DIN plug Zone 22 EX II 3D
Order Order Order
Code Code Code
12VDC 496131 C1 496482 C1 496637 C1
24VDC 496131 C2 496482 C2 496637 C2
48VDC 496131 C4 496482 C4 496637 C4
110VDC 496131 C5 496482 C5 496637 C5
24/50-60VAC 496131 P0 496482 P0 496637 P0
48/50-60VAC 496131 S4 496482 S4 496637 S4
110/50-60VAC 496131 P2 496482 P2 496637 P2
115/60VAC 496131 K8 496482 K8 496637 K8
230/50-60VAC 496131 P9 496482 P9 496637 P9

How to Order
The housing kit is already included into the coil reference, so it’s not needed to add it in the order code:
Valve Reference Number - Coil Reference - Voltage code = Order code
Example: 341N03 - 496131 C2
Valves and coils may be ordered also separately.

10 Catalogue 1101/UK - Ed. June 2010


Safe Area
Coils 32 mm / 37 mm / 40 mm for N33-N34-N35 Series
Safe Area Ref. 481865

N3x series are compatible with any Parker Lucifer coil part of electrical group 2. That group includes
many different coils for safe areas or areas submitted to ATEX certifications. These coils are of the
8/9W class.
These coils with connection for 2P+G DIN 43650 A plug are encapsulated in synthetic material,
conform to the IEC/CENELEC safety standards and comply with European low voltage directive
73/23/EC.

● Power: 8W (AC) 9W (DC)


● Insulation Class: F (155°C)
● Degree of Protection: IP65 (with plug)
● Duty Cycle: 100% ED
● Voltage Tolerance -10%/+10%
● Ambient Temperature -40°C/+50°C
◗ The application can be limited also
by the temperature range of the valve

Available Order
Voltages Code
12VDC 481865 C1
24VDC 481865 C2
48VDC 481865 C4
110VDC 481865 C5
24/50VAC 481865 A2
48/50VAC 481865 A4
110/50VAC 481865 A5
220-230/50VAC 481865 3D
380/50VAC 481865 A9
24/60VAC 481865 B2
115/60VAC 481865 K8
230/60VAC 481865 J3

How to Order
This coil must be used together with a housing kit which includes
d a nut,
t
a plate, and a washer. Housing Kit Order Code: 2995

Valve Reference Number - Housing Reference - Coil Reference - Voltage Code = Order Code
Example: 341N35 - 2995 - 481865 C2
Valves and coils may be ordered also separately.

11 Catalogue 1101/UK - Ed. June 2010


Coils and Spare Parts Informations
Safe Area

Coils 32 mm / 37 mm / 40 mm for N33-N34-N35 Series


Safe Area Coil 481000 Series with 4538 Watertight
and dust proof housing IP67 Ref. 481000

Coil 481000 series is encapsulated in synthetic material. Electrical connection is made with screw
terminals for wire up to 1.5 mm. This coil conforms to the IEC/CENELEC safety standards and
complies with European low voltage directive 73/23/EC. It must be used with a metallic housing.

● Power: 8W ● Voltage Tolerance -10%/+10%


● Insulation Class: F (155°C) ● Ambient Temperature -40°C/+50°C
● Degree of Protection: IP67 (with 4538 housing) ◗ The application can be limited also

● Duty Cycle: 100% by the temperature range of the valve

Available Order
Voltages Code
12VDC 481000 C1
24VDC 481000 C2
48VDC 481000 C4
110VDC 481000 C5
24/50VAC 481000 A2
48/50VAC 481000 A4
110-115/50VAC 481000 OA
220-230/50VAC 481000 3D
380/50-440/60VAC 481000 5P
24/60VAC 481000 B2
110-115/60VAC 481000 6J
220-240/60VAC 481000 4K
42/50-48/60VAC 481000 S7

Housing 4538
This enclosure is dust and water proof. It corresponds to the protection degree IP67 according to IEC/
EN60529. Corrosion resistant, the metallic housing offers good protection for the coil against shocks.
It can be 360° orientable. This housing must be equipped with 481000 series coil.
Material: galvanized passivated steel - Degree of protection IP67 according to IEC/EN 60529 - Electrical
connection: cable connection by cable gland according to DIN46320. Cable with outer diameter 6.5-13.5 mm
(M20x1.5) can be simply sealed using a rubber gland resilient sealing rings. The enclosure is internally and
externally fitted with grounding and earthing screw terminals.

