POLYDOROS IT / IT-S
                                                                                    CO
Configuration
POLYDOROS IT / IT-S
Configuration Lists
The Configuration Instructions, COPL-136.843.02..., are
part of these instructions
                       07759728
                       07463909
                       05760090
                       05760082
                                                          © Siemens AG                   2005
                                                          The reproduction, transmission or use
                                                          of this document or its contents is not
                                                          permitted without express written
                                                          authority. Offenders will be liable for
                                                          damages. All rights, including rights
                                                          created by patent grant or registration
                                                          of a utility model or design, are
                                                          reserved.
Print No.: COPL-136.843.03.01.02                          English
Replaces: n.a.                                            Doc. Gen. Date: 08.05
2                                                                               Revision / Disclaimer
1Revision / Disclaimer
                         Document revision level
                         The document corresponds to the version/revision level effective at the time of system
                         delivery. Revisions to hardcopy documentation are not automatically distributed.
                         Please contact your local Siemens office to order current revision levels.
                         Disclaimer
                         The installation and service of equipment described herein is to be performed by qualified
                         personnel who are employed by Siemens or one of its affiliates or who are otherwise
                         authorized by Siemens or one of its affiliates to provide such services.
                         Assemblers and other persons who are not employed by or otherwise directly affiliated
                         with or authorized by Siemens or one of its affiliates are directed to contact one of the
                         local offices of Siemens or one of its affiliates before attempting installation or service pro-
                         cedures.
POLYDOROS IT / IT-S                   COPL-136.843.03.01.02                    Page 2 of 16                  Siemens AG
                                      08.05                                    CS PS 212                 Medical Solutions
Table of Contents                                                                                                                   3
1-              0Table of Contents
1 _______ Standard Console Configuration Lists ______________________________ 4
2 _______ Touch Panel Configuration List ____________________________________ 8
3 _______ Organ programs (with standard console) ___________________________ 12
               Bucky table organ program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
               Bucky wall stand organ program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 _______ Changes to Previous Version_____________________________________ 16
Siemens AG                           COPL-136.843.03.01.02                         Page 3 of 16               POLYDOROS IT / IT-S
Medical Solutions                    08.05                                         CS PS 212
4                                                    Standard Console Configuration Lists
2-
1Standard Console Configuration Lists
    Service Menu                        Submenu 1         Submenu 2         Submenus 3/ 4
    Configuration                       Generator         Grid              Stationary grid                          Q
    Information: See the                                                    Moving grid                              Q
    Configuration Instruc-
    tions.
                                                          max Values        P max             _________________
                                                                            UT max            _________________
                                                                            IT max            _________________
                                                                            mAs max           _________________
                                                          IONTOMAT          Bucky table       HSE                    Q
                                                                                              6 mm chamber           Q
                                                                                              12 mm chamber          Q
                                                                                              invert MF              Q
                                                                            Bucky wall        HSE chamber            Q
                                                                            stand             6 mm chamber           Q
                                                                                              12 mm chamber          Q
                                                                                              invert MF              Q
                                                          HV cable          10 m                                     Q
                                                                            16 m                                     Q
                                                                            24 m                                     Q
                                        Control console   Settings          Display light
                                                                            Date
                                                                            tube load Indi-   Show HU value          Q
                                                                            catior            Tube load buzzer       Q
                                                                            Default Organ Programs
                                                          EP series         WHO series                               Q
                                                                            1/2 - EP series                          Q
                                                                            1- EP series                             Q
                                                          Workstations      Bucky table                              Q
                                                                            Bucky wall stand                         Q
                                                                            Bed                                      Q
                                                                            TOMO / Planigraphy                       Q
                                                          Startup message   POLYDOROS IT                             Q
                                                                            GEN IT                                   Q
                                                                            none                                     Q
POLYDOROS IT / IT-S                        COPL-136.843.03.01.02               Page 4 of 16                   Siemens AG
                                           08.05                               CS PS 212                  Medical Solutions
Standard Console Configuration Lists                                                             5
Servicemenue             Submenue 1        Submenue 2     Submenue 3/ 4
Configuration            Tube              Tube change    tube type _____________
Information: See the     Planigraphic      Type           By KK- Interface                 Q
Configuration Instruc-   equipment
tions.
