C90 Specification

The C90 Patient Monitor is an advanced medical device that supports various monitoring functions including ECG, NIBP, and SPO2, with multiple measurement modes and adjustable settings. It complies with ISO 13485:2003 and MDD93/42/EEC safety standards, featuring a 17" color TFT touch screen and a range of interfaces for connectivity. The monitor provides detailed measurement capabilities for vital signs, including respiration, temperature, and cardiac output, with alarm systems for user-defined limits.

Uploaded by

ventas.seemid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views2 pages

C90 Specification

The C90 Patient Monitor is an advanced medical device that supports various monitoring functions including ECG, NIBP, and SPO2, with multiple measurement modes and adjustable settings. It complies with ISO 13485:2003 and MDD93/42/EEC safety standards, featuring a 17" color TFT touch screen and a range of interfaces for connectivity. The monitor provides detailed measurement capabilities for vital signs, including respiration, temperature, and cardiac output, with alarm systems for user-defined limits.

Uploaded by

ventas.seemid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Printer: External printer supported Method Automatic oscillometric

C90 Patient Monitor Respiration Work mode: Manual / Automatic/Continuous

Safety Standards Method: impedance method Measurement Time: Adjustable (1-480min)

ISO 13485:2003 approved, CE marking according to RR measurement Adult: 0-120bpm Measurement Unit: mmHg / Kpa selectable

MDD93/42/EEC range: Neonate: 0 -150bpm Measurement types: Systolic, Diastolic, Mean

Physical Characteristics Resolution: 1 rpm Range of systolic Adult Mode:40-270mmHg

Product Size: 400*400*180 Accuracy: 7-150rpm: ± 1rpm or 1%, pressure: Pediatric Mode:40-200mmHg

Net Weight: 10kg(standard configuration) whichever is greater Neonate Mode 40-135mmHg

Display: 17” color TFT touch screen 0-6rpm: unspecified Range of diastolic Adult Mode:10-215mmHg

Resolution: 1280x1024 RESP Apnea Alarm: 10s-40s pressure: Pediatric Mode:10-150mmHg

Trace 12 waveforms Alarm: Audible and visual alarm; alarm Neonate Mode 10-100mmHg

Sweep Speed: 6.25mm/s 12.5mm/s, 25mm/s, events recallable Range of mean Adult Mode:20-235mmHg

50mm/s Sweep Speed: 12.5、25、50mm/s pressure: Pediatric Mode:20-165mmHg

Operation Environment Gain Selection: X0.25, X0.5, X1, X2 Neonate Mode 20-110mmHg

Temperature: 0-40℃ ECG Over-pressure both Hardware and software

Humidity: 15-85% Lead Type Cardio TecTM 12-leads ECG protection: over pressure protection

Power Supply AC100-250V, 50/60Hz Analysis, 5 Lead and 3 lead Accuracy: Less than 5mmHg

Battery Type: Rechargeable plug & play battery selectable Resolution 1mmHg

Lithium-ion 12-lead cable I; II; III; aVR; aVL;aVF; V1-V6. Alarm Systolic, Diastolic, Mean

Battery Capacity: 4000mA 5-lead cable: RA; LA; RL; LL; V or R; L; N; F; C PR from NIBP: 40-240bpm

Battery Recharging Maximum 6.5 hours for charging; 3-lead cable: RA; LA; LL or R; L; F Nellcor SPO2

Time: Lead selection: 12-Lead I; II; III; aVR; aVL;aVF; Measurement & alarm range: 0~100%

Battery backup: 4 hours for continuous working V1-V6. Resolution: 1%

Interface A. USB interface, mouse, 5-lead: I; II; III; aVR; aVL Accuracy: ±2% (70-100%, MAX-A, MAX-AL,

keyboard and PCL 3-lead: I; II; III MAX-N, MAX-P, MAX-I and

printer can be Gain Selection X 0.125, X0.25, X0.5, X1, X2, MAX-FAST sensors);

connected X4,auto ±3% (70-100%, D-YS, DS-100A,

B. RJ45 Ethernet Sweep Speed 6.25,12.5, 25, 50mm/s OXI-A/N and OXI-P/I sensors);

interface Heart Rate Range Adult: 15-300bpm 0-69% unspecified

C. SD card interface Pediatric/Neonate:15-350bpm PR Measurement 20~300bpm

D. Nurse Call interface。 Resolution: 1 bpm Range:

E. AC interface Protection: Withstand 4000VAC/50Hz Resolution: 1bpm

F. Grounding pole voltage in isolation ,Again Accuracy: ±3bpm

G. synchronization electrosurgical interference and Alarm range: 20-250bpm

defibrillation interface。 defibrillation Masimo SPO2

H. DVI-D interface Accuracy: ±1% or ±1bpm (whichever is Measurement & 1~100%

I. Multi-function greater) alarm range

interface to connect Filter ECG enlarge width: Resolution: 1%

with sub-monitor and MON: 0.5-55Hz Accuracy: ±2% (70~100%,Ped, non-motion+

plugin slot DIA: 0.05-150Hz ±3% (70-100%, Neo,

J. Wifi module OPE:1-20Hz non-motion);

K. IR module interface, it ST SEGMENT -2.0mV - +2.0Mv (Automatic) 0-69% unspecified

supports the following detection: Alarm range 0~100%

modules: CO2, dual Arrhythmia Analysis : Yes Pulse rate: Range: 25~240bpm

IBP, AG, ICG pacemaker detection: detectable Resolution:1bpm

Alarm: Yes, audible and visual alarm, Accuracy: ±3bpm(non-motion)


