Technical data
5560A High-Performance Multi-Product Calibrator
5550A Performance Multi-Product Calibrator
5540A Multi-Product Calibrator
                                                             5560A: The next generation
                                                             high-performing calibrator
                                                             supporting the widest
                                                             workload coverage
                                                             The 5560A Calibrator defines a new
                                                             class of high-performance multi-product
Most comprehensive workload coverage, latest                 calibrator, providing the broadest
technology, intuitive redesigned front panel,                electrical workload coverage and
MET/CAL™ compatibility and much more                         highest accuracy for calibrating the most
                                                             demanding modern workloads.
5560A: The most comprehensive workload coverage
The 5560A calibrates the most popular benchtop 6.5-digit     5550A: Optimized for your
multimeters with better than 4:1 test uncertainty ratio      multimeter workload
(TUR), oscilloscopes to 2 GHz, and clamp meters to 1500 A.
                                                             The 5550A Performance Multi-Product
Technical improvements include 30 A continuous current       Calibrator enhances the 5522A with new
output with no duty cycle and synthesized inductance         calibration ranges optimized to better
functionality. These improvements enable you to calibrate    match your existing digital multimeter
modern and full-functional benchtop multimeters and          workload in a modern, ruggedized
clamp meters. Oscilloscope bandwidth to 2 GHz and edge       instrument with intuitive graphical
rise time of <175 pS allows the 5560A to handle an even      interface.
broader workload. A large variety of thermocouple types
and a new thermocouple connector enables easier connec-      5540A: Better performance for
tion and broadens the temperature workload coverage. The
workload is expanded even further when the 5560A is used
                                                             on-site or mobile calibration
with a 52120A amplifier and appropriate coil to increase     The 5540A Multi-Product Calibrator
the current output to 6000 A, for calibrating high-current   extends the capabilities of the 5502A with
devices such as Rogowski coils.                              better performance suited for on-site or
                                                             mobile calibration.
5550A: Optimized for your multimeter workload
The 5550A Performance Multi-Product Calibrator enhances the
5522A Multi-Product Calibrator with new calibration ranges
optimized to better match your existing digital multimeter
workload in a modern, ruggedized instrument with an intuitive
graphical interface.
It calibrates the most popular benchtop digital multimeters with
improved test uncertainty ratios (TURs), oscilloscopes to 1 GHz,
and clamp meters to 1500 A with continuous current output.
Technical improvements include 30 A continuous current output,
which reduces wait time during heavy usage. A range redesign
enables you to calibrate your existing benchtop multimeters with
greater confidence. A larger variety of thermocouple types and
a new thermocouple connector enables easier connection and
                                                                                       The 5560A provides the broadest workload coverage, including
broadens the temperature workload coverage. The workload is                            most 6.5-digit multimeters.
expanded even further when the 5550A is used with a 52120A
amplifier to increase the current output to 6000 A, for calibrating
high-current components such as Rogowski coils.
                                                                                       Match your setup to your application
                                                                                       A variety of options and accessories lets you
                                                                                       match your setup to your applications. An
                                                                                       optional portability kit makes the 5560A,
                                                                                       5550A or 5540A an excellent fit for on-site or
                                                                                       mobile calibration. The DMM AUTOCAL Adapter
                                                                                       minimizes lead changes during digital multimeter
                                                                                       calibration, increasing efficiency without
                                                                                       sacrificing and compromising accuracy. The
                                                                                       portability kit provides ruggedized handles and
                                                                                       bumpers, including protection for the front panel
                                                                                       with a cover that also acts as storage for cables
                                                                                       and accessories.
The 5560A provides the broadest workload coverage, including oscilloscopes to 2 GHz.
5540A: Better performance for on-site or mobile calibration
The 5540A Multi-Product Calibrator extends the capabilities of
the 5502A Multi-Product Calibrator with better performance
suited for on-site or mobile calibration, covering many of the most
demanding field instrumentation workloads. It calibrates the
most popular handheld digital multimeters with increased test
uncertainty ratios (TURs), oscilloscopes to 600 MHz, and clamp
meters to 1500 A with continuous current output.
