Kaiweets Manual
Kaiweets Manual
True-RMS Digital
        Clamp Meter
□
□
Languages
                                     Video Instruction
Contents
Introduction····························································································3
    Safety Information··············································································3
Product Overview···················································································5
Function Buttons·····················································································7
Other Functions······················································································9
    AC voltage measurement with low-pass filter "LPF"································9
    High-Impedance Voltage Measurement • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 9
    Low impedance voltage measurement (LowZ) ····•••·····•••·····•••·····••••······10
Operating Instructions··············································································11
     Insert and replace batteries •· •· •• ••••••• •• •••••••••••••••••••••••••••••••••••••••• ••• ••• ••· ·11
     Turn on/off the meter··········································································11
     Automatic shutdown············································································11
     Auto-ranging·······················································································12
     AC Zero Input Behavior of True-rms Meters----·-·-·-·-·-·-·-·-·-·-·-·-·-·-·-·-·-·- - -12
     Connecting Test Leads                                                                                                                ·           ·            ·           12
Making             Measurements--------------------······-·······-·-·····-·-·····-·-···-·-·-···-·-·-···-·----13
     AC/ DC Current measurement - - - - - - - - - - - - - - - -• - - - - - - -• - - - - - - -• - - - - - - -• - - - - - - - • - - - - - - - •------13
     Voltage Measurement V (DC/ AC)--------------------------·-·-·-·-·-·-·-·-·-·-·-·-·-·-·- 15
     Frequency or Duty Cycle Measurements (Hz%) -----·-----------------·-·-·-·-·-- -16
     Resistance measurement Q                                                                                                                                                  17
     Continuity test - - - - - - - - - - - - - - - - - - - - - --- - •-·-- ·- • •-·-- ·- • •-·-- ·- • •--·- •- • •- ·- •- •- •- •- •- •-· - · - · - ·-···18
     Capacitance measurement - - - - - - - - - - - - - - - - - - - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -·----------19
     Diode Test ·-·-·                                                                                                                       ·            ·             ·       20
     Temperature measurement·-· -· -· -· -· -· -· - - -· - - - - -· -··· -· - -· -· - - - - -· -· - - - - -· -·· -· -·· ••·-·-----21
     Non-contact AC Voltage Detection (NCV)-------------------------------------------22
Specification - - - - - - - - - - - - - - - - - - -· -· -· -· -· -· -· -· -· -· -· -· -· -· -· -· - •· •· •· •· •· •· •· •· •· •· •-· •- -- -- •- -- -- -- •- -23
     Accuracy - - - - - - - - - - - - - - - - - - -· -· -·---------------------------------------------------------------24
Maintenance - - - - - - - - - - - - - - - - - - - - - - --- - - - - - --- - - - - - --- - - - - - --- - - --- - - - - - --- - - - - - --- - - - - - --- - - - - - - - -·-------25
     Cleaning the Meter·-· -· -·--· · - - - --- - - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -·--------------25
Three Year Warranty - - - - - - - - - - -• - - - - - - -• - - - - - - - - - - - - - - -• - - - - - - -· - - - - - - -· - - - - - - -· - - - - - - -·--------------26
                                                                                    2
Introduction
KAIWEETS HT206D is a digital True-RMS clamp meter with automatic range selection.
The Low Impedance (Low-Z) mode can detect and eliminate ghost or stray voltages.
Safety Information
                                            3
• Do not apply more than the rated voltage, as marked on the Meter, between the
terminals or between any terminal and earth ground.
• Remove test leads from the Meter before opening the Meter case.
• Never operate the Meter with the back cover removed or the case open.
• Never remove the back cover or open the case of an instrument without first removing
the test leads or the jaws from a live conductor.
• Use caution when working with voltages above 30 V ac RMS, 42 V ac peak, or 60 V
de. These voltages pose a shock hazard.
• Do not attempt to measure any voltage that might exceed the maximum range of the
Meter- 600 V RMS and 1 kHz or 600 V de.
• Do not operate the Meter around explosive gas, vapor, or dust.
• When using probes, keep fingers behind the finger guards.
• When making electrical connections, connect the common test lead before connecting
the live test lead; when disconnecting, disconnect the live test lead before disconnecting
the common test lead.
• Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, or diodes.
• Check the operation of the meter at a known source before and after use.
                                           4
Product Overview                            G)
CD NCV Probe
® Current Sensing Clamp
@ Flashlight
                                      @
• (I)
                                                     (
                                      ®
                                                           @@
@Data Hold Switch/ NCV Button                              ®
@ Rotary Function Switch
@ Current Clamp Opening Trigger
                                      (J)
(J) Function Buttons
                                                           ®
@ LED Display Screen
® COM Terminal
  (black test lead)                   ®
@) INPUT Terminal
  (red test lead)
                                  5
Symbol-Explanation
            Measurement Category II: For measuring electrical and electronic devices that are
 CAT. II    directly supplied with a mains voltage via a mains plug. This category also
            includes all lower categories (e.g. CAT I for measuring signal and control
            voltages).
            Measurement category Ill for testing and measuring circuits that are connected
 CAT. Ill
            to the distribution section of low-voltage power supply devices in buildings.
                                           6
Function Buttons
       This function allows the user to set the magnetization effects to zero
       when measuring DC. It must be performed after each high
       amplitude current measurement.
       With no conductor inserted into the clamp, press and hold the "Z /
       F" key (approx. 3 seconds) until a beep sounds and the ZERO
       symbol appears on the display.
       Press the "Z / F" key to switch the respective secondary function
       between the different measurements for the applications accessible
       via the function switch such as between AC and DC.
                                   7
Press the "MAX/ MIN" button to display the minimum or maximum
values one after the other. Press and hold the button for more than
2 seconds to exit MAX/ MIN mode.
Work light: Press and hold this button for more than 2 seconds to
switch the work light on or off.
                            8
Other Functions
AC voltage measurement with low-pass filter "LPF"
The"LPF" function allows the clamp meter to filter interfering signals of over 60
Hz. These signals can lead to inaccurate measurements. The meter filters
these signals and only measures the voltage signal.
The LowZ voltage measurement must not exceed 600 V. Due to the reduced
impedance, this measurement function is not suitable for continuous
measurement. The measurement duration of 1 minute must be observed.
                                        10
Operating Instructions                                                        .,1
Automatic shutdown
No operation in 15 minutes, the clamp meter beeps 3 times. Without further
operation, the clamp meter beeps again and switches off automatically.
Press any key to restore the clamp meter to operating status. The symbol
appears on the display.
To deactivate the automatic switch-off, hold down the "Z / F" key for more than 2
                                        11
seconds and switch on the clamp meter at the same time. The symbol
disappears. Restart after switching off the meter, the automatic switch-off can be
restored.
Auto-ranging
The meter automatically selects the measuring range that is best suited for the
measurement performed. The measuring unit and resolution are adjusted at the
same time.
AC Zero Input Behavior of True-rms Meters
Unlike averaging meters, which can accurately measure only pure sinewaves,
True-rms meters accurately measure distorted waveforms. Calculating True-
rms converters require a certain level of input voltage to make a measurement.
This is why ac voltage and current ranges are specified from 5 % of range to
100 % of range. Non-zero digits that are displayed on a True-rms meter when
the test leads are open or are shorted are normal. They do not affect the
specified ac accuracy above 5 % of range.
Connecting Test Leads
Do not test if leads are improperly seated. Results                    INCORRECT
1. Turn the rotary switch to the correct current setting (60A / 600A). "DC"
appears on the display. Press the "Z / F" button, AC is shown on the display.
2. Press the clamp release lever and open the clamp.
3. Grasp the individual current conductor to be measured and close the current
clamp again. Position the conductor in the middle between the two triangular
position symbols on the pliers.
   ► Do not use the current clamp to surround more than one conductor.
  ► If the supply and return conductors (e.g. Land N) are measured, the currents
    will cancel each other out and no measurement will be displayed. The cables of
    household appliances usually contain L and N conductors. A cable separator is
    required to measure with the current clamp.
                                         13
  ► If several supply conductors (e.g. L1 and L2) are measured, the currents add up.
  ► Center the conductor through the current clamp (above the markings)
  ► Hold your fingers behind the tactile barrier.
( (
4. The measured current is shown on the display. If current> 3A, the orange
display lights up.
