You are on page 1/ 94

Installation and

Operating Manual

I N V E R T E R T L

Mat. No. 737 576-AB, Version 05/2010


Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL

Thank you for buying a PLATINUM Inverter 13000 TL, 16000 TL,
19000 TL, 22000 TL.
In this instruction, we have compiled all information that is important
for installation and operation.
If you still have any trouble, please call our service hotline.

Service hotline
You can reach the PLATINUM service hotline as follows:
Phone +49 7522 73 777
Fax +49 7522 73 737
E-Mail service.platinum@diehlako.com

2 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL

1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.1 Warning notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2 Other symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Symbols on the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety and Dangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.1 Variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5 Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.1 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4 Mounting the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
5.5 Connection of the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1 Initial startup of inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.2 Phase Balancer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.3 Replacing devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.1 DC disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.2 Display and operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
7.3 Standard screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
7.4 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.5 Operating Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
7.6 Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
7.7 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
7.8 Error display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
8.1 Service Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
9.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
9.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
10 Placing out of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
10.1 Dismounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Installation and operating manual:PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 3
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL

11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12.1 Table of events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
13 Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
15 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
16 Manufacturers Warranty of Diehl AKO Stiftung & Co. KG. . . . . . . . . . . . . . . . . . . . . . . . . . 89

4 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Symbols

1 Symbols
1.1 Warning notices
Classification of warning notices

The warning notices differentiate between three types of dangers


indicated by the following signal words:
Î Caution warns of material damage.
Î Warning warns of bodily harm.
Î Danger warns of a danger to life.

Layout of the warning notices

Type and source of the danger!


 Action to avoid the danger.

Signal words

1.2 Other symbols


Instructions
Layout of instructions:
 Instruction to do something.
Result of the action, if necessary.
Lists

Layout of bulleted lists:


Î List level 1
t List level 2

Layout of numbered lists:


1. List level 1
2. List level 1
2.1 List level 2
2.2 List level 2

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 5
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Symbols
1.3 Symbols on the product

6 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Safety and Dangers

2 Safety and Dangers


 Use inverters according to their intended use.
 Use inverters in original and technically fully intact condition
without unauthorized modifications.
 Ensure that inverters are installed and serviced by qualified
specialists only.
t The qualified specialist personnel requires a license from the
relevant energy suppliers.
 Always mount inverters in a vertical position.
 Ensure that all protection devices are fully operational.
 Verify that ventilation openings are not blocked or covered.
 Protect inverters from direct sunlight.
 Prior to installation and maintenance work, make certain that the
inverter is de-energized.
 Ensure that regulations stipulated by trade associations and
inspection authorities and agencies are observed and that the
connection conditions of the relevant energy supplier or
equivalent national and international rules and regulations are
adhered to.
 Observe conditions of use (see 14 Technical Data).

3 Intended Use
 Use the inverter exclusively to feed photovoltaically converted
solar energy into the public 230 V/50 Hz mains.
 Do not use the inverter in autonomous power systems.
 Do not use the inverter in vehicles.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 7
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Function

4 Function
4.1 Variants
The PLATINUM line includes the following variants with different
power ranges (see 14 Technical Data):
Î PLATINUM 13000 TL
Î PLATINUM 16000 TL
Î PLATINUM 19000 TL
Î PLATINUM 22000 TL
Possible types:
Î wall-mounted device
Î free-standing device
Î free-standing device, outside

4.2 Options
Upgrades for an inverter or an inverter system:
Î Inverter networking via PLATINUM network (EIA 485 bus)
Î Optical and acoustical indicator (warning) devices.
Î Remote monitoring or remote readout with PLATINUM
WebMaster
Î Central display of systems with PLATINUM ViewMaster
Î Evaluation of system data with PLATINUM PV-Monitor
Î Remote control of AC power in connection with PLATINUM
PowerCommander, PLATINUM WebMaster and a control device
on the mains supply side.

8 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting

5 Mounting
5.1 Scope of delivery
Wall-mounted device:
Î PLATINUM inverter with protector
Î Mounting fixture
Î Installation and operating manual

Free-standing device:
Î PLATINUM inverter preassembled in Power Block protective
housing TL Large
Î Power Block protective housing
Î Protector
Î Installation and operating manual

Free-standing device, outside:


Î PLATINUM inverter with protector preassembled in Power Block
protective housing with protective cover and protective grate
Î Installation and operating manual

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 9
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.2 Transport

Danger to life due to inverter dropping from the wall!


 Transport packaged inverter exclusively with a forklift
truck and on a transport pallet.
 Do not tilt inverter.
Danger
 Transport inverter exclusively with lifting gear.

Transport with lifting gear


 Load thread on inverter exclusively in longitudinal direction.
 Ensure that carrying straps or ropes are at least 2 m long.
- or -
 Use yoke.
1

2
Fig. 1 Transport with lifting gear

(1) Threaded holes for transport eyebolts


(2) Recessed grip

 Screw DIN 580 M10 eyebolts into threaded holes 1 on inverter.


 Fasten lifting gear on eyebolts.

Note Eyebolts are not included in delivery.

10 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.3 Unpacking
Unpacking the wall-mounted device

Fig. 2 Unpacking the wall-mounted device

(1) Upper part of packaging


(2) Wooden protection elements
(3) Bottom part of packaging
(4) Transport pallet

 Put transport pallet 4 with inverter on even ground.


 Remove upper part of packaging 1.
 Lift inverter out of bottom part of packaging 3.
Use wooden protection elements 2 for carrying.
 Take inverter to installation site.
On installation site:
 Unscrew wooden protection elements 2 from inverter.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 11
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Unpacking the free-standing device

1
Fig. 3 Unpacking the free-standing device

(1) Transport pallet

 Take inverter to installation site on transport pallet 1.


 Put transport pallet with inverter on even ground.
 Remove plastic protective packaging.
 Put inverter on intended installation site.

12 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.4 Mounting the inverter

Danger to life due to electric shock!


 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
DIEHL AKO.
Danger

Danger to life due to incorrect connection of inverter!


 Have inverters installed by qualified specialists only.
The qualified specialist personnel requires a license
from the relevant energy suppliers.
Danger

Danger to life due to inverter dropping from the wall!


 Use mounting elements appropriate for the mounting
wall and the weight of the inverter unit.
During mounting and dismounting:
Danger
 Wear protective shoes.
 Ensure a stable position.

Material damage due to unprotected installation site!


 Observe admissible ambient temperature.
(see 14 Technical Data).
Caution

Material damage due to excessive dust formation!


 PDegree of protection IP65 does not apply to
communication interface.
 Avoid excessive dust formation.
Caution
 Avoid dust formation with electrically conductive dust
particles.

DIEHL AKO advises against installing the inverter in living spaces. Note

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 13
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Protector

Fig. 4 Removing protector

(1) Protector
For versions with protector, prior to installation of inverter:
 Hold protector 1 on bottom side and pull away from inverter.