Technical improvements include a current range increase from
20 A to 30 A of continuous current output, which reduces wait
time during heavy usage. A range redesign enables you to
calibrate your existing handheld digital multimeters with greater
confidence. A larger variety of thermocouple types and a new
                                                                                       The 5540A calibrator offers better performance suited for on-site
thermocouple connector enables easier connection and broadens                          or mobile calibration
the temperature workload coverage. The workload is expanded
even further when the 5540A is used with the 52120A amplifier to
increase the current output to 6000 A, for calibrating high-current
components such as Rogowski coils.
2 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Workload is expanded even further when the 5560A is used with a 52120A Transconductance Amplifier to
increase the current output to 6000 A, for calibrating high-current components such as Rogowski coils.
                                                52120A Transconductance Amplifier
Key features and benefits
 Comparing the 5560A, 5550A, and 5540A
 Feature                                                   5560A                               5550A                             5540A
 4:1 test TUR for most popular                                •
 6.5-digit multimeters
 30 A continuous current output                               •                                   •                                 •
 extends AC/DC measurement ranges
 Calibrate meters that measure AC/DC                          •                                   •                                 •
 voltage, resistance and capacitance
 Calibrate meters that measure                                •                                   •
 inductance
 Ranging optimized to better match
 your existing digital multimeter                             •                                   •                                 •
 workload
 New optional 1-, 2-, 10-turn and
 redesigned 50-turn current coils                             •                                   •                                 •
 expand workload coverage even
 further
 17.8 centimeter (7-inch) color touch
 screen with new graphical user                               •                                   •                                 •
 interface provides an intuitive
 calibration experience
 Optional DMM AUTOCAL Adapter
 to calibrate digital multimeters with                        •                                   •                                 •
 minimal-to-no lead changes
 Visual Connection Management™
 output terminals guide connections,                          •                                   •                                 •
 preventing connection errors
 Reverse power protection prevents                            •                                   •                                 •
 costly operator errors
 Oscilloscope calibration options                        Up to 2 GHz                        Up to 1 GHz                     Up to 600 MHz
 expand workload coverage
3 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Calibrate a wide workload of modern test instruments
Calibrating digital multimeters
4:1 test uncertainty ratio                                       Inductance sourcing expands 5560A and
The 5560A calibrates a complete range of                         5550A workload coverage
electrical workload, but it is especially ideal as               A new inductance sourcing function expands
a 6.5-digit multimeter calibrator, with a 4:1 test               workload coverage to more types of modern
uncertainty ratio (TUR) for most popular bench-                  digital multimeters.
top models.
The 5550A is functionally similar to the Fluke                   Digital-to-analog converter design
Calibration 5522A Multi-Product Calibrator;                      independent of switch resistance
however, this new model has been enhanced                        A new patented ultra-linear digital-to-analog
with the latest technology and usability features.               design enables the 5560A, 5550A and 5540A to
It calibrates most 5.5-digit multimeters and even                achieve performance specifications that were
some 6.5-digit multimeters with a 4:1 TUR across                 not possible in the 5522A and 5502A, allowing
its measurement range.                                           you to calibrate a more accurate and demanding
                                                                 workload.
The 5540A Multi-Product Calibrator extends the
workload capabilities of the 5502A Multi-Product
Calibrator, improving performance suited for                     Optimized ranging for complete
real-time demand on-site or mobile calibration.                  workload coverage
It calibrates most 4.5-digit multimeters with a 4:1
                                                                 “Ranging” refers to the range over which a
TUR across its measurement range.
                                                                 particular specification applies.