Recorder: Waveform: 2channels
alarm events recallable ±5bpm(motion)
Built-in; thermal array
12 lead ECG Analysis: yes Alarm range:25~240bpm
2 waveforms
Speed:25mm/s,50mm/s NIBP Comen SPO2
Record width:50mm
Measurement & 1~100% Range: C.O.:1.4~15L/min

alarm range Alarm Range: -50mmHg~300mmHg Accuracy: SV:unspecified

Resolution: 1% Accuracy: ±2% or ±1mmHg, whichever is HR: ±2bpm

Accuracy: ±2% (70~100%,Ped, non-motion+ greater C.O:unspecified

±3% (70-100%, Neo, Channel 4 channels Alarm range: CI: HI (LO+0.1)~15.0 L/min/m2

non-motion); Multi-Gas/O2 LO 0~(HI-0.1)L/min/m2

0-69% unspecified Method: Infrared Absorption TFC: HI (LO+1)~150/KΩ

Alarm range 0~100% Gas sorts: CO2,N2O,Des,Iso,Enf,Sev,Hal,O2 LO 10~(HI-1) KΩ

Pulse rate: Range: 20~300bpm (optional paramagnetic sensor) Alarm Deviation CI:±01. L/min/m2

Resolution:1bpm Measurement range: CO2 : 0-15 vol% ±(0.2 vol% + TFC:±1 KΩ

Accuracy: ±3bpm(non-motion) 2 % of the reading) Bispectral Index(IOC)

±5bpm(motion) N2O: 0-100 vol% ±(2 vol% + Measurement range: IOC:0-99

Alarm range:20~250bpm 2 % of the reading) SQ I:0-100%

EtCO2(Sidestream) HAL, ISO, ENF: 0-8 vol% ±(0.15 EMG:0-100dB

CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to vol% + 5 % of the reading) ESR:0-100%

Range: 20kPa (at 760mmHg) SEV : 0-10 vol% ±(0.15 vol% + IOC Alarm: HI limit:(Lo limit+2)~99

Accuracy: ± 2 mm Hg (0 – 40 mm Hg) 5 % of the reading) Lo limit: 0~(HI limit-2)

± 5% of reading (41 – 70 mm Hg) DES: 0-22 vol% ±(0.15 vol% + Total index update 8s

± 8% of reading (71 –100 mm Hg) 5 % of the reading) delay:


± 10% of reading (101 –150 mm O2: 0-100vol% ±(1 vol% + 2 % EEG sampling 2048 Hz, 16 bits

Hg) of the reading) frequency:


Respiration rate: 2-120bpm Data output: Fi and Et values CMRR: >140 dB
RR accuracy: ±2rpm (0-70rpm) Event Marker: yes
Respiratory rate: 0-150 bpm
±5rpm (>70rpm) Sweep speeds: 12.5/25/50mm/sec
Preheating time: ISA CO2:< 10s,ISA OR+/AX+:<
Response time: <240msec (10% to 90%) Standard Configuration 1:
20s
Delay time: <2s 5-lead ECG,RESP, Dual-Temp, Comen SPO2,NIBP,Reserved
Alarm: User selectable alarm limits for
EtCO2(mainstream) EtCO2 interface,
all measurement
CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to 20kPa Standard Configuration 2:
others: Up to 4 waveforms displayed
Range: (at 760mmHg) 12-lead ECG,RESP, Dual-Temp, Masimo SPO2,NIBP,Reserved
Agent mixture detection
Accuracy: ± 2 mm Hg (0 – 40 mm Hg) EtCO2 interface,
MAC value displayed
± 5% of reading (41 – 70 mm Hg) Optional:
Cardiac Output
± 8% of reading (71 –100 mm Hg) EtCO2 module, Nellcor SPO2, packet, External battery,
Method: Thermodilution
± 10% of reading (101 –150 mm Hg) 4-IBP, ICG,AG,IOC,C.O.
Measurement range: C.O.:0.1~20L/min
Respiration rate: 0-120rpm
BT: 25~43℃
Respiration rate ±2rpm (0-70rpm)
IT: 0~25℃
accuracy: ±5rpm (>70rpm)
Resolution: C.O.:0.1L/min
Delay time: <2s
BT、IT:0.1℃
Temperature (Dual Channel)
Accuracy: C.O. : ±5% or ±0.1 L/min ,
Measurement range: 0-50 C
whichever is greater
TEMP sensor: Standard configuration- skin
BT、IT: ±0.1℃(no sensor)
TEMP sensor,
Alarm Range: BT Hi limit: (LO limit +0.1)~
Resolution: 0.1 C
(C.O.) 43℃
Accuracy: 0.1 C (exclusive of error of
BT Lo limit:23.0~(Hi limit-0.1)℃
sensor)
Step: 0.1℃
Channel: T1, T2, TD (Temperature
Impedance Cardiography (ICG)
Difference)
Method: Thoracic Bio-impedance
IBP
measurement
Measured Pressure AVP, CVP, PAR, LAP, RAP, ICP
Measurement range: SV:5~250 ml/b
Measurement -50mmHg~300mmHg
HR:40~250 bpm