How to Order
Valve Reference Number - Housing Reference - Coil Reference - Voltage Code = Order Code
Example: 331N34 - 4538 - 481000C2
Valves and coils may be ordered also separately.

12 Catalogue 1101/UK - Ed. June 2010


ATEX Zone 2-22
Coils 32 mm / 37 mm / 40 mm for N33-N34-N35 Series
ATEX Zone 2-22 Ref. 495870

This coil with connection 2P+G - when mounted together with the supplied Pg 9 plug (delivered
with the coil), is suitable for use in Gas and Dust dangerous areas (Zone 2-22), according to the
European directive ATEX 94/9/C.
Certificate LCIE 05 ATEX 6003 X - Protection mode: non sparking / limited energy solenoid

● II 3 G - Ex nAC IIC T3 / T4
0081 II 3 G-D
● II 3 D - Ex tD A22 IP65 - T 195°C / T 130°C

● Power: 8W (AC) 9W (DC)


● Insulation Class: F (155°C)
● Degree of Protection: IP65 (with plug)
● Duty Cycle: 100% ED
● Voltage Tolerance -10%/+10%
● Ambient temperature
◗ T3 (gaz) T 195°C (dust) -40°C/+65°C

◗ T4 (gaz) T 130°C (dust) -40°C/+50°C

◗ The application can be limited also


by the temperature range of the valve

Available Order
Voltages Code
24VDC 495870 C2
48VDC 495870 C4
110VDC 495870 C5
24/50VAC 495870 A2
48/50VAC 495870 A4
110/50VAC 495870 A5
220-230/50VAC 495870 3D

How to Order
This coil must be used together with a housing kit which includes a nut,
a plate, and a washer. Housing kit order code: 2995

Valve Reference Number - Coil Reference - Voltage code = Order code


Example: 331N34 - 2995 - 495870 A5
Valves and coils may be ordered also separately.

13 Catalogue 1101/UK - Ed. June 2010


ATEX zone 1-21

Coils 32 mm / 37 mm / 40 mm for N33-N34-N35 Series


ATEX Zone 1-21 Ref. 495905

This coil is suitable for use in Gas and Dust dangerous areas (Zone 1-21), according to the European
directive ATEX 94/9/C. It’s also IECEx certified according to the IECEx Scheme. Certificate LCIE
02 ATEX 6451 X - Protection modes: Explosionproof solenoids with flameproof enclosure /
encapsulation "d mb"
● II 2 G - Ex d mb IIC T4
0081 II 2 G/D
● II 2 D - Ex tD A21 IP67 - T 130°C

● Insulation Class H (180°C)


● Power: 8W (AC-DC)
● Degree of Protection IP67
● Duty Cycle 100%
● Voltage Tolerance -10%/+10%
● Ambient Temperature: -40°C/+65°C
◗ The application can be limited also
by the temperature range of the valve

Available Order
Voltages Code
24VDC 495905 C2
48VDC 495905 C4
110VDC 495905 C5
24/50VAC 495905 A2
48/50VAC 495905 A4
110/50VAC 495905 E5
220-230/50VAC 495905 3D
115/60 495905 E5
240/60 495905 B8

Electric connection is done in the connection


c io
ct on bo
box
ox
on an easily accessible connector terminals.
nal
als.
s.
M20x1.5 Cable gland

How to Order
The housing kit is already included into the coil reference, so it’s not needed to add it in the order code:
Valve Reference Number - Coil Reference - Voltage code = Order code
Example: 347N33 - 495905 C2
Valves and coils may be ordered also separately.

14
4 Catalogue 1101/UK - Ed. June 2010
ATEX Zone 1-21
Coils 32 mm / 37 mm / 40 mm for N33-N34-N35 Series
ATEX Solutions Zone 1-21 Ref. 483371 & 494040

These coils are suitable for use in Gas and Dust dangerous areas (Zone 1-21), according to the European
directive ATEX 94/9/C. Protection mode:encapsulated electrical parts with increased safety.