A 4:1 TUR enables you to quickly meet or exceed
                                                                 In the 5522A and 5502A calibrators, ranging
manufacturers’ specifications for calibrating
                                                                 occurs in multiples of 3.3x; however, most bench
digital multimeters without guardbanding and
                                                                 top multimeters typically range at 1.2x. Since
the need for additional equipment. This simpli-
                                                                 ranging was different in these older models, at
fies setup and reduces the number of standards
                                                                 some points the calibrator alone is not optimized
required to calibrate the most demanding digital
                                                                 to calibrate the digital multimeter at its ideal
multimeters.
                                                                 specification point.
4 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
The 5560A, 5550A and 5540A are now optimized                     and 5540A, all the terminals are dedicated and
to match the range switching of the most                         the guard terminal is moved to the side, enabling
popular 6.5-digit, 5.5-digit and 4.5-digit DMMs.                 you to connect the leads once and complete the
These ranging improvements enable you to                         meter calibration efficiently.
calibrate more of your multimeter workload with
a single calibrator.
                                                                 High-quality lead set included; optional
                                                                 DMM AUTOCAL Adapter for dedicated
Fast settling time                                               multimeter calibration
Calibrate multimeters significantly faster with                  5560A, 5550A and 5540A ship with a Fluke
improved settling time in the 5560A, 5550A and                   Calibration lead set that gives you a high-quality
5540A. In some cases, these new calibrators                      connection, matched to your calibrator.
settle 50 % faster than previous models. You’ll
have less wait time and more time actually                       An optional DMM AUTOCAL Adapter lets
performing the tests.                                            you easily dedicate the calibrator to a digital
                                                                 multimeter workload. The adapter plugs directly
                                                                 into the calibrator’s output terminals and gives
Re-mapped output terminals limits lead                           you the same functionality as the included leads
changes                                                          but with greater convenience and efficiency,
We’ve re-mapped the output terminals on the                      reducing user error.
5560A, 5550A and 5540A, decoupling Aux and
Sense outputs, making it possible to calibrate
                                                                 Optional DMM
most workloads with minimal lead changes.                        AUTOCAL Adapter
                                                                 lets you dedicate
The new terminal layout marks a distinct                         the calibrator to a
improvement over older models. The 5522A and                     digital multimeter
                                                                 workload.
5502A, for example, has shared Sense and AUX
terminals, as well as shared ground and guard,
so you have to change leads frequently during
a multimeter calibration. On the 5560A, 5550A
Digital multimeter calibration features
 Comparing the 5560A, 5550A, and 5540A
 Feature                                                 5560A                             5550A                               5540A
 Calibrate 6.5-digit multimeters that
 measure voltage, current, resistance,                      •
 capacitance and inductance
 4:1 test uncertainty ratio for most                        •
 popular 6.5-digit multimeters
 4:1 test uncertainty ratio for most                        •                                 •
 popular 5.5-digit multimeters
 4:1 test uncertainty ratio for most                        •                                 •                                   •
 popular 4.5-digit multimeters
 Calibrate 5.5-digit multimeters that
 measure voltage, current, resistance,                      •                                 •
 capacitance and inductance
 Calibrate with improved settling time                      •                                 •                                   •
 New output terminal layout optimized                       •                                 •                                   •
 for digital multimeter calibration
 Optional DMM AUTOCAL Adapter
 accessory for dedicated digital                            •                                 •                                   •
 multimeter calibration
5 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
                      Calibrating clamp meters and ammeters
                      The increased 30 A output enables you to use the 5560A, 5550A,
                      and 5540A as a 30 A calibrator for higher current workloads, such
                      as clamp meters up to 1500 A (with optional current coil).
                      Continuous output means you don’t need to put the calibrator on
                      standby for cool down periods while using the current function.
                      That lets you increase throughput, which can be a real time-saver
                      if you calibrate a lot of ammeters.
                      A new optional 1-, 2-, 10-turn current coil and a redesigned 50-turn
                      current coil work with the 5560A, 5550A and 5540A to enable you
                      to calibrate workload that includes clamp-type current meters
                      and oscilloscope current probes. Each coil, like the calibrator, is
                      designed for continuous use at 30 A with a minimum duty cycle
                      which improves calibration throughput as much as four times.
