Printer: External printer supported Method Automatic oscillometric
C90 Patient Monitor Respiration Work mode: Manual / Automatic/Continuous
Safety Standards Method: impedance method Measurement Time: Adjustable (1-480min)
ISO 13485:2003 approved, CE marking according to RR measurement Adult: 0-120bpm Measurement Unit: mmHg / Kpa selectable
MDD93/42/EEC range: Neonate: 0 -150bpm Measurement types: Systolic, Diastolic, Mean
Physical Characteristics Resolution: 1 rpm Range of systolic Adult Mode:40-270mmHg
Product Size: 400*400*180 Accuracy: 7-150rpm: ± 1rpm or 1%, pressure: Pediatric Mode:40-200mmHg
Net Weight: 10kg(standard configuration) whichever is greater Neonate Mode 40-135mmHg
Display: 17” color TFT touch screen 0-6rpm: unspecified Range of diastolic Adult Mode:10-215mmHg
Resolution: 1280x1024 RESP Apnea Alarm: 10s-40s pressure: Pediatric Mode:10-150mmHg
Trace 12 waveforms Alarm: Audible and visual alarm; alarm Neonate Mode 10-100mmHg
Sweep Speed: 6.25mm/s 12.5mm/s, 25mm/s, events recallable Range of mean Adult Mode:20-235mmHg
50mm/s Sweep Speed: 12.5、25、50mm/s pressure: Pediatric Mode:20-165mmHg
Operation Environment Gain Selection: X0.25, X0.5, X1, X2 Neonate Mode 20-110mmHg
Temperature: 0-40℃ ECG Over-pressure both Hardware and software
Humidity: 15-85% Lead Type Cardio TecTM 12-leads ECG protection: over pressure protection
Power Supply AC100-250V, 50/60Hz Analysis, 5 Lead and 3 lead Accuracy: Less than 5mmHg
Battery Type: Rechargeable plug & play battery selectable Resolution 1mmHg
Lithium-ion 12-lead cable I; II; III; aVR; aVL;aVF; V1-V6. Alarm Systolic, Diastolic, Mean
Battery Capacity: 4000mA 5-lead cable: RA; LA; RL; LL; V or R; L; N; F; C PR from NIBP: 40-240bpm
Battery Recharging Maximum 6.5 hours for charging; 3-lead cable: RA; LA; LL or R; L; F Nellcor SPO2
Time: Lead selection: 12-Lead I; II; III; aVR; aVL;aVF; Measurement & alarm range: 0~100%
Battery backup: 4 hours for continuous working V1-V6. Resolution: 1%
Interface A. USB interface, mouse, 5-lead: I; II; III; aVR; aVL Accuracy: ±2% (70-100%, MAX-A, MAX-AL,
keyboard and PCL 3-lead: I; II; III MAX-N, MAX-P, MAX-I and
printer can be Gain Selection X 0.125, X0.25, X0.5, X1, X2, MAX-FAST sensors);
connected X4,auto ±3% (70-100%, D-YS, DS-100A,
B. RJ45 Ethernet Sweep Speed 6.25,12.5, 25, 50mm/s OXI-A/N and OXI-P/I sensors);
interface Heart Rate Range Adult: 15-300bpm 0-69% unspecified
C. SD card interface Pediatric/Neonate:15-350bpm PR Measurement 20~300bpm
D. Nurse Call interface。 Resolution: 1 bpm Range:
E. AC interface Protection: Withstand 4000VAC/50Hz Resolution: 1bpm
F. Grounding pole voltage in isolation ,Again Accuracy: ±3bpm
G. synchronization electrosurgical interference and Alarm range: 20-250bpm
defibrillation interface。 defibrillation Masimo SPO2
H. DVI-D interface Accuracy: ±1% or ±1bpm (whichever is Measurement & 1~100%
I. Multi-function greater) alarm range
interface to connect Filter ECG enlarge width: Resolution: 1%
with sub-monitor and MON: 0.5-55Hz Accuracy: ±2% (70~100%,Ped, non-motion+
plugin slot DIA: 0.05-150Hz ±3% (70-100%, Neo,
J. Wifi module OPE:1-20Hz non-motion);
K. IR module interface, it ST SEGMENT -2.0mV - +2.0Mv (Automatic) 0-69% unspecified
supports the following detection: Alarm range 0~100%
modules: CO2, dual Arrhythmia Analysis : Yes Pulse rate: Range: 25~240bpm
IBP, AG, ICG pacemaker detection: detectable Resolution:1bpm
Alarm: Yes, audible and visual alarm, Accuracy: ±3bpm(non-motion)
