DIGITAL CLAMP METER
21-S
Safety Statement                          1
Safety Symbols                            4
Overview                                  5
     Instrument panel description         5
     Function button:                     6
Measurement Operation                     6
     Power on/off                         7
     Maximum/minimum value measurement    7
     Flashlight on/off                    8
     Data hold                            8
     Auto Power off                       8
     Cancel Auto Power off                8
     SMART measurement mode               9
Professional measurement mode            10
     AC/DC current measurement           10
     AC inrush current measurement       11
     AC/DC voltage measurement           12
     Resistance measurement              13
     Continuity test                     13
     Diode test                          14
     AC/DC mV measurement                15
     Frequency/duty measurement                16
     Capacitance measurement                   16
     Temperature measurement                   17
     Non-contact AC Voltage Detection (NCV)    18
     Single probe live wire detection (LIVE)   19
General Technical Specifications               20
Accuracy Specifications                        21
     DC voltage                                21
     AC voltage                                22
     DC current                                22
     AC current                                22
     Resistance                                23
     Continuity                                23
     Diode                                     24
     Capacitance                               24
     Frequency/Duty                            25
     Temperature                               26
Maintenance                                    26
     General maintenance                       27
     Battery Installation or Replacement       27
          SAFETY STATEMENT
    Warning
Read this manual before using the instrument.
“ Warning” mark indicates the condition and operation
which may cause danger to users.
“ Caution” mark refers to the condition and operation
which may cause damage to the instrument or
equipment.
    Warning
In order to avoid possible electric shock or personal
injury and other safety accidents, please abide by the
following specifications:
•     Please read this manual carefully before using the
      instrument, and pay special attention to safety
      warning information.
•     Strictly observe the operation of this manual and
      use this instrument. Otherwise, the protection
      function of the instrument may be damaged or
      weakened.
•     Please be careful if the measurement exceeds 30V
      AC true RMS, 42V AC peak or 60V DC. There may
      be danger of electric shock at this kind of voltage.
•     Voltage applied between terminals or between
                           1
    each terminal and grounding point shall not
    exceed the rated value.
•   By measuring the known voltage to check whether
    the meter work is normal, if it is not normal or
    damaged, do not use it again.
•   Before using the instrument, please check whether
    there are cracks in the instrument shell or plastic
    parts damaged. If so, please do not use again.
•   Before using the instrument, please check whether
    the probe is cracked or damaged. If so, please
    replace the same type and the same electrical
    specifications.
•   Do not exceed the lowest rated Category of
    Measurement (CAT) rating in products, probes or
    accessories.
•   Do not measure the current when the probe is
    inserted into the input jack.
•   Don't work alone.
•   Please comply with local and national safety code.
    Wear personal protection equipment (such as
    approved rubber gloves, masks and flame
    retardant clothes, etc.) to prevent being damaged
    by electric shock and electric arc due to exposed
    hazardous live conductor.
•   When it shows low battery indicator, please
                         2
    replace the battery in time in case of any
    measurement error.
•   Do not use the instrument around explosive gas,
    steam or in wet environment.
•   When using the probe, please put your fingers
    behind the finger protector of the probe.
•   When measuring, please connect the neutral wire
    or the ground wire firstly, then connect the live
    wire; When disconnecting, please disconnect the
    live wire firstly, then disconnect the neutral wire
    and ground wire.
•   Before opening the outer cabinet or battery cover,
    please remove the probe on the instrument. Do
    not use the instrument in the circumstances that
    the instrument is taken apart or battery cover is
    opened.
•   It only meets the safety standards when the
    instrument is used together with the supplied
    probe. If the probe is damaged and needs to
    replace, the probe with same model number and
    same electrical specifications must be used for
    replacement.
                         3
High voltage warning
AC (Alternating current)
DC (Direct current)
AC or DC
Warning, important safety signs
Ground
Equipment with double insulation /
reinforced insulation protection
Low battery
Product complies with all relevant
European laws
Inrush current measurement
The additional product label shows that
do not discard this electrical/electronic
product into household garbage.
              4
Overview
A new generation of true RMS high performance
intelligent digital clamp meters that combine a wide
range of functions to make your work easier, more
efficient and safer.
It is capable of measuring AC/DC voltage, AC/DC current,
inrush current, frequency, duty cycle, resistance,
capacitance, temperature, diode, continuity, NCV and
more.
Instrument panel description
1     CV probe
2     Clamp
3     Flashlight
4     Alarm Indicator LED
5     Trigger
6     Display screen
7     Function button
8     Black meter pen socket
9     Red meter pen socket
10    Power button
11    Data hold/Flashlight key
                            5
Function button:
     Gear function selection/intelligent measurement
     button
     Maximum/Minimum Value button
     Function selection/inrush current measurement
     button
Measurement Operation
     Warning
•    Do not measure voltages above 600V as this may
     damage the meter.