                      Expand workload coverage even more. Use the 5560A, 5550A or
                      the 5540A with the Fluke Calibration 52120A Transconductance
                      Amplifier to increase the current output to 6000 A, ideal for
                      calibrating high-current components such as Rogowski coils.
6 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Clamp meter calibration features
 Comparing the 5560A, 5550A, and 5540A
 Feature                                                       5560A                                 5550A                                5540A
 30 A continuous current AC/DC
 output, extending the calibrator's                               •                                     •                                    •
 current ranges
 New optional 1, 2, 10-turn and                                   •                                     •                                    •
 redesigned 50-turn current coils
 Expand workload coverage                                         •                                     •                                    •
 Get enhanced throughput by avoiding                              •                                     •                                    •
 duty cycling
 Calibrate a wider range of workload,
 including oscilloscope current probes                            •                                     •                                    •
 at various ranges
 Use with the 52120A Transconduc-
 tance Amplifier to boost current                                 •                                     •                                    •
 output to 6000 A
A new optional 1-, 2-, 10-turn current coil (left) and a redesigned 50-turn current coil (right) work with the 5560A, 5550A and 5540A, enabling you to calibrate
workload that includes clamp-type current meters and oscilloscope current probes.
7 Fluke Corporation     5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
                      Calibrate oscilloscopes
                      Three options provide capabilities to calibrate oscilloscopes to 2 GHz with the 5560A;
                      1 GHz with the 5550A; or 600 MHz with the 5540A. Easily verify dynamic response,
                      bandwidth, timing, multiple triggering functions, input resistance and more.
                      Rise time is a crucial oscilloscope calibration specification. An oscilloscope should
                      have fast rise time for it to capture rapid transitions; otherwise, the results could be
                      misleading and significant information may not be displayed. The 5560A, 5550A, and
                      5540A calibrators feature a faster edge specification to enable coverage of a wide
                      variety of oscilloscopes. You can accurately source a rapid transition to calibrate
                      fast edge rise times in modern oscilloscopes. Edge is less than 175 pS, a 58%
                      improvement from the 5522A calibrator.
                      The 5560A, 5550A and 5540A also include improved leveled sine wave output. SSB
                      phase noise is now specified in each model, allowing you to see a more accurate
                      output signal. The source VSWR is also specified and verified. These improved
                      specifications, when combined with leveled sine, allow calibration of increasingly
                      demanding workload.
                      Using the options to calibrate oscilloscopes lets you simplify operator training
                      because technicians only need to learn to use one calibrator.
8 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Oscilloscope calibration features
 Comparing the 5560A, 5550A, and 5540A
 Feature                                                         5560A                                5550A                      5540A
 600 MHz oscilloscope calibration                                   •                                    •                          •
 option.
 1 GHz oscilloscope calibration option                              •                                    •
 2 GHz oscilloscope calibration option                              •
 ≤ 175 ps Edge Rise Time                                            •                                    •                          •
 Improved leveled sine wave specifications                          •                                    •                          •
Rugged design for laboratories or on-site work
Reverse power protection without false tripping
The 5560A, 5550A and 5540A provide reverse power protection and immediate output disconnection on the output
terminals for all functions. The protections apply to external voltages up to
300 Vpk and help protect the calibrator’s internal circuitry from costly operator error—preventing damage and keeping
the calibrator up and running.
1000 V direct amplifier
A newly designed amplifier enables the calibrator to generate low frequency AC voltages without the use of a
transformer.
Optional portability kit
For those who work in the field, the portability kit protects the calibrator and makes it easier to transport. The kit
includes
front/rear bumpers and an easy-grip side handle.
A transit case (included) is designed for shipping the calibrator, with or without the portability kit.
                                 The optional portability kit protects the calibrator and makes it easier to transport.
