PULS does it again:
practical, versatile and reliable like
the SilverLine – yet small like
no other.
Data Sheet
MiniLine ML50.102
with DC 12-15V / 50W
• Mounted and connected • Adjustable output voltage:
in record time, no tools required DC 12-15V(without jumper) resp.
• World-wide approvals (UL, EN, CSA, DC 15V (with jumper)
CB Scheme) for industry and office/home • 100-240V Wide Range Input
• Tiny: WxHxD = 45 x 75 x 91mm • NEC Class 2 Power Supply and
Hazardous Location Class I Div. 2
(UL 1604)
PULS GmbH, Elektrastraße 6, 81925 Munich
Tel. +49.(0)89.9278-244, Fax: +49.(0)89.9278-299
sales@puls-power.com, http://www.puls-power.com Mini is more.
ML50e102/200917
s
Cl amp
Technical Data ML50.102 ng
Spri
X Input X Output
Input voltage AC 100-240V (Wide Range), 47...63Hz Output voltage without jumper: DC 12-15V (adj. by front panel
Admiss. limits: AC 85...264V (DC 85...375V) potentiometer, adj. range guaranteed);
Input current <1.0A (@ AC 100V, 50W Pout) • preset with jumper: 15V ± 3.5%,
<0.6A (@ AC 196V, 50W Pout) without jumper: 12V ± 0.5%
External fusing not required, unit provides internal fuse Voltage regulation stat. <1% @ Vout = 12V
(T3A15H, not accessible) stat. < 1.5% @ Vout = 15V,
dyn. ±3% Vout over all
Transient immunity Transient resistance acc. to VDE 0160 / W2
(750V / 1.3ms), over entire load range Ripple/Noise <100mVPP (20MHz bandw., 50 Ω measurem.)
Hold-up time >170ms @ AC 230V, 12V / 4.2A Overvoltage prot. (OVP) <22V
(see diagram below) >97ms @ AC 196V, 12V / 4.2A Rated continuous at convection cooling:
>17ms @ AC 100V, 12V / 4.2A loading max. Iout = 4.2A @ Vout = 12V,
max. Iout = 3.4A @ Vout = 15V,
X Efficiency, Reliability details see derating diagram below
Efficiency typ. 90% (AC 230V, 12V / 4.2A) • power reserve max. 10%(depending on Vin);
(see also diagram below) details see diagr. 'output characteristic' below
Losses typ. 6W (AC 230V, 12V / 4.2A)
Overload behaviour Straight V/I characteristic (depending on Vin);
MTBF (Reliability) appr. 600.000h acc. to Siemensnorm SN29500 details see diagr. 'output characteristic' below
(12V / 4.2A, AC 230V, Tamb = +40°C)
Protection Unit is protected against (also permanent) short-
Prior to shipment, every unit undergoes the following tests in order to circuit, overload and open-circuit.
isolate any defective units which might suffer an early failure:
• Run-in / burn-in (Full load, Tamb = +60°C, on/off cycle) Derating depending on built-in orientation;
• Functional test (100%) see diagram below
Power back immunity 22V
X Construction, Mechanics, Installation
Operating indicator Green LED (DC ON)
Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid
on three housing sides to keep out small parts (e.g. screws), IP20 X Environmental Data, EMC, Safety
Dimensions and weight Ambient temperature range (measured 25 mm below unit)
• WxHxD 45mm x 75mm x 91mm (+ DIN Rail)) • storage/transport -25°C ... +85°C
• Weight 260g • operation -10°C ... +70°C (for derating see diagram below)
Mounting orientation , or (cf. ’Output’) Humidity max. 95% (without condensation)
Ventilation/Cooling Normal convection, no fan required Electromagnetic EN 61000-6-3 (includes EN 61000-6-4)
• Free space f. cooling recom’d.: 25mm on sides with ventilation grid emissions (EME) Class B (EN 55011, EN 55022)
Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15). Electromagnetic EN 61000-6-2 (includes EN 61000-6-1)
Unit sits safely and firmly on the rail; no tools required even to remove immunity (EMI)
Connection by Spring Clamp terminals; uniformly firm hold, Safe low voltage: SELV (EN 60950, VDE0100/T.410), PELV (EN 50178)
vibration-resistant and maintenance-free. Prot. class/degree: Class I (EN 60950) / IP20 (EN 60529)
Connector size range The PSU complies with all major safety approvals for EU (EN 60 950,
• flexible cable 0.3-2.5mm2 (28-12 AWG) EN 60204-1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865),
• solid cable 0.3-4mm2 (28-12 AWG) Canada (CAN/CSA-C22.2 No 60950 [CUR],CAN/CSA-C22.2 No. 14 [CUL]),
Ferrules admissible CB Scheme (IEC 60950). NEC Class 2 Power Supply and Hazardous Location
• Wire strip length 6mm (0.24in) recommended Class I Div. 2 (UL 1604)
Design details – for your advantage:
• All terminals are easy to reach as mounted on the front panel.
• Input and output are strictly apart from each other (input below, out-
put above) and so cannot be mixed up.
• Mounting and connection do not require any screwdriver
• A jumper (output terminal) serves to adjust the output voltage
(12V resp. 15V).
X Diagrams
Output characteristic Vout/Iout Efficiency Derating Hold-up time with ACin
(typ.) (@ Vout = 12V, typ.) of output power (at Vout = 12V, typ. and min.)
16 95
60 120
14 Vout range 90 A
50 100
12 B
85
Output voltage Vout [V]
40 a
Output power [W]
80
Hold-up time [ms]
10
Efficiency [%]
80
8 230 V ACin 30 b 60
75 Mounting
6 85-150 V ACin A-a A-a A-c c
100 V ACin 20 40 50W typ.
70
230 V ACin 150-264 V ACin A-a A-a A-b 50W min.
4
100 V ACin 100-375 V DCin A-a A-a A-b 25W typ.
65 10 20 25W min.
2 85 V DCin A-b B-b B-c
0
60 0 0
0,2 0,6 1 1,4 1,8 2,2 2,6 3 3,4 3,8 4,2 -10 0 10 20 30 40 50 60 70 85 105 125 145 165 185 205 225
0 1 2 3 4 5 6
Output current Iout [A] Output current Iout [A] Ambient temperature [ °C] Input voltage V ACin [V]
Product information (ML50e102), Rev.: 17. September 2020. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in
time. They are subject to change without prior notice.
PULS GmbH, Elektrastraße 6, D-81925 München X Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-299, E-Mail: sales@puls-power.com X www.puls-power.com