Reference 483371 or HZ06 494040 or HZ23


Approval LCIE 02 ATEX 6011 X LCIE 02 ATEX 6013 X
Type of Gas II 2 G - Ex e mb II T4 II 2 G - Ex e mb II T3 II 2 G - Ex e mb II T4
protection Dust II 2 D - Ex tD A21 T 130°C II 2 D - Ex tD A21 T 195°C II 2 D - Ex tD A21 T 130°C
Degree of protection IP67 IP67
Ambiant temperature -40°C to +65°C -40°C to +90°C -40°C to +65°C
The application is limited also by the temperature range of the valve
Class of insulation F (155°) H (180°)
Electrical connection By special cable gland or M20x1.5 "Ex e" on screw terminals for wires up to 1.5 mm².
Cables with outside diameter 6.5 mm to 13.5 mm can be simply sealed using the rubber gland
with resilient sealing rings supplied.
Elect. DC Pn (hot) 8W 8W
Power P (cold) 20°C 9W 9W
AC Pn (holding) 8W 8W
32 VA (9 W) 32 VA (9 W)
Voltage tolerance Tolerance -10/ +10% of the nominal voltage
Solenoid duty Continuous duty solenoid (ED 100%)

Available Order Order


Voltages Code Code
6VDC 483371 C0 -
12VDC 483371 C1 -
24VDC 483371 C2 494040 C2
36VDC 483371 C3 -
48VDC 483371 C4 -
60VDC 483371 M3 -
110VDC 483371 C5 -
125VDC 483371 3N 494040 3N
220VDC 483371 C7 494040 C7
12/50VAC 483371 A1 -
24/50VAC 483371 A2 494040 A2
48/50VAC 483371 A4 - Fuses: Both electrical 483371… and 494040… parts have to be connected in series with a
110-115/50VAC 483371 OA 494040 OA safety fuse according to CEI 60127-3.
220-230/50 483371 3D 494040 3D 483371… 494040…
24/60VAC 483371 B2 - DC: 24V / 400mA - 48V / 250mA DC: 24V / 400mA - 125V / 80mA
110-115/60VAC 483371 6J - 110V / 100mA 48V /220V - 63mA
220-240/60VAC 483371 4K - AC: 24V / 630mA - 48V / 315mA AC: 24V / 630mA - 48V / 315mA
110/115V / 160mA 110/115V / 160mA
380/50-440/60VAC - 494040 5P 220/230V / 80mA 220/230V / 80mA

How to Order
The housing kit is already included into the coil reference, so it’s not needed to add it in the order code:
Valve Reference Number - Coil Reference - Voltage code = Order code
Example: 347N33 - 483371C2
Valves and coils may be ordered also separately.

15 Catalogue 1101/UK - Ed. June 2010


Spare Parts Mounting Kit and Accessories

Kit for G1/4" Models


without conversion plate (N x 3 Series)
Kit includes the 2 mounting screws M5 x 25 A2, the dowel pin M5 x 10 A2,
the 2 O-rings NBR 15 x 2.5
Order code: 496132

Kit for G1/4" Models


with conversion plate (N x 5 Series)
Kit includes the 2 mounting screws
M5 x 35 A2, the dowel pin M5 x 20 A2,
the conversion plate equipped with its seals
Order code: 496742

Kit for G1/2" Models (N x 4 Series)


Kit includes the 2 mounting screws M6 x 35 A2, the dowel pin M6 x 12 A2,
the 2 O-rings NBR 24 x 3
Order code: 496133

Exhaust Flow Regulators


Material Body: Brass Filter element: Sintered bronze
Spring: Stainless Steel Seal: NBR

G1/8" Order code: 496551 G1/4" Order code: 496552 G1/2" Order code: 496553

16 Catalogue 1101/UK - Ed. June 2010


Connector for 22 mm Coil
Connector DIN43650 AB Pg9 2P+E
Order code: 481043

Housing for 22 mm Coil


Plastic nut with O-ring
Order code: 3125

Connector for 32 mm Coil


Connector DIN43650 AA Pg9 2P+E
Order code: 486586

17
7 Catalogue 1101/UK - Ed. June 2010
Notes

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further
investigation by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance,
endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry
standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or
authorized distributors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the
user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the
components or systems.