14 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting of wall-mounted device

Mounting fixture
1 2

> 500
3
³ 525 1
³ 258
4

³ 208 ³ 204

5
> 500

Fig. 5 Spacing for position of mounting fixture (indications in mm)

(1) Mounting fixture


(2) Ventilation openings
(3) Slotted piece for mounting bolts
(4) Mounting bolts
(5) Grip moldings
Install the mounting fixture as follows:
 Unscrew mounting fixture 1 from the back of the inverter.
 Mark the mounting holes using the mounting fixture as a
template.
t Observe dimensions and distances.
t Observe a minimum distance of 50 cm between inverter and
floor.
t Observe a minimum distance of 50 cm between inverter and
ceiling.
 Drill the mounting holes and insert the screw anchors.
 Bolt down mounting fixture 1.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 15
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Inverter

> 500

> 500
³ 150 ³ 150 262

743

> 500
Fig. 6 Spacing for mounting of inverters (indications in mm)

Mount inverters as follows:


 Observe a minimum distance of 50 cm to the floor.
 Observe a minimum distance of 50 cm to the ceiling.
 Slide cooling element of the inverter into the mounting fixture 1.
 Hold the inverter on recessed grips 5 and push up until mounting
bolts 4 drop into slotted pieces for mounting bolts 3 on both
sides.
 Let down the inverter.
Mounting bolts 4 are seated in the slotted pieces.
 Verify that minimum distances are kept (see Fig. 6).
 Verify that the inverter is hanging in the mounting fixture
correctly.

16 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting of free-standing device

1
Fig. 7 Mounting of free-standing device

(1) Power Block protective housing TL Large

 Put inverter in intended position.


 Secure inverter against toppling over and shifting with screws in
base of Power Block protective housing TL Large 1.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 17
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
5.5 Connection of the inverter
Note Terms relating to the alternating voltage side will be combined with
AC below. Terms relating to the direct voltage side will be combined
with DC below.

Danger to life due to high AC voltage!


 Switch off the mains power supply (AC side) before
connecting the inverter (fuse).
 Connect inverter exclusively to TN or TT mains
Danger
(see IEC 60364-1) with 230 V.
 Maximum allowed fuse on alternating voltage side:
40 A, C-characteristics.

Danger to life due to high DC voltage!


 Prior to connecting the inverter, verify that voltage is
applied to the generator-side DC terminal.
 Prior to connecting the inverter, verify that the DC
Danger
voltage polarity is correct.
 Wear insulating protective clothing and face
protection if there is voltage present at the DC input.
 Remove DC cable exclusively if inverter is out of
operation.

Risk of burns due to hot surfaces!


After a longer operation with high power, housing
temperatures of > 60 °C are possible.
 Do not touch hot surfaces.
Caution

Material damage due to DC plug connectors that don’t


fit!
 Use exclusively DC cable connectors and DC
receptacles of the same type and manufacturer.
Caution
 Make sure that cable connector in latched in socket
correctly.

18 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting

Lack of performance and functionality due to


inappropriate cables!
 Ensure that wire cross sections and fuses conform to
VDE 100 Part 430.
Caution
 Ensure that any network cables between two
inverters are not longer than 30 m.
 Ensure that network cable of entire PV plant is not
longer than 1,000 m.
 For DC lines, use a wire cross section of at least
2.5 mm2.
 Ensure that admissible power dissipation of mains line
is not exceeded.

Material damage due to excessive voltage!


 Ensure that the max. DC voltage is not exceeded
(see 14 Technical Data).
 Connect exclusively safety extra low voltage on the
Caution
contact of the external indicator.

For free-standing devices, the possibilities for cable routing through


Power Block protective housing TL Large are as follows:
Î from front
Î from below
Î from back

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 19
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Terminal side

1 2

4 3 6 5 4 3 4 3
Fig. 8 Terminal side inverter

(1) Control unit


(2) Holder for installation and operating manual
(3) Fan
(4) Switch knob DC disconnector
(5) Cover of AC voltage connection
(6) Bushing for AC voltage cable
(7) Type plate

20 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
AC terminal

Creation of inadmissibly high unbalanced load!


AC power varies along with DC power.
 Observe maximum admissible unbalanced load of AC
side.
Caution

PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL feed on Note
all three phases of the mains connection.

Fig. 9 Cover of AC voltage connection

(1) Mounting screws for cover


(2) Cover of AC voltage connection
Establish AC voltage connection as follows:
 Loosen mounting screws 1.
 Open cover of AC voltage connection area 2.
 Put cable through bushing for AC voltage connection cable.
Suitable for cable diameters between 12 and 21 mm. Note

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 21
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting

6
7

1 2 3 4 5
Fig. 10 AC terminal

(1) PE
(2) N
(3) L1
(4) L2
(5) L3
(6) Release opening
(7) Cable input
To connect the cables:
 Use lines matching the type-dependent AC.
 Fuse lines accordingly.
Max. fuse: 40 A, C-characteristics.
 Stick screwdrive in release opening 6 and press release.
 Push cable into cable input 7 as far as it will go.
Ensure that no uninsulated cable parts are visible.
 Unlock release.
 Pull out screwdriver.

Note Clamp suitable for single-wire (rigid) lines with line diameter of 2.5 to
10 mm2 or multi-wire (flexible) lines with line diameter of 2.5 to
6 mm2.

22 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
To guarantee degree of protection IP65:
 Use a seal between cover and housing.
 Ensure that joint is undamaged.
 Ensure that no cables are trapped between cover and housing.
When the AC voltage connection is completed:
 Fixate AC cables with screw connection of bushing for AC
voltage connection cable.
 Close cover of AC voltage connection area.
 Fasten cover with screws.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 23
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
DC voltage connection

1 2 3 4 14 2 3 1 2 34
Fig. 11 DC voltage connection

(1) DC disconnector
(2) DC terminal -
(3) DC terminal +
(4) Fan

Note PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are
equipped with three MPP trackers working separately, with three
connection areas for direct voltage.
 Distribute strings of PV generator among the three areas so that
t there are the same module types with the same horizontal
orientation and vertical tilt and approximately the same DC
power connected in every area.
t there is no electrical connection between the three areas.
 Allocate DC connectors within the same area in pairs (+ and -).

Note It is possible that DC powers of different connection areas differ.


Establish DC voltage connection as follows:
 Establish a connection to the solar panel on the DC input with a
cable with a DC plug connector.
 Use exclusively DC cable connectors and DC receptacles of the
same type and manufacturer.
 Make sure that cable connector in latched in socket correctly.
 Put protective caps on unused plug connectors.

24 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Connection to PLATINUM network

1 2 3 4 5
Fig. 12 Layout of network terminals

(1) Terminal strip


(2) Twist-on connector for PLATINUM network (EIA 485)
(3) Nwtwork connector for PLATINUM network (EIA 485)
(4) Connection diagram for terminating resistor
(5) PC interface to EIA232 (exclusively for service purposes)
It is possible to connect up to 50 PLATINUM inverters. Note

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 25
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Terminal strip connectors

1 2 3 4 5 6 7 8 9 10 11 12
Fig. 13 Layout of terminal strip connectors

(1) Alarm contact (break contact)


(2) Alarm contact (center contact)
(3) Alarm contact (NO contact)
(4) not allocated
(5) Input, max. 12 V (option)
(6) Supply voltage for ext. consumer 12 V,
max. 300 mW
(7) Supply voltage for ext. consumer 0 V,
(8) Shielding EIA485 (RS485)
(9) Line A for PLATINUM network (EIA 485)
(10)Line B for PLATINUM network (EIA 485)
(11)Line A for PLATINUM network (EIA 485)
(12)Line B for PLATINUM network (EIA 485)

Note Terminal strip is protected through cover. Opening the cover is


possible without tools.
DIEHL AKO recommends to use connectors of EIA485 bus line on
terminal strip as follows:
Î For incoming line pair:
t connector 9
t connector 10
Î For outgoing line pair:
t connector 11
t connector 12

26 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Connection for PLATINUM network (EIA 485)

1 2 1
Fig. 14 Network layout
(1) Termination option for engaging the terminating resistor
(2) PLATINUM network (EIA 485)

Material damage due to interchanged lines!