                                                          Internal (60Hz)                  Q
                                                          Internal (50Hz)                  Q
                                           Times          Time A _____
                                                          Time B _____
                                                          Time C _____
                                                          Time D _____
                                                          Time E _____
                         Set DAP meter     No DAPM                                         Q
                         SW-dependant      DAPM Standard Resolution                        Q
                                           DAPM High Resolution                            Q
Siemens AG                  COPL-136.843.03.01.02                 Page 5 of 16   POLYDOROS IT / IT-S
Medical Solutions           08.05                                 CS PS 212
6                                             Standard Console Configuration Lists
Servicemenue          Submenue 1               Submenue 2                      Submenue 3/4
Adjustment            Tube adjustment          Tube warm up
Information: See                               Learn filament
the Adjustment
Instructions.         mAs relay adjust
                      Stat. inverter adjust
                      IONTOMAT                 Sensitivity                     Channel A              H : ___
                      Information: See the
                                                                               (Bucky table)          U : ___
                      Startup Instructions.
                                                                                                      D : ___
                                                                               Channel B         H : ___
                                                                               (Bucky wallstand) U : ___
                                                                                                      D : ___
                                               Corr. curve high (125 kV) 6 mm chamber                 H : ___
                                                                                                      U : ___
                                                                                                      D : ___
                                                                               12 mm chamber          H : ___
                                                                                                      U : ___
                                                                                                      D : ___
                                                                               HSE chamber            H : ___
                                                                                                      U : ___
                                                                                                      D : ___
                                               Corr. curve high (60 kV)        6 mm chamber           H : ___
                                                                                                      U : ___
                                                                                                      D : ___
                                                                               12 mm chamber          H : ___
                                                                                                      U : ___
                                                                                                      D : ___
                                                                               HSE chamber            H : ___
                                                                                                      U : ___
                                                                                                      D : ___
Various tests         Norminal power Information: See the Troubleshooting Guide.
                      SI: single oscillation Information: See the Troubleshooting Guide.
                      Iontomat drift           Drift bucky table Information: See the Startup Instructions.
                                               Drift bucky wall Information: See the Startup Instructions.
POLYDOROS IT / IT-S           COPL-136.843.03.01.02                          Page 6 of 16                    Siemens AG
                              08.05                                          CS PS 212                   Medical Solutions
Standard Console Configuration Lists                                                                      7
Servicemenue        Submenue 1            Submenue 2                       Submenue 3/4
Information         Error logInformation: See the Troubleshooting Guide.
                    Generator data Information: See the Configuration Instructions.
                    Tube Data Information: See the Configuration Instructions.
                    System data Information: See the Configuration Instructions.
Siemens AG                  COPL-136.843.03.01.02                       Page 7 of 16      POLYDOROS IT / IT-S
Medical Solutions           08.05                                       CS PS 212
8                                                                 Touch Panel Configuration List
3-
2Touch Panel Configuration List
    Service Menu                  Submenu 1        Submenu 2             Submenus 3/ 4
    Configuration                 Site Structure   Available worksta-    Bucky table                                    Q
    Information: See
                                                   tions                 Bucky wall stand                               Q
    the Configuration
                                                                         Bed/ Free Exposure                             Q
    Instructions.
                                                                         Planigraphy equipment/ Tomography Q
                                                   HV cable length       10 m                                           Q
                                                                         16 m                                           Q
                                                                         24 m                                           Q
                                                   Grid                  Stationary grid                                Q
                                                                         Moving grid                                    Q
                                                   Planigraphic equip- Type                  by KK- Interface           Q
                                                   ment                                      Internal (60Hz)            Q
                                                                                             Internal (50Hz)            Q
                                                   Planigraphic equip- configure             Time A                     ___
                                                   ment                (only with "KK        Time B                     ___
                                                                         Interface" Plani-
                                                                         graphic equip-      Time C                     ___
                                                                         ment)               Time D                     ___
                                                                                             Time E                     ___
                                                   Set DAP meter         No DAPM                                        Q
                                                   SW-dependant          DAPM Standard Resolution                       Q
                                                                         DAPM High Resolution                           Q
                                                   Set generator max. max. kV                _________________
                                                   values             max. P                 _________________
                                                   SW-dependant
                                                                         max. mA             _________________
                                                                         max. mAs            _________________
                                                   New tube              actual tube:        _________________
POLYDOROS IT / IT-S                      COPL-136.843.03.01.02                    Page 8 of 16                     Siemens AG
                                         08.05                                    CS PS 212                    Medical Solutions
Touch Panel Configuration List                                                                        9
Service Menu        Submenu 1       Submenu 2           Submenus 3/ 4
                    IONTOMAT        channel A           none                                    Q
                                                        HSE chamber                             Q
                                                        6 mm chamber                            Q
                                                        12 mm chamber                           Q
                                                        invert MF                               Q
                                    channel B           none                                    Q
                                                        HSE chamber                             Q
                                                        6 mm chamber                            Q
                                                        12 mm chamber                           Q
                                                        invert MF                               Q
Configuration       Control con-    EP series                            WHO series             Q
Information: See
                    sole Settings                                        1/2 - EP series        Q
the Configuration
                                                                         1- EP series           Q
Instructions.