Recorder: Waveform: 2channels
alarm events recallable ±5bpm(motion)
Built-in; thermal array
12 lead ECG Analysis: yes Alarm range:25~240bpm
2 waveforms
Speed:25mm/s,50mm/s NIBP Comen SPO2
Record width:50mm
Measurement & 1~100% Range: C.O.:1.4~15L/min
alarm range Alarm Range: -50mmHg~300mmHg Accuracy: SV:unspecified
Resolution: 1% Accuracy: ±2% or ±1mmHg, whichever is HR: ±2bpm
Accuracy: ±2% (70~100%,Ped, non-motion+ greater C.O:unspecified
±3% (70-100%, Neo, Channel 4 channels Alarm range: CI: HI (LO+0.1)~15.0 L/min/m2
non-motion); Multi-Gas/O2 LO 0~(HI-0.1)L/min/m2
0-69% unspecified Method: Infrared Absorption TFC: HI (LO+1)~150/KΩ
Alarm range 0~100% Gas sorts: CO2,N2O,Des,Iso,Enf,Sev,Hal,O2 LO 10~(HI-1) KΩ
Pulse rate: Range: 20~300bpm (optional paramagnetic sensor) Alarm Deviation CI:±01. L/min/m2
Resolution:1bpm Measurement range: CO2 : 0-15 vol% ±(0.2 vol% + TFC:±1 KΩ
Accuracy: ±3bpm(non-motion) 2 % of the reading) Bispectral Index(IOC)
±5bpm(motion) N2O: 0-100 vol% ±(2 vol% + Measurement range: IOC:0-99
Alarm range:20~250bpm 2 % of the reading) SQ I:0-100%
EtCO2(Sidestream) HAL, ISO, ENF: 0-8 vol% ±(0.15 EMG:0-100dB
CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to vol% + 5 % of the reading) ESR:0-100%
Range: 20kPa (at 760mmHg) SEV : 0-10 vol% ±(0.15 vol% + IOC Alarm: HI limit:(Lo limit+2)~99
Accuracy: ± 2 mm Hg (0 – 40 mm Hg) 5 % of the reading) Lo limit: 0~(HI limit-2)
± 5% of reading (41 – 70 mm Hg) DES: 0-22 vol% ±(0.15 vol% + Total index update 8s
± 8% of reading (71 –100 mm Hg) 5 % of the reading) delay:
± 10% of reading (101 –150 mm O2: 0-100vol% ±(1 vol% + 2 % EEG sampling 2048 Hz, 16 bits
Hg) of the reading) frequency:
Respiration rate: 2-120bpm Data output: Fi and Et values CMRR: >140 dB
RR accuracy: ±2rpm (0-70rpm) Event Marker: yes
Respiratory rate: 0-150 bpm
±5rpm (>70rpm) Sweep speeds: 12.5/25/50mm/sec
Preheating time: ISA CO2:< 10s,ISA OR+/AX+:<
Response time: <240msec (10% to 90%) Standard Configuration 1:
20s
Delay time: <2s 5-lead ECG,RESP, Dual-Temp, Comen SPO2,NIBP,Reserved
Alarm: User selectable alarm limits for
EtCO2(mainstream) EtCO2 interface,
all measurement
CO2 Measurement 0 -150 mm Hg, 0 to 79%, 0 to 20kPa Standard Configuration 2:
others: Up to 4 waveforms displayed
Range: (at 760mmHg) 12-lead ECG,RESP, Dual-Temp, Masimo SPO2,NIBP,Reserved
Agent mixture detection
Accuracy: ± 2 mm Hg (0 – 40 mm Hg) EtCO2 interface,
MAC value displayed
± 5% of reading (41 – 70 mm Hg) Optional:
Cardiac Output
± 8% of reading (71 –100 mm Hg) EtCO2 module, Nellcor SPO2, packet, External battery,
Method: Thermodilution
± 10% of reading (101 –150 mm Hg) 4-IBP, ICG,AG,IOC,C.O.
Measurement range: C.O.:0.1~20L/min
Respiration rate: 0-120rpm
BT: 25~43℃
Respiration rate ±2rpm (0-70rpm)
IT: 0~25℃
accuracy: ±5rpm (>70rpm)
Resolution: C.O.:0.1L/min
Delay time: <2s
BT、IT:0.1℃
Temperature (Dual Channel)
Accuracy: C.O. : ±5% or ±0.1 L/min ,
Measurement range: 0-50 C
whichever is greater
TEMP sensor: Standard configuration- skin
BT、IT: ±0.1℃(no sensor)
TEMP sensor,
Alarm Range: BT Hi limit: (LO limit +0.1)~
Resolution: 0.1 C
(C.O.) 43℃
Accuracy: 0.1 C (exclusive of error of
BT Lo limit:23.0~(Hi limit-0.1)℃
sensor)
Step: 0.1℃
Channel: T1, T2, TD (Temperature
Impedance Cardiography (ICG)
Difference)
Method: Thoracic Bio-impedance
IBP
measurement
Measured Pressure AVP, CVP, PAR, LAP, RAP, ICP
Measurement range: SV:5~250 ml/b
Measurement -50mmHg~300mmHg
HR:40~250 bpm