5. During AC current measurement, press "Z / F" to display the frequency value
or use the LPF function measurement.
                                         14
Voltage Measurement V (DC / AC}
&Voltage above 600 V cannot be measured! When measuring high voltage, pay special
attention to safety to avoid electric shock or injury.
1. Set the rotary switch to v.Press the "Z / F" key to change the AC or DC voltage
measurement.
2. Plug the black test lead into the COM socket and the red test lead into the INPUT
socket.
3. Then bring the test probes into contact with the points to be measured.
4. Read the result on the display. If the voltage is> 80 V, the orange display lights up.
5. When measuring the AC voltage, press "Z / F" to display the frequency result or the
result of the LPF function.
6. If you are measuring low impedance, turn the rotary switch to the Low-Z position and
press the "Z / F" button to switch between AC and DC voltage.
&Attention
High impedance voltage measurement: 10 MO
Low impedance voltage measurement: 300 kO
                                           15
Frequency or Duty Cycle Measurements (Hz%)
Lt. Do not enter a voltage above 10 V!
When measuring high voltage, pay special attention to safety to avoid electric
shock or injury.
1. Turn the rotary function switch to Hz% and press the "Z / F" key to switch over
the frequency or duty cycle measurement.
2. Plug the black test lead into the COM socket and the
red test lead into the INPUT socket.
3. Connect the probes to the measuring points (connect
to the measured power supply or to the parallel
connection).
4. Read the result on the display.
                                         16
Resistance measurement                 n
& Do not enter a voltage above 10 V! Make sure that the power supply to the
circuit is disconnected and all capacitors are discharged.
                                       17
Continuity test•>>)
Lt:. Do not enter a voltage above 10 V! Make sure that the power supply to the
circuit is disconnected and all capacitors are discharged.
1. Turn the rotary switch to t and press the "Z / F" key several times until
appears on the display. The continuity test is now active.
2. Plug the red test lead into the INPUT socket ..
and the black test lead into the COM socket.
3. Connect the probes to the circuit or
component under test.
4. If the resistance is <30 0, an acoustic
signal sounds continuously and the orange            r
backlight lights up.
                                        18
Capacitance measurement
1. Remove power from the circuit being tested. Turn the rotary function switch
to 1t , press the "Z/F" key to cycle through from resistance to continuity to
capacitance function.
2. Connect the black test lead to the COM terminal and the red test lead to the
"INPUT" terminal.
3. Connect the probes across the circuit or (capacitance) component to be tested.
4. View the reading on the display.
&Warning
To avoid electrical shock when testing capacitance in a circuit, make sure the
power to the circuit is turned off and all capacitors are discharged.
To avoid damaging the instrument or equipment, do not input a voltage greater
than 10V.
Note:
When measuring capacitance greater than 100uF, it will take a long to measure
correctly.
                                       19
Diode Test
1. Turn the rotary function switch to    . Press the "Z/F" key to cycle through from
resistance (to continuity to capacitance) to diode function. Remove power from the circuit
being tested.
2. Connect the black test lead to the COM terminal and the red test lead to the
INPUT terminal.
3. Connect the black test lead to the cathode side and the red test lead to the anode side
of the diode being tested.
4. Read forward bias voltage value on the LCD.
5. If the polarity of the test leads is the reverse of the
diode polarity, the LCD reading shows "OL". This
can be used for distinguishing the anode side and
cathode side of a diode.
.&.Warning
To avoid electrical shock when testing diodes in a circuit, make sure the power
to the circuit is turned off and all capacitors are discharged.
To avoid damaging the instrument or equipment, do not input a voltage above 10V.
                                            20
Temperature measurement
1. Turn the rotary function switch to °C/r position. Press "Z/F" to select °C or °F,
the display reflects the chosen temperature unit.
2. Insert the K-type thermocouple into the meter, the positive pole (red) of the therm
ocouple into the "INPUT" input, and the negative pole (black) into the "COM" input.
3. Contact the thermocouple probe with the measurement object, then the reading
appears on the display.
4. Connect the temperature probe with the testing point.
&Warning
To avoid possible electric shock DO NOT apply the
probe tip to any conductor that is greater than 30 V
ac, 42 V peak or 60 V de to earth.