 Ensure that lines A and B are allocated correctly.
 Use exclusively CAT-5 cables with twisted lines and
shielding.
Warning

Establish connection to network as follows:


 Establish connection between inverters or inverters and
monitoring devices on serial interface EIA485 using a cable with
RJ45 plugs or cable on terminal connector (connection A and B)
(see Fig. 12).
 For lines without RJ45 plugs, connect lines A and B in RJ45 plugs
on connectors A and B.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 27
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting

Fig. 15 Termination plug

It is possible to engage the integrated terminating resistor on both


open ends of the network.
Note The termination plug is clamped into the inside of the protector and
fixated with a sticker labelled Netzwerk Terminierungsstecker /
Network Termination Plug.
On first and last inverter in PLATINUM network:
 Plug termination plug into slot for network connection 1.
Alarm contact
 Connect any external indicator device to the potential-free
contact.
t When an error is detected, the contact is closed and
activates the indicator device (optical or acoustic warning).
t Setting: see menu Settings t function Alarm contact
 Only use safety extra low voltage (SELV) of max. 24 V as supply
voltage.

28 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Mounting protector

Fig. 16 Mounting protector

(1) upper part of protector


(2) upper fixture
(3) lower fixture

 Put upper part of protector 2 on upper fixture 1 and slightly push


down housing.
 Slide bottom part of protector in lower fixture 3.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 29
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Locking protective cover
For the free-standing device for outside installation, a protective
cover provides additional protection from rain, sunlight and theft.

1 2

Fig. 17 Free-standing device for outside installation

(1) Protective cover


(2) Protective grate
(3) Power Block protective housing TL Large

 Make closed protective cover snap into place by pressing.


To lock open protective cover in position:
 Open protective cover as far as it will go.
 Push protective cover to the left.
 Lower protective cover until protective cover snaps into place.
To close protective cover locked in position:
 Lift protective cover as far as it will go.
 Push protective cover to the right.
 Close protective cover.
It is possible to lock the protective cover as a protection from
impermissible access.

30 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting

Fig. 18 Locking protective cover

(1) Opening for locking


(2) Protective cover
To lock protective housing:
 Thread cable rope or similar (max. Diameter 13 mm) through
designated holes 1 in bottom of cover and in Power Block
protective housing.
 Secure cable rope or similar with lock.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 31
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up

6 Start Up
Note Independent of demand, the inverter activates the fan as soon as
power input is started (e.g. every morning). When feeding in, the
inverter activates the fan as required.
During the startup, several basic settings such as language selection,
date and time settings are set. Information on display and operation
see 7.2 Display and operation.
Note In order to transfer all settings correctly, it is necessary to do one
complete startup.
If several inverters are installed which are networked via the EIA 485
interface, the startup can be carried out at any one of the installed
inverters (master programming). This inverter transmits the
configuration settings to all other inverters in the network. Every
inverter is automatically assigned a number at its initial startup. The
free allocation of this number is possible in a further step.
The inverters that are not used for input entries display other screen
contents depending on the menu. If no entry is possible, the inverter
shows the start screen.

Start screen
If any input has been entered in the inverter, the inverter shows the
start screen after a restart.

All inverters that are not operated during the configuration will show
the blocking screen.

Note If parameters of the inverter have been adapted to special


requirements of the energy supplier, this is indicated on the start
screen.

32 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
After changing parameters, the inverter shows the following screen:

6.1 Initial startup of inverter

Lack of function due to missing setting!


 Adjust Phase Balancer settings within 4 hours after
startup of inverter (see 6.2 Phase Balancer).
Setting at a later time is no longer possible.
Caution
 Reconfigure country code within four hours after star-
tup of inverter. Setting at a later time is no longer pos-
sible.

 Switch on the main power supply (fuse).


For inverters with DC disconnector:
 Set switch knob to 1.
The inverter is supplied with power. Configuration through the
following dialogs.
Initial startup

Key Function
OK Start configuration process with this inverter.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 33
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Language selection

Key Function
ST Select language.
OK Accept selected language.
After the configuration process has been started:
Î the inverter scans the network connected by the EIA485-Bus for
other inverters.
Î all inverters connected to the network are blocked.

EIA485 bus
As long as the network scan (Scanning Network) is still in process,
the display shows the following screen:

When the network scan is completed, the display shows the number
of detected bus participants. In case of a single inverter, the display
shows 01.

34 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The network scan can only recognize more than 1 inverter if the Note
inverters are correctly networked via the EIA 485 interface.

If the number of detected bus participants (e.g. inverters, data


loggers, etc.) does not agree with the installation:
 Check connections (EIA 485 interfaces) if required.
 Select REPEAT.
 Press OK key.
If the number of detected bus participants is in agreement with the
installation:
 Select OK.
 Press OK key.

In case of a single inverter:


Î Screen Country Code appears.

In case of several networked inverters:


Î Screen Inverter numbering appears.

If one or several inverters have been replaced or not all inverters are Note
numbered correctly, this can be corrected (see 6.3 Replacing
devices).
Inverter numbering
It is possible to network several inverters via the EIA 485 interface.
Inverter numbers are allocated automatically during the network
scan. The inverter number is displayed in the lower left corner of the
screen.
For a clearer overview, the inverters can be re-numbered for specific
requirements. For instance, the inverter number can be defined
according to the installation sequence.
With three inverters installed, the left-hand one is allocated the no. 1, Example
the middle one no. 2 and the right-hand one no. 3.
The following screen is not displayed if only one inverter is Note
configured.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 35
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Screen Inverter numbering:

Key Function
WX YES = Allocate user-defined number to inverter.
NO = Accept inverter number unchanged.
OK Confirm selection.

If NO was selected:
Î The inverter adopts the displayed number und switches to the
Settings Date screen.

If YES was selected:


Î The display shows the following screen.

Note The following screen is not displayed if only one inverter is started up.

Key Function
OK The inverter adopts the next available number.

After OK was selected:


 Allocate numbers to inverters in the required sequence.
t The inverter adopts the next available number.
t The display shows the screen below.

Example As soon as the OK key was pressed at the first inverter, this inverter is
allocated no. 1, which is shown on the display. When the OK key was
pressed at the second inverter, this inverter is allocated no. 2, etc..

36 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The following screen is not displayed if only one inverter is started up. Note

Î Entry only at one inverter. All inverters connected to the network


are blocked.
Î With the number allocation completed, the inverter switches to
the Country Code screen.
Country code
In the menu Country code, the country where the inverter is operated
is set. Country-specific net conditions are set automatically in
dependence on the selected country.
The setting can be changed within 4 hours after the setting and the Note
start of the feeding into the mains supply. Without feeding, the period
is prolonged. After the period has expired, the setting cannot be
changed anymore.

Key Function
ST Select country.
OK Accept selection.

To select country code:


 Select desired country.
 Press OK key.
The inverter automatically transmits the country code setting to all
network participants.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 37
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
After the transmission is successfully completed, the inverter shows
the selected country setting.

Note If an inverter is replaced, only the country code of the replaced


inverter can be changed.
Date

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept date setting.

38 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Time

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept time setting.

Changing date or time can result in overwriting saved data or cause Note
gaps in data recording.

To accept time setting:


 Select SELECT.
 Press OK key.
The inverter automatically shares the new time setting with all
network participants.

To reset time:
 Select BACK.
 Press OK key.
After setting the time, the configuration (language, date and time) are
automatically transferred to all other inverters in the network (if
available).

After the data transmission, the inverter will show the menu Time
settings (see 7.6 Settings).

