PART D 262

PART - D
Schedule of Quantities

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 263

SCHEDULE OF QUANTITIES

Name of Work: Construction of Indoor Stadium for National Centre for Indian
Maritime University, Vanagali (V), Sabbavaram (M), Visakhapatnam, A.P. including
internal and external water supply, sanitary installations, drainage, internal roads, UG
sump, IEI & Fans, Water Coolers, Split type AC units, Fire Fighting with Downcomer
system, Addressable Fire Alarm System, CCTV System, LAN System and AV system
etc.

Civil Component
Sl. No Description Quantity Unit Rate Amount
1 EARTH WORK
1.1 Earth work in excavation by
mechanical means (Hydraulic
excavator)/ manual means over
areas (exceeding 30 cm in depth,
1.5 m in width as well as 10 sqm on
plan) including getting out and
disposal of excavated earth for all
leads and lifts within the campus,
as directed by Engineer-in-charge.
1.1.1 All kinds of soil 2500.00 cum 198.80 497000.00
1.2 Earth work in excavation by
mechanical means (Hydraulic
excavator) / manual means in
foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm
on plan), including dressing of
sides and ramming of bottoms, for
all lift, including getting out the
excavated soil and disposal of
surplus excavated soil as directed,
for all leads within the campus.
1.2.1 All kinds of soil 100.00 cum 291.54 29154.00
1.3 Excavating trenches by mechanical
/ manual means of required width
for pipes, cables, etc. including
excavation for sockets, and
dressing of sides, ramming of
bottoms, for all depths including
getting out the excavated soil, and
then returning the soil as required,
in layers not exceeding 20 cm in
depth, including consolidating
each deposited layer by ramming,
watering, etc. and disposing of
surplus excavated soil as directed,
for all leads within the campus
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 264

Sl. No Description Quantity Unit Rate Amount


1.3.1 All kinds of soil
1.3.1.1 Pipes, cables etc. exceeding 80 mm 200.00 metre 394.41 78882.00
dia but not exceeding 300 mm dia
1.4 Filling available excavated earth 2500.00 cum 219.52 548800.00
(excluding rock) in trenches, plinth,
sides of foundations etc. in layers
not exceeding 20cm in depth,
consolidating each deposited layer
by ramming and watering, for all
leads and lifts within the campus
1.5 Excavating, supplying and filling 1600.00 cum 466.50 746400.00
of local earth (including royalty) by
mechanical transport for all leads
and lifts including ramming and
watering of the earth in layers not
exceeding 20 cm in trenches, plinth,
sides of foundation etc. complete
for all lift.
Note:
i) Source of earth is the
responsibility of the Agency.
ii) Quality of earth is to be got
approved by the Engineer in
Charge before procuring.
iii) The rate is inclusive of royalty,
transportation for all leads and lifts
and all other incidental charges. No
additional clams will be admissible.
1.6 Supplying and filling in plinth with 90.00 cum 2378.60 214074.00
river sand under floors, including
watering, ramming, consolidating
and dressing complete.
1.7 Providing and laying 125-micron 1200.00 sqm 22.57 27084.00
thick Polyethylene sheet
(separation membrane) below the
Cement Concrete in under floors
and CC Pavements etc. all
complete as directed by the
Engineer in charge. The overlaps
of sheet at sheet joint shall not be
less than 100mm.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 265

Sl. No Description Quantity Unit Rate Amount


1.8 Structural analysis and design of
the buildings and supply of six sets
all good for construction structural
drawings, conforming to all
relevant provision of National
Buildings code 2016 and other
relevant codes of practice of Bureau
of Indian Standards including
proof checking the designs and
drawings from Andhra University
Vizag/ JNTU Kakinada/ JNTU
Hyd/NIT Warangal/ IIT Chennai/
SVU Tirupati or any other Govt
Engineering college. The design
work also involves design of
foundations and development of
structural detailing drawings for
RCC framed structure, foundation
to be designed for future extension
floors of the building if any,
basements, retaining walls, terrace
water tanks and staircase head
rooms, lift rooms, sump, septic
tank etc., if any all complete
Conventional method construction
of the building, The work shall be
carried out as per the particular
specifications special conditions
and directions of Engineer-in-
charge.Plinth area of the building
in the present scope shall be
measured for payment.
1.8.1 Multi-storeyed RCC building 1430.00 sqm 50.00 71500.00
2 CONCRETE WORK
2.1 Providing and laying in position
cement concrete of specified grade
excluding the cost of centering and
shuttering - All work up to plinth
level:
Note: If the agency wants to
procure the concrete from the RMC
plant, they can procure with prior
approval of the design mix and
RMC plant from the Engineer in
charge. No additional clams will be
admissible in this regard.
2.1.1 1:5:10 (1 Portland Pozzolana 60.00 cum 7300.83 438050.00
cement: 5 coarse sand (zone-III): 10
graded stone aggregate 40 mm
nominal size)

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 266

Sl. No Description Quantity Unit Rate Amount


2.2 Providing and laying cement
concrete in retaining walls, return
walls, walls (any thickness)
including attached pilasters,
columns, piers, abutments, pillars,
posts, struts, buttresses, string or
lacing courses, parapets, coping,
bed blocks, anchor blocks, plain
window sills, fillets, sunken floor
etc., up to floor five level,
excluding the cost of centering,
shuttering and finishing:
Note: If the agency wants to
procure the concrete from the RMC
plant, they can procure with prior
approval of the design mix and
RMC plant from the Engineer in
charge. No additional clams will be
admissible in this regard.
2.2.1 1:2:4 (1 Portland Pozzolana 1.00 cum 11082.62 11083.00
Cement: 2 coarse sand (zone-III)
derived from natural sources: 4
graded stone aggregate 20 mm
nominal size derived from natural
sources)
2.3 Centering and shuttering including
strutting, propping etc. and
removal of form work for :
2.3.1 Foundations, footings, bases for 70.00 sqm 439.21 30745.00
columns
2.4 Making plinth protection 50 mm 140.00 sqm 839.22 117491.00
thick of cement concrete 1:3:6 (1
Portland Pozzolana Cement :3
coarse sand: 6 graded stone
aggregate 20 mm nominal size)
over 75 mm thick bed of dry brick
ballast 40 mm nominal size, well
rammed and consolidated and
grouted with fine sand, including
necessary excavation, levelling &
dressing and finishing the top
smooth.
3 REINFORCED CEMENT
CONCRETE
3.1 Centering and shuttering including
strutting, propping etc. and
removal of form for:
3.1.1 Foundations, footings, bases of 300.00 sqm 439.21 131763.00
columns, etc. for mass concrete

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 267

Sl. No Description Quantity Unit Rate Amount


3.1.2 Walls (any thickness) including 280.00 sqm 943.60 264208.00
attached pilasters, butteresses,
plinth and string courses etc.
3.1.3 Suspended floors, roofs, landings, 625.00 sqm 1038.52 649075.00
balconies and access platform
3.1.4 Lintels, beams, plinth beams, 470.00 sqm 824.77 387642.00
girders, bressummers and
cantilevers
3.1.5 Columns, Pillars, Piers, Abutments, 700.00 sqm 1076.66 753662.00
Posts and Struts
3.1.6 Stairs, (excluding landings) except 20.00 sqm 856.74 17135.00
spiral-staircases
3.1.7 Small lintels not exceeding 1.5 m 50.00 sqm 439.21 21961.00
clear span, moulding as in cornices,
window sills, string courses, bands,
copings, bed plates, anchor blocks
and the like
3.1.8 Edges of slabs and breaks in floors
and walls
3.1.8.1 Under 20 cm wide 50.00 metre 233.58 11679.00
3.1.9 Weather shade, Chajjas, corbels 50.00 sqm 1065.23 53262.00
etc., including edges for
ornamental work
3.3 Steel reinforcement for R.C.C. work
including straightening, cutting,
bending, placing in position and
binding all complete up to plinth
level.
3.3.1 Thermo-Mechanically Treated bars 45000.00 kg 120.79 5435550.00
of grade Fe-500D or more
3.4 Steel reinforcement for R.C.C. work
including straightening, cutting,
bending, placing in position and
binding all complete above plinth
level.
3.4.1 Thermo-Mechanically Treated bars 40000.00 kg 120.79 4831600.00
of grade Fe-500D or more.
3.5 Extra for using high strength 85000.00 kg 3.57 303450.00
Corrosive Resistant Steel bars of
grade Fe-500D or more for
reinforcement in RCC work instead
of Thermo-Mechanically Treated
bars of grade Fe-500D or more
3.6 Add for plaster drip course/ 120.00 metre 87.81 10537.00
groove in plastered surface or
moulding to R.C.C. projections.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 268

Sl. No Description Quantity Unit Rate Amount


3.7 Providing and laying in position
ready mixed or site batched design
mix cement concrete for reinforced
cement concrete work; using coarse
aggregate and fine aggregate
derived from natural sources,
Portland Pozzolana / Ordinary
Portland /Portland Slag cement,
admixtures in recommended
proportions as per IS: 9103 to
accelerate / retard setting of
concrete, to improve durability and
workability without impairing
strength; including pumping of
concrete to site of laying, curing,
carriage for all leads; but excluding
the cost of centering, shuttering,
finishing and reinforcement as per
direction of the engineer-in-charge;
for the following grades of
concrete.
Note: Extra cement up to 10% of
the minimum specified cement
content in design mix shall be
payable separately. In case the
cement content in design mix is
more than 110% of the specified
minimum cement content, the
contractor shall have discretion to
either re-design the mix or bear the
cost of extra cement
3.7.1 All work up to plinth level.
3.7.1.1 Concrete of M15 grade with 90.00 cum 10064.49 905804.00
minimum cement content of 240 kg
/cum
3.7.1.2 Concrete of M30 grade with 395.00 cum 10814.38 4271680.00
minimum cement content of 350 kg
/cum

3.7.2 All work above plinth level up to


floor five level.

3.7.2.1 Concrete of M30 grade with 570.00 cum 11212.71 6391245.00


minimum cement content of 350 kg
/cum
3.8 Add/ deduct for using extra/less 180.00 quintal 821.52 147874.00
cement in the items of design over
the specified cement content
therein.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 269

Sl. No Description Quantity Unit Rate Amount


4 MASONRY WORK
4.1 Brick work with common burnt
clay F.P.S. (non modular) bricks of
class designation 5.0 in foundation
and plinth in:
4.1.1 Cement mortar 1:6 (1 Portland 30.00 cum 7988.12 239644.00
Pozzolana cement: 6 coarse sand)
4.2 Brick work with non modular fly
ash cement bricks conforming to
IS:12894, class designation 7.5
average compressive strength in
super structure above plinth level
up to floor V level in :
4.2.1 Cement mortar 1:6 (1 Portland 325.00 cum 9802.86 3185930.00
Pozzolana cement: 6 Coarse sand)
4.3 Brick edging 7cm wide 11.4 cm 140.00 metre 68.15 9541.00
deep to plinth protection with
common burnt clay F.P.S. (non
modular) bricks of class
designation 5.0 including grouting
with cement mortar 1:4 (1 Portland
Pozzolana cement: 4 fine sand).
4.4 Half brick masonry with non
modular fly ash cement bricks of
class designation 7.5, conforming to
IS :12894, in super structure above
plinth and up to floor V level.
4.4.1 Cement mortar 1: 4 (1 Portland 60.00 sqm 1238.50 74310.00
Pozzolana cement: 4 coarse sand)
5 CLADDING WORK
5.1 Providing and fixing 18 mm thick
gang saw cut, mirror polished, pre
moulded and pre polished,
machine cut for lab platforms,
vanity counters, window sills,
facias and similar locations of
required size, approved shade,
colour and texture laid over 20 mm
thick base cement mortar 1:4 (1
Portland Pozzolana cement : 4
coarse sand), joints treated with
white cement, mixed with
matching pigment, epoxy touch
ups, including rubbing, curing,
moulding and polishing to all
exposed edges to give high gloss
finish including making hole in lab
platform for gas cylinder pipe etc.
complete at all levels.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 270

Sl. No Description Quantity Unit Rate Amount


5.1.1 Granite stone slab colour black,
Cherry/Ruby red/ Tan brown
5.1.1.1 Area of slab to be measured 40.00 sqm 5752.66 230106.00
5.2 Extra for providing opening of 5.00 each 1096.14 5481.00
required size & shape for wash
basin/ kitchen sink in kitchen
platform, vanity counter and
similar location in marble/
Granite/ stone work, including
necessary holes for pillar taps etc.
including moulding, rubbing and
polishing of cut edges etc.
complete.
5.3 Providing and fixing stone slab
with table rubbed, edges rounded
and polished on both sides and of
size 75x50 cm deep and 1.8 cm
thick, fixed in urinal partitions by
cutting a chase of appropriate
width with chase cutter and
embedding the stone in the chase
with epoxy grout or with cement
concrete 1:2:4 (1 Portland
Pozzolana cement: 2 coarse sand: 4
graded stone aggregate 6 mm
nominal size) as per direction of
Engineer-in-charge and finished
smooth.
5.3.1 Granite Stone of approved shade 2.00 sqm 4538.07 9076.00
6 WOOD WORK
6.1 Providing wood work in frames of
doors, windows, clerestory
windows and other frames,
wrought framed and fixed in
position with hold fast lugs or with
dash fasteners of required dia &
length (hold fast lugs or dash
fastener shall be paid for
separately).
6.1.1 The quality of teak wood shall be 3.50 cum 158981.44 556435.00
superior than the second-class teak
wood.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 271

Sl. No Description Quantity Unit Rate Amount


6.2 Providing and fixing panelled or
panelled and glazed shutters for
doors, windows and clerestory
windows, fixing with bright
finished brass butt hinges of size
125x85x5.5 mm (heavy type) with
necessary brass screws, excluding
panelling which will be paid for
separately, all complete as per
direction of Engineer-in-charge.
Note: The shutters are to be
provided as per the Pattern/
drawing approved by the Engineer
in Charge.
6.2.1 The quality of teak wood shall be
superior than the second-class teak
wood.
6.2.1.1 35 mm thick shutters 3.60 sqm 4605.38 16579.00
6.3 Providing and fixing panelling or
panelling and glazing in panelled
or panelled and glazed shutters for
doors, windows and clerestory
windows (Area of opening for
panel inserts excluding portion
inside grooves or rebates to be
measured). Panelling for panelled
or panelled and glazed shutters 25
mm to 40 mm thick:
6.3.1 Float glass panes
6.3.1.1 8mm thick glass panes (weight not 8.50 sqm 2942.58 25012.00
less than 20 kg/sqm).
6.4 Extra for acid etching on the float 8.50 sqm 802.86 6824.00
glass panes of approved patterns,
emblems, etc. complete all as
directed by Engineer in charge.
6.5 Providing and fixing factory made
single extruded WPC (Wood
Polymer Composite) solid door/
Window /Clerestory windows &
other Frames /Chowkhat
comprising of virgin PVC polymer
of K value 58-60 (Suspension
Grade), calcium carbonate and
natural fibers (wood powder/rice
husk/wheat husk) and nontoxic
additives (maximum toxity index
of 12 for 100 gms) fabricated with
miter joints after applying PVC
solvent cement and screwed with
full body threaded star headed

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 272

Sl. No Description Quantity Unit Rate Amount


SS screws having minimum frame
density of 750 Kg / Cum, Screw
withdrawal strength of 2200 N
(Face) and 1100 N (Edge),
minimum compressive strength of
58 N/mm2, modulus of elasticity
900N/mm2 and resistance to
spread of flame of Class A category
with property of being
termite/borer proof,
water/moisture proof and fire
retardant and fixed in position with
M.S. hold fast/lugs/SS dash
fasteners of required dia and length
complete as per direction of
Engineer-in-Charge. (M.S. hold
fast/lugs or SS dash fasteners shall
be paid for separately).
Note: For WPC solid door /
window frames, minus 5mm
tolerance in dimensions i.e., depth
and width of profile shall be
acceptable. Variation in profile
dimensions on Plus side shall be
acceptable but no extra payment on
this account shall be made:
6.5.1 Frame size 45 x 85 mm 50.00 metre 1037.51 51876.00
6.6 Providing and fixing factory made
single extruded WPC (Wood
Polymer Composite) solid plain
flush door shutter of required size
comprising of virgin polymer of K
value 58-60 (Suspension Grade),
calcium carbonate and natural
fibres (wood powder/ rice
husk/wheat husk) and nontoxic
additives (maximum toxicity index
of 12 for 100 gms) having
minimum density of 650 kg/cum
and screw withdrawal strength of
1800 N (Face) & 900 N (Edge),
minimum compressive strength 50
N/mm2, modulus of elasticity 850
N/mm2 and resistance to spread of
flame of Class A category with
property of being termite/borer
proof, water/moisture proof and
fire retardant and fixing with
stainless steel butt hinges of
required size with necessary full
body threaded star headed counter
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 273

Sl. No Description Quantity Unit Rate Amount


sunk S.S screws, all as per direction
of Engineer-In- Charge. (Note:
stainless steel butt hinges and
necessary S.S screws shall be paid
separately)
6.6.1 30 mm thick 14.00 sqm 4868.30 68156.00
6.7 Providing and fixing M.S. grills of
required pattern in frames of
windows etc. with M.S. flats,
square or round bars, etc. including
super durable powder coating of
minimum 60 microns conforming
to AAMA 2604 of required colour
and shade as approved by the
Engineer-in-Charge.
6.7.1 Fixed to openings /uPVC windows 625.00 kg 367.73 229831.00
/wooden frames with rawl plugs
screws etc.
6.8 Providing and fixing IS: 12817
marked stainless steel butt hinges
(Heavy weight) with stainless steel
screws etc. Complete
6.8.1 75x47x2.50 mm (for WPC door) 40.00 each 100.02 4001.00
6.9 Providing and fixing Antique 2.00 each 5345.65 10691.00
finished decorative brass Sliding
Door bolts of size 450 x 16mm with
necessary nuts and screws etc.
complete as approved by the
Engineer in charge.
6.10 Providing and fixing Antique 3.00 each 5565.16 16695.00
finished decorative brass handles
of required size with necessary
screws etc. complete as approved
by the Engineer in charge. - 450mm
x 20mm
6.11 Providing and fixing bright
finished brass tower bolts (barrel
type) with necessary screws etc.
complete:
6.11.1 250x10 mm 3.00 each 494.59 1484.00
6.12 Providing and fixing bright 2.00 each 136.25 273.00
finished brass hanging type floor
door stopper (heavy type) with
necessary screws, etc. complete as
approved by the Engineer in
charge.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 274

Sl. No Description Quantity Unit Rate Amount


6.13 Providing and fixing aluminium 19.00 each 1101.13 20921.00
extruded section body tubular type
universal hydraulic door closer
(having brand logo with ISI mark,
IS: 3564, embossed on the body,
door weight up to 36 kg to 80 kg
and door width from 701 mm to
1000 mm), with double speed
adjustment with necessary
accessories and screws etc.
complete.
6.14 Providing and fixing factory made
uPVC glazed/wire mesh
windows/doors comprising of lead
free uPVC multi-chambered frame,
sash and mullion/coupler (where
ever required) extruded profiles
having minimum wall thickness of
1.70 mm for series R1 and R2
profiles and 2.10 mm for series R3
and R4 profiles conforming to EN:
12608 in any shape, colour and
design duly reinforced with
galvanized mild steel section made
of required shape & size as per
CPWD specification, uPVC
extruded glazing beads, interlocks
and inline sash adaptor (where
ever required) of appropriate
dimension EPDM gasket,
hardware, SS304 grade fasteners of
minimum 8 mm dia x 75mm length
with countersunk head, comprising
of matching polyamide PA6 grade
sleeve for fixing frame to finished
wall as per IS 1367 : part 1 to 14
plastic packers, plastic caps and
necessary stainless steel screws etc.
Profile of frame, sash & mullion (if
required) shall be mitred cut and
fusion welded/mechanically
jointed duly sealed at all corners,
including drilling of holes for
fixing hardware and drainage of
water etc.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 275

Sl. No Description Quantity Unit Rate Amount


After fixing frame the gap between
frame and adjacent finished wall
shall be filled with weather proof
silicon sealant over backer rod of
approved size and quality, all
complete as per approved
drawings conforming to CPWD
specification & direction of
Engineer-in-charge. section of steel
reinforcement and cross section of
uPVC profiles to be as per design
approved by Engineer-in-charge.
Wire mesh/ glazing of plain/
toughened/ laminated/ double
glass unit with /without high
performance coatings as per design
requirements and conforming to IS:
3548 & IS: 16231 shall be paid
separately.
Note: structural design proof
checked from a Government
Engineering institute, to be
provided by the manufacturer for:
i) Sites with basic wind speed >
45m/ sec as per IS 875 - Part3.
ii) Sites with structures height more
than 20 m for all wind speeds.
6.14.1 Two track two panels sliding
window with Aluminium channel
for roller track, wool pile, nylon
rollers with SS 304 body.
6.14.1.1 Using R3 series with frame (55mm 4.00 sqm 9855.16 39421.00
& above) x (40mm & above) & sash
(30mm & above) x (55mm & above)
with zinc alloy (zamak) powder
coated handle on every panel along
with multi-point locking system
(Height up to 1.8m).
6.14.2 Three track three panels sliding
window with two glazed & one
wire mesh panels with Aluminium
channel for roller track, wool pile,
nylon rollers with SS 304 body.
6.14.2.1 Using R3 series with frame (98mm 43.00 sqm 12179.10 523701.00
& above) x (40mm & above) & both
glazed and fly screen sash (30mm
& above) x (55mm & above) with
zinc alloy (zamak) powder coated
handle on every glazed panel along
with multi-point locking system.
(Height up to 1.8m).
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 276

Sl. No Description Quantity Unit Rate Amount


6.14.3 Fixed window/ ventilator with
mullion/ transom.
6.14.3.1 Using R1 series with frame (33mm 22.00 sqm 10253.82 225584.00
& above) x (35mm & above) &
mullion (33mm & above) x (50mm
& above). (Height upto 0.90 metre)
6.15 Providing and fixing glazing in
uPVC door, window, ventilator
shutters, partitions, etc. including
louvers with EPDM
rubber/neoprene gasket, etc.
complete as per the architectural
drawings and the directions of
Engineer-in-charge.
6.15.1 With frosted glass panes of 5.0 mm 18.00 sqm 1883.45 33902.00
thickness (weight not less than 10
kg per sqm).
6.15.2 With float glass panes of 5 mm 38.00 sqm 1685.88 64063.00
thickness (weight not less than
12.50 kg/sqm)
6.15.3 with Stainless steel (grade 316) wire 18.00 sqm 1092.38 19663.00
gauze of 0.5 mm dia wire and 1.4
mm aperture on both sides.
6.16 Providing and fixing bright /matt
finished Stainless Steel handles of
approved quality & make with
necessary screws etc. all complete
6.16.1 125 mm 54.00 each 133.50 7209.00
6.17 Providing and fixing stainless steel 12.00 each 1971.51 23658.00
'H' type pull handle of size
450x25.4mm of Dorset (Code:
SH18PSS) or equivalent make with
SS screws etc. complete as per
direction of Engineer-in-charge.
6.18 Providing and fixing stainless steel 17.00 each 364.89 6203.00
(grade 304) sliding door bolts
(Model: ALD 304 of Dorset make or
equivalent) with necessary nuts
and screws etc. complete: 300x16
mm
6.19 Providing and fixing stainless steel 10.00 each 293.76 2938.00
(grade 304) sliding door bolts
(Model: SDH-TDH-25012 of Dorset
make or equivalent) with necessary
nuts and screws etc. complete:
250x12 mm
6.20 Providing and fixing stainless steel 58.00 each 221.79 12864.00
(grade 304) tower bolt (Code: 3264
of Godrej make or equivalent) with
necessary screws etc. complete:
300x10 mm
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 277

Sl. No Description Quantity Unit Rate Amount


6.21 Providing and fixing stainless steel 10.00 each 513.43 5134.00
(grade 304) baby latch with SS lock
strip - 125mm (Code: BL(B) of
Dorset make or equivalent) with
necessary screws etc. complete:
6.22 Providing and fixing bright /matt 23.00 each 301.41 6932.00
finished Stainless hanging floor
door stopper of approved quality &
make with necessary screws etc. all
complete.
7 STEEL WORK
7.1 Providing and fixing pressed steel 100.00 metre 778.80 77880.00
door frame of section 125 x 55 mm
having built in rebate made out of
1.6mm thickness (16 SWG) G.I.
sheet confirming to IS:277 with zinc
coating not less than 120 gm/sqm
to provide rust resistance duly
filled with PUF (Polyurethane
Foam) Soudal GEN 750 of McCoy
or equivalent make. All provision
should be mortised, drilled and
tapped for receiving appropriate
hard ware. Rubber door silencer
should be provided on the striking
jamb and top. Frames should be
mitred and field assembled with
self-tabs. Frames to have in build
grooved sealing system and shall
be site fitted with EPDM/PVC
gasket as standard. Frames should
be provided with back plate
bracket and anchor fasteners for
installation on a finished plastered
masonry wall opening. Gaps
between masonry wall/RCC and
frame should be filled with silicone
sealant of approved make. The
frame shall be fixed to masonry
wall / RCC column with 8 Nos.
dash fastener of size 8mmx140mm
(Model: HRD C-8) of HILTI /
FISCHER or equivalent make.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 278

Sl. No Description Quantity Unit Rate Amount


Frames shall be finished with
polyurethane aliphatic grade
powder coating of minimum 50
microns and followed by 100 micro
thick PU paint. of approved colour
and make and paint surface shall
be tested for 500 hours of salt spray
test. Note: 1. The Supply and fixing
as per the requirement of the
Engineer in charge. Single or
Double rebate Door frames shall be
supplied. 2. The shop drawings
shall be prepared and submitted to
the Engineer-in-charge for
approval. 3. The sample door shall
get approval from the Engineer-in-
charge before going for production.
4. the door frame shall be fixed to
walls, RCC columns etc., with
mechanical fastener of HILTI /
FISHER or equivalent make for
which nothing shall be payable
7.2 Providing and fixing Double 42.00 sqm 7620.58 320064.00
shutter /Single leaf 46 mm thick
double skin fully flush pressed
steel door with or without vision
panel manufactured from 0.8 mm
thick GI sheets confirming to IS
277. The internal construction of
the door should be rigid with steel
stiffeners / pads and reinforcement
for receiving appropriate
hardware. The infill material shall
be resin bonded honeycomb core
and filled with polyurethane foam
(PUF) of density not less than 40
kg/cum. All door shutters shall be
factory prepared for receiving
appropriate hardware and
provided with necessary
reinforcement for hinges / locks /
door closers / sliding door bolts /
tower bolts / door stoppers etc.
The edges should be interlocked
with a bending radius of 1.4mm.
For pair of doors astragals has to be
provided on the meeting stile for
both active and inactive leaf.
Wherever applicable, vision light of
6mm thick toughened glass shall be
fixed with steel beading and
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 279

Sl. No Description Quantity Unit Rate Amount


screwed on to the face of rails and
stile.
Necessary gaskets to be used for
holding the glass in position
complete as per direction of the
Engineer-in-charge. Shutters shall
be finished with polyurethane
aliphatic grade powder coating of
minimum 50 microns and followed
by 100-micron thick PU paint of
approved colour and make and
paint surface shall be tested for 500
hours of salt spray test. The rate
including 4 Nos. of 5 knuckle 2 ball
bearing SS butt hinges of size
100x75x3mm of Dorma/ Becker or
equivalent make fixed with SS
screws per shutter. All complete as
per the direction of Engineer-in
charge.
7.3 Structural steel work in single 800.00 kg 131.43 105144.00
section, fixed with or without
connecting plate, including cutting,
hoisting, fixing in position and
applying a priming coat of
approved steel primer all complete.
7.4 Structural steel work riveted, 7500.00 kg 149.74 1123050.00
bolted or welded in built up
sections, trusses and framed work,
including cutting, hoisting, fixing
in position and applying a priming
coat of approved steel primer all
complete.
7.5 Steel work in built up tubular
(round, square or rectangular
hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing
in position and applying a priming
coat of approved steel primer,
including welding and bolted with
special shaped washers etc.
complete.
7.5.1 Hot finished welded type tubes 17500.00 kg 217.73 3810275.00
7.6 Providing and fixing M.S. fan 22.00 each 253.12 5569.00
clamp type I or II of 16 mm dia
M.S. bar, bent to shape with
hooked ends in R.C.C. slabs or
beams during laying, including
painting the exposed portion of
loop, all as per standard design
complete.
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 280

Sl. No Description Quantity Unit Rate Amount


7.7 Providing and fixing circular/ 10.00 each 247.13 2471.00
Hexagonal cast iron or M.S. sheet
box for ceiling fan clamp, of
internal dia 140 mm, 73 mm height,
top lid of 1.5 mm thick M.S. sheet
with its top surface hacked for
proper bonding, top lid shall be
screwed into the cast iron/ M.S.
sheet box by means of 3.3 mm dia
round headed screws, one lock at
the corners. Clamp shall be made
of 12 mm dia M.S. bar bent to
shape as per standard drawing.
7.8 Providing and fixing mild steel 400.00 kg 108.86 43544.00
round holding down bolts with
nuts and washer plates complete.
7.8 Providing and fixing bolts 300.00 kg 178.47 53541.00
including nuts and washers
complete.
7.10 Providing and fixing carbon steel
galvanised (minimum coating 5
micron) dash fastener of 10 mm dia
double threaded 6.8 grade (yield
strength 480 N/mm2), counter
sunk head, comprising of 10 mm
dia polyamide PA 6 grade sleeve,
including drilling of hole in frame,
concrete/ masonry, etc. as per
direction of Engineer-in-charge.
7.10.1 10x120mm 60.00 each 191.46 11488.00
7.11 Providing and fixing stainless steel 200.00 kg 865.09 173018.00
(Grade 316) railing made of Hollow
tubes, channels, plates Connectors,
bushes etc. (No welding is
permitted between vertical posts
and horizontal runners and the
connections shall be through
connectors) including welding in
other areas, grinding, buffing,
polishing and making curvature
(wherever required) and fitting the
same with necessary stainless steel
nuts and bolts complete, i/c fixing
the railing with necessary
accessories & stainless steel dash
fasteners , stainless steel bolts etc.,
of required size, on the top of the
floor or the side of waist slab with
suitable arrangement as per
approval of Engineer-in charge,
(for payment purpose only weight
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 281

Sl. No Description Quantity Unit Rate Amount


of stainless steel members shall be
considered including SS
Connectors but excluding fixing
accessories such as nuts, bolts,
anchor fasteners etc. used for fixing
the railing on steps/landing
Mab/floor slabs)
8 FLOORING
8.1 Providing and laying Anti-skid 40.00 sqm 1489.60 59584.00
rectified ceramic floor tiles 400X400
mm or more (thickness to be
specified by the manufacturer) of
1st quality conforming to IS: 15622
of approved make in all colours,
shades, as approved by Engineer-
in-charge laid on 20 mm thick
Cement Mortar 1:4 (1 Portland
Pozzolana Cement: 4 Coarse sand)
including pointing the joints with
white cement and matching
pigments, etc., complete. (For
flooring of Toilets & Wash area in
basement Floor)
8.2 Providing and fixing Ist quality 210.00 sqm 1420.10 298221.00
rectified ceramic glazed wall tiles
of size 300 x 450mm or 300 x 600
mm Digital Series with Decorative
bands / Highlighters at certain
level conforming to IS: 15622
(thickness to be specified by the
manufacturer), of approved make,
in all colours, shades except
burgundy, bottle green, black of
any size as approved by Engineer-
in-Charge, in skirting, risers of
steps and dados, over 12 mm thick
bed of cement mortar 1:3 (1
Portland Pozzolana cement : 3
coarse sand) and jointing with grey
cement slurry @ 3.3kg per sqm,
including pointing in white cement
mixed with pigment of matching
shade complete.
Kitchen dado if any should have
minimum 30% of concept tiles
indicating vegetable and fruits etc.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 282

Sl. No Description Quantity Unit Rate Amount


8.3 Providing and laying Vitrified tiles
in floor in different sizes (thickness
to be specified by the
manufacturer) with water
absorption less than 0.08% and
conforming to IS:15622, of
approved brand & manufacturer,
in all colours and shade, laid on 20
mm thick cement mortar 1:4 (1
Portland Pozzolana cement: 4
coarse sand) jointing with grey
cement slurry @3.3 kg/sqm
including grouting the joints with
white cement and matching
pigments etc. The tiles must be cut
with the zero-chipping diamond
cutter only. Laying of tiles will be
done with the notch trowel, plier,
wedge, clips of required thickness,
levelling system and rubber mallet
for placing the tiles gently and
easily.
8.3.1 Glazed Vitrified tiles
Matt/Antiskid finish of size
8.3.1.1 Size of Tile 600x600 mm 85.00 sqm 1640.63 139454.00
8.4 Providing and laying Vitrified tiles
in different sizes (thickness to be
specified by manufacturer), with
water absorption less than 0.08 %
and conforming to I.S. 15622, of
approved make, in all colours &
shade, in skirting, riser of steps,
over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse
sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including
grouting the joint with white
cement & matching pigments etc.
complete as per direction of
Engineer-In- Charge.
8.4.1 Size of Tile matching with the 15.00 sqm 1817.82 27267.00
flooring pattern
8.4.2 for dado with Double charge 245.00 sqm 1956.14 479254.00
vitrified tile polished finish of size
1200 x 600 mm tile.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 283

Sl. No Description Quantity Unit Rate Amount


8.5 Providing and laying Polished
Granite stone flooring in required
design and patterns, in linear as
well as curvilinear portions of the
building and staircase treads with
single piece granite stone
including making 3 grooves
parallel to the nosing all complete
as per the architectural drawings
with 18 mm thick stone slab over
20 mm (average) thick base of
cement mortar 1:4 (1 Portland
Pozzolana cement : 4 coarse sand)
laid and jointed with cement slurry
and pointing with white cement
slurry admixed with pigment of
matching shade including rubbing ,
curing and polishing etc. all
complete as specified and as
directed by the Engineer-in-
Charge.
8.5.1 Polished Granite stone slab of all 220.00 sqm 3439.58 756708.00
colour and texture as approved by
Engineer-In-Charge.
8.6 Providing and laying Polished
Granite stone skirting, wall lining
in required design and patterns, in
linear as well as curvilinear
portions of the building, including
staircase risers with single-piece
granite stone all complete as per
the architectural drawings with 18
mm thick stone slab over 12 mm
thick bed of cement mortar 1:3 (1
Portland Pozzolana cement: 3
coarse sand) laid and jointed with
cement slurry and pointing with
white cement slurry admixed with
pigment of matching shade etc. all
complete as specified and as
directed by the Engineer-in-
Charge.
8.6.1 Polished Granite stone slab of all 35.00 sqm 3517.53 123114.00
colour and texture, as approved by
Engineer-In-Charge.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 284

Sl. No Description Quantity Unit Rate Amount


8.7 Providing and Laying European 890.00 sqm 5153.24 4586384.00
origin, Point Elastic Polyurethane
flooring system having thickness of
11mm comprising of 9mm
prefabricated SBR granulated mat
FIBA/BWF/IHF/FIVB certified
followed by 2mm PU coating,
seamless, non-porous and smooth
surface for very good resiliency for
comfort, injury prevention,
sustainability through high content
of recycled and renewable raw
materials in combination with
lasting performance through very
good mechanical strength, wear
resistance and easy maintenance,
repair & resurface procedures.
System consists of SBR matt laid
using two component PU adhesive
followed by sealer
to fill in all the voids of SBR mat, 2
coats of PU resin layer followed by
top PU coat and game line
marking. Product should meet
European standards EN-14904-P1
category, shock Absorption : 28%
as per EN 14808, Vertical
deformation : 1.4 mm as per En
14809, Friction value according to
EN 13036-4 should be on or above
107, Ball Bounce: 98 % according to
EN 12235, Gloss: 5 % as per
EN2813, Resistance to rolling Load
>_1500 N as per EN 1569,
Resistance to impact > 800 gr @
10°C & ≥ 1200 gr @ 23°C as per EN
1517, Resistance to
Indentation:0.35mm @ 5 min @
0.15mm @ 24 hrs. as per EN 1516,
Resistance to wear < 340 mg as per
EN ISO5470, Flammability: Bfi-S2
as per EN13501-1, Improvement
impact sound insulation (ΔLw):21
dB according to ISO 717-2, V.O.C.
content- adhesive/resins, Solvent
free, Resin Composition free of
solvents and heavy metals,

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 285

Sl. No Description Quantity Unit Rate Amount


Elongation at break: structure 150
% as per DIN 53455, Tensile
Strength: structure 8 N/mm2
according to DIN 53455, Tear
Strength: structure 25 N/mm2
according to DIN 53515.
Consumption of materials has been
as per standards which is 0.90
Kg/sqm Adhesive for SBR Matt,
0.5 Kg/sqm Sealer, 2.8 Kg/sqm PU
Wear Coating followed by 0.14
Kgsqm Top PU Colour Coat.
Product should be manufactured
under ISO 9001 for quality
management, ISO 14001 for
environmental care and ISO 26000
for corporate sustainability.
Note: All the materials/ products
have to be certified
FIBA/BWF/IHF/FIVB and are to
be approved by the Engineer in
charge before procurement by the
agency.
8.8 Providing & making of double 100.00 metre 513.41 51341.00
layer granite edge & forming of full
bull nose for Granite stone staircase
treads/ wall copings by using
50mm wide approved shade
granite stone slab strips and
fixing/ sand witching of same to
required granite stone treads/
coping edges by applying a thin
layer of mixture of equal amounts
of Araldite epoxy resin and
Hardener like adhesives on both
the bonding surfaces of granite
stone slab for double edge unique
formation and the outer shall be
moulded to full bull nose shape
including machine polishing to full
bullnose edge to give high gloss
finish etc. complete as per design
approved by Engineer-in-Charge.
(Fixing of finished treads/ copings
to be paid under respective original
granite flooring items).

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 286

Sl. No Description Quantity Unit Rate Amount


8.9 Providing full edge moulding to 200.00 metre 186.69 37338.00
skirting top/ nosing in treads of
steps of Kota Stone / Sand Stone /
Granite stone including machine
polishing to edge to give high gloss
finish etc., complete as per design
approved by Engineer-In-Charge.
8.10 Providing and fixing PVC corner 100.00 metre 54.77 5477.00
beading of size 10mm and of
matching shade at the protruding
corners of ceramic wall dado
complete all as directed by the
Engineer-in-charge
9 ROOFING
9.1 Extra for providing and fixing 280.00 metre 219.07 61340.00
wind ties of 40x 6 mm G.I. flat
section.
9.2 Making khurras 45x45 cm with 6.00 each 334.04 2004.00
average minimum thickness of 5
cm cement concrete 1:2:4 (1
Portland Pozzolana cement: 2
coarse sand: 4 graded stone
aggregate of 20 mm nominal size)
over P.V.C. sheet 1 m x1 m x 400
micron, finished with 12 mm
cement plaster 1:3 (1 Portland
Pozzolana cement: 3 coarse sand)
and a coat of neat cement,
rounding the edges and making
and finishing the outlet complete.
9.3 Providing and fixing on wall face
unplasticized Rigid PVC rain water
pipes conforming to IS: 13592 Type
A, including jointing with seal ring
conforming to IS: 5382, leaving 10
mm gap for thermal expansion, (i)
Single socketed pipes.
9.3.1 110 mm diameter 140.00 metre 422.69 59177.00
9.4 Providing and fixing on wall face
unplasticized-PVC moulded
fittings / accessories for
unplasticized Rigid PVC rain water
pipes conforming to IS: 13592 Type
A, including jointing with seal ring
conforming to IS: 5382, leaving 10
mm gap for thermal expansion.
9.4.1 Bend 87.5 degree
9.4.1.1 110 mm bend 6.00 each 168.39 1010.00
9.4.2 Shoe (Plain)
9.4.2.1 110 mm Shoe 6.00 each 147.67 886.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 287

Sl. No Description Quantity Unit Rate Amount


9.5 Providing and fixing unplasticised
-PVC pipe clips of approved design
to unplasticised - PVC rain water
pipes by means of 50x50x50 mm
hard wood plugs, screwed with
M.S. screws of required length,
including cutting brick work and
fixing in cement mortar 1:4 (1
Portland Pozzolana cement: 4
coarse sand) and making good the
wall etc. complete.
9.5.1 110 mm 70.00 each 415.86 29110.00
9.6 Providing and fixing to the inlet 6.00 each 94.70 568.00
mouth of rain water pipe PTMT (an
Engineering Thermoplastic) grating
square (Slit) 150 mm square with a
height of 8 mm and weighing not
less than 100 gms.
9.7 Providing and fixing false ceiling at
all heights with integral densified
calcium silicate reinforced with
fibre and natural filler false ceiling
tiles of Size 595x595 mm of
approved texture, design and
patterns having NRC (Noise
Reduction coefficient) of 0.50
(minimum) as per IS 8225:1987,
Light reflectance of 85%
(minimum). Non-combustible as
per BS:476 (part-4), fire
performance as per BS:476 (part 6
&7), humidity resistance of 100%,
thermal conductivity < 0.043 W/m
K as per ASTM 518:1991, in true
horizontal level suspended on
interlocking metal powder coated
T-Grid of hot dipped galvanised
iron section of 0.40 mm thick on
Silhouette profile, rotary stitched
double webbed white with 6mm
reveal profile ( white / black),
comprising of main-T runners of
size 15x42mm of length 3000 mm,
cross - T of size 15x42 mm of length
1200 mm and secondary
intermediate crossT of size 15x42
mm of length 600mm to form grid
module of size 600 x 600 mm,
suspended from ceiling using
galvanised mild steel items
(galvanizing @ 80 grams per sqm)
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 288

Sl. No Description Quantity Unit Rate Amount


i.e. 50 mm long, 8 mm outer
diameter M-6 dash fasteners,
6 mm dia fully threaded hanger
rod up to 1000 mm length and L-
shape level adjuster of size
85x25x2mm. Galvanised iron
perimeter wall angle of size
22x19x0.40 mm of length 3000 mm
to be fixed on periphery wall /
partition with the help of plastic
rawl plugs at 450 mm centre to
centre and 40mm long dry wall S.S
screws. The work shall be carried
out as per specifications, drawing
and as per directions of the
Engineer-in-Charge.
9.7.1 With 15 mm thick integral 360.00 sqm 2946.05 1060578.00
densified micro edge light weight
calcium silicate false ceiling tiles
9.8 Providing and fixing 50mm thick 900.00 sqm 2666.36 2399724.00
Continuous Line Factory Insulated
PUF Panel precoated galvanised
iron profile (GLAMET or
equivalent) sheets (size, shape and
pitch of corrugation as approved
by Engineer-in-charge) with
External steel sheet of 0.50 mm
thick (TCT) PPGL, external coating
in RMP and colour in RAL 9002,
crest height 38mm spaced at
333mm intervals, three baby ribs in
between the 1 valley. Insulation
with CFC/HCFC Free [ ZERO
ODP] PUR [ CP BLOWN] [ IS
12436, B3/ EN14509], Density 40+2
kg/m3, Internal steel sheet of 0.50
mm thick (TCT) PPGL external
coating in RMP and external colour
in RAL 9002, micro ribs spaced at
62.5mm intervals. supply width of
the panel will be 1060 mm,
thickness of the panel 50+2mm.
Sheet should have protective guard
film of 25 microns minimum to
avoid scratches during
transportation. The sheet shall be
fixed using self-drilling /self-
tapping screws of size (8 x 100 mm)
with EPDM seal, complete upto
any pitch in horizontal/ vertical
surfaces, excluding the cost of
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 289

Sl. No Description Quantity Unit Rate Amount


accessories like ridges, gutters and
purlins, rafters and trusses and
including cutting to size and shape
wherever required and
transportation etc. all complete as
directed by the Engineer-In-
Charge.
9.9 Providing and fixing precoated
galvanised steel sheet roofing
accessories of total coated thickness
0.50mm (base metal of minimum
0.45 mm thickness with total
coating thickness of 0.05mm) with
Zinc coating 120 grams per sqm as
per IS: 277, in 240 mpa steel grade,
5-7 microns epoxy primer on both
side of the sheet and polyester top
coat 15-18 microns using self-
drilling/ self-tapping screws
complete
9.9.1 Profile Ridges suitable to roofing at 35.00 metre 504.67 17663.00
item no. 9.8 above.
9.9.2 Gutter (Not less than 600 mm over 70.00 metre 1243.87 87071.00
all girth).
9.10 Providing and fixing factory made 15.00 sqm 3849.61 57744.00
18 mm thick single extruded WPC
(Wood Polymer Composite) solid
plain white colour board Jali, CNC
(Computer numeric control) routed
of approved design by Engineer-in
-charge which are machine cut for
duct/shaft covering, partitions and
facades comprising of virgin
polymer of K value 58-60
(Suspension Grade), calcium
carbonate and natural fibers (wood
powder/ rice husk/wheat husk)
and nontoxic additives(maximum
toxicity index of 12 for 100 gms)
having minimum density of 650
kg/cum and screw withdrawal
strength of 1800 N (Face) minimum
compressive strength 50 N/mm2,
modulus of elasticity 850 N/mm2
and resistance to spread of flame of
Class A category with properties of
being termite/borer proof,
water/moisture proof and fire
retardant and fixing on M.S (mild
steel) frame made of 25 x 25 x 1.5
mm square hollow box section
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 290

Sl. No Description Quantity Unit Rate Amount


including applying a priming coat
of approved steel primer, placed at
grid made at 1.0 x 1.0 m or as per
requirement at site with necessary
stainless steel fasteners and SS
screws etc., all complete as per
direction of Engineer-In- Charge.
(Note: M.S (mild steel) framework
with priming coat and necessary SS
fasteners and SS screws shall be
paid separately.
10 FINISHING
10.1 12 mm cement plaster of mix
including mixing of synthetic
polyester triangular fibre of length
6mm, effective diameter 10-40
microns and specific gravity 1.34 to
1.40 in cement plaster / mortar by
using 125 grams of synthetic
polyester triangular fibre for 50 kgs
cement used in cement mortar as
per direction of Engineer-in-
charge.:
10.1.1 1:6 (1 Portland Pozzolana cement: 6 1650.00 sqm 373.35 616028.00
fine sand)
10.2 15 mm cement plaster on the rough
side of single or half brick wall of
mix including mixing of synthetic
polyester triangular fibre of length
6mm, effective diameter 10-40
microns and specific gravity 1.34 to
1.40 in cement plaster / mortar by
using 125 grams of synthetic
polyester triangular fibre for 50 kgs
cement used in cement mortar as
per direction of Engineer-in-
charge.:
10.2.1 1:6 (1 Portland Pozzolana cement: 6 1400.00 sqm 428.96 600544.00
fine sand)
10.3 6 mm cement plaster of mix:
10.3.1 1:3 (1 Portland Pozzolana cement: 3 950.00 sqm 336.50 319675.00
fine sand)
10.4 Extra for plastering exterior walls 120.00 sqm 97.55 11706.00
of height more than 10 m from
ground level for every additional
height of 3 m or part thereof.
10.5 Finishing walls with Premium
Acrylic Smooth exterior paint with
Silicone additives of required
shade

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 291

Sl. No Description Quantity Unit Rate Amount


10.5.1 New work (Two or more coats 2400.00 sqm 147.06 352944.00
applied @ 1.43 ltr/ 10 sqm) over
putty surface.
10.6 Painting with synthetic enamel
paint of approved brand and
manufacture to give an even shade:
10.6.1 Two coats or more coats on new 400.00 sqm 174.61 69844.00
work
10.7 Providing and applying white 3950.00 sqm 174.78 690381.00
cement based water proof wall
putty in two coats to a thickness of
1.0mm (total thickness) over
cement plastered wall surface to
make it even and smooth using
water proof wall care putty of
approved brand / manufacturer all
complete (The rate quoted is
inclusive of all operations of
removal of dust, dirt and foreign
matter etc., before applying the
putty and curing the applied
surface with water for sufficient
days after the application of the
putty and preparing the dried
surface with fine emery paper fit to
receive the paint) Note: No primer
is to be applied on the surface of
the putty. The acrylic emulsion
paint shall be applied directly
over the surface.
10.8 Wall painting with premium
acrylic emulsion paint of interior
grade, having VOC (Volatile
Organic Compound) content less
than 50 grams/ litre of approved
brand and manufacture, including
applying additional coats wherever
required to achieve even shade and
colour.
10.8.1 Two or more coats on new work. 3400.00 sqm 159.94 543796.00
10.9 Polishing in high gloss/matt finish 25.00 sqm 1523.70 38093.00
melamine clear polish on wood
work in required colour/wooden
shade texture with following
process in the sequence as detailed
below:
The surface to be polished is
rubbed with sand paper 80/ 120
no. and then with sand paper of
160/180 nos. Applying two coats of
sealer with spray gun and allowing
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 292

Sl. No Description Quantity Unit Rate Amount


sufficient drying time for 1st coat
and 2nd coat is allowed to dry for 8
to 12 hrs.

On drying of sealer coat, wet


rubbing with emery cloth of finer
grading with ample water to
remove excess sealer layer and
make the surface further smooth
after this wet rubbing, then
surface is applied with special
grade melamine fillers to fill all
the small and big holes/grooves
etc. Filler coat to be allowed to
dry for 4 to 6 hrs. on which again
a light wet rubbing is done this
surface is further allowed to dry
for 12 hrs.

On this, 1st coat of melamine


polish is applied with spray gun
using melamine clear polish and
melamine thinner in required
proportion. This 1st coat is
allowed to dry for 24 hrs. then
this dry surface is again fine wet
rubbed smooth, which is further
allowed to dry for 12 hrs. The
final melamine polish is applied
with compressor pressure spray
gun using melamine clear polish
and melamine thinner mixed in
required proportion complete as
per direction of Engineer-in-
Charge. (Final coat to be done in 1
or 2 layers without gap of time.)

10.10 Providing and fixing 200 mm 300.00 metre 34.22 10265.00


wide diamond shaped rabbit wire
mesh of gauge 28 with nails at the
joints and brick wall and RCC
Columns, beams etc. and at the
electrical conduits as
reinforcement before cement
plastering etc. complete as per the
directions of Engineering in
charge.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 293

Sl. No Description Quantity Unit Rate Amount


11 ROAD WORK
11.1 Preparation and consolidation of 220.00 sqm 245.17 53937.00
sub grade with vibromax road
roller of 8 to 12 tonne capacity after
excavating earth to an average of
22.5 cm. depth, dressing to camber
and consolidating with road roller
including making good the
undulations etc. and re-rolling the
sub grade and disposal of surplus
earth for all leads within the
campus as directed by Engineer-In-
Charge.
11.2 Providing and laying design mix
cement concrete of M-40 grade, in
roads/ taxi tracks/ runways, using
cement content as per design mix,
using coarse sand and graded stone
aggregate of 20 mm nominal size in
appropriate proportions as per
approved & specified design
criteria, providing dowel bars with
sleeve/ tie bars wherever required,
laying at site, spreading and
compacting mechanically by using
needle and surface vibrators,
levelling to required slope/
camber, finishing with required
texture, including steel form work
with sturdy M.S. channel sections,
curing, making provision for
contraction/ expansion,
construction & longitudinal joints
(10 mm wide x 50 mm deep) by
groove cutting machine, providing
and filling joints with approved
joint filler and sealants, complete
all as per direction of Engineer-in-
charge (Item of joint fillers,
sealants, dowel bars with sleeve/
tie bars to be paid separately).
Note:-
1) Cement content considered in
M-40 is @ 390 kg/cum.
2). Excess/less cement used as per
design mix is payable/ recoverable
separately.
3). Extra cement up to 10% of the
minimum specified cement content
in design mix shall be payable
separately. In case the cement
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 294

Sl. No Description Quantity Unit Rate Amount


content in design mix is more than
110% of the specified minimum
cement content, the contractor shall
have discretion to either re-design
the mix or bear the cost of extra
cement. 4) water cement ratio shall
not exceed 0.40
11.2.1 Cement concrete prepared with 35.00 cum 12203.63 427127.00
batch mixing machine.
Note: If the agency wants to
procure the concrete from the RMC
plant, they can procure with prior
approval of the design mix and
RMC plant from the Engineer in
charge. No additional clams will be
admissible in this regard.
11.3 Providing and filling in position
rubberized bitumen hot sealing
compound for sealing of expansion
joints in roads / pavements all
complete as per direction of the
Engineer-in-Charge.
11.3.1 Using grade 'A' sealing compound 1000.00 per cm 9.69 9690.00
conforming to IS: 1834 depth
per Cm
width
per
metre
length
11.4 Providing and fixing 500mm long 500.00 kg 196.77 98385.00
MS 25mm dia plain bars at
expansion Joints in Cement
Concrete Roads along with 300mm
length 32mm PVC pipe sleeve for
one side of Joint with cap etc.,
complete as per the direction of
Engineer in Charge.
11.5 Providing and laying C.C. Flooring 50.00 cum 11002.66 550133.00
of required thickness with M-25
grade ready mixed concrete from
batching plant. The ready mixed
concrete shall be laid and finished
with screed board vibrator,
vacuum dewatering process and
finally finished by floating,
brooming with wire brush etc.
complete as per specifications and
directions of Engineer-in-charge.
(The panel shuttering work shall be
paid for separately).

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 295

Sl. No Description Quantity Unit Rate Amount


(Note:-
1. Cement content considered
in this item is @ 330
kg/cum.
2. Excess/less cement used
as per design mix is
payable/ recoverable
separately).
3. Extra cement up to 10%
of the minimum specified
cement content in design
mix shall be payable
separately. In case the
cement content in design
mix is more than 110% of
the specified minimum
cement content, the
contractor shall have
discretion to either re-
design the mix or bear the
cost of extra cement.
11.6 Providing and laying Dry Lean 35.00 cum 5057.25 177004.00
Cement Concrete Sub-base as per
IRC:SP-49 (Construction of dry lean
cement concrete base course over a
prepared sub-base) with coarse and
fine aggregate conforming to IS:
383, the size of coarse aggregate not
exceeding 25 mm, aggregate
cement ratio not to exceed 15:1,
aggregate gradation after blending
to be as per table 600-1, Ordinary
Portland cement content not to be
less than 200 kg/cum, optimum
moisture content to be determined
during trial length construction,
concrete strength not to be less than
15 Mpa at 7 days, mixed in a
batching plant, transported to site,
laid with a paver, compacting with
8-10 tonnes vibratory roller,
finishing the top surface even and
smooth and curing for required
no. of days all complete as per
direction of Engineer-in-Charge)
Note: Nothing extra shall be paid if
any excess cement is required in
the mix as per mix design such
excess cementitious materials can
be met from GGBS

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 296

Sl. No Description Quantity Unit Rate Amount


12 SANITARY INSTALLATIONS
12.1 Providing and fixing white 8.00 each 11005.52 88044.00
vitreous China pedestal type water
closet (European type W.C. pan) of
Parry ware - Petite - C0288 or
equivalent with seat and lid, C P
Brass Flush Valve Dual Flow 32mm
Size (Concealed Body) With
Exposed Shut Off Provision &
100mm Square Plate of Jaquar -
Metropole series - FLV-1085NSQ or
equivalent including flush pipe,
with all fittings and fixtures
complete, including cutting and
making good the walls and floors
wherever required : - W.C. pan of
size 520 x 360 x 405 mm with ISI
marked white solid plastic seat and
lid
12.2 Providing and fixing white 3.00 each 15678.71 47036.00
vitreous China flat back half stall
urinal of size 340x325x650 mm of
Jaquar make URS-WHT-13253N
with Urinal Valve Auto Closing
System with Built-in Control Cock
& Wall Flange of jaguar make PRS-
CHR-073 with fittings, spreaders
with unions and clamps (all in C.P.
brass) with waste fitting as per IS :
2556, C.I. trap with outlet grating
and other couplings in C.P. brass,
including painting of fittings and
cutting and making good the walls
and floors wherever required :
12.3 Providing and fixing wash basin 7.00 each 8454.25 59180.00
with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass
waste of standard pattern,
including painting of fittings and
brackets, cutting and making good
the walls wherever required:
Star White Vitreous China Under
counter Wash basin of size
605x410x200 mm as per model No.
FNS-WHT-40701 of Jaquar or its
equivalent of rectangular shape
with a single C.P. Brass long neck
Pillar cock of approved make and
colour as per Model No: CON-
021KN of Jaquar or equivalent
make.
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 297

Sl. No Description Quantity Unit Rate Amount


12.4 Providing and fixing CP Brass 11.00 each 1158.98 12749.00
32mm size Bottle Trap of approved
quality & make and as per the
direction of Engineer-in-charge.
12.5 Providing and fixing CP Brass 2.00 each 7773.64 15547.00
Single lever telephonic wall mixer
of quality & make as approved by
Engineer in charge.
(a) 15 mm nominal dia
12.6 Providing and fixing 6 mm thick
mirror of superior glass (of
approved quality) and of required
shape and size with rigid PVC
decorative moulded frame of
approved make and shade with 6
mm thick hard board backing:
12.6.1 Rectangular shape of required size 3.00 sqm 3472.83 10418.00
12.7 Providing and fixing unplasticized
Rigid PVC SWR single socketed
pipes conforming to IS 13592 Type B
(pressure of 6 kg/sqcm) including
jointing with seal ring conforming to
IS: 5382 leaving 10mm gap for
thermal expansion and jointing with
approved solvent wherever required
as per the direction of the Engineer-
in-charge for soil, waste and vent
pipes including necessary fittings
and accessories complete.(Note: 1.
All the joints shall be leak proof. 2.
The centre line length of pipes shall
be measured for the purpose of
payment. 3. Floor trap and terminal
guard only shall be measured
separately for payment).
12.7.1 110 mm dia. 120.00 metre 780.60 93672.00
12.7.2 50 mm dia 10.00 metre 231.63 2316.00
12.8 Providing and fixing unplasticized
Rigid PVC fittings and specials
conforming to IS 13592 Type-B
(pressure of 6 kg/sqcm) including
jointing with seal ring conforming to
IS: 5382 leaving 10mm gap for
thermal expansion and jointing with
approved solvent wherever required
as per the direction of the Engineer-
in-charge for soil, waste and vent
pipes. - Providing and fixing
unplasticized PVC terminal guard:
(Note: All the joints shall be leak
proof.).
12.8.1 110 mm 5.00 each 147.30 737.00
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 298

Sl. No Description Quantity Unit Rate Amount


12.9 Providing and fixing unplasticized 7.00 each 212.37 1487.00
Rigid PVC floor trap of self-
cleansing design with screwed
down or hinged grating with or
without vent arm complete,
including cost of cutting and
making good the walls and floors:
100 mm inlet and 100 mm outlet
12.10 Providing and fixing GI clamps of 30.00 each 185.65 5570.00
approved design for fixing vertical
stacks of Water supply, Sanitary
and Rainwater pipelines, with
suitable screws, etc complete as per
directions of Engineer - in Charge: -
For 110mm dia pipes
13 WATER SUPPLY
13.1 Providing and fixing Chlorinated
Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot &
cold-water supply, including all
CPVC plain & brass threaded
fittings including fixing the pipe
with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings
with one step CPVC solvent
cement and testing of joints
complete as per direction of
Engineer-in-Charge. Internal work
- Exposed on wall
13.1.1 32mm nominal dia pipes 20.00 metre 581.00 11620.00
13.1.2 40 mm nominal dia pipes 50.00 metre 787.30 39365.00
13.2 Providing and fixing Chlorinated
Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot &
cold-water supply, including all
CPVC plain & brass threaded
fittings i/c fixing the pipe with
clamps at 1.00 m spacing. This
includes jointing of pipes & fittings,
with one step CPVC solvent
cement and the cost of cutting
chases and making good the same
including testing of joints complete
as per direction of Engineer-in-
Charge. Concealed work, including
cutting chases and making good
the wall etc.
13.2.1 20 mm nominal dia pipes 20.00 metre 602.11 12042.00
13.2.2 25 mm nominal dia pipes 30.00 metre 702.52 21076.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 299

Sl. No Description Quantity Unit Rate Amount


13.3 Providing and fixing Chlorinated
Polyvinyl Chloride (CPVC) Ball
valve (union type)/gate valve of
approved quality (screwed end):
13.3.1 32 mm nominal bore 5.00 each 736.08 3680.00
13.3.2 40 mm nominal bore 5.00 each 1111.56 5558.00
13.4 Providing and fixing C.P. brass
long body bib cock of approved
quality conforming to IS standards
and weighing not less than 690
gms.
13.4.1 15 mm nominal bore 2.00 each 894.82 1790.00
13.5 Providing and fixing C.P. brass
angle valve for basin mixer and
geyser points of approved quality
conforming to IS:8931
13.5.1 15 mm nominal bore 14.00 each 643.22 9005.00
13.6 Providing and fixing Stainless steel 15.00 each 220.58 3309.00
grating of approved quality and
colour. - Rectangular type with
openable circular lid - 150 mm
nominal size square 100 mm
diameter of the inner hinged round
grating
13.7 Providing and fixing PTMT Ball
cock of approved quality, colour
and make complete with Epoxy
coated aluminium rod with L.P. /
H.P.H.D. plastic ball.
13.7.1 25 mm nominal bore, 152 mm long, 1.00 each 586.66 587.00
weighing not less than 440 gms
13.8 Providing and fixing unplasticized
P.V.C. connection pipe with PTMT
Nuts, collar and bush of approved
quality and colour.
13.8.1 15 mm nominal bore with 45 cm 14.00 each 136.53 1911.00
length
13.9 Providing and fixing C.P brass 8.00 each 2198.44 17588.00
two-way bib cock with wall flange
of Lyric range of Jaguar Make Code
No. LYR-CHR-38041 or its
equivalent as per the direction of
Engineer-in-charge. - 15 mm
nominal bore
13.10 Providing and fixing C.P brass 8.00 each 1246.16 9969.00
Health faucet ALD-CHR-565,
CP brass Hand Shower Hand
Shower (Health Faucet) with 1.0-
Meter-Long easy flex tube in
chrome finish & Wall Hook of
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 300

Sl. No Description Quantity Unit Rate Amount


jaguar make complete as per the
direction of Engineer-in-charge.
13.11 Providing and fixing Toilet paper 8.00 each 848.56 6788.00
roll holder with flap of JAQUAR
make or equivalent as per direction
of Engineer in charge.
13.12 Providing and fixing Double coat 15.00 each 647.05 9706.00
hook Code: ACN-CHR-1161N
jaguar make complete as per the
direction of Engineer-in-charge.
13.13 Providing and fixing CP Brass 2.00 each 1489.27 2979.00
liquid soap dispenser & wall flange
of Model: ACN-CHR-1135N of
Jaquar or equivalent make and as
per the direction of Engineer-in-
charge.
13.14 Providing and fixing CP Brass 4.00 each 1104.09 4416.00
towel ring of 178mm outer dia and
55mm distance from wall surface &
wall flange of Model: ACN-CHR-
1121BN of Jaquar or equivalent
make and as per the direction of
Engineer-in-charge.
13.15 Providing and fixing CP Brass 2.00 each 3629.87 7260.00
towel rack 600mm long with lower
hanger (Code: ACN-CHR-1181S) of
Jaquar or equivalent make and as
per the direction of Engineer-in-
charge.
13.16 Providing and fixing Overhead 2.00 each 3296.49 6593.00
Shower 120mm Round Shape
Single Flow (ABS Body Chrome
Plated with Grey Face Plate) with
Rubit Cleaning System of Jaquar or
equivalent make with Shower arm
casted 160mm long light body
round shape for wall mounted
showers with flange (Code: SHA-
CHR-477), of Jaquar or equivalent
make complete as per the direction
of Engineer-in-charge.
14 DRAINAGE
14.1 Providing and fixing square-mouth
S.W. gully trap class SP-1 complete
with C.I. grating brick masonry
chamber with water tight C.I. cover
with frame of 300 x300 mm size
(inside) the weight of over to be not
less than 4.50 kg and frame to be
not less than 2.70 kg as per
standard design
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 301

Sl. No Description Quantity Unit Rate Amount


14.1.1 150 x 100 mm size P type
14.1.1.1 With common burnt clay F.P.S. 5.00 each 3062.30 15312.00
(non modular) bricks of class
designation 5.0 insides plastering
and making channels to be
executed as per CPWD
Specifications and external
plastering to be of 15mm thick
Cement mortar 1:3 (1 cement: 3
coarse sand)
14.2 Providing and laying non-pressure
NP2 class (light duty) R.C.C. pipes
with collars jointed with stiff
mixture of cement mortar in the
proportion of 1:2 (1 cement: 2 fine
sand) including testing of joints etc.
complete:
14.2.1 150 mm dia. R.C.C. pipe 60.00 metre 623.22 37393.00
14.2.2 250 mm dia. R.C.C. pipe 150.00 metre 1007.78 151167.00
14.3 Constructing brick masonry
manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) with R.C.C.
top slab with 1:1.5:3 mix (1 cement :
1.5 coarse sand (zone-III) : 3 graded
stone aggregate 20 mm nominal
size), foundation concrete 1:4:8 mix
(1 cement : 4 coarse sand (zone-III) :
8 graded stone aggregate 40 mm
nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished
with floating coat of neat cement
and making channels in cement
concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20
mm nominal size) finished with a
floating coat of neat cement and
external plastering 15mm thick
with cement mortar (1 cement : 3
coarse sand) complete as per
standard design
14.3.1 Inside size 90x80 cm and 45 cm
deep including precast RCC
manhole cover with frame L.D.-2.5,
rectangular shape 600X450 mm
internal dimensions
14.3.1.1 With common burnt clay F.P.S. 7.00 each 13033.10 91232.00
(non modular) bricks of class
designation 5.0
14.4 Extra for depth for manholes

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 302

Sl. No Description Quantity Unit Rate Amount


14.4.1 Size 90x80 cm

14.4.1.1 With common burnt clay F.P.S. 2.00 metre 9884.45 19769.00
(non modular) bricks of class
designation 5.0
14.5 Providing orange colour safety 20.00 each 620.14 12403.00
foot rest of minimum 6 mm thick
plastic encapsulated as per IS :
10910, on 12 mm dia steel bar
conforming to IS: 1786, having
minimum cross section as 23
mmx25 mm and over all
minimum length 263 mm and
width as 165 mm with minimum
112 mm space between protruded
legs having 2 mm tread on top
surface by ribbing or chequering
besides necessary and adequate
anchoring projections on tail
length on 138 mm as per standard
drawing and suitable to with
stand the bend test and chemical
resistance test as per
specifications and having
manufacture's permanent
identification mark to be visible
even after fixing, including fixing
in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1
cement : 3 coarse sand : 6 graded
stone aggregate 20 mm nominal
size) complete as per design.

14.6 Providing and fixing in position


SFRC Cover and frame
conforming to I.S. 12592 to of
required shape and approved
quality

14.6.1 L D- 2.5

14.6.1.1 Rectangular shape 600x450 mm 4.00 each 1610.17 6441.00


internal dimensions

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 303

Sl. No Description Quantity Unit Rate Amount


15 ALUMINIUM WORK
15.1 Providing and fixing aluminium
work for doors, windows,
ventilators and partitions with
extruded built up standard tubular
sections/ appropriate Z sections
and other sections of approved
make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of
required dia and size, including
necessary filling up the gaps at
junctions, i.e., at top, bottom and
sides with required EPDM rubber/
neoprene gasket etc. Aluminium
sections shall be smooth, rust free,
straight, mitred and jointed
mechanically wherever required
including cleat angle, Aluminium
snap beading for glazing /
panelling, C.P. brass / stainless
steel screws, all complete as per
architectural drawings and the
directions of Engineer-in-charge.
(Glazing, panelling and dash
fasteners to be paid for separately):
15.1.1 For fixed portion
15.1.1.1 Powder coated aluminium 50.00 kg 594.61 29731.00
(minimum thickness of powder
coating 50 micron)
15.1.2 For shutters of doors, windows &
ventilators including providing
and fixing hinges/ pivots and
making provision for fixing of
fittings wherever required
including the cost of EPDM rubber
/ neoprene gasket required
(Fittings shall be paid for
separately)
15.1.2.1 Powder coated aluminium 30.00 kg 710.58 21317.00
(minimum thickness of powder
coating 50 micron)
15.3 Providing and fixing 18 mm thick 25.00 sqm 1473.44 36836.00
both sides pre-laminated cement
bonded wood particle board as per
IS: 15786:2008, in panelling fixed in
aluminium doors, windows shutters
and partition frames with C.P. brass
/ stainless steel screws etc. complete
as per architectural drawings and
directions of engineer-in-charge.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 304

Sl. No Description Quantity Unit Rate Amount


16 WATERPROOFING
16.1 Providing and laying water 200.00 sqm 1216.16 243232.00
proofing treatment to sunken floors
and inner surfaces of overhead
water tank, sump tank etc. by
applying:
(i) First coat of Brush bond RFX @
DFT 1mm thick of M/S Fosroc
chemicals or equivalent as per
manufacture's specification. This
coat is to be air curved for 6 hours.
(ii) Second coat of brush bond RFX
@ DFT 1mm thick of Fosroc
chemicals or equivalent as per
manufacture's specification. This
coat is to be air cured for 6 hours.
(iii)Third coat of bond coat with
cement slurry mixed with SBR
latex @ 3 litres per bag of cement
applied as per manufactures
specification to get good bonding
with next layer.
(iv) Fourth coat of 12mm thick
cement plaster in cement mortar 1:3
(1 Portland Pozzolana cement: 3
fine sand) with floating coat of neat
cement punning both admixed
with conplast WL of Fosroc of Pidi
proof 101 LW of pidilite or
equivalent applied before the air
curing of third layer. The rate
includes preparation of surface
treatment, removal of dust from
surface using compressed air and
sealing of all joints, corners,
junctions of pipes and RCC with
polymet mixed slurry etc. all
complete as per direction of
Engineer in charge.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 305

Sl. No Description Quantity Unit Rate Amount


16.2 Providing and laying integral
cement based water proofing
treatment including preparation of
surface as required for treatment of
roofs, balconies, terraces etc.
consisting of following operations:
(a) Applying a slurry coat of neat
cement using 2.75 kg/sqm of
cement admixed with water
proofing compound conforming to
IS. 2645 and approved by Engineer-
in-charge over the RCC slab
including adjoining walls up to 300
mm height including cleaning the
surface before treatment.
(b) Laying brick bats with mortar
using broken bricks/brick bats 25
mm to 115 mm size with 50% of
cement mortar 1:5 (1 cement : 5
coarse sand) admixed with water
proofing compound conforming to
IS : 2645 and approved by Engineer
in- charge over 20 mm thick layer
of cement mortar of mix 1:5 (1
cement :5 coarse sand ) admixed
with water proofing compound
conforming to IS : 2645 and
approved by Engineer in- charge to
required slope and treating
similarly the adjoining walls up to
300 mm height including rounding
of junctions of walls and slabs.
(c) After two days of proper curing
applying a second coat of cement
slurry using 2.75 kg/ sqm of
cement admixed with water
proofing compound conforming to
IS : 2645 and approved by
Engineer-in-charge.(d) Finishing
the surface with 20 mm thick joint
less cement mortar of mix 1:4 (1
cement :4 coarse sand) admixed
with water proofing compound
conforming to IS : 2645 and
approved by Engineer-in-charge
including laying glass fibre cloth of
approved quality in top layer of
plaster and finally finishing the
surface with trowel with neat
cement slurry and making pattern
of 300x300 mm square 3 mm deep.
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 306

Sl. No Description Quantity Unit Rate Amount


(e) The whole terrace so finished
shall be flooded with water for a
minimum period of two weeks for
curing and for final test. “All above
operations to be done in order and
as directed and specified by the
Engineer-in-Charge:
16.2.1 With average thickness of 120 mm 995.00 sqm 1886.75 1877316.00
and minimum thickness at khurra
as 65 mm.
16.3 Providing and applying of 71.00 metre 642.26 45600.00
swellable type water stop tape,
19mm x 25mm thick in linear meter
(expansive nature) for construction
joints treatment of RCC structure
such as raft slab, retaining walls,
water storage tank and at the
junctions of raft slab with the
retaining walls etc. After cleaning
the surface, one coat of required
primer for swellable water stop
tape shall be applied throughout
the length of the joint @3.78 litre
per 240 running meters. Over the
primed surface swellable type
water stop tape shall be placed. The
work shall be carried out all
complete as per specification and
the direction of the Engineer-In-
Charge. The product performance
shall carry guarantee for 10 years
against any leakage.

Total 56868888.00

Contractor Executive Engineer

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 307

Electrical Component

S.No. Description Qty Unit Rate Amount


C1: 1. IEI & Fans, Split ACs, LT Panels &
cables and earthing
Sub Head-I (Wiring)
1 Wiring for light point/ fan point/ exhaust
fan point/ call bell point with 1.5 sq.mm
FRLS PVC insulated copper conductor
single core cable in surface / recessed
medium class PVC conduit, with modular
switch, modular plate, suitable GI box and
earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single
core cable etc. Complete as required.
1.1 Group C
189 Point 1559.86 294814.00
2 Wiring for twin control light point with 1.5
sq.mm FRLS PVC insulated copper
conductor single core cable in surface /
recessed medium class PVC conduit, 2-way
modular switch, modular plate, suitable GI
box and earthing the point with 1.5 sq.mm
FRLS PVC insulated copper conductor
single core cable etc. as required. 8 Point 1660.87 13287.00
3 Wiring for group controlled (looped) light
point/fan point/exhaust fan point/ call
bell point (without independent switch
etc.) with 1.5 sq. mm FRLS PVC insulated
copper conductor single core cable in
surface/ recessed PVC conduit, and
earthing the point with 1.5 sq. mm FRLS
PVC insulated copper conductor single
core cable etc. as required.
3.1 Group C
1 Point 912.31 912.00
4 Wiring for light/ power plug with 2X4 sq.
mm FRLS PVC insulated copper conductor
single core cable in surface/ recessed
medium class PVC conduit along with 1
No. 4 sq. mm FRLS PVC insulated copper
conductor single core cable for loop
earthing as required. 600 Meter 355.14 213084.00
5 Wiring for light/ power plug with 4X4 sq.
mm FRLS PVC insulated copper conductor
single core cable in surface/ recessed
medium class PVC conduit along with 2
Nos. 4 sq. mm FRLS PVC insulated copper
conductor single core cable for loop
earthing as required. 200 Meter 570.99 114198.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 308

S.No. Description Qty Unit Rate Amount


6 Wiring for circuit/ submain wiring along
with earth wire with the following sizes of
FRLS PVC insulated copper conductor,
single core cable in surface/ recessed
medium class PVC conduit as required.
6.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 260 Meter 247.75 64415.00
6.2 4 x 6 sq. mm + 2 X 6 sq. mm earth wire 80 Meter 801.73 64138.00
6.3 4 x 10 sq. mm + 2 X 6 sq. mm earth wire 50 Meter 1068.62 53431.00
6.4 4 x 16 sq. mm + 2 X 6 sq. mm earth wire 30 Meter 1451.40 43542.00
7 Supplying and drawing following sizes of
FRLS PVC insulated copper conductor,
single core cable in the existing surface/
recessed steel/ PVC conduit as required.
7.1 6 X 1.5 Sq.mm 90 Meter 192.46 17321.00
8 Supplying and fixing of following sizes of
medium class PVC conduit along with
accessories in surface/recess including
cutting the wall and making good the same
in case of recessed conduit as required.
8.1 20mm 50 Meter 136.10 6805.00
8.2 25mm 800 Meter 154.18 123344.00
8.3 32mm 130 Meter 195.65 25435.00
9 Supply and fixing of following UPVC cable
management system with accessories etc.,
9.1 100 mm x 50 mm U-PVC cable
management system of polycarbonate,
channel base, front cover and separation
partition including accessories, suitable on
surface etc. as required 50 Meter 1700.16 85008.00
10 Supplying and fixing following modular
switch/ socket on the existing modular
plate & switch box including connections
but excluding modular plate etc. as
required.
10.1 Telephone socket outlet 9 Each 157.37 1416.00
10.2 TV antenna socket outlet 7 Each 157.37 1102.00
10.3 CAT6A socket outlet 7 Each 715.05 5005.00
11 Supplying and fixing following
size/modules GI box along with modular
base & cover plate for modular switches on
recess etc as required.
11.1 1 or 2 Module (75mmX75mm) 23 Each 316.86 7288.00
12 Supplying and fixing modular blanking
plate on the existing modular plate &
switch box excluding modular plate as
required. 25 Each 42.53 1063.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 309

S.No. Description Qty Unit Rate Amount


13 Supplying and fixing suitable size GI box
with modular plate and cover in front on
surface or in recess, including providing
and fixing 2 nos. 3 pin 5/6 A modular
socket outlet and 2 nos. 5/6 A modular
switch, connections etc. as required. (For
light plugs to be used in non-residential
buildings). 41 Each 718.79 29470.00
14 Supplying and fixing suitable size GI box
with modular plate and cover in front on
surface or in recess, including providing
and fixing 6 pin 5/6 & 15/16 A modular
socket outlet and 15/16 A modular switch,
connections etc. as required. 26 Each 623.09 16200.00
15 Supplying & fixing suitable size GI box
with modular plate and cover in front on
surface or in recess including providing
and fixing 25 A modular socket outlet and
25 A modular SP MCB, "C" curve including
connections, painting etc. as required. 12 Each 773.02 9276.00
16 Supplying and fixing two module stepped
type electronic fan regulator on the existing
modular plate switch box including
connections but excluding modular plate
etc. as required. 23 Each 392.36 9024.00
17 Supplying, installation, testing and
commissioning of Passive Infrared (PIR)
technology based occupancy sensor having
high performance, non-regulating
programmable type, suitable for connected
load up to 10Amp , for mounting height up
to 2.8 mtr and for 5 m diameter coverage
area along with necessary fixing
arrangements i/c programming at site etc.
complete as required.
2 Each 4893.31 9787.00
18 Supplying and drawing following pair 0.5
mm dia FR PVC insulated annealed copper
conductor, unarmored telephone cable in
the existing surface/ recessed steel/ PVC
conduit as required.
18.1 2 Pair 200 Mtrs 40.41 8082.00
19 Supplying and drawing following pair 0.5
mm dia FR PVC insulated annealed copper
conductor, armored telephone cable in the
existing surface/ recessed steel/ PVC
conduit/DWC pipe as required.
19.1 20 Pair 400 Mtrs 141.09 56436.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 310

S.No. Description Qty Unit Rate Amount


20 Supplying and drawing co-axial TV cable
RG-6 grade, 0.7 mm solid copper conductor
PE insulated, shielded with fine tinned
copper braid and protected with PVC
sheath in the existing surface/ recessed
steel/ PVC conduit as required. 140 Mtrs 49.98 6997.00
21 Supplying and drawing of UTP 4 pair CAT
6A LAN Cable in the existing surface/
recessed steel/ PVC conduit as required.
21.1 1 run of cable 670 Mtrs 126.59 84815.00
22 Supplying and fixing of following dia
uPVC pipe along with elbows, tees, etc and
fixing the pipe on wall by using suitable
saddles for fixing etc complete as required.
22.1 25 mm dia UPVC pipe 25 Mtrs 172.47 4312.00
22.2 32 mm dia UPVC pipe
25 Mtrs 220.59 5515.00
23 Supplying and fixing of following pair
crone box with crone module on
surface/recess i/c fixing crone, termination
of telephone wires etc. as required.
23.1 20 Pair crone box
1 Each 6013.74 6014.00
24 Supply and fixing of size not less than 295 x
195 x 100mm weather proof thermo plastic
cable looping box of IP 55 for placing TV
cables at terrace i/c accessories for fixing
directly on wall etc., complete job as
required 1 Each 1098.39 1098.00
Sub Head-II (Fittings)
25 Supply of recessed type (suitable for
grid/POP ceiling 600 mm x 600 mm) LED
fitting with EXTRUDED ALUMINUM/
CRCA White powder coated housing,
nominal colour temparature not less than
5700 K, CRI not less than 80%, THD<10%
light output 3600 lumens (nominal),
wattage with minimum of 100 lumens for
watt not more complete with control driver
with surge protection not less than 2 KV
suitable for operation on 230 volts, 50 Hz
single phase AC supply. 22 Each 3724.30 81935.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 311

S.No. Description Qty Unit Rate Amount


26 Supply of Surface/Recess LED down light
fitting (round type) with pressure die cast
aluminium housing having nominal colour
temperature not less than 5700 K, system
lumen output not less than 1200 lumens
(nominal) and with efficacy minimum of
100 lumens per watt, CRI not less than 80,
in built electronic driver and surge
protection not less than 2 kV etc. as
required. 81 Each 1226.21 99323.00
27 Supply of integrated LED Batten Light
fitting of extruded aluminium housing
with high quality polycarbonate diffuser,
1200mm long, having nominal colour
temperature not less than 5700K, system
lumen output 1800 (nominal) and system
wattage not more than 20 W, CRI not less
than 80 with surge protection not less than
2 KV 28 Each 1529.34 42822.00
28 Supply of wall mounted pressure die cast
aluminium housing LED Bulk head fitting
with IP66 protection lumen output not less
than 1000 and efficacy minimum of 100
lumens per watt complete with LED
module, driver etc as required.
4 Each 1551.79 6207.00
29 Supply surface mounted 600 mm long
batten type LED Mirror light fitting lumens
output not less than 1000 lemens and
efficacy minimum of 100 lumens/watt
colour temperature 5700K (nominal), with
built in surge protector etc as required.
2 Each 418.98 838.00
30 Supply Installation, testing and
commissioning of 1200 mm sweep, BEE 5
star rated, ceiling fan with Brush Less
Direct Current (BLDC)Motor, class of
insulation: B, 3 nos. blades, 30 cm long
down rod, 2nos. canopies, shackle kit,
safety rope, copper winding, Power Factor
not less than 0.9, Service Value (CMM/W)
minimum 6.85,Air delivery minimum 215
CMM,350 RPM (tolerance as per IS : 374-
2019), THD less than 10%, with remote or
suitable to work on existing electronic
regulator unit for speed control and all
remaining accessories including safety pin,
nut bolts, washers, temperature rise=75
degree C (max.), insulation resistance more
than 2 mega ohm, suitable for 230 V, 50 Hz,
single phase AC Supply, earthing etc.
complete as required. 23 Each 2902.81 66765.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 312

S.No. Description Qty Unit Rate Amount


31 Supply, Installation, testing and
commissioning of Exhaust fan of size
250mm sweep, body made of Engineering
plastic, plastic blades in the existing
opening / in existing ventilator frame,
connections etc., as required. 10 Each 2185.50 21855.00
32 Supply heavy duty metal body Exhaust fan
of size 300 mm sweep & 1400 rpm in the
existing opening complete with
connections etc., as required. 13 Each 4879.79 63437.00
33 Installation, testing and commissioning of
Recessed type LED light fitting including
suspension arrangement with metal chain,
connections with 3 core 1.5 sq.mm copper
conductor FR PVC insulated round PVC
sheathed cable in flexible metal conduit
complete etc as required. 22 Each 593.19 13050.00
34 Installation, testing and commissioning of
pre-wired, fluorescent fitting/compact
fluorescent fittings/LED fitting Surface /
Recessed / square / round fitting with all
accessories including connections with 1.5
sq.mm FRLS PVC insulated, copper
conductor, single core cable and earthing
etc as required. 115 Each 219.04 25190.00
35 Installation of exhaust in the existing
opening, including making good damage,
connection, testing, commissioning etc. s
required
Upto 450mm sweep 13 Each 478.49 6220.00
Sub Head-III (DBs & MCCB/MCBs)
36 Providing and fixing following rating and
breaking capacity and pole MCCB with
thermomagnetic release and terminal
spreaders in existing cubicle panel board
including drilling holes in cubicle panel,
making connections, etc. as required.
36.1 100 amps, 4P, 30 KA, MCCB
1 Each 8211.87 8212.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 313

S.No. Description Qty Unit Rate Amount


37 Supplying and fixing of following ways
surface/ recess mounting, vertical type, 415
V, TPN MCCB distribution board of sheet
steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar,
common neutral link, earth bar, din bar for
mounting MCBs with a provision for
MCCB as incomer, inter connection
between Incomer MCCB and bus bars (but
without MCBs and incomer ) as required .
(Note : Vertical type MCB/MCCB TPDB is
normally used where 3 phase outlets are
required.) Cost of Incomer MCC not
included in this rate of this item.
37.1 4 way (4 + 12), Double door 1 Each 16295.45 16295.00
38 Providing and fixing following rating and
breaking capacity and pole MCB with
thermomagnetic release and terminal
spreaders in existing cubicle panel board
including drilling holes in cubicle panel,
making connections, etc. as required.
38.1 63A 4P 25KA MCB 1 Each 2094.27 2094.00
39 Supplying and fixing of following ways
surface/ recess mounting, vertical type, 415
V, TPN MCB distribution board of sheet
steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar,
common neutral link, earth bar, din bar for
mounting MCBs (but without MCBs and
incomer ) as required . (Note : Vertical type
MCB/MCCB TPDB is normally used where
3 phase outlets are required.)

39.1 4 way (4 + 12), Double door


1 Each 7987.51 7988.00
40 Supplying and fixing following way,
horizontal type three pole and neutral,
sheet steel, MCB distribution board, 415 V,
on surface/ recess, complete with tinned
copper bus bar, neutral bus bar, earth bar,
din bar, interconnections, powder painted
including earthing etc. as required. (But
without MCB/RCCB/Isolator)
40.1 4 way (4 + 12), Double door 2 Each 4349.96 8700.00
40.2 6 way (4 + 18), Double door 1 Each 5288.85 5289.00
40.3 8 way (4 + 24), Double door 2 Each 6344.71 12689.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 314

S.No. Description Qty Unit Rate Amount


41 Supplying and fixing Cable End Box
(Loose Wire Box) suitable for following
triple pole and neutral, sheet steel, MCB
distribution board, 415 Volts, on surface/
recess, complete with testing and
commissioning etc.as required.
41.1 For 4 way, Double door, TPN MCB DB 2 Each 1148.36 2297.00
41.2 For 6 way, Double door, TPN MCB DB 1 Each 1195.15 1195.00
41.3 For 8 way, Double door, TPN MCB DB 2 Each 1424.82 2850.00
42 Supplying and fixing Cable End Box
(Loose Wire Box) suitable for following
triple pole and neutral, sheet steel, verticle
MCB distribution board, 415 Volts, on
surface/ recess, complete with testing and
commissioning etc.as required. 1 Each 1244.06 1244.00
43 Supplying and fixing 5 amps to 32 amps
rating, 240/415 volts, “C” curve, miniature
circuit breaker suitable for inductive load
of following poles in the existing MCB DB
complete with connections, testing and
commissioning etc. as required. (10 kA
breaking capacity ).
43.1 Single Pole 90 Each 272.20 24498.00
44 Supplying and fixing followings amps
rating, 415 volts, “C” curve, miniature
circuit breaker suitable for inductive load
of following poles in the existing MCB DB
complete with connections, testing and
commissioning etc. as required. (10 kA
breaking capacity ).
44.1 63A, Triple Pole 4 Each 2018.17 8073.00
44.2 63 Amp, FP 2 Each 2779.15 5558.00
44.3 40 Amp, TP 4 Each 2179.32 8717.00
44.4 40 Amp, FP 3 Each 2779.15 8337.00
45 Supplying and fixing following rating, four
pole, 415 V, isolator in the existing MCB DB
complete with connections, testing and
commissioning etc. as required.
45.1 63 A 1 Each 1099.45 1099.00
SUB_HEAD - IV (LIGHTNING
CONDUCTOR)
46 Providing and fixing of lightning
conductor finial, made of 25 mm dia 300
mm long, G.I. tube, having single prong at
top, with 85 mm dia 6 mm thick G.I. base
plate including holes etc. complete as
required. 5 Set 550.79 2754.00
47 Providing and fixing G.I. tape 20 mm X 3 mm
thick on parapet or surface of wall for
lightning conductor complete as required.
(For horizontal run) 210 Meter 133.98 28136.00
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 315

S.No. Description Qty Unit Rate Amount


48 Providing and fixing G.I. tape 20 mm X 3 mm
thick on parapet or surface of wall for
lightning conductor complete as required.
(For vertical run) 80 Meter 209.47 16758.00
49 Providing and fixing testing joint, made of 20
mm X 3 mm thick G.I. strip, 125 mm long,
with 4 nos. of G.I. bolts, nuts, chuck nuts and
spring washers etc. complete as required. 5 set 128.66 643.00
50 Earthing with G.I. earth plate 600 mm X 600
mm X 6 mm thick including accessories, and
providing masonry enclosure with cover
plate having locking arrangement and
watering pipe of 2.7 metre long etc. with
charcoal/ coke and salt as required. (For
Lightning conductor) 5 Set 7944.98 39725.00
51 Providing and laying G.I. tape 32 mm X 6
mm from earth electrode directly in ground
as required. 75 Meter 207.34 15551.00
SUB_HEAD - V (RO Water Cooler)
52 Supplying, installation testing
commissioning of 60/80 LPH capacity water
coolers with inbuilt arrangement of Aqua
guard RO purification with 7 stages of
filtration and fully automatic etc complete as
required. 2 Each 115967.48 231935.00
SUB HEAD - VI (LT PANELS)
Outdoor LT Panel Non-Essential load
53 Supplying, installation, testing and
commissioning of floor mounted weather
proof outdoor type cubicle panel of size not
less than 1800mm (Width) x 1350 mm
(Height) x 400mm (Depth) made out of 2
mm thick CRCA sheet for frame work and
covers, compartmentalized, dust and vermin
proof, hinged doors with knobs 3mm thick
gland plate i/c. cleaning and finishing with 7
tank process for powder coating in approved
shade, 300 amps capacity 4 strip aluminium
bus bars of high conductivity, DMC/ SMC
bus bar supports, PVC sleeves, bottom base
channel of ISMC 100x50mm MS ( 9.2 Kg/m),
G.I earth bar of size 25mm x 5 mm at the rear
for the entire width of the panel with 2 nos.
earth studs ,connections from busbar to
switchgear and control wiring with required
size solid aluminium bus/ FRLS PVC
insulated copper conductor cable of suitable
size, cable alley, cable gland plates including
providing cement concrete padestal bricks for
supporting and fixing the following
switchgear, as per attached specifications and
confirming to the CPWD general
specifications part-I (Internal), part-II

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 316

S.No. Description Qty Unit Rate Amount


(External), part-IV (Substation)
(I) Incomer:
a) 250 Amps four pole, 50KA breaking
capacity (Ics) at 415V short circuit current
rating MCCB, microprocessor type release
with over load and short circuit fixed, in-built
earth fault protection, with Spreader links
and rotary handle - 1 No.
b) Digital Multifunction meter - 1 Set.
c) CTs of ratio 250 / 5 A class 1.0 accuracy,
5VA burden-1 Set
d) 3 Nos. Phase indication LED lamps with
2A SPMCBs - 1 Set.
II) Busbar:
4 Strip Aluminium Bus bars of 300Amps
capacity with heat shrinkable coloured
sleeves and i/c DMC/SMC bus bars supports
at required intervals complete etc., - 1 Set
III) Outgoing:
a) 125 Amps four pole MCCB - 36 KA along
with , S/C, O/L Protection (Icu=Ics) with
Thermal Magnetic release with Spreader
links and extended rotary handle -2 No.
b) 63 Amps Four pole, 25 KA MCCB
(Icu=Ics) with thermal magnetic release and
S/C, O/C protection with Spreader links and
extended rotary handle -2 Nos. 1 Job 224269.02 224269.00
Outdoor LT Panel Essential load
54 Supplying, installation, testing and
commissioning of floor mounted weather
proof outdoor type cubicle panel of size not
less than 1800mm (Width) x 1350 mm
(Height) x 400mm (Depth) made out of 2
mm thick CRCA sheet for frame work and
covers, compartmentalized, dust and vermin
proof, hinged doors with knobs 3mm thick
gland plate i/c. cleaning and finishing with 7
tank process for powder coating in approved
shade, 300 amps capacity 4 strip aluminium
bus bars of high conductivity, DMC/ SMC
bus bar supports, PVC sleeves, bottom base
channel of ISMC 100x50mm MS ( 9.2 Kg/m),
G.I earth bar of size 25mm x 5 mm at the rear
for the entire width of the panel with 2 nos.
earth studs ,connections from busbar to
switchgear and control wiring with required
size solid aluminium bus/ FRLS PVC
insulated copper conductor cable of suitable
size, cable alley, cable gland plates including
providing cement concrete padestal bricks for

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 317

S.No. Description Qty Unit Rate Amount


supporting and fixing the following
switchgear, as per attached specifications and
confirming to the CPWD general
specifications part-I (Internal), part-II
(External), part-IV (Sub station)
(I) Incomer:
a) 125 Amps four pole, 36KA breaking
capacity (Ics) at 415V short circuit current
rating MCCB, microprocessor type release
with over load and short circuit fixed, in-
built earth fault protection, with Spreader
links and rotary handle - 1 No.
b) Digital Multifunction meter - 1 Set.
c) CTs of ratio 300 / 5 A class 1.0 accuracy,
5VA burden-1 Set
d) 3 Nos. Phase indication LED lamps with
2A SPMCBs - 1 Set.
II) Busbar:
4 Strip Aluminium Bus bars of 200Amps
capacity with heat shrinkable coloured
sleeves and i/c DMC/SMC bus bars
supports at required intervals complete
etc., - 1 Set
III) Outgoing:
a) 100 Amps four pole MCCB - 36 KA along
with , S/C, O/L Protection (Icu=Ics) with
Thermal Magnetic release with Spreader
links and extended rotary handle -1 No.
b) 63 Amps Four pole, 25 KA MCCB
(Icu=Ics) with thermal magnetic release
and S/C, O/C protection with Spreader
links and extended rotary handle -2 Nos. 1 Job 181718.09 181718.00
Indoor LT Panels
Non Essential Panel

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 318

S.No. Description Qty Unit Rate Amount


55 Supplying, installation, testing and
commissioning of floor mounted indoor
type cubicle panel of size not less than
1050mm (Width) x 1550 mm (Height) x
350mm (Depth) made out of 2 mm thick
CRCA sheet for frame work and covers,
compartmentalized, dust and vermin
proof, hinged doors with knobs 3mm thick
gland plate i/c. cleaning and finishing with
7 tank process for powder coating in
approved shade, 200 amps capacity 4 strip
aluminium bus bars of high conductivity,
DMC/ SMC bus bar supports, PVC sleeves,
bottom base channel of ISMC 100x50mm
MS ( 9.2 Kg/m), G.I earth bar of size 25mm
x 5 mm at the rear for the entire width of
the panel with 2 nos. earth studs
,connections, from busbar to switchgear
and control wiring with required size solid
aluminium bus/ FR PVC insulated copper
conductor cable of suitable size, cable alley,
cable gland plates including providing
cement concrete padestal bricks for
supporting and fixing the following
switchgear, as per attached specifications
and confirming to the CPWD general
specifications part-I (Internal), part-II
(External), part-IV (Sub station) as
amended upto date complete as required.
(I) Incomer:
a) 125 Amps four pole MCCB - 36 KA along
with , S/C, O/L Protection (Icu=Ics) with
Thermal Magnetic release with Spreader
links and extended rotary handle - 1 No.
b) 4 Strip aluminium bus bars of 200 Amps
capacity with heat shrinkable coloured
sleeves and i/c DMC/SMC bus bars
supports at required intervals - 1 Set.
c) Digital Multifunction meter - 1 Set.
d) CTs of ratio 125 / 5 A class 1.0 accuracy,
5VA burden-1 Set
e) 3 Nos. Phase indication LED lamps with
SPMCBs - 1 Set.
II) Outgoing:
a) 100 Amps Four pole, 25 KA MCCB
(Icu=Ics) with thermal magnetic release
and S/C, O/C protection with Spreader
links and extended rotary handle - 1 Nos.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 319

S.No. Description Qty Unit Rate Amount


a) 63 Amps Four pole, 25 KA MCCB
(Icu=Ics) with thermal magnetic release and
S/C, O/C protection with Spreader links and
extended rotary handle -2 Nos. 1 Job 103702.55 103703.00
Essential Panel
56 Supplying, installation, testing and
commissioning of floor mounted indoor type
cubicle panel of size not less than 1050mm
(Width) x 1550 mm (Height) x 350mm
(Depth) made out of 2 mm thick CRCA
sheet for frame work and covers,
compartmentalized, dust and vermin proof,
hinged doors with knobs 3mm thick gland
plate i/c. cleaning and finishing with 7 tank
process for powder coating in approved
shade, 200 amps capacity 4 strip aluminium
bus bars of high conductivity, DMC/ SMC
bus bar supports, PVC sleeves, bottom base
channel of ISMC 100x50mm MS ( 9.2 Kg/m),
G.I earth bar of size 25mm x 5 mm at the rear
for the entire width of the panel with 2 nos.
earth studs ,connections, from busbar to
switchgear and control wiring with required
size solid aluminium bus/ FR PVC insulated
copper conductor cable of suitable size, cable
alley, cable gland plates including providing
cement concrete pedestal bricks for
supporting and fixing the following
switchgear, as per attached specifications and
confirming to the CPWD general
specifications part-I (Internal), part-II
(External), part-IV (Substation) as amended
up to date complete as required.
(I) Incomer:
a) 100 Amps four pole MCCB - 36 KA along
with , S/C, O/L Protection (Icu=Ics) with
Thermal Magnetic release with Spreader
links and extended rotary handle - 1 No.
b) 4 Strip aluminium bus bars of 200 Amps
capacity with heat shrinkable coloured
sleeves and i/c DMC/SMC bus bars supports
at required intervals - 1 Set.
c) Digital Multifunction meter - 1 Set.
d) CTs of ratio 100 / 5 A class 1.0 accuracy,
5VA burden-1 Set
e) 3 Nos. Phase indication LED lamps with
SPMCBs - 1 Set.
II) Outgoing:
a) 63 Amps Four pole, 25 KA MCCB
(Icu=Ics) with thermal magnetic release and
S/C, O/C protection with Spreader links and
extended rotary handle -3 Nos. 2 Job 101487.10 202974.00
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 320

S.No. Description Qty Unit Rate Amount


SUB HEAD VII (DRINKING WATER
PUMPS)
57 Supply, installation, testing and
commissioning of 2.2 KW/3 HP HP, ISI
marked open well submersible pump set
capable of delivering water for following
discharges and head (nominal) complete with
standard length of submersible cable,
operated on 415 volts, 50 Hz, 3 phase AC
supply as required.
57.1 Pump delivering 6.5 to 2.2 litres per second at
a head range of 18-36 metres 2 Each 42168.71 84337.00
58 Supplying and laying 50 mm dia, medium
class, ISI marked, G.I. pipe for connection
from pump to UG Tank along with
accessories like sockets, bends, Tee, unions,
reducers etc., including painting the pipe,
complete as required. 10 Metre 1126.95 11269.00
59 Supplying and fixing following ISI marked,
valves in existing GI Pipe line including
cutting, threading the GI pipe complete as
required.
59.1 50 mm G.M Non Return Valve 2 Each 1536.63 3073.00
59.2 50 mm G.M Gate Valve 2 Each 1091.64 2183.00
60 Supplying and laying 3 core 4 sq.mm PVC
insulated PVC sheathed copper conductor
submersible flat cable in existing metal/
HDPE / PVC/ pipe/ in bore well/ in sump
including fixing the cable to GI/HDPE pipe
with suitable cable tags etc. as required. 30 Metre 178.58 5357.00
Pump Panel
61 Supply, installation, testing and
commissioning of suitable size outdoor type
pump control panel made of 2 mm thick
CRCA sheet for frame work and covers,
compartmentalized, dust and vermin proof,
hinged doors with knobs 3mm thick gland
plate including cleaning and finishing with 7
tank process for powder coating in approved
shade, 100 amps capacity 4 strip Copper bus
bars of high conductivity, DMC/ SMC bus
bar supports, PVC sleeves, bottom base
channel of ISMC 75 (75 mm x 40 mm x 4.4
mm thick), G.I earth bar of size 25mm x 5
mm at the rear for the entire width of the
panel with 2 nos. earth studs ,connections
from busbar to switchgear and control wiring
with required size FRLS PVC insulated
copper conductor cable of suitable size, cable
alley, cable gland for supporting and fixing
the following switchgear, as per attached
specifications and confirming to the CPWD

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 321

S.No. Description Qty Unit Rate Amount


general specifications part-I (Internal), part-II
(External), part-IV (Sub station).
Incoming
a) 63 A, 4 pole MCCB, 25 KA rating,
(Icu=100% Ics) thermal magnetic release type
complete with Rotary handle, spreader
terminals etc. - 1 No.
b) Digital Multifunction Meter - 1 No.
c) R,Y,B LED indication lamps along with 2A
control MCBs - 1 set.
d) Suitable ratio CTs - 1 set.
Outgoing:
Pump Star Delta control compartments
suitable for 7.5HP motors including
supplying and fixing following items in each
compartment - 2 Nos.
a) 63A TP MCB - 1 No.
b) Star Delta starter with thermal over relay
& timer delay for Y-D - 1 Set
c) Single phasing and Dry run preventer
(current sensing type) - 1 No.
d) Digital ammeter - 1 No.
e) ON/OFF illuminated push buttons - 1 set.
f) Trip indication lamps - 1 No.
g) Auto/Manual Selector switch - 1 No. 1 Job 84888.26 84888.00
SUB HEAD VIII (Indoor Courts Lighting)
Badminton Court:
62 Supplying and fixing IP -65/66 protected
LED Linear High-Bay light fitting with min.
12000 system lumens,built in Aluminium
Extrusion with Grey power coating for
proper heat dissipation. with CCT 5000-5700
K. All the LEDs shall be LM80 Complied as
per L70 standard for Min 50000 Hours, High
quality Polycarbonate cover with integrated
lens with optional narrow & wide beam
angles for uniform distribution , Built-in
potted, electronic LED driver with APFC
(SMPS based constant current supply), lower
THD, Open Circuit protection, Over Voltage
protection, buitin Surge protector shall not be
lessthan 4 KV & other safety test as per IS
15885 Part-2/Sec 13 & CISPR 15. Power
Factor of Driver with More than 0.95,CRI >
70%and THD less than 10% complete i/c
surface mounted with clamp/hanging upto
100mm height with stainless steel rods of
suitable size and necessary items for
mounting etc., complete with connections
,testing and commissioning etc., as required.
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 322

S.No. Description Qty Unit Rate Amount


62.1 120W LED Linear Highbay light fitting 46 Nos 16256.27 747788.00
63 Supply and laying of 3 core 2.5 sq.mm PVC
insulated and PVC sheathed copper
conductor flexible cable for connection of
high bay/ flood/Led lights in existing
conduit/surface/ hume pipe etc complete
as required. 300 Mtr 347.50 104250.00
64 Supplying and fixing of following sizes of
medium class PVC conduit along with
accessories in surface/recess including
cutting the wall and making good the same
in case of recessed conduit as required.
64.1 25mm 300 Mtr 154.18 46254.00
SUB HEAD VIII (Earthing)
65 Earthing with G.I earth plate 600 mm x 600
mm x 6 mm thick including accessories,
and providing masonry enclosure with
cover plate having locking arrangement
and watering pipe of 2.7 metre long etc.
with charcoal/coke and salt as required. 2 Each 7944.98 15890.00
66 Providing and fixing 25 mm x 5 mm GI
strip in 40 mm dia G.I. pipe from earth
electrode including connection with brass
nut, bolt, spring, washer excavation and re-
filling etc. as required.
20 Metre 750.69 15014.00
67 Providing and fixing 25mm x 5mm GI
strip on surface or in recess for connections
etc. as required. 30 Metre 259.45 7784.00
SUB HEAD IX (LT Cables)
68 Supplying of following sizes of XLPE
insulated and PVC sheathed aluminium
conductor armoured cable of 1.1 KV grade
conforming to IS:7098 (Part-I) 1988 with
upto date amendments duly ISI marked
complete as required.
68.1 3 ½ x 185 sq.mm 580 Metre 2330.10 1351458.00
68.2 3 ½ x 95 sq.mm 110 Metre 1239.67 136364.00
68.3 3 ½ x 70 sq.mm 110 Metre 764.14 84055.00
69 Laying of one numberPVC insulated and
PVC sheathed / XLPE power cable of
1.1KV grade of following size in the
existing RCC / HUME / TRAY/ METAL
pipe as required.
69.1 Above 35 sq.mm and up to 95 sq.mm 220 Metre 60.61 13334.00
69.2 Above 95 sq.mm and up to 185 sq.mm 580 Metre 81.87 47485.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 323

S.No. Description Qty Unit Rate Amount


70 Supplying and making end termination
with brass compression gland and
aluminium lugs for following size of PVC
insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade
as required.
70.1 3.5 X 185 sq.mm (57mm) 2 Each 930.39 1861.00
70.2 3.5 X 95 sq. mm (45mm) 2 Each 625.22 1250.00
70.3 3.5 X 70 sq. mm (38mm) 2 Each 497.62 995.00
71 Providing, laying and fixing following dia
RCC pipe NP2 class ( light duty ) in ground
complete with RCC collars, jointing with
cement mortar 1:2 ( 1 cement : 2 fine sand )
including trenching ( 75 cm deep ) and
refilling etc as required
71.1 300 mm dia 50 Metre 1212.16 60608.00
72 Supplying and laying of following size
DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc.
conforming to IS 14930, Part II complete
with fitting and cutting, jointing etc.direct
in ground (75 cm below ground level)
including excavation and refilling the
trench but excluding sand cushioning and
protective covering etc., complete as
required.
72.1 90 mm dia (OD-90 mm & ID-76 mm
nominal) 120 Metre 308.36 37003.00
72.2 120 mm dia (OD-120 mm & ID-103 mm
nominal) 450 Metre 391.29 176081.00
SUB HEAD X (Split ACs)
73 Supply, Installation, Testing and
Commissioning of following tonnage, 5
star rated wall mounted (Inverter model)
split type Air conditioner units with ISEER
ratio not less than 4.5 , rotary compressor
and all accessories including standard
copper refrigerant pipe (up to 3 mtrs) with
R32/R410A refrigerant gas, PVC drain pipe
and control cable between indoor and
outdoor units, outdoor unit stand & cord
less remote suitable for operation on 230
volts, 50 HZ AC single phase etc., complete
as required. (Condenser coil should be
made out of copper tubing only).

73.1 1.5 TR Split AC 11 Nos 60291.48 663206.00


C2 : Fire Fighting System (Downcomer
system)
Electric Pump Terrace
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 324

S.No. Description Qty Unit Rate Amount


74 Supplying, installation, testing and
commissioning of electric driven terrace
pump suitable for automatic operation and
consisting of following, complete in all
respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal,
split casing pump of cast iron body &
bronze impeller with stainless steel shaft,
mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction
motor TEFC type suitable for operation on
415 volts, 3 phase, 50 Hz, AC supply with
IP55 class of protection for enclosure,
horiziontal foot mounted type with Class-
'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate,
coupling, coupling guard, foundation bolts
etc.as required.
(d) Suitable cement concrete foundation
duly plastered and with anti vibration
pads.
450 lpm at 35 m Head 2 Set 91659.65 183319.00
Fire Control Panel
75 Fabrication, supply at site, installation,
testing and commissioning of floor
mounted/Wall Mounted outdoor type
cubical MV switchboard of cubicle
construction , fabricated out of 14 G ( 2.0
mm ) nominal thickness CRCA sheet steel,
of suitable size front and back openable,
hinged, single shuttered, double door on
front and back, with locking arrangement,
dust and vermin proof ,rubber gaskets,
connections and interconnections using
suitable size of pvc insulated aluminium
conductor single core cables and cable lugs,
25 mm x 5 mm GI earth strip for earthing,
dinrail for mounting switchgear, metering
arrangements, drilling holes, detachable
gland plates / knockout plates for
facilitating entry / exit of UG cables,
providing MS channel of designation ISMC
75 ( 75 mm x 40 mm x 6.8 kg / metre ) for
floor mounting of MV panel installing on
suitable brick/CC pedestal at suitable
height from floor level and complete with
supplying and fixing of following
switchgear and metering instruments etc.
as required.

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 325

S.No. Description Qty Unit Rate Amount


The Panel shall generally confirm to
CPWD General Specification for Electrical
works, Part-I Internal 2013, Part II
External 1994 and Part IV substation
equipment 2013 as amended upto date.
The Panel shall be powder coated of
approved shade after 7 tank treatment
process complete as required. The size of
the Panel shall be not less than 1000
mm(H) x 900mm (W) x 300mm (D)
INCOMING
(a) 125 Amps FP MCCB ,25 kA Breaking
capacity with thermo magnetic release and
terminal spreaders,extended rotory handle
etc., - 1 no.
(b) 125 Amps 4 strip aluminium busbars - 1
set
(c) Digital Multi function Meter for
measuring V, A, F & PF - 1 no.
(d) LED phase indication lamps - 1 set
(e) Current Transformers 100 / 5 Amps - 3
nos
(f) 2A SP MCB's - 1 Set
OUTGOING
Automatic Star-Delta starter - 2 Nos
Each Starter consists of the following
(a) 40 Amps TP MCB- 1 nos,40A Power
Contactors-2 nos, 25A TP Power
contactors-1 nos , Single phase preventors-1
Nos, Star-delta timer-1 Nos, Thermal
overload relays-1 Nos.
(b) Selector switch for local/remote , auto
/ manual / off operation - 2sets
(d) On-off indication lamps - 2sets
(e) On & off illumination Push Buttons-2
sets
Water Level Controller - 1 No
a) Water level controller 240V/50/60Hz-1
No
b) Sensor probes-1 set
c) On delay 24-240VAC/DC 2 C/O-1 set
d) Hooter-1 No, Pushbutton with NO &
indicating lights-1 set
1 Set 103184.64 103185.00
PIPES & Accessories

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 326

S.No. Description Qty Unit Rate Amount


76 Providing, laying, testing & commissioning
of 'C' class heavy duty MS pipe conforming
to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges, tapers,
nuts bolts, gaskets etc. and fixing the pipe
on the wall/ceiling with suitable
clamp/support frame and painting with
two or more coats of synthetic enamel paint
of required shade complete as required :
76.1 65 mm dia ( Terrace Pump Delivery) 25 Mtr 1716.17 42904.00
76.2 80 mm dia ( Terrace pump suction) 25 Mtr 2004.32 50108.00
76.3 100 mm dia ( For Riser ) 50 Mtr 2716.73 135837.00
77 Providing laying, testing & commissioning
of 'C' class heavy duty MS pipe conforming
to IS 1239/3589 i/c fittings like elbows,
tees, flanges, tapers, nut bolts, gaskets etc.
in ground i/c excavation & providing
cement concrete blocks as supports,
anticorrosive treatment with
coalter/asphalt tape as per IS
10221,refilling the trench etc of following
sizes complete as required.
77.1 150 mm dia ( From Fire brigade inlet to
riser) 60 Mtr 4044.79 242687.00
78 Supplying, fixing, testing & commissioning
of double flanged sluice valve of rating PN
1.6 with non rising spindle, bronze/gun
metal seat, ISI marked complete with nuts,
bolts, washers, gaskets and conforming to
IS 780 of following sizes as required :
78.1 150 mm dia ( Fire Brigade Inlet) 3 Each 24202.83 72608.00
78.2 100mm dia ( between header to Riser) 3 Each 15567.78 46703.00
78.3 80 mm dia ( Suction Lines of pumps & by
pass line)
3 Each 11373.06 34119.00
78.4 65 mm dia ( Delivery Lines of pumps) 2 Each 9820.64 19641.00
79 Providing, installation, testing and
commissioning of non-return valve of
following sizes confirming to IS: 5312
complete with rubber gasket, GI bolts, nuts,
washers etc.as required :
79.1 65 mm dia ( Delivery Lines of pumps ) 2 Each 6824.26 13649.00
79.2 80mm dia ( by pass line)
1 Each 8177.84 8178.00
79.3 100 mm dia ( For Header to riser )
3 Each 11749.47 35248.00
79.4 150 mm dia ( Fire Brigade Inlet) 3 Each 18911.85 56736.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 327

S.No. Description Qty Unit Rate Amount


80 Supplying and fixing single headed
internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63
mm dia with cast iron wheel ISI marked
conforming to IS 5290 (Type -A) with blank
Gunmetal/Stainless Steel cap and chain as
required :
80.1 Single headed Stainless steel 4 Each 6527.60 26110.00
81 Supplying & fixing 63 mm dia gun metal
short branch pipe with 20 mm nominal
internal diameter size nozzle conforming to
IS 903 suitable for instantaneous connection
to interconnect hose pipe coupling as
required :
81.1 Stainless Steel (Grade 304) 4 Each 1767.20 7069.00
82 Supplying and fixing of First Aid Hose
Reel with MS construction spray painted in
post office red, conforming to IS 884 with
upto date amendments, complete with the
following as required
(a) 40 m long 20 mm ( nominal internal )
dia water hose Thermoplastic (Textile
reinforced) Type 2 as per IS : 12585
(b) 20 mm ( nominal internal ) dia gun
metal globe valve & nozzle
(c) Drum and brackets for fixing the
equipments on wall.
Connections from riser with 25 mm dia
stop gun metal valve & M.S. Pipe and
socket. 4 Each 12837.22 51349.00
83 Supplying and fixing 63 mm dia, 15 m long
RRL hose pipe with 63 mm dia male and
female couplings duly bound with GI wire,
rivets etc. conforming to IS 636 (type-A) as
required :
83.1 Stainless Steel (Grade 304) 8 Each 4729.56 37836.00
84 Supplying and fixing air vessel made of 250
mm dia, 8mm thick MS sheet, 1200 mm in
height with air release valve on top and
flanged connection to riser, drain
arrangement with 25 mm dia gun metal
wheel valve with required accessories,
pressure gauge and paintingwith synthetic
enamel paint of approved shade as
required. 3 Each 19398.85 58197.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 328

S.No. Description Qty Unit Rate Amount


85 Supplying and fixing of fire brigade
connection of cast iron body with gun metal
male instantaneous inlet couplings complete
with cap and chain as reqd. for suitable dia
MS pipe connection conforming to IS 904 as
required:
85.1 2 way-100 mm dia M.S. Pipe 3 Each 7168.77 21506.00
86 Providing & fixing of pressure switch in M.S.
pipe line including connection etc. as
required. 2 Each 1643.86 3288.00
87 Providing & fixing pressure gauge (100 mm
dia dial) in delivery side of Pumps (pressure
range 0-10 kg/cm2) including connections
etc., as required. 2 Each 1015.78 2032.00
88 Supplying of following size of XLPE
insulated PVC sheathed, armoured, Copper
conductor cable of 1.1 KV grade, ISI marked
on etc as required
88.1 3 x 6 sq.mm (for pump power supply) 80 Metre 559.41 44753.00
88.2 3 x 2.5 sq.mm (for Pressure switch control
wiring) 40 Metre 288.40 11536.00
88.3 6 x 2.5 sq.mm (for GF Switch control wiring) 40 Metre 509.05 20362.00
89 Laying and fixing of one number PVC
insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on
wall surface as required
89.1 Up to 35 sq. mm (clamped with 1mm thick
saddle) 45 Metre 58.48 2632.00
90 Supplying and installing following size of
perforated Hot Dipped Galvanised Iron cable
tray (Galvanisation thickness not less than 50
microns) with perforation not more than
17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with
G.I. suspenders including G.I. bolts & nuts,
etc. as required.
90.1 100 mm width X 50 mm depth X 1.6 mm
thickness 30 Metre 711.35 21341.00
91 Supplying and making end termination with
brass compression gland & copper lugs for
following sizes of PVC insulated, PVC
sheathed/ XLPE Cu. conductor cables of 1.1
KV grade as required.
91.1 3 X 6 sq.mm (19mm) 4 Each 343.34 1373.00
91.2 3 X 2.5 sq.mm 4 Each 322.22 1289.00
91.3 6 X 2.5 sq.mm (19mm) 4 Each 343.86 1375.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 329

S.No. Description Qty Unit Rate Amount


92 Supplying and fixing of hose cabinet of size
760 mm x 600 mm x 250 mm (nominal) made
up of FRP sheet with 6 mm thick glazed glass
doors including necessary locking
arrangement suitable to accommodate 2 nos.
15 mtr. long Hose pipe, 1 no. branch pipe,
mounted on wall OR on Existing angular iron
support & duly painted with Post office red
externally and white internally with synthetic
enamel paint complete in all respect, for
Internal and external hydrants, as required. 4 Each 6225.51 24902.00
93 Providing and Fixing CO2 type, 4.5 kgs,
capacity Fire Extinguishers with ISI mark in
seam less drawn steel cylinder, fitted with
wheel valve, with discharge bend and horn,
complete with initial charge, conforming to IS
15683 along with wall bracket, accessories
etc., complete as required. 8 Each 9417.47 75340.00
94 Providing and Fixing ABC type 6 kgs
capacity, stored pressure type Fire
Extinguishers with ISI mark, fitted with
discharge control valve and pressure gauge,
filled with mono ammonium phosphate
powder, complete with initial charge
conforming to IS 15683 along with wall
bracket, along with accessories etc., complete
as required. 8 Each 3367.72 26942.00
95 Supply, installation, testing and
commissioning of 1 NO & 1 NC auxiliary
contacts ON & OFF Push button switches in
weather proof PVC box i/c fixing on wall,
connections with cables etc., complete as
required. 2 Each 574.04 1148.00
C3: Automatic Addressable Fire Alarm
System
Addressable Fire Alarm System

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 330

S.No. Description Qty Unit Rate Amount


96 Supplying, installation, testing and
commissioning of microprocessor based
intelligent addressable main fire alarm panel,
central processing unit with the following
loop modules and capable of supporting not
less than 240 devices (including detectors)
and minimum 120 detectors per loop and
loop length up to 2 km, network
communication card, minimum 320 character
graphics/ LCD display with touch screen or
other keypad and minimum 4000 events
history log in the non-volatile memory
(EPROM), power supply unit (230 ± 5% V, 50
hz), 48 hrs back-up with 24 volt sealed
maintenance free batteries with automatic
charger. The panel shall have facility to
connect printer to printout log and facility to
have seamless integration with
analog/digital voice evacuation system
(which is part of the schedule of work under
SH: PA System) and shall be complete with
all accessories. The panel shall be compatible
for IBMS system with open protocol
BACnet/ Modbus over IP complete as per
specifications.
96.1 Two Loop Panel 1 Each 254367.94 254368.00
97 Supplying, installation, testing &
commissioning of intelligent analog
addressable photothermal detector complete
with mounting base complete as required. 24 Each 3038.91 72934.00
98 Supplying, installation, testing &
commissioning of addressable manual call
point complete as required. 9 Each 4116.03 37044.00
99 Supplying, installation, testing &
commissioning of addressable horn cum
strobe complete as required. 7 Each 3727.93 26096.00
100 Supplying, installation, testing &
commissioning of fault isolator complete
with base as required. 4 Each 3476.99 13908.00
101 Supplying, installation, testing &
commissioning of addressable fire control
module complete as required. 2 Each 3193.09 6386.00
102 Supplying, installation, testing &
commissioning response indicator on
surface/recess MS box having two LEDs
metallic cover complete with all connections
etc. as required.
1 Each 208.41 208.00
103 Supplying, installation, testing &
commissioning of addressable beam detector
with short circuit isolator (inbuilt or seperate)
complete with emitter and receiver including
connections with remote test features etc
complete as required. 1 Each 79680.51 79681.00
Cor NIL c Cor NIL Ins NIL
Omi NIL Ovw NIL

AE(P) EE
PART D 331

S.No. Description Qty Unit Rate Amount


104 Supplying and drawing following sizes of
FRLS PVC insulated copper conductor single
core cable in the existing surface/ recessed
steel/ PVC conduit as required.
104.1 2 x 1.5 sq mm 550 Metre 74.43 40937.00
105 Supplying and fixing of following sizes of
steel conduit along with accessories in
surface/recess including painting in case of
surface conduit, or cutting the wall and
making good the same in case of recessed
conduit as required.
105.1 20 mm 470 Metre 237.12 111446.00
PA System
106 Supplying, installation, testing &
commissioning of 6 zone, voice alarm
controller with USB, MP3 player (including 6
zone buttons paging station) with seamless
integration facility with main fire alarm panel
for voice evacuation complete as required. 1 Each 134412.82 134413.00
107 Supplying, installation, testing &
commissioning of 1.5/3/6W ceiling speaker
complete as required. 1 Each 1026.08 1026.00
108 Supplying, installation, testing &
commissioning of 1.5/3/6W metal box
ceiling/wall speakers complete as required. 15 Each 1906.50 28598.00
109 Supplying, installation, testing &
commissioning of Voice command keypad 6
zone, with microphone assembly complete as
required. 1 Each 86931.15 86931.00
C4 : CCTV
110 Supply, Installation, Testing and
Commissioning of 5MP IR Fixed Dome,
2.8mm DC Iris, 1/2.8" progressive CMOS
image sensor, Min. Illumination 0.007 (color),
S/N Ratio: 50dB, Electronics Shutter: 1/8 ~
1/32000, IR Distance: 30M,
WDR~120dB/BLC/HLC/3D DNR, Gain
Control: 0 ~100%; SD card up to 256GB, PAN:
0-350, Tilt: 0-70, 2way duplex audio stream,
G.711A/G.711U compression, Line IN&Out
audio interface with inbuilt microphone,
Rotation: 0-350; Video Compression: H.265
HEVC/H.264/MJPEG, Smart Codec; Edge
Analytics: SMD, people counting, Loitering,
intrusion, Tampering, Triple Stream;
Protocals: H.265 HEVC/H.264/MJPEG,
Smart Codec; ONVIF: S/G/T; Op. Temp: -40
to 60 Deg; power consumption max. 6W;
IP66, IP67, IK10, UL, NDAA including
supplying and fixing on the 100mm X
100mm module boxes, cable termination and
fixing accessories complete in all respect as 2 Each 32924.88 65850.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 332

S.No. Description Qty Unit Rate Amount


per instruction of engineer in-charge. etc. as
required.
111 Supply, Installation, Testing and
Commissioning of 5MP IR MFZ Bullet, 2.7-
13.5mm DC Iris, 1/2.8" progressive CMOS
image sensor, Min. Illumination 0.005
(color), S/N Ratio: 50dB, Electronics
Shutter: 1/8 ~ 1/32000, IR Distance: 60M,
WDR~120dB/BLC/HLC/3D DNR, Gain
Control: 0 ~100%; SD card up to 256GB,
Video Compression: H.265
HEVC/H.264/MJPEG, Defog, 2way audio
duplex, Smart Codec; Triple Stream;
Protocals: H.265 HEVC/H.264/MJPEG,
Smart Codec; ONVIF: S/G/T; Op. Temp: -
40 to 60 Deg; power consumption max. 6W;
IP67,IK10,UL &NDAA Compliance
including supplying and fixing on the
100mm X 100mm module boxes, cable
termination and fixing accessories
complete in all respect as per instruction of
engineer in-charge. etc. as required. 9 Each 32924.88 296324.00
112 Supply, installation, testing and
commissioning of 32 channel NVR with 4K
support 4 X 8TB Hard disk drive slot
(without HDD) compression ratio:
H.265/H.264/MJPEG/MPEG4, recording
resolution: 12MP, 5 MP, 3 MP, 2 MP, D1 &
CIF, should support Store video clips and
snapshots to external storage, such as the
client’s PC, ONVIF conformance, RAID 5 &
RAID 6 support, HDMI output port, 1/1
Audio I/O and 16 Alarm Inputs, 6 relay
outputs,Having Operating temp range : –
10°C to 55°C including fixing standard
accessories complete in all respect as
required. 1 Each 101767.81 101768.00
113 Supply, Installation testing &
commissioning of Surveillance grade 8TB
Hard disk drive for recording etc. complete
as required. 2 Each 14367.22 28734.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 333

S.No. Description Qty Unit Rate Amount


114 Supply, Installation testing &
commissioning of 55" Displays Duty Cycle-
24 x 7, UHD resolution, Smart Professional
Signage Display with system OS, IPS panel
technology, 500nits, 1100:1 Contrast Ratio,
24/7 operation, HDMI, DP, DVI-D, RS232,
LAN,USB, WiFI, Screen share, 8GB inbuilt
Memory,IP5X Dust Proof Certified Design,
Built-in Speakers, Narrow Bezel, Super
Sign CMS compatibity, with 1.1 Ghz Quad
Core CPU , Clear View with Non Anti
glare Coating etc as required.
1 Each 47890.74 47891.00
115 Supplying, installation testing and
commissioning of online single phase
500VA UPS system with 30 minutes
backup for protection of individual CCTV
switches at racks. 4 Each 17959.03 71836.00
C5 : LAN Networking System
116 Supply, Installation, Testing and
Commissioning of L2 24 port managable
switch of 10/100/1000 mbps speed PoE
ports of auto sensing type ethernet ports
and 24 x PoE+ ports,2 x 1 G SFP port,
switch etc complete as required.
1 Each 41305.76 41306.00
117 Supply, Installation, Testing and
Commissioning of 9 U wall mountable
rack 600mm (W) x 500mm (D) with power
Distribution Unit and Horizontial cable
Organiser (Closed type) with accessories. 1 Each 13310.81 13311.00
118 Supply, Installation, Testing and
Commissioning of 24 Port fully loaded
Patch panel suitable for mounting on
racks and for Cat 6A data cabling
including installation on existing rack/
surface of wall/ stand etc. complete as
required. 1 Each 11613.51 11614.00
119 Supply, Installation, Testing and
Commissioning of Cat 6A patch cords of 1
metre length. 24 Each 215.10 5162.00
120 Supply, Installation, Testing and
Commissioning of Cat 6A patch cords of 2
metre length. 7 Each 284.10 1989.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 334

S.No. Description Qty Unit Rate Amount


121 Supply and fixing of PoE Dual-Band WiFi 6
Wireless Access Points having coverage
area upto 2750 sq.ft with maximum speed
upto 3 Gbps suitable for fixing directly on
ceiling/wall complete with configuration,
tetsing and commissioning etc., complete
as required. 6 Each 22748.10 136489.00
122 Supply, installation, testing and
commissioning of wireless router (Wi-fi 6)
complete with all accessories etc., as
required. 1 Each 57468.88 57469.00
C6 : AV System
123 Supply, Installation, Testing &
Commissioning of 6.5-inch, 2 way, wall-
mount loudspeaker, LF Transducer - 6.5-
inch woofer with 1-inch voice coil or better,
HF Transducer-1-inch tweeter and 1-inch
voice coil or better, Rated impedance- 8Ω,
Transformer Taps- 70V/100V:30/15/7.5
Watts, Frequency Range-60Hz – 20kHz or
better, Rated RMS power-30 watts or
better, Sensitivity-86 dB SPL or better,
Coverage- 130° conical (500 Hz to 5 kHz) or
better, Maximum continuous SPL-101 dB
or better, Maximum peak SPL- 107 dB or
better, Grille - Powder coated steel or
similar, Enclosure - UV treated, high
impact ABS polymer or similar, Mounting
Brackets complete with connections etc., as
required. 4 Each 39063.35 156253.00
124 Supply, Installation, Testing &
Commissioning of Dual Channel Class-D
amplifier. Per Channel Power 60W @8Ω/4Ω
or better. Support for 70V/100V or more.
Power Sharing or Bridge/Parallel modes for
better power distribution. Frequency
Response- 20 Hz – 20 kH or better. Signal to
Noise ratio -> 102 dB or better, Input
impedance - >10k, balanced or unbalanced or
better, Front and Rear panel indicators for
Power, signal (per channel), limit / mute /
protect, etc. or better. Better to have Remote
standby and Power saving features - Auto-
standby complete as required. 2 Each 76605.46 153211.00
125 Supply, installation, testing and
commissioning of 6-channel analog sound
Mixer with number bus 2 & 9 faders, 3- band
EQ with a swept mid-on mono input, 2-band
EQ on stereo inputs 10- segment LED output
metering, XLR-type and 1/4″ metal jack
connector sockets etc., complete as required. 1 Each 57326.62 57327.00

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 335

S.No. Description Qty Unit Rate Amount


126 Supply, installation, testing and
commissioning of Wireless Hand Held
Cardioid condenser microphone with
receiver ,91 m (300 ft) Line of Sight, Audio
Frequency Response 50 to 15,000 Hz,Total
Harmonic Distortion, Ref. ±33 kHz deviation
with 1 kHz tone,0.5%, typical, Dynamic
Range100 dB, A-weighted, typical, etc.,
complete as required. 1 Each 42107.23 42107.00
127 Supplying and drawing of cable Fire
Retardant PVC insulated copper conductor
cable in the existing surface / recessed steel
conduit of following pairs, cores and size
including connections and interconnections
etc. as required.
127.1 Speaker cable Single pair, 2-core, 1.5 sq. mm 100 Mtr 57.42 5742.00
128 Supplying and fixing of following sizes of
steel conduit along with accessories in
surface/recess including painting in case of
surface conduit, or cutting the wall and
making good the same in case of recessed
conduit as required.
128.1 20 mm 90 Metre 237.12 21341.00
129 Supply, Installation, Testing and
Commissioning of 15 U wall mountable
rack 600mm (W) x 500mm (D) with Power
distribution unit, Horizontal cable Organiser
(Closed type), single fan with accessories.
For Audio & Video 1 Each 14247.50 14248.00
130 Supply, Installation, testing & commissioning
of not less than 218 cm Displays 440 nits
Brightness, Smart Android OS, 4K UHD
Resolution, 24*7, Screen Mirroring through,
Airplay/Chromecast, Direct LED, 16 Gb
storage, Wi-Fi, 178 Degree Viewing Angle,
Landscape/Portrait/Tilt Installation,
IP/RS232C Control, 10W+10W Speakers,
HDMI 2.1 (4), USB (2), Power Scheduling,
1200:1 Contrast Ratio, Color Gamut (DCI-P3)
92%, HDMI Auto, Wake up. 4K HDR Visual
Experience through 4K HDR Processor X1,
4K X-Reality PRO, Triluminos PRO,
Motionflow XR, HDR10/HLG/Dolby
Visiony and fixing of wall/ceiling mount
bracket, etc. complete as required. 1 Each 383610.43 383610.00
131 Supply and fixing of 4K 2.0 version HDMI
cable complete with connectors, etc. complete
as required. (5 meters length) 2 Each 9638.71 19277.00
Total 1,07,97,501

Contractor Executive Engineer

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE
PART D 336

Central Public Works Department


NIT. No10/2024-25/EE/Visakhapatnam

Name of Work: Construction of Indoor Stadium for National Centre for Indian Maritime
University, Vanagali (V), Sabbavaram (M), Visakhapatnam, A.P. including internal and
external water supply, sanitary installations, drainage, internal roads, UG sump, IEI & Fans,
Water Coolers, Split type AC units, Fire Fighting with Downcomer system, Addressable
Fire Alarm System, CCTV System, LAN System and AV system etc.
ABSTRACT OF COST
Name of the Contractor

Percentage % in Total Cost


Sl. Estimated above or Figures
Name of Component
No. Cost below the
estimated cost
1 Construction of Indoor Stadium
for National Centre for Indian
Maritime University, Vanagali
(V), Sabbavaram (M),
Visakhapatnam, A.P. including
internal and external water
supply, sanitary installations,
drainage, internal roads, UG
sump, IEI & Fans, Water Coolers,
Split type AC units, Fire Fighting
with Downcomer system,
Addressable Fire Alarm System,
CCTV System, LAN System and
AV system etc.
Civil component 5,68,68,888/-
Electrical component 1,07,97,501/-
GRAND TOTAL 6,76,66,389/-
Important Note:
1. The estimated cost of tender has been worked out by taking into consideration the cost
index of Visakhapatnam for DSR 2023 (Civil) &DSR 2022 (E&M) items and market
rates for NSR items; therefore, are adjusted accordingly.
2. The tenderer is to quote a single consolidated percentage only separately for Civil and
Electrical Component at par/above/below estimated cost to cover all the rates of all the
items under the schedule of composite tender.
3. If the percentage quoted is not clear, or if the rate is not quoted in percentage, the
tender shall be treated as invalid and will not be considered as lowest tenderer.

Contractor Executive Engineer

Cor NIL c Cor NIL Ins NIL


Omi NIL Ovw NIL

AE(P) EE