Note: It takes a long time for the cold end of thermocouple to be restored in the
instrument to achieve thermal balance with the environment.
                                         21
Non-contact AC Voltage Detection (NCV)
& Make sure that all measuring sockets are free. Remove all test leads and
adapters from the meter. This function only serves as an aid.
1. Turning the rotary dial to any position, hold down the "H/NCV" for more than
2 seconds, "click" a sound, the meter shows the "NCV" character and then
enter the NCV detection function.
2. Then the NCV probe will be approached the detected point gradually.
3. When the signal of weak electromagnetic field is sensed, the character "- -
L'' is displayed and there appears slow beeping sound.
4. When the signal of strong electromagnetic field is sensed, the character"- -
H" is displayed and there appears a fast beeping sound.
5. Press more than 2 seconds or turn the rotary function to exit NCV detection
function.
                                      22
Specification
Display........................................................................6000 counters, True RMS
Display update frequency.................................................................approx. 3 Hz
Measuring impedance................................................................10 MO (V range)
Operating voltage.........................................................................2 x AAA (1.5V)
Weight:...........................................................................................approx. 260g
Dimension:.........................................................................193mm x 73mm x 34mm
Security standard: ...........................................EN61010-1, 2-030 EN61010-2-033
                                                             EN61326-1 CATIII 600V
Operating temperature........................................................................ O to +40 °C
Operating humidity........................................................................<80% (> 30q
Operating height.......................................................................0 to max. 2000 m
Storage temperature ............................................................................- 10 to +60 'C
Air humidity in storage.................................................................................<70%
                                                     23
Accuracy
                  Range        600mV       6V         60V        600V
DC Volts                                                                                                     ±(0.5%+5)
                 Resolution    0.1mV 0.001V         0.01V         0.1V
                  Range            6V   60V         600V
AC-Volts                                                                                                     ±(0.8%+5)
                 Resolution    0.001V 0.01V          0.1V
                  Range          60A    600A
DC-Amps                                                                                                      ±(2.5%+5)
                 Resolution     0.01A     0.1A
                  Range          60A    600A                                                                ±(2.5%+5) at
AC-Amps                                                                                                     40-400Hz;
                 Resolution     0.01A     0.1A                                                              other ±(3%+10)
                  Range         6000    6kO    60kO         600kO         6MO      60MO
Resistance                                                                                                   ±(1.0%+5)
                 Resolution      0.10 0001k0 0.01kO             0.1kO 0.001MO    0.01MO
                  Range          10nF 100nF 1000nF               10µF    100µF   1000µF     10mF    100mF
Capacitance                                                                                                  ±(4.0%+5)
                 Resolution    0.001nF 0.01nF  0.1nF   0.001µF 0.01µF   0.1µF 0.001mF 0.01mF
                  Range           10Hz 100Hz 1000Hz     10kHz 100kHz 1000kHz
                                                                                                             ±(1.0%+3)
                 Resolution   0.001Hz 0.01Hz   0.1Hz 0.001kHz 0.01kHz  0.1kHz
Frequency         Range         10MHz
                                                                                                             ±(3.0%+3)
                 Resolution   0.001MHz
                  Range        1%-99%
Duty Cycle       Resolution                                                                                  ±(3.0%+3)
                                0.1%
                                                                24
Maintenance
Lt. Warning
• To avoid electrical shock, disconnect test leads from the meter before
removing its back cover. Never use the Meter with the back cover removed.
• Repairs or servicing not covered in this manual should be performed only by
qualified personnel.
Lt. Caution
• To avoid contamination or static damage, do not touch the circuit board
without proper static protection.
• If the Meter is not going to be used for a long time, remove the battery. Do not
store the Meter in a high temperature or a high humidity environment.
                                        25
Three Year Warranty
KAIWEETS will repair, without charge, any defects due to faulty materials or
workmanship for three years from the date of purchase provided that:
• Proof of purchase is produced.
• Service/repairs have not been attempted by unauthorized persons;
• The product has been subject to fair wear and tear;
• The product has not been misused;
Defective products will be repaired or replaced, free of charge or at our
discretion, if sent together with proof of purchase to our authorized
distributor(s). For further detail of warranty coverage and warranty repair
information, send email to support@Kaiweets.com.