9 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
                         Visual Connection                                                               OPERATE and STANDBY modes
                         Management™ terminals                                                           OPERATE illuminates when the output terminals are
                         Light up to indicate active terminals,                                          active. STANDBY illuminates when the terminals are
                         helping you know which connection                                               not active.
                         to make
                                 Isolated                         Touch screen display
                                 terminal block                   Easy-to-read intuitive menu                    Calculator keyboard
                                 New terminal layout              structure lets you access any                  A simple calculator-style
                                 optimized for digital            feature within three button                    keyboard makes it easy to
                                 multimeter calibration           presses or less                                enter values quickly
                                 with minimal lead changes
                                                                                                                                                  Output
                                                                                                                                                  units
                                                                                                                                                  Select output
                                                                                                                                                  units easily after
                                                                                                                                                  entering the
                                                                                                                                                  value
                                                                                                                                                  Multiplier
                                                                                                                                                  keys
                                                                                                                                                  These keys let
                                                                                                                                                  you conveniently
                                                                                                                                                  step a measure-
                                                                                                                                                  ment up or down
Thermocouple                       Trigger                 Scope output               USB                        Output dial
connector                          BNC connector is        Type N connector           Calibration reports        To adjust the reading, simply
New thermocouple                   used to trigger the     is used for outputs        can be stored on USB       rotate the output dial and the
connector lets you connect         oscilloscope during     during oscilloscope        memory sticks for          error is displayed directly in
multiple types of thermocouple     oscilloscope calibra-   calibrations. Active       easy transfer to a PC      ppm or percent
types, including bare wire.        tions. Active with      with option installed
                                   option installed
                              Power switch                                  Internal circuit boards
                              A power switch automatically senses           Internal printed circuit boards
                              and adapts to the incoming mains              feature the latest digital design
                              power and frequency                           technology
                                                   Multi-interface                                              Compatibility
                                                   Ethernet, RS-232, GPIB                                       Compatible with the Fluke
                                                   and USB interfaces                                           Calibration 52120A Amplifier
  10 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Features you expect from a modern instrument
Front and rear panel improvements
Visual Connection Management™ output
terminals light up to indicate which terminals are
active, guiding the user to make the correct con-
nections and reducing user error.
USB ports are placed both on the front and rear
of the unit. Use the port at the front to download
internal calibration constants; use the rear port
for remote communication with a PC—or choose
the LAN, IEEE or serial interfaces.
For previous 55XXA users, the 5560A, 5550A
and 5540A maintain many front-panel details
that characterize their predecessors, including
the calculator-style keyboard for entering values
easily, an output dial for varying output and keys               Visual Connection Management output terminals guide the user to make the
for selecting common parameters with a single                    correct connections.
touch.
Graphical user interface optimized for
touchscreen use
A 17.8 centimeter (7-inch) graphical user interface
offers intuitive menus that are easy to navigate
and read, providing access to common func-
tions with the touch of a finger and eliminating
the menu scrolling that was required in previous
55XXA models.
The screen displays all of the information you
need for each parameter you’re calibrating,
with color-coded fields that make it easy to see
where you enter data. The menu is simplified and
functions are laid out consistently so that once
                                                                USB ports are placed on the front and rear for downloading constants and remote
you learn how to operate one you know how to                    PC communication.
operate them all. Training new users just became
much easier.
Status indicators for OPERATE, STANDBY, and
HAZARDOUS VOLTAGE appear on the screen in
bright letters or icons you can recognize from
across the calibration lab.
The touch screen interface is available in nine
languages, including English, French, German,
Spanish, Japanese, Chinese, Portuguese, Russian
and Korean.
                                                                The graphical user interface lets you navigate easily with the touch of a finger.
11 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Automating calibration with MET/CAL software increases throughput and efficiency. Hundreds of procedures are available for the 5560A, 5550A and 5540A.
