Typical Detail Riser Diagram: General Notes

The document provides general notes for all electrical works including compliance with codes, supervision requirements, coordination with other drawings, mounting heights, material requirements, and coordination with utilities.

Uploaded by

Mary Feliciano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views2 pages

Typical Detail Riser Diagram: General Notes

The document provides general notes for all electrical works including compliance with codes, supervision requirements, coordination with other drawings, mounting heights, material requirements, and coordination with utilities.

Uploaded by

Mary Feliciano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

GENERAL NOTES:

1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE THE RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL
UTILITY COMPANY.
2. ALL FOLLOWING NOTES SHALL APPLY TO ALL ELECTRICAL DRAWINGS UNLESS OTHERWISE INDICATED.
3. ALL ELECTRICAL WORKS SHALL BE UNDER DIRECT AND IMMEDIATE SUPERVISION BY A DULY AUTHORIZED ELECTRICAL ENGINEER.
4. THE ELECTRICAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE REST OF THE DRAWINGS PERTAINING TO
ARCHITECTURAL, STRUCTURAL AND SANITARY AND OTHER PERTAINING INFORMATION AS APPLICABLE.
5. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE IN MILLIMETERS.
6. ALL EXPOSED NON CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED.
7. ALL ELECTRICAL MATERIALS SHALL COMPLY IN FULL WITH THE PHILIPPINE ELECTRICAL CODES AND CODES OF PRACTICE.
8. ALL ELECTRICAL MATERIALS TO BE USED SHALL BE NEW AND INSTALLED IN APPLICATIONS FOR WHICH THEY ARE INTENDED.
9. UNLESS OTHERWISE INDICATED MOUNTING HEIGHTS GIVEN SHALL BE MEASURED AS FOLLOWS:
9.1. EQUIPMENT- FROM FINISHED FLOOR LINE TO TOP OF EQUIPMENT.
9.2. WIRING DEVICES- FROM FINISHED FLOOR LINE TO CENTER OF DEVICE.
10. ALL WIRES, CONDUITS, BREAKERS, SWITCHES, WIRING DEVICES AND OTHERS MUST BE LISTED OR IEC APPROVED TYPE.
11. THE CONTRACTOR SHALL BE REQUIRED TO COORDINATE WITH OTHER TRADES NECESSARY TO CARRY OUT THE ELECTRICAL
INSTALLATION WORK.
12. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF THE SERVICE ENTRANCE FOR CONNECTION TO
POWER SUPPLY AND OTHER UTILITIES INCLUDED IN THE PLAN.

CONCRETE SLAB

PULLBOX
600MM(L) X 400MM(W) X 150MM(D)

CONDUIT WITH

LOCKNUT & BUSHING

CONDUIT SUPPORT
USING U-BOLT AND

ANGLE BAR

CONDUIT, RSC/EMT
SURFACE MOUNTED
SOCKET LAYOUT STANDARD
NTS

CHEST
FREEZER

SWITCHES

2.0 m
CHILLER LOCKNUT & BUSHING

0.5 m
RTD/RTE

1.2m
SERVICE ENTRANCE 2 - 30mm² THHN WIRE (L) + STANDARD
1-Phase, 220V, 60Hz 1 - 8.0mm² THHN WIRE (G)
FRONT LOOK KITCHEN OUTLETS MAIN
2 wires + grounding in 32mm RSC SMO A D

NOWHERE
NTS DETAILS

GOING
PANEL BOARD
SIGNAGE
2 - 5.5mm² THHN WIRE (L) +
NIGHT
B E PYLON
1 - 3.5mm² THHN WIRE (G)
in 25mm Ø PVC LIGHT C F POST
1400mm

2 - 30mm² THHN WIRE (L) +


1 - 8.0mm² THHN WIRE (G)
in 32mm RSC
LOCKNUT & BUSHING
3 SWITCH BANK DETAIL 4 STORAGE
CONDUIT, RSC/EMT E-1 N T S E-1 N T S
ECB
40AT,2P

M MTS COUPLING
100AT,2P

100AT,2P

ECB
100AT,2P

30AT,2P 30AT,2P

CKT. # 1 CKT. # 2 G
30AT,2P 30AT,2P
5kVA GENERATOR SET
CKT. # 3 CKT. # 4 PROVIDED BY SALES
30AT,2P 20AT, 2P

CKT. # 5 CKT. # 6 LOCATION: PORCH AREA


20AT, 2P 20AT, 2P

CKT. # 7 CKT. # 8
20AT, 2P 20AT, 2P

CKT. # 9 CKT. # 10
20AT, 2P 20AT, 2P

CKT. # 11 CKT. # 12
20AT, 2P 20AT, 2P

CKT. # 13 CKT. # 14
20AT, 2P 20AT, 2P

CKT. # 15 CKT. # 16
LOCATION: PARKING AREA 20AT, 2P 20AT, 2P

CKT. # 17 CKT. # 18

LOCATION: SMO

1 RISER DIAGRAM
SCALE: NOT TO SCALE
E-1
2 TYPICAL DETAIL
SCALE: NOT TO SCALE
E-1

ENGINEER: REPUBLIC ACT 9266 ARTCLE IV SECTION 33


DRAWING AND SPECIFICATIONS DULY SIGNED, STAMPED OR SEALEDAS INSTRUMENTS OF SERVICE
PROJECT TITLE: OWNER: REVISIONS: SHEET CONTENT: SHEET NO.
ARE THE INTELLECTUAL PROPERTIES & DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT
DATE:
HELI AGON CONSTRUCTION LOAD SCHEDULE
THE CONSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR
BUILDINGS, WHETHER EXECUTED PARTLY OR INWHOLE.