•    When measuring high voltage, pay special attention
     to safety, so as not to be subjected to electric shock
     or personal injury.
•    Before use, test known voltages or currents with the
     meter to confirm that the meter is fully functional.
Power on/off
1)   Press and hold the       key for about 2 seconds to
     turn on.
2)   The meter automatically performs a self-test when
     switched on and displays "CAL", do not press the
     trigger to open the clamp at this time.
3)   Until the buzzer beeps "beep, beep, beep" to
     indicate the completion of the self-test.
                            6
4)   The meter is only available for measurement.
5)   When the measurement is finished, press and hold
     the    key for about 2 seconds to switch off the
     meter.
Maximum/minimum value measurement
1)   Press    button to switch on the maximum and
     minimum value measurement.
2)   Press       button again to cycle through the
     maximum and minimum values.
3)   Press the    button and hold it for more than 2
     seconds to exit the maximum and minimum
     measurement.
Note: This function does not work with inrush current,
continuity, diode, frequency/duty cycle, temperature,
NCV/Live functions.
Flashlight on/off
      Press the button and hold for more than 2 seconds
to turn the flashlight on or off.
Data hold
     Press the      button to enable or disable the data
     hold function.
Auto Power off
                           7
     If there is no operation within 15 minutes after
     starting up, the meter will automatically shut down
     to save battery energy.
Cancel Auto Power off
1)   Press and hold the     key, then press the key to turn
     on the instrument power and then release           the
     key, the display will have no " " symbol and the
     automatic switch-off function will be cancelled.
2)   Restart the machine to restore the automatic
     shutdown function. The display displays the " "
     symbol.
Note: After the automatic shutdown function is disabled,
you need to manually power off the meter.
SMART measurement mode
The meter enters smart mode by default. Can measure AC
and DC voltage, AC and DC current, resistance,
continuity, the instrument automatically identify the
measurement signal.
1)   Press the    button to turn on the power supply of
     the meter. After the self-test is completed, the meter
     will display        and enter the intelligent
     measurement mode.
2)   Don't need to select the measurement function,
     directly measure the AC/DC voltage, AC/DC current,
                            8
     resistance, continuity, the instrument automatically
     identify and measure. The current is measured with
     the clamp, and the other measurements are taken
     from the pen input.
3)   Read the measurement results from the display
     screen. The frequency is displayed when the AC
     signal is measured.
Note1    : Minimum identifiable DC current 0.8A.
         : Minimum identifiable AC current 0.5A.
         : Minimum identifiable AC/DC voltage 0.8V.
Note2    Automatic identification priority: resistance, DC
         voltage, AC voltage, DC current, AC current.
Professional measurement mode
AC/DC current measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press   button, set the pointer to "A", and press
   the    button to select AC or DC current
   measurement function.
3) In the DC current measurement function, if the
   display is not zero when the instrument is not
                            9
    measuring, press and hold the "     " key to clear zero,
    display "ZERO" and then measure.
4) Then press the trigger to open the clamp, clamp the
   conductor to be tested, slowly release the trigger until
   the clamp are completely closed, and determine
   whether the conductor to be tested is clamped in the
   center of the pliers, if the conductor is not in the
   center of the pliers, additional errors will occur.
5) Read the measurement results from the display
   screen. The frequency is also shown on the display
   when measuring AC current.
Note: AC clamp meter without DC current measurement
function; AC/DC clamp meter with this function
AC inrush current measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press      button, set the pointer to "A", and press the
         button to select inrush current measurement
    function and display the symbol "INRUSH".
3) Then press the trigger to open the clamp, clamp the
   conductor to be tested, slowly release the trigger until
   the clamp are completely closed, and determine
                            10
   whether the conductor to be tested is clamped in the
   center of the pliers, if the conductor is not in the
   center of the pliers, additional errors will occur.
4) Turn on the device to be tested (such as the motor)
   and then trigger the measurement by the surge
   current.
5) Read the measurement results from the display
   screen.
Note: The measuring range of inrush current is 5~600A.
AC/DC voltage measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press     button, set the pointer to "V", and press the
       button to select AC or DC voltage measurement
   function.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Contact the probe to the measured circuit (connect to
   the measured power supply or circuit in parallel).
5) Read the measurement result on the screen. When
   the AC voltage is measured, the frequency is
   displayed on the display screen.
                           11
Resistance measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press      button, set the pointer to the "Ω" position.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Contact the probe to the measured circuit or
   resistance.
5) Read the measurement result on the screen.
Continuity test
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press    button, set the pointer to the "    " position.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Contact the probe to the measured circuit or
   resistance.
5) If the resistance or circuit of the measured resistance
   is less than 50Ω, the buzzer sounds and the alarm
                            12
    indicator light is green, the screen displays the
    resistance.