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 39
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
6.2 Phase Balancer
An unbalanced load ist he difference between the nominal AC power
on the three mains phases.
The energy provider and the power plant operator determine the
admissible maximum unbalanced load for the installation of inverters
on different phases of the supply mains.
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are
equipped with three inverter modules, each of which feeds AC power
on a mains phase.
The Phase Balancer function makes sure that the admissible
maximum unbalanced load is not exceeded.
Î Failure of an inverter module
Î different AC powers occurring in dependence of the load
It is possible to set the admissible maximum power (unbalanced load)
and the reaction time according to the specifications of the power
plant operator (see 8.1 Service Menu).

6.3 Replacing devices


If one or more PLATINUM inverters in a PV system are replaced by
another device, it is possible to transfer the device numbers of the
replaced inverters.
During the network scan, the inverter automatically identifies any
replaced devices.
It is possible to either use the old device numbers for the substitute
devices or renumber the devices.
If inverters without a device number or doubly allocated device
numbers are detected during the network scan, it is possible to
correct this by renumbering them.
Display and operation are confined to the replaced inverters. All other
inverters show the start screen.

40 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
To accept device numbers of replaced inverters:
 Select EXCHANGE INVERTER.
To renumber:
 Select REASSIGN NUMBERS.

Replacement of devices
After EXCHANGE INVERTER was selected, the replaced inverters
show the following screen:

Key Function
WX Select device number.
OK Accept selected device number.

On every replaced inverter:


 Select desired device number.
 Press OK key.
Inverter does another network scan.
The inverter automatically transmits the device numbers to all other
inverters.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 41
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Inverter is added to PLATINUM network.
Inverter shows main menu.
Inverter shows device number of the replaced device in the lower left
corner.

After device replacement:


 Set date and time.

Reassign numbers
 Reassign numbers see 6.1 Initial startup of inverter.

42 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation

7 Operation
7.1 DC disconnector
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL have a Note
separate DC disconnector at each of the three DC inputs.
The DC disconnector enables switching on and off the solar generator.
To engage the solar generator:
 Set DC disconnector to 1 for all three connection areas.
To switch off the solar generator:
 Set DC disconnector to 0 for all three connection areas.
DIEHL AKO recommends to actuate the DC disconnector once a year Note
to prevent the welding of contacts.
DIEHL AKO recommends to switch off the mains voltage (AC) before
switching off the DC disconnector to minimize wear and tear of the
contacts.

1
Fig. 19 DC disconnector

(1) DC disconnector

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 43
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.2 Display and operation
Note If there is no input for approx. 2 minutes, inverter switches to
standard display during feed.

1 2 3 4 3 5 6

12

11

10

9 8 7
Fig. 20 Display and operation

(1) Time
(2) LED red
(3) Scroll arrows horizontal
(4) Title
(5) LED green
(6) Date
(7) OK key
(8) Navigation keys
(9) ESC key
(10)Device number
(11)Scroll arrows vertical
(12)Day

44 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Time
Time display in 24-hour format.
LEDs
Two LEDs indicate the operating status of the inverter.

The LED red indicates the following: LED red


Display Operating status
LED off Normal operation
LED flashes - Error
- Contact for external indicator closed
(depending on selected setting)

The LED green indicates the following: LED green


Display Operating status
LED on Power feed on
LED flashes Preparing for power feed
LED off Inverter off

Both LEDs blinking indicate that the inverter is performing a network Both LEDs
scan.
Scroll arrows
The menu contains other menu items.
 Navigate using keys T and S or W and X.

Title
Title of the selected menu.
Date
Date display in formats DD.MM.YY, MM.DD.YY oder YY.MM.DD.
Adjustable in menu Time settings.
Keys
The functions of the keys are indicated in the tables under the
illustrations.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 45
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Device number
Displays the inverter number.

Day
Displays the day of the week.

7.3 Standard screen

Key Function
WX Navigate within the display period.
ST Switch to screen Current.
ESC Call up Main Menu.

Arrow to the right of the table:


Î designation of physical value displayed in graphic

Number in the top left corner of the graphic:


Î maximum value of scale
Î depending on max. DC power of the inverter

7.4 Main Menu

Key Function
ST Navigate within menu.
OK Call up selected menu.

To return to main menu from all menus:


 Press ESC repeatedly.

46 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.5 Operating Display
The operating display shows a list of physical values and a
corresponding evaluation graph. Type and value of the displayed
physical value depend on the selected period. The illustration below
shows an example for the period TODAY.

Key Function
WX Navigate within the display period.
ST Switch to menu Current.
ESC Back to Main Menu.

Arrow to the right of the table:


Î designation of physical value displayed in graphic

Units:
Î W: feed power
Î kWh or MWh: feed power for the indicated period
Î EUR: rebate for the indicated period (Adjustable in menu
Settings.)

Î kg: quantity of saved carbon dioxide (CO2)

Number in the top left corner of the graphic:


Î maximum value of scale
Î dependent on inverter power

Horizontal axis in graphic:


Î time scale (e. g. hours of a day)

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 47
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Current
Screen Current shows the distribution of the current power to the
individual inverter modules.
Î Bar frame displays maximum power of respective inverter.
Î Bar content displays current power of respective inverter.

Key Function
S Call up screen Operating Display.
T Call up screen Current Phase 1.
ESC Back to Main Menu.

Show current phase 1, phase 2 or phase 3:


Î List of current electrical values for DC and AC side.
Î Separate AC currents for all three phases.

48 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation

Key Function
S Call up screen Current.
T Call up screen Current Phase 2.
ESC Back to Main Menu.

Key Function
S Call up screen Current Phase 1.
T Call up screen Current Phase 3.
ESC Back to Main Menu.

Key Function
S Call up screen Current Phase 2.
T Call up screen Operating Display.
ESC Back to Main Menu.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 49
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Physical values

The following physical values are indicated:


Î feed power in W (graphically depicted in the periods TODAY and
YESTERDAY)
Î feed energy in kWh or MWh (graphically depicted as columns in
the periods WEEK, MONTH and YEAR)
Î Rebate in country-specific currency
t Values > 999,000 are displayed as a factor
t Example: 1,234,567 € is displayed as 1,234E6
Î CO2 emission reduction in kg or t
Î DC and AC voltage
Î DC and AC
Î DC and AC power

Display period
The following display periods can be selected:
Î Today
Î Yesterday
Î Current week
Î Previous week
Î Current month
Î Previous month
Î Current year
Î Previous year
Î Since startup

Note The values displayed by the inverter may differ from the readings of
calibrated electricity meters.

1 2
(1) Physical values
(2) Graphic of physical value

50 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Physical values:
t Designation of the physical value
t Current value ( )
t Peak value ( )
t Cumulative value ( )

Graphic of physical value:


Î Day: in hours (0 - 24)
Î Week: one column per day (Mo. - Su.)
Î Month: one column per day
Î Year: one column per month (Jan. – Dec.)

Type and value of the displayed physical value depend on the selected Note
period.
Graphic: For the display periods TODAY and YESTERDAY, the
progress of the feed power is displayed. For all other display periods
the feed energy per time interval is displayed.
Table: For the display period TODAY, the current power value is
displayed. For all other periods, the maximum value is displayed.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 51
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.6 Settings
In the menu Settings the following settings are possible:
Î Time settings
Î Language
Î Alarm volume
Î Alarm contact function
Î LCD
Î Rebate
Î System
Î Energy meter

Key Function
ST Navigate within menu.
ESC Back to Main Menu.
OK Call up selected menu.
Time settings
In the menu Time settings, the following settings are possible:
Î Date
Î Time
Î Date format
Î Daylight saving time

Key Function
ST Navigate within menu.
ESC Back to menu Settings.
OK Call up selected menu.