OFFICE ADDRESS: BRGY. GULOD SAN RAFAEL BULACAN PRESIDENTIAL DECREE NO. 49 " PROTECTION OF INTELLECTUAL PROPERTY " NOV. 14 1974 O!SAVE KALIGAYAHAN, NOVALICHES OSAVE TRADING DRAWN BY: RISER DIAGRAM

E
WORKS OF ARTS, ARCHITECTURE, MODELS AND DESIGNARE CREATIVE WORK AND CONSIDERED AS PART OF
Email Address: helixagonconstruction05@gmail.com
Mobile No.: 0927.637.1514 / 02.7117.42.89
THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER PD 49
PHILIPPINES CORPORATION DATE: CONVENIENCE OUTLET DETAILS
PRC NO.: DATE: REPUBLIC ACT 8293 INTELLECTUAL PROPERTY LAW SECTION 186 LOCATION: REVIEWED BY:
WORK OF ARCHITECTURE - COPYRIGHT IN A WORK OF ARCHITECTURE SHALL INCLUDE THE RIGHT TO
PTR NO.: ISSUED ON: CONTROL THE ERECTION OF ANY BUILDING WHICH REPRODUCES THE WHOLE OR A SUBTANTIAL PART OF DATE:
THE WORK EITHER IN ITS ORIGINAL FORM OR IN ANY FORM RECOGNIZABLY DERIVED FROM THE ORIGINAL.
KALIGAYAHAN, NOVALICHES, QUEZON CITY
ISSUED AT: TIN NO.: PLOTTING DATE:
6"Ø RECESSED DOWNLIGHT WITH DIE CASTED
ALUMINUM FRAME SILVER BRIGHT ANODIZED
Sa SINGLE GANG SWITCH
d REFLECTOR & 6WATTS 'PHILIPS' COOL WHITE LED

ECOLUMBOX TYPE SET; WHITE WITH


18W T8 4FT. LED LAMP/BULB;DAYLIGHT Sbc TWO GANG SWITCH

Sdef THREE GANG SWITCH

L FLOOD LIGHT P-16 HOMERUN CIRCUIT

INDUSTRIAL DESIGN DROPLIGHT


BLK WITH LED BULB 5W AIRCON OUTLET

E EXHAUST DUCT FAN


TELEPHONE OUTLET

E 1
TRACKLIGHT BLK 361 W MR16 LED 3W COB
WITH 1M TRACK BAR DUPLEX CONVENIENCE OUTLET
WALL FAN AT 1.8M HEIGHT

GON 1676
DO
91 X LA GO
0

EL
77 NDO SIGNAGE EMERGENCY LIGHT LOCATION
91 X LA GO

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA


77 NDO

91 X 77
91 X LA GO
1676 77 NDO
0 91 X LA GO

4580
77 NDO ONE -16" ORBIT FAN BANANA TYPE (STANDARD
91 X LA GO

1520

90°
77 NDO MODEL: SOF-16B) CCTV LOCATION
91 X LA GO

91 X 77
E.L. 77 NDO
91 X LA GO

4580
77 NDO

1520
91 X LA GO
A
77 ND
91 X OLA GO
FCU 5

91 X 77
77 ND
91 X OLA GO

1520
77 ND
91 X OLA GO
77 ND
B 91 X OLA GO
77 ND

GONDOLA GONDOLA GONDOLA

GONDOLA GONDOLA GONDOLA


D

91 X 77
91 X OLA GO

1520

91 X 77

91 X 77
77 ND
91 X OLA

700
A 77 2

1520
D

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA


91 X 77
FCU 4

91 X 77

91 X 77

91 X 77

91 X 77

1100
FIRE

310
A B A B

1520
EXIT
730
a A

91 X 77

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA


91 X 77

91 X 77
91 X 77

91 X 77
4470

91 X 77

91 X 77

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA
E F

91 X 77
P-6 B
1200

FCU 3 3

91 X 77

91 X 77
1050 1400 2000 1300 2020 1400 1900 1400 1030
4470

91 X 77

91 X 77
P-3

1520

91 X 77
1500
1200
B A B A B A B A

91 X 77

91 X 77

91 X 77

91 X 77
730 5

91 X 77
b

GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA GONDOLA


1854 X 856
P-5

91 X 77
C

7640
FREEZER
D CHEST

91 X 77

91 X 77

91 X 77

91 X 77
1200
AHT

91 X 77
1200

E.L.

91 X 77
4

E.L.