Diode test
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press button, set the pointer to the "      " position.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Touch the diode anode with the red probe, the black
   probe contacts the diode cathode.
5) Read the measurement result on the screen.
6) If the probe polarity is opposite to the diode polarity,
   the meter shows "OL", which can be used to
   distinguish the anode and cathode.
AC/DC mV measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display and enter the intelligent measurement
   mode.
2) Press    button, set the pointer to "mV", and press
   the button to select AC or DC voltage measurement
                            13
   function.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Connect the meter in parallel to the power supply or
   load to be tested.
5) Read the measurement result on the screen. When
   the AC voltage is measured, the frequency is
   displayed on the display screen.
Frequency/duty measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press        button, set the pointer to the "Hz/%"
   position.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Connect the meter in parallel to the power supply or
   load to be tested.
5) Read the measurement result on the screen.
Capacitance measurement
1) Press the     button to turn on the power supply of
                           14
    the meter. After the self-test is completed, the meter
    will display               and enter the intelligent
    measurement mode.
2) Press    button, set the pointer to the "    " position.
3) Insert the red probe in “INPUT” jack, insert the black
   probe in “COM” jack.
4) Contact the probe to the measured circuit or
   Capacitance.
5) Read the measurement results from the display
   screen after the display is stable.
Note: The stability time of large capacitance is relatively
long
Temperature measurement
1) Press the     button to turn on the power supply of
   the meter. After the self-test is completed, the meter
   will display               and enter the intelligent
   measurement mode.
2) Press     button, set the pointer to the "   " position.
3) Insert the K-type thermocouple into the instrument,
   the positive pole (red) of the thermocouple into the
   “INPUT” jack, and the negative pole (black) into the
   “COM” input.
4) Contact the thermocouple probe with the measured
   object and read the results from the display screen.
                            15
     Warning
When measuring temperature with thermocouple, the
probe of thermocouple can't touch the charged object,
otherwise it may damage the instrument and may suffer
electric shock or personal injury.
     Note :
It takes a long time for the cold end of thermocouple to
be restored in the instrument to achieve thermal balance
with the environment.
Non-contact AC Voltage Detection (NCV)
1)   Press the   button to turn on the power supply of
     the meter. After the self-test is completed, the
     meter will display      and enter the intelligent
     measurement mode.
2)   Press     button, set the pointer to the "NCV/Live"
     position.
3)   Then NCV probe gradually approaches the detected
     point.
4)   When the weak electric field signal is induced, the "-
     -L" symbol will be displayed, the beep will emit a
     slow beep sound, and the green LED indicator will
     light up.
5)   When the strong electric field signal is induced, the
                            16
      "--H" symbol will be displayed, the beep will emit
      a fast beep sound, and the red LED indicator will
      light up.
Note: Before using the NCV function, remove the
stylus. Otherwise, the detection accuracy will be
affected.
Single probe live wire detection (LIVE)
1) Press the    button to turn on the power supply of
   the meter. After the self-test is completed, the
   meter will display        and enter the intelligent
   measurement mode.
2) Press      button, set the pointer to "NCV/Live"
   position, and press the    button to select "Live"
   measurement function.
3) Insert the red probe into the "INPUT" jack and
   remove the black probe.
4) Contact the red probe with the conductor under
   test
5) When a low voltage is detected the character "---L"
   is displayed, the beeper emits a slow beeping tone
   and the green LED lights up.
6) When a high voltage is detected, the "--H" character
   is displayed, the buzzer emits a fast beeping sound,
   and the red LED indicator lights up. Under normal
   circumstances, the detected line is "LIVE" line at this
                           17
    time.
General Technical Specifications
•   Environment condition of using:
       CAT.III 600V
       Pollution level ±2
       Altitude < 2000m
       Working environment temperature and
       humidity: 0~40°C (<80% RH, <10°C non-
       condensing).
       Storage environment temperature and
       humidity: -10~60°C (<70% RH, remove the
       battery).
•   Temperature coefficient:
    0.1x accuracy/°C (<18°C or >28°C).
•   MAX. Voltage between terminals and earth
    ground:600V
•   Display: 6000 counter readout. Automatically
    display the unit symbols according to the shift of
    the measurement function.
•   Over range indication: it displays “OL”.
•   Low battery indication: when the battery voltage is
    lower than the normal working voltage, “      ” will
    be displayed.
                             18
•    Input polarity indication: automatically display
     “__”.
•    Power: 3 x 1.5V AAA batteries.
Accuracy Specifications
The accuracy applies within one year after the
calibration.