MET/CAL™ automation increases                                     You may purchase MET/CAL with MET/TEAM™,
                                                                  a dedicated asset management system. It is the
throughput and efficiency
                                                                  most complete software solution available for
Quality standards impose stringent requirements                   calibration professionals. However, if you already
for documenting, reporting, and controlling                       use a calibration asset management system, you
calibration processes and results. MET/CAL™                       can integrate MET/CAL into your workflow with
Calibration Management Software helps you                         MET/CONNECT™ Calibration Integration
meet these requirements while increasing                          Software. MET/CONNECT is the hub of a fast-
throughput and streamlining voltage calibration,                  growing community of mainline calibration
resistance calibration, and current calibration                   software providers that have partnered with
processes.                                                        Fluke Calibration to support MET/CAL automa-
                                                                  tion. Whatever calibration management system
MET/CAL™ is a powerful application for creating,                  you use, MET/CONNECT unlocks calibration and
editing and testing calibration procedures                        workflow automation in your lab.
and collecting and reporting results on a wide
variety of instruments. As the industry-leading
software for automated calibration, thousands                     Priority software support helps you stay
of calibration procedures have been written to                    productive
automate a vast array of calibrations around the                  MET/SUPPORT Gold is an annual membership
world.                                                            program offering premium support and services
                                                                  to help you stay as productive as possible with
The 5560A, 5550A and 5540A work with
                                                                  MET/CAL software. Services include free software
MET/CAL, including hundreds of automated
                                                                  updates and upgrades, free access to the Fluke
calibration procedures to consistently and
                                                                  MET/CAL Warranted Procedures Library, priority
dramatically improve throughput. MET/CAL v10.6
                                                                  technical support, plus discounts on training and
and later includes a Function Select Code (FSC)
                                                                  custom procedure development. Members also
that enables you to add the 5560A, 5550A and
                                                                  receive invitations to regular calibration software
5540A seamlessly to your existing calibration
                                                                  web seminars and user group meetings. Use
operations. MET/CAL VX.xx supports the
                                                                  only a few of the Gold services and you can easily
oscilloscope calibration options.
                                                                  recover more than the cost of your membership
                                                                  fee.
12 Fluke Corporation    5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Your choice of specifications
How often to calibrate? You decide.
The 5560A includes 90-day, 1-year, and 2-year specifications, while
the 5550A includes 90-day and 1-year specifications and the 5540A
includes 1-year specifications. You can manage the cost of owner-
ship and maximize uptime by keeping the calibrator in service as
long as possible based on your unique specification requirements.
That means you may not need to calibrate it every year.
Metrology training builds team skills
Calibration and metrology training from Fluke Calibration improves
the knowledge of you and your colleagues in a wide variety of
disciplines. Instructor-led classroom training is available for general
topics in metrology that include both hands-on training and training
in measurement uncertainty, as well as classes on how to use Fluke
Calibration software. On-site training is available for teams with
specific training needs. Instructor-led and self-paced online courses
are available as well.
Fluke Calibration also offers web seminars, events and road shows
on a wide variety of topics. To stay informed about these events,
register online and subscribe to our e-news.
Calibration and repair services keep you up and running
Fluke Calibration offers extensive calibration support and services
to ensure long-term customer satisfaction and return on invest-
ment. Our worldwide network of service centers offers accredited
calibration traceable to national standards. We provide fast, quality
repair services and full support in setting up your calibration lab.                     Calibration and metrology training includes a variety of
                                                                                         offerings including classroom, online, and on-site.