                                    Starting message                     POLYDOROS              Q
                                                                         GEN                    Q
                                                                         none                   Q
                                    Display light       SW-depen-        10(min)...20(max)      ___
                                                        dant
                                    Language                             _________________
                                    Set date
                                    Tube load indicatior Display light   Show HU value          Q
                                                         tube load Indi- Tube load buzzer       Q
                                                         catior
                                    Organ Programs      Load default programs
                                                        Backup SW-dependant
                                                        Restore SW-dependant
                                    Further Settings    3-point Tech-    mAs                    Q
                                                        nique            mA/mAs                 Q
                                                        SW-dependant
                                                        Display          H _______________
                                                        SW-dependant
                                                                         U _______________
                                                                         D _______________
                                                        Display light    10(min)...20(max)      ____
                                                        SW-dependant
Siemens AG                 COPL-136.843.03.01.02               Page 9 of 16         POLYDOROS IT / IT-S
Medical Solutions          08.05                               CS PS 212
10                                              Touch Panel Configuration List
Servicemenue          Submenue 1         Submenue 2                  Submenue 3/ 4
Adjust                Tube Warm Up
Information: Siehe    Learn filament
Justieranleitung.
                      mAs- relay adjust
                      Iontomat Sen-      Channel A (Bucky table)     H                             ___
                      sitivity                                       U                             ___
                      Information: See
                                                                     D                             ___
                      the Startup
                      Instructions.      Channel B (Bucky wall       H                             ___
                                         stand)                      U                             ___
                                                                     D                             ___
                                         Corr. curve high (125       6 mm chamber    H             ___
                                         KV)/                                        U             ___
                                         Voltage coprrection 125                     D             ___
                                         KV
                                                                     12 mm chamber H               ___
                                                                                     U             ___
                                                                                     D             ___
                                                                     HSE chamber     H             ___
                                                                                     U             ___
                                                                                     D             ___
                                         Corr. curve high (60 KV)/ 6 mm chamber      H             ___
                                         Voltage coprrection                         U             ___
                                                                                     D             ___
                                                                     12 mm chamber H               ___
                                                                                     U             ___
                                                                                     D             ___
                                                                     HSE chamber     H             ___
                                                                                     U             ___
                                                                                     D             ___
                      Static inverter adjust
POLYDOROS IT / IT-S     COPL-136.843.03.01.02                    Page 10 of 16               Siemens AG
                        08.05                                    CS PS 212               Medical Solutions
Touch Panel Configuration List                                                                               11
Servicemenue             Submenue 1            Submenue 2                     Submenue 3/ 4
Diagnostic               Norminal power Information: See the Troubleshooting Guide.
                         Iontomat drift channel A Information: See the Startup Instructions.
                         Iontomat drift channel B Information: See the Startup Instructions.
                         SI: single oscillation Information: See the Troubleshooting Guide.
Info                     Error Log Information: See the Troubleshooting Guide.
Information: See the     Software version      Firmware Generator                                 ___________
Configuration Instruc-
tions.
                                               SW Console
                         System Info
                         Dongel Optionen
                         Tube Info
Siemens AG                 COPL-136.843.03.01.02                       Page 11 of 16           POLYDOROS IT / IT-S
Medical Solutions          08.05                                       CS PS 212
12                                                       Organ programs (with standard console)
4-
Bucky table organ program
3Organ programs (with standard console)
                                          Fig. 1:
POLYDOROS IT / IT-S                                 COPL-136.843.03.01.02   Page 12 of 16       Siemens AG
                                                    08.05                   CS PS 212       Medical Solutions
Organ programs (with standard console)                                         13
               Fig. 2:
Siemens AG               COPL-136.843.03.01.02   Page 13 of 16   POLYDOROS IT / IT-S
Medical Solutions        08.05                   CS PS 212
14                          Organ programs (with standard console)
Bucky wall stand organ program                                                 0
             Fig. 3:
POLYDOROS IT / IT-S    COPL-136.843.03.01.02   Page 14 of 16       Siemens AG
                       08.05                   CS PS 212       Medical Solutions
Organ programs (with standard console)                                         15
               Fig. 4:
Siemens AG               COPL-136.843.03.01.02   Page 15 of 16   POLYDOROS IT / IT-S
Medical Solutions        08.05                   CS PS 212
16                                                                  Changes to Previous Version
5-
4Changes to Previous Version
                               No changes; initial publication.
POLYDOROS IT / IT-S                         COPL-136.843.03.01.02         Page 16 of 16       Siemens AG
                                            08.05                         CS PS 212       Medical Solutions