Reference condition: the environment temperature
18°C to 28°C, the relative humidity is no more than 80%
accuracy: ±( reading + word)
DC voltage
     Range          Resolution           Accuracy
600mV              0.1mV
6V                 0.001V
                                      ± (0.5%reading+5)
60V                0.01V
600V               0.1V
Input impedance : 10MΩ. Maximum input voltage: 600V
                             19
AC voltage
      Range         Resolution             Accuracy
 600mV             0.1mV
 6V                0.001V
                                     ± (0.8%reading+5)
 60V               0.01V
 600V              0.1V
Input impedance : 10MÙ Maximum input voltage: 600V.
Frequency Response : 40Hz ~ 1kHz(TRMS).
DC current
      Range         Resolution             Accuracy
 60A               0.01A
                                     ± (2.5% reading +5)
 600A              0.1A
Maximum input current: 600A.
AC clamp meter without DC current function.
AC current
  Range     Resolution               Accuracy
                           50~60Hz : ± (2.5%reading + 5)
 60A           0.01A       Other : ± (3.0%reading + 10)
                           Inrush current :
 600A          0.1A        ± (5.0%reading+10)
Maximum input current: 600A.
Frequency Response : 40Hz ~ 400Hz(TRMS).
                             20
Resistance
 Range Resolution                 Accuracy
600Ω       0.1Ω
6kΩ        0.001kΩ
60kΩ       0.01kΩ
                               ± (1% reading +5)
600kΩ      0.1kΩ
6MΩ        0.001MΩ
60MΩ       0.01MΩ
Continuity
        <50Ù, the buzzer         Test Voltage Approx.
        sounds and the green     1V Overload protection :
        indicator LED on.        250V
Diode
        It displays the          Reverse DC voltage is
        approximate forward      about 3V
        voltage value of the     Overload protection:
        diode.                   250V
                         21
Capacitance
  Range Resolution               Accuracy
6nF        0.001nF
60nF       0.01nF
600nF      0.1nF
6µF        0.001µF
                            ± (4.0% reading +5)
60µF       0.01µF
600µF      0.1µF
6mF        0.001mF
60mF       0.01mF
Overload protection: 250V.
The above accuracy does not include the error caused
by the pen capacitance.
Frequency/Duty
  Range Resolution               Accuracy
100Hz      0.01Hz
1000Hz     0.1Hz
10kHz      0.001kHz         ±(1.0%reading+3)
100kHz     0.01kHz
1000kHz    0.1kHz
10MHz      0.001MHz
                            ±(3.0%reading+3)
1~99%      0.1%
                          22
Overload protection: 250V.
The "mV" gear voltage measurement frequency :
1) Range: 10Hz ~ 2 kHz
2) Sensitivity of signal: >50mV(RMS), sine wave
The "V" gear voltage measurement frequency :
1) Range: 10Hz ~ 2 kHz
2) Sensitivity of signal: >0.5V(RMS), sine wave
The current measurement frequency :
1) Range:10Hz ~ 2 kHz
2) Sensitivity of signal: >12A(RMS), sine wave
The "Hz/%" gear :
1)     Frequency range: 5Hz ~ 10MHz
2)     Voltage range: >2.5V RMS (The higher the
       frequency, the higher the voltage)
Temperature
     Unit   Resolution            Accuracy
                         -40ºC~ 10ºC       ± 3℃
      ºC        1ºC      10ºC ~ 100ºC      ± 2℃
                         100ºC ~ 1000ºC    ± 2.0%
                         -40ºF~50ºF        ± 6℉
                         50ºF~ 212ºF       ± 4℉
      ºF        1ºF      212ºF~ 1832ºF     ± 2.0%
Note: The above accuracy does not include the error of
thermocouple probe.
                           23
Maintenance
     Warning
To avoid electric shock, remove the test probe
before opening the battery cover or back cover
General maintenance
•    Maintenance and service of this instrument must
     be carried out by professional qualified
     maintenance personnel or maintenance
     department.
•    Use wet cloth or mild detergent regularly to clean
     the shell. Do not use abrasives or solvents. Wipe
     the contacts in the socket with a clean cotton
     swab soaked in alcohol.
Battery Installation or Replacement
The meter uses three AAA 1.5V batteries. Please install
or replace the batteries according to the following
steps.
1)   Turn off the power of the instrument and remove
     the probe
2)   Use screwdriver to unscrew the screw that fixes the
     battery cover and remove the battery cover.
                           24
3)   Remove the old battery and install the new battery
     according to the polarity of the battery marked in
     the battery box.
4)   After installing the new battery, cover the battery
     cover and lock the screw.
     Warning
•    To avoid the possibility of electric shock or personal
     injury caused by incorrect reading, replace the
     battery immediately when the " " sign is displayed
     on the display screen.
•    Please use the same type of batteries, do not use
     substandard batteries.
•    In order to ensure safe operation and maintenance
     of the instrument, please take out the battery when
     not in use for a long time, in order to prevent
     damage to the product caused by battery leakage.
                            25