7640
P-4

7410
91 X 77

91 X 77
1200

2102 X 856
2102 X 856

91 X 77

91 X 77
FREEZER

FREEZER
CHEST

CHEST

91 X 77
AHT

AHT
91 X 77
730
A B A B A B A B
a

91 X 77

91 X 77

91 X 77

91 X 77
0

493
2413

91 X 77
b
E P-13

91 X 77

PROVISION FOR
1200
AHT
1200 2
1200

MAIN SIGN
P-14
0

CHEST

91 X 77

91 X 77
STORAGE P-2
0

493

91 X 77

91 X 77
FREEZER
2413

91 X 77
AREA 1854 X 856

PROVISION FOR

91 X 77
ELV +400MM

1200

MAIN SIGN
STORAGE 3

91 X 77

91 X 77
FCU 2 FCU 1 1

91 X 77

91 X 77

S T R E E T
AREA B A B A B A B A

91 X 77
730

S A L V I A
b P-1

91 X 77
a
P-15 D B P-15 GONDOLA
GONDOLA

S T R E E T
91 X 77

91 X 77
S A L V I A
1200 ORBIT FAN 91 X 77

1200
1200

c
B

91 X 77
1200
E.L. SELLING AREA
ELV +400MM
730 C C C C C C C
a

0
4870
486
1280

91 X 77
b SELLING AREA

4530
ELV +400MM
MOP
P-12
E SMO
1200

SINK
1200

1200

7760
0
4870
486

91 X 77
TOILET
P-11
EF-2 SMO P-7

1200

7760
E.L.

CARTON D1
730

VAULT
CAGE
b C C C C C C C C DELIVERY 800X1000 PACKING TABLE PACKING TABLE
650 DVR
350 X 2000 350 X 2000
ACCESS
A P-15 P-16
700

d ROLL-UP DOOR
1050 1400 2000 1300 2020 1400 1900 1400 1020 D
680
1100 480 1800 1550 4440 1420 1800 1420 4600 1000
EF-1 P-10
E.L. E.L.
PORCH AREA

A ROLL-UP DOOR
F
ELV +385MM

MAIN SIGN
460 D 1200 E 1200 D 1200 E 1200 D 1200 E 1200 1200 E P-8
UNLOADING

1600
528
signage MAIN SIGN BAY 4

5000
P-9

2220
F F ELV +385MM PWD
RAMP
0
528

PWD PARKING
1500 PARKING AREA
WITH PWD LOGO
ELV +200MM
AT THE CENTER
PYLON 900
SIGNAGE

00
40
PYLON
SIGNAGE 00 6 5
40
SERVICE
ENTRANCE

19630 2000
SERVICE
ENTRANCE

19630 5 4 3 2 1
5 4 3 2 1
Q U I R I N O
H I G H W A Y

1 LIGHTING LAYOUT 2 POWER LAYOUT


E 2 SCALE : 1:100 M
E 2 SCALE : 1:100M

ENGINEER: REPUBLIC ACT 9266 ARTCLE IV SECTION 33


DRAWING AND SPECIFICATIONS DULY SIGNED, STAMPED OR SEALEDAS INSTRUMENTS OF SERVICE
PROJECT TITLE: OWNER: REVISIONS: SHEET CONTENT: SHEET NO.
ARE THE INTELLECTUAL PROPERTIES & DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT

HELI AGON CONSTRUCTION DATE: LOAD SCHEDULE


THE CONSENT OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR

OFFICE ADDRESS: BRGY. GULOD SAN RAFAEL BULACAN


BUILDINGS, WHETHER EXECUTED PARTLY OR INWHOLE.

PRESIDENTIAL DECREE NO. 49 " PROTECTION OF INTELLECTUAL PROPERTY " NOV. 14 1974
O!SAVE KALIGAYAHAN, NOVALICHES OSAVE TRADING DRAWN BY: RISER DIAGRAM
Email Address: helixagonconstruction05@gmail.com
E
WORKS OF ARTS, ARCHITECTURE, MODELS AND DESIGNARE CREATIVE WORK AND CONSIDERED AS PART OF

Mobile No.: 0927.637.1514 / 02.7117.42.89


THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED UNDER PD 49
PHILIPPINES CORPORATION DATE: CONVENIENCE OUTLET DETAILS
PRC NO.: DATE: REPUBLIC ACT 8293 INTELLECTUAL PROPERTY LAW SECTION 186 LOCATION: REVIEWED BY:
WORK OF ARCHITECTURE - COPYRIGHT IN A WORK OF ARCHITECTURE SHALL INCLUDE THE RIGHT TO
PTR NO.: ISSUED ON: CONTROL THE ERECTION OF ANY BUILDING WHICH REPRODUCES THE WHOLE OR A SUBTANTIAL PART OF
KALIGAYAHAN, NOVALICHES, QUEZON CITY DATE:
THE WORK EITHER IN ITS ORIGINAL FORM OR IN ANY FORM RECOGNIZABLY DERIVED FROM THE ORIGINAL.

ISSUED AT: TIN NO.: PLOTTING DATE: