Installation and Operating Manual: Inverter TL
Installation and Operating Manual: Inverter TL
Operating Manual
I N V E R T E R T L
Thank you for buying a PLATINUM Inverter 13000 TL, 16000 TL,
19000 TL, 22000 TL.
In this instruction, we have compiled all information that is important
for installation and operation.
If you still have any trouble, please call our service hotline.
Service hotline
You can reach the PLATINUM service hotline as follows:
Phone +49 7522 73 777
Fax +49 7522 73 737
E-Mail service.platinum@diehlako.com
2 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.1 Warning notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2 Other symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Symbols on the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety and Dangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.1 Variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5 Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.1 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4 Mounting the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
5.5 Connection of the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1 Initial startup of inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.2 Phase Balancer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.3 Replacing devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.1 DC disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.2 Display and operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
7.3 Standard screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
7.4 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.5 Operating Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
7.6 Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
7.7 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
7.8 Error display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
8.1 Service Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
9.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
9.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
10 Placing out of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
10.1 Dismounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Installation and operating manual:PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 3
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12.1 Table of events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
13 Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
15 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
16 Manufacturers Warranty of Diehl AKO Stiftung & Co. KG. . . . . . . . . . . . . . . . . . . . . . . . . . 89
4 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Symbols
1 Symbols
1.1 Warning notices
Classification of warning notices
Signal words
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 5
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Symbols
1.3 Symbols on the product
6 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Safety and Dangers
3 Intended Use
 Use the inverter exclusively to feed photovoltaically converted
solar energy into the public 230 V/50 Hz mains.
 Do not use the inverter in autonomous power systems.
 Do not use the inverter in vehicles.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 7
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Function
4 Function
4.1 Variants
The PLATINUM line includes the following variants with different
power ranges (see 14 Technical Data):
Î PLATINUM 13000 TL
Î PLATINUM 16000 TL
Î PLATINUM 19000 TL
Î PLATINUM 22000 TL
Possible types:
Î wall-mounted device
Î free-standing device
Î free-standing device, outside
4.2 Options
Upgrades for an inverter or an inverter system:
Î Inverter networking via PLATINUM network (EIA 485 bus)
Î Optical and acoustical indicator (warning) devices.
Î Remote monitoring or remote readout with PLATINUM
WebMaster
Î Central display of systems with PLATINUM ViewMaster
Î Evaluation of system data with PLATINUM PV-Monitor
Î Remote control of AC power in connection with PLATINUM
PowerCommander, PLATINUM WebMaster and a control device
on the mains supply side.
8 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5 Mounting
5.1 Scope of delivery
Wall-mounted device:
Î PLATINUM inverter with protector
Î Mounting fixture
Î Installation and operating manual
Free-standing device:
Î PLATINUM inverter preassembled in Power Block protective
housing TL Large
Î Power Block protective housing
Î Protector
Î Installation and operating manual
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 9
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.2 Transport
2
Fig. 1 Transport with lifting gear
10 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.3 Unpacking
Unpacking the wall-mounted device
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 11
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Unpacking the free-standing device
1
Fig. 3 Unpacking the free-standing device
12 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.4 Mounting the inverter
DIEHL AKO advises against installing the inverter in living spaces. Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 13
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Protector
(1) Protector
For versions with protector, prior to installation of inverter:
 Hold protector 1 on bottom side and pull away from inverter.
14 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting of wall-mounted device
Mounting fixture
1 2
> 500
3
³ 525 1
³ 258
4
³ 208 ³ 204
5
> 500
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 15
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Inverter
> 500
> 500
³ 150 ³ 150 262
743
> 500
Fig. 6 Spacing for mounting of inverters (indications in mm)
16 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting of free-standing device
1
Fig. 7 Mounting of free-standing device
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 17
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.5 Connection of the inverter
Note Terms relating to the alternating voltage side will be combined with
AC below. Terms relating to the direct voltage side will be combined
with DC below.
18 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 19
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Terminal side
1 2
4 3 6 5 4 3 4 3
Fig. 8 Terminal side inverter
20 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
AC terminal
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL feed on Note
all three phases of the mains connection.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 21
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
6
7
1 2 3 4 5
Fig. 10 AC terminal
(1) PE
(2) N
(3) L1
(4) L2
(5) L3
(6) Release opening
(7) Cable input
To connect the cables:
 Use lines matching the type-dependent AC.
 Fuse lines accordingly.
Max. fuse: 40 A, C-characteristics.
 Stick screwdrive in release opening 6 and press release.
 Push cable into cable input 7 as far as it will go.
Ensure that no uninsulated cable parts are visible.
 Unlock release.
 Pull out screwdriver.
Note Clamp suitable for single-wire (rigid) lines with line diameter of 2.5 to
10 mm2 or multi-wire (flexible) lines with line diameter of 2.5 to
6 mm2.
22 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
To guarantee degree of protection IP65:
 Use a seal between cover and housing.
 Ensure that joint is undamaged.
 Ensure that no cables are trapped between cover and housing.
When the AC voltage connection is completed:
 Fixate AC cables with screw connection of bushing for AC
voltage connection cable.
 Close cover of AC voltage connection area.
 Fasten cover with screws.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 23
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
DC voltage connection
1 2 3 4 14 2 3 1 2 34
Fig. 11 DC voltage connection
(1) DC disconnector
(2) DC terminal -
(3) DC terminal +
(4) Fan
Note PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are
equipped with three MPP trackers working separately, with three
connection areas for direct voltage.
 Distribute strings of PV generator among the three areas so that
t there are the same module types with the same horizontal
orientation and vertical tilt and approximately the same DC
power connected in every area.
t there is no electrical connection between the three areas.
 Allocate DC connectors within the same area in pairs (+ and -).
24 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Connection to PLATINUM network
1 2 3 4 5
Fig. 12 Layout of network terminals
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 25
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Terminal strip connectors
1 2 3 4 5 6 7 8 9 10 11 12
Fig. 13 Layout of terminal strip connectors
26 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Connection for PLATINUM network (EIA 485)
1 2 1
Fig. 14 Network layout
(1) Termination option for engaging the terminating resistor
(2) PLATINUM network (EIA 485)
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 27
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
28 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting protector
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 29
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Locking protective cover
For the free-standing device for outside installation, a protective
cover provides additional protection from rain, sunlight and theft.
1 2
30 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 31
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
6 Start Up
Note Independent of demand, the inverter activates the fan as soon as
power input is started (e.g. every morning). When feeding in, the
inverter activates the fan as required.
During the startup, several basic settings such as language selection,
date and time settings are set. Information on display and operation
see 7.2 Display and operation.
Note In order to transfer all settings correctly, it is necessary to do one
complete startup.
If several inverters are installed which are networked via the EIA 485
interface, the startup can be carried out at any one of the installed
inverters (master programming). This inverter transmits the
configuration settings to all other inverters in the network. Every
inverter is automatically assigned a number at its initial startup. The
free allocation of this number is possible in a further step.
The inverters that are not used for input entries display other screen
contents depending on the menu. If no entry is possible, the inverter
shows the start screen.
Start screen
If any input has been entered in the inverter, the inverter shows the
start screen after a restart.
All inverters that are not operated during the configuration will show
the blocking screen.
32 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
After changing parameters, the inverter shows the following screen:
Key Function
OK Start configuration process with this inverter.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 33
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Language selection
Key Function
ST Select language.
OK Accept selected language.
After the configuration process has been started:
Î the inverter scans the network connected by the EIA485-Bus for
other inverters.
Î all inverters connected to the network are blocked.
EIA485 bus
As long as the network scan (Scanning Network) is still in process,
the display shows the following screen:
When the network scan is completed, the display shows the number
of detected bus participants. In case of a single inverter, the display
shows 01.
34 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The network scan can only recognize more than 1 inverter if the Note
inverters are correctly networked via the EIA 485 interface.
If one or several inverters have been replaced or not all inverters are Note
numbered correctly, this can be corrected (see 6.3 Replacing
devices).
Inverter numbering
It is possible to network several inverters via the EIA 485 interface.
Inverter numbers are allocated automatically during the network
scan. The inverter number is displayed in the lower left corner of the
screen.
For a clearer overview, the inverters can be re-numbered for specific
requirements. For instance, the inverter number can be defined
according to the installation sequence.
With three inverters installed, the left-hand one is allocated the no. 1, Example
the middle one no. 2 and the right-hand one no. 3.
The following screen is not displayed if only one inverter is Note
configured.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 35
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Screen Inverter numbering:
Key Function
WX YES = Allocate user-defined number to inverter.
NO = Accept inverter number unchanged.
OK Confirm selection.
If NO was selected:
Î The inverter adopts the displayed number und switches to the
Settings Date screen.
Note The following screen is not displayed if only one inverter is started up.
Key Function
OK The inverter adopts the next available number.
Example As soon as the OK key was pressed at the first inverter, this inverter is
allocated no. 1, which is shown on the display. When the OK key was
pressed at the second inverter, this inverter is allocated no. 2, etc..
36 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The following screen is not displayed if only one inverter is started up. Note
Key Function
ST Select country.
OK Accept selection.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 37
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
After the transmission is successfully completed, the inverter shows
the selected country setting.
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept date setting.
38 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Time
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept time setting.
Changing date or time can result in overwriting saved data or cause Note
gaps in data recording.
To reset time:
 Select BACK.
 Press OK key.
After setting the time, the configuration (language, date and time) are
automatically transferred to all other inverters in the network (if
available).
After the data transmission, the inverter will show the menu Time
settings (see 7.6 Settings).
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 39
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
6.2 Phase Balancer
An unbalanced load ist he difference between the nominal AC power
on the three mains phases.
The energy provider and the power plant operator determine the
admissible maximum unbalanced load for the installation of inverters
on different phases of the supply mains.
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are
equipped with three inverter modules, each of which feeds AC power
on a mains phase.
The Phase Balancer function makes sure that the admissible
maximum unbalanced load is not exceeded.
Î Failure of an inverter module
Î different AC powers occurring in dependence of the load
It is possible to set the admissible maximum power (unbalanced load)
and the reaction time according to the specifications of the power
plant operator (see 8.1 Service Menu).
40 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
To accept device numbers of replaced inverters:
 Select EXCHANGE INVERTER.
To renumber:
 Select REASSIGN NUMBERS.
Replacement of devices
After EXCHANGE INVERTER was selected, the replaced inverters
show the following screen:
Key Function
WX Select device number.
OK Accept selected device number.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 41
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Inverter is added to PLATINUM network.
Inverter shows main menu.
Inverter shows device number of the replaced device in the lower left
corner.
Reassign numbers
 Reassign numbers see 6.1 Initial startup of inverter.
42 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7 Operation
7.1 DC disconnector
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL have a Note
separate DC disconnector at each of the three DC inputs.
The DC disconnector enables switching on and off the solar generator.
To engage the solar generator:
 Set DC disconnector to 1 for all three connection areas.
To switch off the solar generator:
 Set DC disconnector to 0 for all three connection areas.
DIEHL AKO recommends to actuate the DC disconnector once a year Note
to prevent the welding of contacts.
DIEHL AKO recommends to switch off the mains voltage (AC) before
switching off the DC disconnector to minimize wear and tear of the
contacts.
1
Fig. 19 DC disconnector
(1) DC disconnector
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 43
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.2 Display and operation
Note If there is no input for approx. 2 minutes, inverter switches to
standard display during feed.
1 2 3 4 3 5 6
12
11
10
9 8 7
Fig. 20 Display and operation
(1) Time
(2) LED red
(3) Scroll arrows horizontal
(4) Title
(5) LED green
(6) Date
(7) OK key
(8) Navigation keys
(9) ESC key
(10)Device number
(11)Scroll arrows vertical
(12)Day
44 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Time
Time display in 24-hour format.
LEDs
Two LEDs indicate the operating status of the inverter.
Both LEDs blinking indicate that the inverter is performing a network Both LEDs
scan.
Scroll arrows
The menu contains other menu items.
 Navigate using keys T and S or W and X.
Title
Title of the selected menu.
Date
Date display in formats DD.MM.YY, MM.DD.YY oder YY.MM.DD.
Adjustable in menu Time settings.
Keys
The functions of the keys are indicated in the tables under the
illustrations.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 45
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Device number
Displays the inverter number.
Day
Displays the day of the week.
Key Function
WX Navigate within the display period.
ST Switch to screen Current.
ESC Call up Main Menu.
Key Function
ST Navigate within menu.
OK Call up selected menu.
46 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.5 Operating Display
The operating display shows a list of physical values and a
corresponding evaluation graph. Type and value of the displayed
physical value depend on the selected period. The illustration below
shows an example for the period TODAY.
Key Function
WX Navigate within the display period.
ST Switch to menu Current.
ESC Back to Main Menu.
Units:
Î W: feed power
Î kWh or MWh: feed power for the indicated period
Î EUR: rebate for the indicated period (Adjustable in menu
Settings.)
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 47
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Current
Screen Current shows the distribution of the current power to the
individual inverter modules.
Î Bar frame displays maximum power of respective inverter.
Î Bar content displays current power of respective inverter.
Key Function
S Call up screen Operating Display.
T Call up screen Current Phase 1.
ESC Back to Main Menu.
48 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Key Function
S Call up screen Current.
T Call up screen Current Phase 2.
ESC Back to Main Menu.
Key Function
S Call up screen Current Phase 1.
T Call up screen Current Phase 3.
ESC Back to Main Menu.
Key Function
S Call up screen Current Phase 2.
T Call up screen Operating Display.
ESC Back to Main Menu.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 49
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Physical values
Display period
The following display periods can be selected:
Î Today
Î Yesterday
Î Current week
Î Previous week
Î Current month
Î Previous month
Î Current year
Î Previous year
Î Since startup
Note The values displayed by the inverter may differ from the readings of
calibrated electricity meters.
1 2
(1) Physical values
(2) Graphic of physical value
50 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Physical values:
t Designation of the physical value
t Current value ( )
t Peak value ( )
t Cumulative value ( )
Type and value of the displayed physical value depend on the selected Note
period.
Graphic: For the display periods TODAY and YESTERDAY, the
progress of the feed power is displayed. For all other display periods
the feed energy per time interval is displayed.
Table: For the display period TODAY, the current power value is
displayed. For all other periods, the maximum value is displayed.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 51
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.6 Settings
In the menu Settings the following settings are possible:
Î Time settings
Î Language
Î Alarm volume
Î Alarm contact function
Î LCD
Î Rebate
Î System
Î Energy meter
Key Function
ST Navigate within menu.
ESC Back to Main Menu.
OK Call up selected menu.
Time settings
In the menu Time settings, the following settings are possible:
Î Date
Î Time
Î Date format
Î Daylight saving time
Key Function
ST Navigate within menu.
ESC Back to menu Settings.
OK Call up selected menu.
52 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Date
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept date setting.
Time
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept time setting.
Changing date or time can result in overwriting saved data or cause Note
gaps in data recording.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 53
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
To not accept time setting:
 Select CANCEL.
 Press OK key.
Date format
Key Function
ST Select format.
OK Confirm format.
ESC Return to menu Time setting.
Daylight saving
time
Key Function
ST Navigate within menu.
OK Confirm selection.
ESC Return to menu Time setting.
MANUALLY
Î Manual setting of daylight saving time required.
AUTOMATIC
Î Inverter sets daylight saving time automatically, depending on set
country and calendar.
54 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
If the MANUALLY option is selected, the following screen will appear
the next time the date or time is set:
Key Function
ST Increase or reduce alarm volume.
ESC Back to menu Settings.
OK Accept alarm volume setting.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 55
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Alarmkontakt
Key Function
ST Navigate within menu.
ESC Back to menu Settings.
OK Accept setting.
OFF
Î The alarm contact (NO contact) is constantly open if a safety-
relevant or blocking error occurs.
Î Alarm contact deactivated.
INTERVAL
Î The alarm contact (NO contact) opens and closes periodically if a
safety-relevant or blocking error occurs.
CONTINUOUS
Î If a safety-relevant or blocking error occurs, the alarm contact
(NO contact) is constantly closed until the error is remedied.
TEST
Î Close alarm contact temporarily while selecting a menu item.
56 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
LCD
Key Function
ST Increase or reduce contrast or brightness.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.
Feed payback
Key Function
CURRENCY Currency in which the rebate is displayed.
VALUE/KWH Value for 1 kWh feed current (for rebate calculation).
ST Increment or decrement present digit.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.
If the inverters are connected to the PLATINUM network, the input of Note
the value for the rebate is only necessary in one inverter. After the
input is finished, the value is automatically transferred to all other
inverters.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 57
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
System
Key Function
ST Increment or decrement present digit.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.
Energy meter
The energy meter enables the metering of energy and operating hours
since the start of the inverter or since a reset of the energy meter.
Key Function
BACK Back to menu Settings.
RESET Set energy meter to 0.
WX Select BACK or RESET.
OK Confirm selection.
ESC Back to menu Settings.
58 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.7 Information
The menu Information shows the following information:
Î Operating data
Î System data
Î Inverter type
Î Inverter version
Î Event information
Key Function
S Call up screen Inverter version.
T Call up screen System data.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
GENERAL
Î Shows feed data of the inverter since the startup.
Î Resetting is not possible.
METER 2
Î Shows feed data of the inverter since the latest reset of meter 2.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 59
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
System data
Key Function
S Call up screen Operating data.
T Call up screen Inverter type.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
NAME
Î Shows the name of the PV system.
NO. OF PARTICIPANTS
Î Indicates number of network participants (e. g. inverter and
monitoring devices such as PLATINUM PV-Monitor, PLATINUM
ViewMaster and PLATINUM Webmaster).
NO. OF INVERTERS
Î Shows the number of inverters in the network.
60 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Inverter type
Key Function
S Call up screen System data.
T Call up screen Inverter version.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
TYPE
Î Indicates inverter type.
S/N
Î Indicates inverter serial number.
When contacting the PLATINUM service, have the serial number Note
ready.
After changing the inverter network parameters, the display indicates
USER-DEFINED NETWORK MONITORING..
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 61
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Inverter version
Key Function
S Call up screen Inverter type.
T Call up screen Operating data.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
FIRMWARE
Î Shows the inverter firmware version.
HARDWARE
Î Shows the inverter hardware version.
EIA485
Î Shows the data bus software version.
BL
Î Shows version of bootloader software.
62 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.8 Error display
The error displays are meant for the user. Any detected errors are
displayed with a slight delay. In case of an error, the inverter displays
the error type and error code. Error causes and measures
see 12 Troubleshooting.
Fatal errors
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 63
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Blocking errors
64 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Non-blocking errors and warnings
Key Function
OK Clears the error display
ESC Leave error display.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 65
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
8 Service
8.1 Service Menu
The menu Service offers the following information and functions:
Î display event list
Î display parameters
Î set max. unbalanced load (Phase balancer)
Î Reconfiguration
Î display startup date
Î display feed meter
Key Function
ST Navigate within menu.
ESC Return to standard display.
OK Call up selected menu.
66 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Event list
Key Function
ST Navigate within the event list.
ESC Return to menu Service.
Columns:
Î 1. column: Event no.
Î 2. column: If available, designation of unit within inverter
Î 3. column: Event date
Î 4. column: Event time
Î 5. column: Event code
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 67
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Parameters
In some supply areas, the values for supply voltage and frequency
may differ temporarily or permanently from the factory settings. It is
possible to adapt the PLATINUM inverter to these values. Contact the
PLATINUMservice for this.
The screens Parameters show the valid ENS type and the currently
set parameters such as start time, minimum and maximum values of
frequency and voltage with the respective reaction times.
The parameters can exclusively be modified by certified persons with
the PLATINUM service tool.
Version Screen Version shows information on inverter type.
Key Function
S Return to menu Service.
T Call up screen Frequency Limits.
ESC Back to menu Main Menu.
68 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Screen Frequency Limits shows: Frequency limits
Î set frequency limits
Î switch-off times for exceeding or falling below frequency limits
Key Function
S Call up screen Version.
T Call up screen Voltage Limits.
ESC Back to menu Main Menu.
Key Function
S Call up screen Frequency Limits.
T Call up screen Mains Quality.
ESC Back to menu Main Menu.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 69
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Mains quality Screen Mains Quality shows information on mains quality.
Key Function
S Call up screen Voltage Limits.
T Call up screen Fault Current.
ESC Back to menu Main Menu.
Key Function
S Call up screen Mains Quality.
T Call up screen Fault Current.
ESC Back to menu Main Menu.
70 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Key Function
S Call up screen Fault Current.
T Call up screen Limits.
ESC Back to menu Main Menu.
Key Function
S Call up screen Fault Current.
T Call up screen Version.
ESC Back to menu Main Menu.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 71
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Phase Balancer
It is possible to set the admissible maximum power (unbalanced load)
and the reaction time according to the specifications of the power
plant operator.
Operating mode
Key Function
ST Select operating mode.
ESC Back to menu Main Menu.
OK Accept selected operating mode.
OFF
Î Switch off Phase Balancer function.
Î No limit of unbalanced load.
POWER CONTROL
Î Switch on Phase Balancer function.
Î The inverter monitors and limits the difference between AC
powers.
ERROR OFF
Î If one inverter module fails, the inverter will disconnect the other
modules from the mains.
ERROR REDUCE
Î If one inverter module fails, the inverter limits the AC power of the
other modules to the set unbalanced load.
72 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
admissible
maximum
power
(unbalanced load)
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
ESC Back to menu Main Menu.
OK Accept setting.
Range of values:
Î 200 W to 9,999 W
Factory setting:
Î 5,000 W
Reaction time
Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
ESC Back to menu Main Menu.
OK Accept setting.
Range of values:
Î 10 s to 9,999 s
Factory setting:
Î 300 s
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 73
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
If the inverter is connected in the PLATINUM network, all parameters
and the Phase Balancer settings are transferred to the other inverters
of the PLATINUM network after the reaction time has been confirmed.
During the transfer, the inverter shows the following screen.
Reconfiguration
Inverter shows screen Start initial startup (see 6.1 Initial startup of
inverter).
Note A reconfiguration of the country is only possible within the first four
hours after the connection. Afterwards, this menu item is blocked.
74 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Startup
Key Function
OK Return to menu Service.
ESC Return to menu Service.
Meter
Key Function
OK Return to menu Service.
ESC Return to menu Service.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 75
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Maintenance
9 Maintenance
Danger to life due to electric shock!
 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
DIEHL AKO.
Danger
9.1 Maintenance
The inverter is maintenance-free.
76 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Maintenance
9.2 Cleaning
In a dusty environment:
 Check fan and cooling elements regularly and clean them if
necessary.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 77
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
78 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Dismount the inverter as follows:
 Lift the inverter up and out of the mounting fixture.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 79
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Packing up the wall-mounted device
80 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Packing up the free-standing device
1
Fig. 22 Packing up the free-standing device
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 81
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Disposal
11 Disposal
12 Troubleshooting
12.1 Table of events
To isolate the error, have the following information ready when calling
Service:
Î displayed error number (No.)