18 Catalogue 1101/UK - Ed. June 2010


Parker’s Motion & Control Technologies
At Parker, we’re guided
by a relentless drive to help
our customers become more
productive and achieve
higher levels of profitability
by engineering the best
systems for their require-
AEROSPACE CLIMATE CONTROL ELECTROMECHANICAL FILTRATION
ments. It means looking at
Key Markets Key Markets Key Markets Key Markets
customer applications from • Aircraft engines • Agriculture • Aerospace • Food & beverage
many angles to find new • Business & general aviation • Air conditioning • Factory automation • Industrial machinery
• Commercial transports • Food, beverage & dairy • Food & beverage • Life sciences
ways to create value. • Land-based weapons systems • Life sciences & medical • Life science & medical • Marine
Whatever the motion and • Military aircraft • Precision cooling • Machine tools • Mobile equipment
control technology need, • Missiles & launch vehicles • Processing • Packaging machinery • Oil & gas
• Regional transports • Transportation • Paper machinery • Power generation
Parker has the experience, • Unmanned aerial vehicles • Plastics machinery & converting • Process
breadth of product and global Key Products • Primary metals • Transportation
reach to consistently deliver. Key Products • CO2 controls • Semiconductor & electronics
• Flight control systems • Electronic controllers • Textile Key Products
No company knows more & components • Filter driers • Wire & cable • Analytical gas generators
about motion and control • Fluid conveyance systems • Hand shut-off valves • Compressed air & gas filters
technology than Parker. • Fluid metering delivery • Hose & fittings Key Products • Condition monitoring
& atomization devices • Pressure regulating valves • AC/DC drives & systems • Engine air, fuel & oil filtration
For further info call • Fuel systems & components • Refrigerant distributors • Electric actuators & systems
00800 27 27 5374. • Hydraulic systems & components • Safety relief valves • Controllers • Hydraulic, lubrication
• Inert nitrogen generating systems • Solenoid valves • Gantry robots & coolant filters
• Pneumatic systems & components • Thermostatic expansion valves • Gearheads • Process, chemical, water
• Wheels & brakes • Human machine interfaces & microfiltration filters
• Industrial PCs • Nitrogen, hydrogen & zero
• Inverters air generators
• Linear motors, slides and stages
• Precision stages
• Stepper motors
• Servo motors, drives & controls
• Structural extrusions

FLUID & GAS HANDLING HYDRAULICS PNEUMATICS PROCESS CONTROL SEALING & SHIELDING
Key Markets Key Markets Key Markets Key Markets Key Markets
• Aerospace • Aerospace • Aerospace • Chemical & refining • Aerospace
• Agriculture • Aerial lift • Conveyor & material handling • Food, beverage & dairy • Chemical processing
• Bulk chemical handling • Agriculture • Factory automation • Medical & dental • Consumer
• Construction machinery • Construction machinery • Food & beverage • Microelectronics • Energy, oil & gas
• Food & beverage • Forestry • Life science & medical • Oil & gas • Fluid power
• Fuel & gas delivery • Industrial machinery • Machine tools • Power generation • General industrial
• Industrial machinery • Mining • Packaging machinery • Information technology
• Mobile • Oil & gas • Transportation & automotive Key Products • Life sciences
• Oil & gas • Power generation & energy • Analytical sample conditioning • Military
• Transportation • Truck hydraulics Key Products products & systems • Semiconductor
• Welding • Air preparation • Fluoropolymer chemical delivery • Telecommunications
Key Products • Compact cylinders fittings, valves & pumps • Transportation
Key Products • Diagnostic equipment • Field bus valve systems • High purity gas delivery fittings,
• Brass fittings & valves • Hydraulic cylinders • Grippers valves & regulators Key Products
• Diagnostic equipment & accumulators • Guided cylinders • Instrumentation fittings, valves • Dynamic seals
• Fluid conveyance systems • Hydraulic motors & pumps • Manifolds & regulators • Elastomeric o-rings
• Industrial hose • Hydraulic systems • Miniature fluidics • Medium pressure fittings & valves • EMI shielding
• PTFE & PFA hose, tubing • Hydraulic valves & controls • Pneumatic accessories • Process control manifolds • Extruded & precision-cut,
& plastic fittings • Power take-offs • Pneumatic actuators & grippers fabricated elastomeric seals
• Rubber & thermoplastic hose • Rubber & thermoplastic hose • Pneumatic valves and controls • Homogeneous & inserted
& couplings & couplings • Rodless cylinders elastomeric shapes
• Tube fittings & adapters • Tube fittings & adapters • Rotary actuators • High temperature metal seals
• Quick disconnects • Quick disconnects • Tie rod cylinders • Metal & plastic retained
• Vacuum generators, cups & sensors composite seals
• Thermal management
Parker Worldwide