52 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Date

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept date setting.

Time

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
OK Accept time setting.

Changing date or time can result in overwriting saved data or cause Note
gaps in data recording.

To accept time setting:


 Select SELECT.
 Press OK key.
The inverter automatically shares the new time setting with all
network participants.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 53
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
To not accept time setting:
 Select CANCEL.
 Press OK key.

Date format

Key Function
ST Select format.
OK Confirm format.
ESC Return to menu Time setting.

Daylight saving
time

Key Function
ST Navigate within menu.
OK Confirm selection.
ESC Return to menu Time setting.
MANUALLY
Î Manual setting of daylight saving time required.
AUTOMATIC
Î Inverter sets daylight saving time automatically, depending on set
country and calendar.

54 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
If the MANUALLY option is selected, the following screen will appear
the next time the date or time is set:

To set daylight saving time:


 Select YES.
 Press OK key.
Inverter adds 1 hour to set time.
To not set daylight saving time:
 Select NO.
 Press OK key.

Inverter uses set time unchanged.


Alarm volume

Key Function
ST Increase or reduce alarm volume.
ESC Back to menu Settings.
OK Accept alarm volume setting.

The inverter automatically transfers the alarm volume setting to all


network participants.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 55
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Alarmkontakt

Key Function
ST Navigate within menu.
ESC Back to menu Settings.
OK Accept setting.

OFF
Î The alarm contact (NO contact) is constantly open if a safety-
relevant or blocking error occurs.
Î Alarm contact deactivated.

INTERVAL
Î The alarm contact (NO contact) opens and closes periodically if a
safety-relevant or blocking error occurs.
CONTINUOUS
Î If a safety-relevant or blocking error occurs, the alarm contact
(NO contact) is constantly closed until the error is remedied.

TEST
Î Close alarm contact temporarily while selecting a menu item.

56 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
LCD

Key Function
ST Increase or reduce contrast or brightness.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.

Feed payback

Key Function
CURRENCY Currency in which the rebate is displayed.
VALUE/KWH Value for 1 kWh feed current (for rebate calculation).
ST Increment or decrement present digit.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.

If the inverters are connected to the PLATINUM network, the input of Note
the value for the rebate is only necessary in one inverter. After the
input is finished, the value is automatically transferred to all other
inverters.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 57
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
System

Key Function
ST Increment or decrement present digit.
WX Navigate between input fields.
ESC Back to menu Settings.
OK Accept setting.

Energy meter
The energy meter enables the metering of energy and operating hours
since the start of the inverter or since a reset of the energy meter.

Key Function
BACK Back to menu Settings.
RESET Set energy meter to 0.
WX Select BACK or RESET.
OK Confirm selection.
ESC Back to menu Settings.

58 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.7 Information
The menu Information shows the following information:
Î Operating data
Î System data
Î Inverter type
Î Inverter version
Î Event information

The menu Information merely displays values. It is not possible to Note


change the values.
Operating data

Key Function
S Call up screen Inverter version.
T Call up screen System data.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.

GENERAL
Î Shows feed data of the inverter since the startup.
Î Resetting is not possible.
METER 2
Î Shows feed data of the inverter since the latest reset of meter 2.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 59
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
System data

Key Function
S Call up screen Operating data.
T Call up screen Inverter type.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.

NAME
Î Shows the name of the PV system.
NO. OF PARTICIPANTS
Î Indicates number of network participants (e. g. inverter and
monitoring devices such as PLATINUM PV-Monitor, PLATINUM
ViewMaster and PLATINUM Webmaster).
NO. OF INVERTERS
Î Shows the number of inverters in the network.

60 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Inverter type

Key Function
S Call up screen System data.
T Call up screen Inverter version.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.

TYPE
Î Indicates inverter type.
S/N
Î Indicates inverter serial number.

When contacting the PLATINUM service, have the serial number Note
ready.
After changing the inverter network parameters, the display indicates
USER-DEFINED NETWORK MONITORING..

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 61
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Inverter version

Key Function
S Call up screen Inverter type.
T Call up screen Operating data.
ESC Back to menu Main Menu.
OK Back to menu Main Menu.

FIRMWARE
Î Shows the inverter firmware version.
HARDWARE
Î Shows the inverter hardware version.
EIA485
Î Shows the data bus software version.
BL
Î Shows version of bootloader software.

62 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
7.8 Error display
The error displays are meant for the user. Any detected errors are
displayed with a slight delay. In case of an error, the inverter displays
the error type and error code. Error causes and measures
see 12 Troubleshooting.

Three types of errors:


Î fatal errors
Î blocking errors
Î non-blocking errors

Fatal errors

Destruction of invterter due to fatal errors!


 Switch off AC.
 Switch off DC.
If available:
Warning
 Set DC disconnector to 0.

 Notify PLATINUM service.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 63
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Blocking errors

Danger to life due to electric shock!


 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
DIEHL AKO.
Danger

In case of a blocking errror:


Î the inverter is permanently off.
Î the inverter gives an optical alarm (red LED flashing).
Î the inverter gives an acoustic alarm.
Î the inverter closes the alarm contact.
Setting: see screen Settings t function Alarm contact.
Exclusively service personnel can remedy the blocking error and
switch the inverter back on.
To stop the acoustic alarm:
 Press any key.
To delete the error display:
 Press ESC key.
If the acoustic alarm is activated:
Î Inverter switches off acoustic alarm.

 Press key ESC again.


Inverter shows start screen.
Red LED flashes as long as the error persists.

64 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Non-blocking errors and warnings

Key Function
OK Clears the error display
ESC Leave error display.

Non-blocking errors are of a transient nature (e.g. mains voltage


surge). The inverter remains switched off until the error cause no
longer persists.
When the error has been remedied, the inverter automatically
switches to normal operation.
Until the error is resolved:
Î The inverter displays the screen Non-blocking error.
Î The red LED is flashing.
 Delete error display with key ESC.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 65
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service

8 Service
8.1 Service Menu
The menu Service offers the following information and functions:
Î display event list
Î display parameters
Î set max. unbalanced load (Phase balancer)
Î Reconfiguration
Î display startup date
Î display feed meter

Note Displaying other parameters or changing the parameters is


exclusively possible with a separate service tool.
To call up the Service Menu:
 Go to menu Settings and select menu item Time setting and
press buttons W and X for about 3 s.

Key Function
ST Navigate within menu.
ESC Return to standard display.
OK Call up selected menu.

66 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Event list

Key Function
ST Navigate within the event list.
ESC Return to menu Service.

Columns:
Î 1. column: Event no.
Î 2. column: If available, designation of unit within inverter
Î 3. column: Event date
Î 4. column: Event time
Î 5. column: Event code

The inverter shows the last 100 detected events. Note


Explanations about the events see 12.1 Table of events.
Have the event code and the serial number ready when contacting
the PLATINUM service.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 67
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Parameters
In some supply areas, the values for supply voltage and frequency
may differ temporarily or permanently from the factory settings. It is
possible to adapt the PLATINUM inverter to these values. Contact the
PLATINUMservice for this.
The screens Parameters show the valid ENS type and the currently
set parameters such as start time, minimum and maximum values of
frequency and voltage with the respective reaction times.
The parameters can exclusively be modified by certified persons with
the PLATINUM service tool.
Version Screen Version shows information on inverter type.

Key Function
S Return to menu Service.
T Call up screen Frequency Limits.
ESC Back to menu Main Menu.

68 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Screen Frequency Limits shows: Frequency limits
Î set frequency limits
Î switch-off times for exceeding or falling below frequency limits

Key Function
S Call up screen Version.
T Call up screen Voltage Limits.
ESC Back to menu Main Menu.

Screen Voltage Limits shows: Voltage limits


Î set voltage limits
Î switch-off times for exceeding or falling below frequency limits

Key Function
S Call up screen Frequency Limits.
T Call up screen Mains Quality.
ESC Back to menu Main Menu.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 69
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Mains quality Screen Mains Quality shows information on mains quality.

Key Function
S Call up screen Voltage Limits.
T Call up screen Fault Current.
ESC Back to menu Main Menu.

Fault current Screen Fault Current shows:


Î set limits for fault currents or fault current changes
Î switch-off times for exceeding ot falling below fault current limits

Key Function
S Call up screen Mains Quality.
T Call up screen Fault Current.
ESC Back to menu Main Menu.

70 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service

Key Function
S Call up screen Fault Current.
T Call up screen Limits.
ESC Back to menu Main Menu.

Screen Limits shows set limits of: Limits


Î AC and DC powers
Î AC and DC currents

Key Function
S Call up screen Fault Current.
T Call up screen Version.
ESC Back to menu Main Menu.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 71
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Phase Balancer
It is possible to set the admissible maximum power (unbalanced load)
and the reaction time according to the specifications of the power
plant operator.
Operating mode

Key Function
ST Select operating mode.
ESC Back to menu Main Menu.
OK Accept selected operating mode.

OFF
Î Switch off Phase Balancer function.
Î No limit of unbalanced load.
POWER CONTROL
Î Switch on Phase Balancer function.
Î The inverter monitors and limits the difference between AC
powers.
ERROR OFF
Î If one inverter module fails, the inverter will disconnect the other
modules from the mains.
ERROR REDUCE
Î If one inverter module fails, the inverter limits the AC power of the
other modules to the set unbalanced load.

72 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
admissible
maximum
power
(unbalanced load)

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
ESC Back to menu Main Menu.
OK Accept setting.

Range of values:
Î 200 W to 9,999 W

Factory setting:
Î 5,000 W

Reaction time

Key Function
ST Increment or decrement present digit.
WX Select next or previous digit.
ESC Back to menu Main Menu.
OK Accept setting.

Range of values:
Î 10 s to 9,999 s

Factory setting:
Î 300 s

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 73
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
If the inverter is connected in the PLATINUM network, all parameters
and the Phase Balancer settings are transferred to the other inverters
of the PLATINUM network after the reaction time has been confirmed.
During the transfer, the inverter shows the following screen.

After a successful transfer, the inverter shows the following screen.

Reconfiguration
Inverter shows screen Start initial startup (see 6.1 Initial startup of
inverter).
Note A reconfiguration of the country is only possible within the first four
hours after the connection. Afterwards, this menu item is blocked.

74 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
Startup

Key Function
OK Return to menu Service.
ESC Return to menu Service.

Shows startup date.


The menu is only a display. Values cannot be changed. Note

Meter

Key Function
OK Return to menu Service.
ESC Return to menu Service.

The menu is only a display. Values cannot be changed.


Inverter numbering

To change the inverter numbering after startup:


 Select Reconfiguration in the Service Menu.
 Change inverter numbers see 6.1 Initial startup of inverter,
subsection Allocating inverter numbers.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 75
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Maintenance

9 Maintenance
Danger to life due to electric shock!
 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
DIEHL AKO.
Danger

Danger to life do to DC and AC high voltage!


 Wear insulating protective clothing and face
protection.
 Have any cleaning or maintenance works carried out
Danger
exclusively by trained personnel.
The qualified specialist personnel requires a license
from the relevant energy suppliers.
Prior to every maintenance work or cleaning:
 Switch off the main power supply (fuse).
 Set switch knob of DC connector to 0.
 De-energize AC side and secure it against switching
on.
 Condensers require up to 30 min to discharge. Do not
touch connectors (DC/AC) for at least 5 minutes after
switching off.
 Ensure that the DC cables are de-energized.
In case of a PLATINUM inverter without DC disconnector
and AC cable:
 Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.

9.1 Maintenance
The inverter is maintenance-free.

76 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Maintenance
9.2 Cleaning

Damage of fan due to high fan speed!


 Exclusively clean the PLATINUM inverter carefully
with compressed air.
Caution

To ensure proper cooling, do the following regularly:


 Clean ventilation openings with:
t vacuum cleaner
t soft brush
t compressed air

In a dusty environment:
 Check fan and cooling elements regularly and clean them if
necessary.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 77
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation

10 Placing out of operation


10.1 Dismounting

Danger to life do to DC and AC high voltage!


 Wear insulating protective clothing and face
protection.
 Have inverters uninstalled by qualified specialists
Danger
only.
The qualified specialist personnel requires a license
from the relevant energy suppliers.
 Switch off the main power supply (fuse).
 Set switch knob of DC connector to 0.
 Condensers require up to 30 min to discharge.
Do not touch connectors (DC/AC) for at least 5
minutes after switching off.
 Ensure that the DC cables are de-energized.
It is possible that DC cables carry dangerously high
voltages even if the DC disconnector is switched off.
In case of a PLATINUM inverter without DC disconnector
and AC cable:
 Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.

Danger to life due to inverter dropping from the wall!


 Use mounting elements appropriate for the mounting
wall and the weight of the inverter unit.
During mounting and dismounting:
Danger
 Wear protective shoes.
 Ensure a stable position.

To disconnect the inverter:


 Switch off the main power supply (fuse).
 Remove cable from AC terminal.
 Set DC disconnector to 0 and pull plug connector of input voltage
(DC side).
 Disconnect remaining connectors as required.

78 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Dismount the inverter as follows:
 Lift the inverter up and out of the mounting fixture.

Remove the mounting fixture as follows:


 Unscrew the mounting fixture.
 Insert the mounting fixture at the back of the inverter.

In case of a return consignment:


 Pack the inverter in the packaging of the replacement.
If a single inverter is returned:
 Demand additional packaging from Diehl-Controls or reuse it.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 79
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Packing up the wall-mounted device

Fig. 21 Packing up the wall-mounted device

(1) Upper part of packaging


(2) Wooden protection elements
(3) Bottom part of packaging
(4) Transport pallet

 Put transport pallet 4 on even ground.


 Put bottom part of packaging on transport pallet 4.
 Put inverter in bottom part of packaging 3.
 Put upper part of packaging 1 on inverter.
 Secure the box with packing straps.

80 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Placing out of operation
Packing up the free-standing device

1
Fig. 22 Packing up the free-standing device

(1) Transport pallet

 Put transport pallet 1 on even ground.


 Put inverter on transport pallet 1.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 81
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Disposal

11 Disposal

 Dispose of packaging and consumed parts


according to the rules and regulations
applicable in the country where the device was
installed.
 Do not dispose of the PLATINUM inverter in the
household waste.

Note DIEHL AKO takes back PLATINUM inverters completely.


It is possible to dispose of PLATINUM inverter through communal
disposal of electrical appliances.

12 Troubleshooting
12.1 Table of events
To isolate the error, have the following information ready when calling
Service:
Î displayed error number (No.)
Î serial number of the inverter (see 7.7 Information)

No. Operating status Measure


Fatal errors
90 AC voltage too high Separate inverter from mains.
Check connection of AC plug.
91 DC voltage too high Separate inverter from mains.
Separate inverter from DC terminal.
Check module interconnection.
92 Polarity of DC connection Check DC connection.
reversed
93 Insulation error between PV+ or Check insulation of PV modules.
PV- and earth Check insulation of PV wiring.
94 Fatal Disconnect AC connector from inverter input. Call Service.
system error Provide the service with the error code if required.
95 Fatal Call Service.
system error Provide the service with the error code if required.

82 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Troubleshooting

No. Operating status Measure


Blocking errors
100 Blocking Separate inverter from mains.
to system error Restart inverter.
106
If measure is not successful:
Call Service.
107 Blocking Separate inverter from mains.
to system error Restart inverter.
129
If measure is not successful:
Call Service.
130 Connections L and N reversed Check connections L and N on AC plug.
131 Blocking Separate inverter from mains.
to system error Restart inverter.
199
If measure is not successful:
Call Service.
167 Error in AC overvoltage protec- Call Service.
tion Provide the service with the error code if required.
171 Error in DC overvoltage protec- Call Service.
tion Provide the service with the error code if required.
175 Error in power electronics Call Service.
Provide the service with the error code if required.
Non-blocking errors
201 AC voltage on feed phase below Have AC voltage of feed phase checked.
or above limits
202 exclusively for 3 phase ENS Ensure that all fuses are switched on.
to Voltage on one of the outer con-
204 ductors below or above limits Startup:
Have inverter 3-phase connected.
208 System incident on feed phase If error occurs frequently:
(voltage peak) Have all bondings and fuses between the consumer’s terminal
and the inverter checked.
Have the mains quality checked.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 83
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Troubleshooting

No. Operating status Measure


209 Mains quality limit If mains voltage on feeding point is permanently too high:
exceeded Check voltage dip on mains lead.
Inform power plant operator.
Check value for mains quality limit.
210 Mains frequency above or If inverter is running on emergency power (different main
211 below limits frequency):
No measure required.
212 Diagnosis support during Provide the service with the error code if required.
to service
213
214 too high fault current when If error occurs frequently:
to switching on Check insulation resistance on DC side.
218
220 measured temperatures too Check ventilation openings.
to high
225
226 max. mains current exceeded Check AC side for short circuit.
230 Temperature sensor defective Separate inverter from mains.
to Restart inverter.
233
If measure is not successful:
Call Service.
234 Diagnosis support during ser- Separate inverter from mains.
to vice Restart inverter.
261
If measure is not successful:
Call Service.
262 power supply on interface card Disconnect connections on interface card
overloaded Check connections on interface card for short circuit.

If measure is not successful:


Call Service.
Provide the service with the error code if required.
263 Diagnosis support during Provide the service with the error code if required.
to service
289
271 max. AC exceeded Check AC side for short circuit.
to
273

84 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Standards and Approvals

No. Operating status Measure


274 min. DC voltage not reached
275 manual stop Check position of EMERGENCY STOP switch.
Call Service.
Provide the service with the error code.
291 Diagnosis support during Provide the service with the error code if required.
to service
299
Warning
300 Diagnosis support during Provide the service with the error code if required.
to service
399 Inverter stores warning in event
memory
Information
400 Diagnosis support during Provide the service with the error code if required.
to service
499 Inverter stores warning in event
memory
Causes
500 Diagnosis support during Provide the service with the error code if required.
to service
599 Inverter stores warning in event
memory

13 Standards and Approvals


The inverter complies to the following standards:
Î DIN EN 50178: 1998-04
Î DIN EN 61 000-3-2: 2006-10
Î DIN EN 61 000-3-12: 2005-09
Î DIN EN 61 000-3-3: 1994 / A2: 2005
Î DIN EN 61 000-3-11: 2001-04
Î DIN EN 61 000-6-2: 2006-03
Î DIN EN 61 000-6-3: 2007-09

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 85
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Technical Data

14 Technical Data
Input characteristics 13000 TL 16000 TL 19000 TL 22000 TL
Maximum PV power 14,700 Wp 18,000 Wp 21,300 Wp 24,300 Wp
Maximum DC power 12,900 W 15,900 W 18,900 W 21,600 W
PV-voltage range, MPPT 351 – 710 V 349 – 710 V 350 – 710 V 351 – 710 V
Maximum DC voltage 880 V
Maximum input current 3 x 13.0 A 3 x 16.0 A 3 x 18.5 A 3 x 21.0 A
Number of string inputs 6 6 9 9
Number of MPP trackers 3
DC section switch device DC disconnector, integrated in the appliance
Reverse battery protection yes
Output characteristics
Nominal AC power rating 11,250 W 13,800 W 16,550 W 18,900 W
Nominal AC-intensity 3 x 16.3 A 3 x 20.0 A 3 x 23.9 A 3 x 27.4 A
Maximum AC power 12,360 W 15,000 W 18,000 W 20,700 W
Maximum AC intensity 3 x 17.9 A 3 x 21.7 A 3 x 26.1 A 3 x 30.0 A
Feed operation starts at 7W 7W 7W 8W
Mains output voltage range 3 x 230 V (+/-20%) feeding on three phases
Internal consumption at night below 6 W
Mains frequency 47.5 Hz – 52.2 Hz
Short-circuit proof yes
Interfaces
DC input DC plug, Multicontact MC3, MC4, Tyco
AC output Spring clamp connectors
PLATINUM network EIA 485, 2x RJ45 Western Modular add. plug connector with
terminal screws
Service interface EIA 232, SubD 9-pole socket
Potential-free contact Change-over contact, maximum 24 V AC/2 A, plug connector with
terminal screws
Appliance data
Maximum degree of efficiency 97.3% 97.4% 97.7% 98.0%
European efficiency 96.8% 96.8% 97.3% 97.6%
Weight 81 kg 84 kg 87 kg 87 kg

86 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Technical Data

Input characteristics 13000 TL 16000 TL 19000 TL 22000 TL


Dimensions H 743 mm x W 972 mm x D 262 mm
Working temperature range -20 °C to +60 °C
Maximum temperature during +45 °C
nominal power
Storage temperature -20 °C to +80 °C
Maximum air humidity 95%
Degree of protection (except IP65 according to DIN EN 60529
digital interface)
Optical display Full graphic 170 x 76 pixels
Integrated datalogger Storage capacity sufficient for 30 yrs operating time
Circuit concept Transformerless, DIVE, RAC-MPP, ENS according to VDE 0126-1-1

Technical data apply to maximum height above MSL of 2,000 m. Note

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 87
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
EC Declaration of Conformity

15 EC Declaration of Conformity
Issuer’s name and Diehl AKO Stiftung & Co. KG
address: Pfannerstraße 75
D-88239 Wangen im Allgäu, Germany
Product Solar inverter
designation:
Type designation: PLATINUM 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
PLATINUM 13000 TL, 16000 TL, 19000 TL, 22000 TL
The designated devices comply with the provisions of EU directives.
Especially the Low Voltage Directive 2006/65/EG and the EMC
directive 2004/108/EG.
The designated devices conform to the following norms:
Î DIN EN 50178: 1998-04
Î DIN EN 61 000-3-2: 2006-10
Î DIN EN 61 000-3-12: 2005-09
Î DIN EN 61 000-3-3: 1994 / A2: 2005
Î DIN EN 61 000-3-11: 2001-04
Î DIN EN 61 000-6-2: 2006-03
Î DIN EN 61 000-6-3: 2007-09
Consequently the products mentioned above carry the CE mark.
Furthermore, we declare that the products mentioned above comply
with the prescriptions of the VDEW (German Electricity Industry
Association) that apply to solar inverters according to the “Directive
for the Connection and Parallel Operation of Energy Generation
Equipments in the Low-Voltage Mains”.

Wangen im Allgäu, 09/01/2009


Diehl AKO Stiftung & Co. KG

ppa. Klaus Frehner


CEO Photovoltaics
Phone: +49 (0) 7522 73 0
Fax: +49 (0) 7522 73 300
Mailto: info@diehlako.com
www.diehlako.de

88 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG

16 Manufacturers Warranty of Diehl AKO


Stiftung & Co. KG
(Address: D-88239 Wangen im Allgäu, Pfannerstraße 75)
1. Warranted Products
This manufacturer’s warranty applies to transformerless three-phase
string inverters of the PLATINUM range of inverters for photovoltaic
systems manufactured by Diehl AKO Stiftung & Co. KG (Diehl AKO),
as far as these inverters were evidently purchased as new units from
Diehl AKO or MATRIX Power Systems GmbH or from a wholesaler,
retailer or specialist installation company authorized by Diehl AKO or
MATRIX Power Systems (Warranted Products). Such evidence is
regarded as given when Diehl AKO is provided with an original invoice
documenting the delivery of a Warranted Product to the Warranted
User and if Diehl AKO is identified as the manufacturer by an
authentic manufacturer label on the Warranted Product.
2. Beneficiaries from this manufacturer’s warranty
Diehl AKO grants this manufacturer’s warranty only to users who
demonstrably have purchased, and are the actual users of a
Warranted Product (Warranted User). Traders of any kind and trade
level do not gain from this manufacturer’s warranty any rights and
claims against Diehl AKO.
3. Establishment of the warranty
The manufacturer’s warranty is meant as an offer by Diehl AKO
directly to the Warranted User on entering a warranty agreement
under the conditions laid down in this document. The warranty
contract is established directly and automatically between Diehl AKO
and the Warranted User at the moment of purchase of a Warranted
Product, if the Warranted User does not object to the establishment of
the warranty agreement, in writing to Diehl AKO within 2 (two) weeks
from the purchase date of a Warranted Product.
4. Coverage of the manufacturer’s warranty
The manufacturer’s warranty grants the Warranted User warranty
rights in addition to the Warranted User’s warranty rights granted by
the respective vendor. Warranty rights vis-à-vis the respective vendor
and statutory product liability rights are unaffected by the
manufacturer’s warranty.
5. Period and assertion of the manufacturer’s warranty
The manufacturer’s warranty applies to defects of the Warranted
Products which demonstrably occur between the beginning of the
twenty-fifth and the end of the sixtieth month after installation and
commissioning of a Warranted Product at the Warranted User’s
premises (Warranty Period). This Warranty Period ends not later than

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 89
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
66 months after the manufacturing date of the Warranted Product, as
stated on the type plate of the Warranted Product. For Warranted
Products repaired or replaced by Diehl AKO, the manufacturer’s
warranty expires with the end of the original Warranty Period. Legal
and/or contractual warranty claims of any kind, which arise during a
statutory or contractual warranty period, can not be derived from this
manufacturer’s warranty.
Any claims based on the manufacturer’s warranty must be asserted
in writing by the Warranted User to Diehl AKO within the Warranty
Period. Such warranty claims can be submitted through an authorized
specialist retailer, wholesaler or specialist installation company, or
through MATRIX Power Systems GmbH.
6. Rights under the manufacturer’s warranty – Damage and costs
not covered
If a defect of the Warranted Product occurs during the Warranty
Period and if Diehl AKO is responsible for this defect and if this defect
impairs or reduces the functionality of the Warranted Product to a
significant extent, Diehl AKO will choose to carry out either free-of-
charge repairs or free-of-charge replacement of the Warranted
Products with a product that offers at least the same or the same type
of functionality and performance.
Such repairs or replacement will be carried out only at the Diehl AKO
factory. Transport to Diehl AKO must be in the original packaging or
other packaging that is at least of the same quality as the original
packaging. If the Warranted user requests repair or replacement at a
site other than the Diehl AKO factory, Diehl AKO can agree to this
request. In this case, however, the Warranted User will bear any
travel costs and additional labor costs according to DIEHL AKO
standard rates.
Any claims from the manufacturer’s warranty beyond free-of-charge
repair or free-of-charge replacement are ruled out, especially any
claims on compensation for defect-related capital damage, e.g. loss
of profit including compensation for lost power feeds, costs of
installation and de-installation, costs of fault diagnostics, recall costs
and interruption to production processes.
If no defect is found in the Warranted Product sent in for repair or
replacement, or if there is no claim based on the manufacturer’s
warranty for any other reason, Diehl AKO may demand from the
Warranted User an administration fee (flat rate per product) plus the
costs of transport back to the Warranted User.
Any claims based on this manufacturer’s warranty expire 6 months
after occurrence of the fault, but not later than 3 months after the end
of the Warranty Period.

90 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
7. Exclusion cases
Any claims of the Warranted User are excluded in the following
cases:
Î Improper use
Î Unprofessional or incorrect installation, installation not complying
to standards, or installation not following the installation
directions or instructions provided by Diehl AKO
Î Unprofessional or incorrect operation and use, or operation and
use against the operating directions or instructions provided by
Diehl AKO
Î Operation with defective protective systems
Î Any unauthorized modifications or repairs
Î Use of replacement parts and accessories non-compliant with the
original Diehl AKO specifications
Î Failure to perform continuous maintenance according to the
maintenance directions and instructions provided by Diehl AKO
Î Removal, damage or destruction of the sealing or the type plate
installed by Diehl AKO or MATRIX Power Systems
Î Foreign-body influence and force majeure
Î Non-compliance with applicable safety regulations
Î Transport damage
Î Lightning damage

8. Portability of the guarantee


This agreement on guarantee and the rights that result from it can
only be transferred from a licencee to a third party with a previous,
written approval. When the guaranteed products are removed from
the original assembly and operation spot and reassembled at a
different location the guarantee expires automatically.
In cases other than those agreed on the guarantee may be tranferred
to a third licencee when (i) the third licencee acquires the operation
real estate from the licencee entitled to the guarantee, (ii) proof of the
acquisition is presented to Diehl AKO in written and with the naming
of the third licencee, (iii) the products assembled that are guaranteed
remain unchanged and (iv) the third licencee declares to Diehl AKO its
agreement to these conditions of guarantee in written form.

Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL 91
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
9. General provisions
Claims by the Warranted User based on this manufacturer’s warranty
can only be transferred to third parties with prior written consent of
Diehl AKO.
Should any clause of this manufacturer’s warranty be or become
void, all other stipulations of the manufacturers warranty remain in
force. In place of the clause that is or has become void, a valid clause
is automatically regarded as agreed. The replacement clause will be
as close as possible to the voided clause in its economic substance.
The same rule applies to any missing clause in this agreement.
This manufacturer’s warranty is subject only to the laws of the
Federal Republic of Germany, excluding the stipulations of Private
International Law and the UN Convention on the International Sale of
Goods.
The exclusive place of jurisdiction in case of any conflict arising from,
or in connection with this manufacturer’s warranty, is Wangen im
Allgäu/FRG.

92 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Version 05/2010
Mat. No. 737 576-AB
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Diehl AKO Stiftung & Co.KG

Pfannerstraße 75
D-88239 Wangen
Fon: +49 7522 73 700
Fax: +49 7522 73 710
Mailto: platinum@diehlako.com
www.diehlako.com

Service
Diehl AKO Stiftung & Co. KG
Pfannerstraße 75 Tel.:+49 7522 73 777 Mailto:service.platinum@diehlako.com
D-88239 Wangen Fax+49 7522 73 737 www.diehlako.com

Downloaded from www.Manualslib.com manuals search engine