Î serial number of the inverter (see 7.7 Information)
82 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Troubleshooting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 83
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Troubleshooting
84 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Standards and Approvals
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 85
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Technical Data
14 Technical Data
Input characteristics 13000 TL 16000 TL 19000 TL 22000 TL
Maximum PV power 14,700 Wp 18,000 Wp 21,300 Wp 24,300 Wp
Maximum DC power 12,900 W 15,900 W 18,900 W 21,600 W
PV-voltage range, MPPT 351 – 710 V 349 – 710 V 350 – 710 V 351 – 710 V
Maximum DC voltage 880 V
Maximum input current 3 x 13.0 A 3 x 16.0 A 3 x 18.5 A 3 x 21.0 A
Number of string inputs 6 6 9 9
Number of MPP trackers 3
DC section switch device DC disconnector, integrated in the appliance
Reverse battery protection yes
Output characteristics
Nominal AC power rating 11,250 W 13,800 W 16,550 W 18,900 W
Nominal AC-intensity 3 x 16.3 A 3 x 20.0 A 3 x 23.9 A 3 x 27.4 A
Maximum AC power 12,360 W 15,000 W 18,000 W 20,700 W
Maximum AC intensity 3 x 17.9 A 3 x 21.7 A 3 x 26.1 A 3 x 30.0 A
Feed operation starts at 7W 7W 7W 8W
Mains output voltage range 3 x 230 V (+/-20%) feeding on three phases
Internal consumption at night below 6 W
Mains frequency 47.5 Hz – 52.2 Hz
Short-circuit proof yes
Interfaces
DC input DC plug, Multicontact MC3, MC4, Tyco
AC output Spring clamp connectors
PLATINUM network EIA 485, 2x RJ45 Western Modular add. plug connector with
terminal screws
Service interface EIA 232, SubD 9-pole socket
Potential-free contact Change-over contact, maximum 24 V AC/2 A, plug connector with
terminal screws
Appliance data
Maximum degree of efficiency 97.3% 97.4% 97.7% 98.0%
European efficiency 96.8% 96.8% 97.3% 97.6%
Weight 81 kg 84 kg 87 kg 87 kg
86 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Technical Data
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 87
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
EC Declaration of Conformity
15 EC Declaration of Conformity
Issuer’s name and Diehl AKO Stiftung & Co. KG
address: Pfannerstraße 75
D-88239 Wangen im Allgäu, Germany
Product Solar inverter
designation:
Type designation: PLATINUM 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
PLATINUM 13000 TL, 16000 TL, 19000 TL, 22000 TL
The designated devices comply with the provisions of EU directives.
Especially the Low Voltage Directive 2006/65/EG and the EMC
directive 2004/108/EG.
The designated devices conform to the following norms:
Î DIN EN 50178: 1998-04
Î DIN EN 61 000-3-2: 2006-10
Î DIN EN 61 000-3-12: 2005-09
Î DIN EN 61 000-3-3: 1994 / A2: 2005
Î DIN EN 61 000-3-11: 2001-04
Î DIN EN 61 000-6-2: 2006-03
Î DIN EN 61 000-6-3: 2007-09
Consequently the products mentioned above carry the CE mark.
Furthermore, we declare that the products mentioned above comply
with the prescriptions of the VDEW (German Electricity Industry
Association) that apply to solar inverters according to the “Directive
for the Connection and Parallel Operation of Energy Generation
Equipments in the Low-Voltage Mains”.
88 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 89
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
66 months after the manufacturing date of the Warranted Product, as
stated on the type plate of the Warranted Product. For Warranted
Products repaired or replaced by Diehl AKO, the manufacturer’s
warranty expires with the end of the original Warranty Period. Legal
and/or contractual warranty claims of any kind, which arise during a
statutory or contractual warranty period, can not be derived from this
manufacturer’s warranty.
Any claims based on the manufacturer’s warranty must be asserted
in writing by the Warranted User to Diehl AKO within the Warranty
Period. Such warranty claims can be submitted through an authorized
specialist retailer, wholesaler or specialist installation company, or
through MATRIX Power Systems GmbH.
6. Rights under the manufacturer’s warranty – Damage and costs
not covered
If a defect of the Warranted Product occurs during the Warranty
Period and if Diehl AKO is responsible for this defect and if this defect
impairs or reduces the functionality of the Warranted Product to a
significant extent, Diehl AKO will choose to carry out either free-of-
charge repairs or free-of-charge replacement of the Warranted
Products with a product that offers at least the same or the same type
of functionality and performance.
Such repairs or replacement will be carried out only at the Diehl AKO
factory. Transport to Diehl AKO must be in the original packaging or
other packaging that is at least of the same quality as the original
packaging. If the Warranted user requests repair or replacement at a
site other than the Diehl AKO factory, Diehl AKO can agree to this
request. In this case, however, the Warranted User will bear any
travel costs and additional labor costs according to DIEHL AKO
standard rates.
Any claims from the manufacturer’s warranty beyond free-of-charge
repair or free-of-charge replacement are ruled out, especially any
claims on compensation for defect-related capital damage, e.g. loss
of profit including compensation for lost power feeds, costs of
installation and de-installation, costs of fault diagnostics, recall costs
and interruption to production processes.
If no defect is found in the Warranted Product sent in for repair or
replacement, or if there is no claim based on the manufacturer’s
warranty for any other reason, Diehl AKO may demand from the
Warranted User an administration fee (flat rate per product) plus the
costs of transport back to the Warranted User.
Any claims based on this manufacturer’s warranty expire 6 months
after occurrence of the fault, but not later than 3 months after the end
of the Warranty Period.
90 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
7. Exclusion cases
Any claims of the Warranted User are excluded in the following
cases:
Î Improper use
Î Unprofessional or incorrect installation, installation not complying
to standards, or installation not following the installation
directions or instructions provided by Diehl AKO
Î Unprofessional or incorrect operation and use, or operation and
use against the operating directions or instructions provided by
Diehl AKO
Î Operation with defective protective systems
Î Any unauthorized modifications or repairs
Î Use of replacement parts and accessories non-compliant with the
original Diehl AKO specifications
Î Failure to perform continuous maintenance according to the
maintenance directions and instructions provided by Diehl AKO
Î Removal, damage or destruction of the sealing or the type plate
installed by Diehl AKO or MATRIX Power Systems
Î Foreign-body influence and force majeure
Î Non-compliance with applicable safety regulations
Î Transport damage
Î Lightning damage
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 91
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
9. General provisions
Claims by the Warranted User based on this manufacturer’s warranty
can only be transferred to third parties with prior written consent of
Diehl AKO.
Should any clause of this manufacturer’s warranty be or become
void, all other stipulations of the manufacturers warranty remain in
force. In place of the clause that is or has become void, a valid clause
is automatically regarded as agreed. The replacement clause will be
as close as possible to the voided clause in its economic substance.
The same rule applies to any missing clause in this agreement.
This manufacturer’s warranty is subject only to the laws of the
Federal Republic of Germany, excluding the stipulations of Private
International Law and the UN Convention on the International Sale of
Goods.
The exclusive place of jurisdiction in case of any conflict arising from,
or in connection with this manufacturer’s warranty, is Wangen im
Allgäu/FRG.
92 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Diehl AKO Stiftung & Co.KG
Pfannerstraße 75
D-88239 Wangen
Fon: +49 7522 73 700
Fax: +49 7522 73 710
Mailto: platinum@diehlako.com
www.diehlako.com
Service
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75 Tel.:+49 7522 73 777 Mailto:service.platinum@diehlako.com
D-88239 Wangen Fax+49 7522 73 737 www.diehlako.com