AE – UAE, Dubai FR – France, Contamine s/Arve RO – Romania, Bucharest


Tel: +971 4 8127100 Tel: +33 (0)4 50 25 80 25 Tel: +40 21 252 1382
parker.me@parker.com parker.france@parker.com parker.romania@parker.com
AR – Argentina, Buenos Aires GR – Greece, Athens RU – Russia, Moscow
Tel: +54 3327 44 4129 Tel: +30 210 933 6450 Tel: +7 495 645-2156
parker.greece@parker.com parker.russia@parker.com
AT – Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0 HK – Hong Kong SE – Sweden, Spånga
parker.austria@parker.com Tel: +852 2428 8008 Tel: +46 (0)8 59 79 50 00
parker.sweden@parker.com
AT – Eastern Europe, HU – Hungary, Budapest
Wiener Neustadt Tel: +36 1 220 4155 SG – Singapore
Tel: +43 (0)2622 23501 900 parker.hungary@parker.com Tel: +65 6887 6300
parker.easteurope@parker.com
IE – Ireland, Dublin SK – Slovakia, Banská Bystrica
AU – Australia, Castle Hill Tel: +353 (0)1 466 6370 Tel: +421 484 162 252
Tel: +61 (0)2-9634 7777 parker.ireland@parker.com parker.slovakia@parker.com
AZ – Azerbaijan, Baku IN – India, Mumbai SL – Slovenia, Novo Mesto
Tel: +994 50 2233 458 Tel: +91 22 6513 7081-85 Tel: +386 7 337 6650
parker.azerbaijan@parker.com parker.slovenia@parker.com
IT – Italy, Corsico (MI)
BE/LU – Belgium, Nivelles Tel: +39 02 45 19 21 TH – Thailand, Bangkok
Tel: +32 (0)67 280 900 parker.italy@parker.com Tel: +662 717 8140
parker.belgium@parker.com
JP – Japan, Tokyo TR – Turkey, Istanbul
BR – Brazil, Cachoeirinha RS Tel: +81 (0)3 6408 3901 Tel: +90 216 4997081
Tel: +55 51 3470 9144 parker.turkey@parker.com
KR – South Korea, Seoul
BY – Belarus, Minsk Tel: +82 2 559 0400 TW – Taiwan, Taipei
Tel: +375 17 209 9399 Tel: +886 2 2298 8987
KZ – Kazakhstan, Almaty
parker.belarus@parker.com
Tel: +7 7272 505 800 UA – Ukraine, Kiev
CA – Canada, Milton, Ontario parker.easteurope@parker.com Tel +380 44 494 2731
Tel: +1 905 693 3000 parker.ukraine@parker.com
LV – Latvia, Riga
CH – Switzerland, Etoy Tel: +371 6 745 2601 UK – United Kingdom,
Tel: +41 (0)21 821 87 00 parker.latvia@parker.com Warwick
parker.switzerland@parker.com Tel: +44 (0)1926 317 878
MX – Mexico, Apodaca
parker.uk@parker.com
CL – Chile, Santiago Tel: +52 81 8156 6000
Tel: +56 2 623 1216 US – USA, Cleveland
MY – Malaysia, Shah Alam
Tel: +1 216 896 3000
CN – China, Shanghai Tel: +60 3 7849 0800
Tel: +86 21 2899 5000 VE – Venezuela, Caracas
NL – The Netherlands,
Tel: +58 212 238 5422
CZ – Czech Republic, Klecany Oldenzaal
Tel: +420 284 083 111 Tel: +31 (0)541 585 000 ZA – South Africa,
parker.czechrepublic@parker.com parker.nl@parker.com Kempton Park
Tel: +27 (0)11 961 0700
DE – Germany, Kaarst NO – Norway, Ski
parker.southafrica@parker.com
Tel: +49 (0)2131 4016 0 Tel: +47 64 91 10 00
parker.germany@parker.com parker.norway@parker.com
DK – Denmark, Ballerup NZ – New Zealand, Mt Wellington
Ed. 2010-06-08

Tel: +45 43 56 04 00 Tel: +64 9 574 1744


parker.denmark@parker.com
PL – Poland, Warsaw
ES – Spain, Madrid Tel: +48 (0)22 573 24 00
Tel: +34 902 330 001 parker.poland@parker.com
parker.spain@parker.com
PT – Portugal, Leca da Palmeira
FI – Finland, Vantaa Tel: +351 22 999 7360 European Product Information Centre
Tel: +358 (0)20 753 2500 parker.portugal@parker.com Free phone: 00 800 27 27 5374
parker.finland@parker.com (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE,
IL, IS, IT, LU, MT, NL, NO, PT, SE, SK, UK)

© 2010 Parker Hannifin Corporation. Parker Hannifin Ltd. Catalogue 1101/UK - 06/2010 - TMCZ
All rights reserved.
Tachbrook Park Drive
Tachbrook Park, Warwick CV34 6TU
United Kingdom
Tel.: +44 (0) 1926 317 878
Fax: +44 (0) 1926 317 855
parker.uk@parker.com
www.parker.com/fcde Your local authorized Parker distributor

You might also like