13 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Specifications
 Comparing the 5560A, 5550A, and 5540A
 Function                                                5560A                                5550A                              5540A
 Direct voltage                                                                         0 V to ± 1020 V
 Direct current                                                                         0 A to ± 30.2 A
                                                                                       1 mV to 1020 V
 Alternating voltage
                                                                                       3 Hz to 500 kHz
                                                                                       10 µA to 30.2 A
 Alternating current
                                                                                       3 Hz to 30 kHz
 Volt/hertz product                                                          1000 V at 10 kHz/330 V at 100 kHz
 Waveforms                                                                      Sine wave and square wave
 Resistance variable                                                                   0 Ω to 1200 MΩ
 Capacitance variable                                                                   0 nF to 120 mF
 Inductance variable                                                   12 µH to 120 H                                                 -
 Power (dual output – phantom loads)                                       30.9 kW                                                    -
 Oscilloscope bandwidth                      2.1 GHz, 1.1 GHz, or 600 MHz              1.1 GHz or 600 MHz                      600 MHz
 Phase lock                                                                                   Yes
 Phase control                                                              0.01°                                                     -
 Frequency uncertainty                                                                    <2.5 ppm
 Temperature standard                                                                  ITS-90, IPTS-68
                                            Cu 10 (427), Cu 100 (428), Cu 50 (428), Ni 120 (672), Pt 100 (385), Pt 100 (3916), Pt 100 (3926),
 Resistance temperature detectors
                                                                       Pt 1000 (385), Pt 200 (385), Pt 500 (385)
 (RTDs) output
                                                                          Compensation: off, 2-wire, 4-wire
 External frequency reference 10
                                                                                              Yes
 MHz
 Thermocouples (source and
                                                            A1 (BP,A), B, C, D, E, G, J, K, L, N, R, S, T, U, XK, 10 μV/°C, 1 mV/°C
 measure) External or internal CJR
 Interfaces / Remote commands                                           USB 2.0, Ethernet Telnet, RS-232 and GPIB
                                                                            Current capability up to 120 A
 52120A Amplifier current capability
                                                    Current capability up to 360 A with three 52120As (parallel) manual operation
14 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Ordering information
 Models                Description
 5560A                 5560A High-Performance Multi-Product Calibrator
                       5560A High-Performance Multi-Product Calibrator + 2.1 GHz Oscilloscope
 5560A/2G
                       Calibration Option
                       5560A High-Performance Multi-Product Calibrator + 1.1 GHz Oscilloscope
 5560A/1G
                       Calibration Option
                       5560A High-Performance Multi-Product Calibrator + 600 MHz Oscilloscope
 5560A/600M
                       Calibration Option
 5550A                 5550A Performance Multi-Product Calibrator
                       5550A Performance Multi-Product Calibrator + 1.1 GHz Oscilloscope Calibration
 5550A/1G
                       Option
                       5550A Performance Multi-Product Calibrator +600 MHz Oscilloscope Calibration
 5550A/600M
                       Option
 5540A                 5540A Multi-Product Calibrator
 5540A/600M            5540A Multi-Product Calibrator + 600 MHz Oscilloscope Calibration Option
                       All models include full Accredited 17025 Calibration Certificate traceable to
                       international standards with data.
 Optional
 accessories           Description
 55XXA/LEADS           Thermocouple and Test Lead Set with Case
 55XXA/COIL 10         1, 2 and 10-Turn Current Coil, Includes an Accredited 17025 Calibration Certificate
                       Traceable to International Standards with Data
 55XXA/COIL 50         50-Turn Current Coil, Includes an Accredited 17025 Calibration Certificate
                       Traceable to International Standards with Data
 55XXA/                DMM AUTOCAL Adapter
 DMMCAL
 55XXA/                5560A Portability Kit for On-Site Calibrations
 PORTKIT
 55XX/CASE             Extra case. 5560A, 5550A and 5540A include hard case
 Priority Gold         Premium Instrument Service Plan (where available)
 Instrument
 CarePlan
15 Fluke Corporation   5560A High-Performance Multi-Product Calibrator, 5550A Performance Multi-Product Calibrator and 5540A Multi-Product Calibrator
Ordering information
Software       Description
MET/CAL/
               Software, MET/CAL w/MET/TEAM
TEAM
MET/CAL-TL     License, Additional MET/CAL (TEAM)
MET/TEAM-L     License, Additional MET/TEAM
MET/CAL/
               Software, MET/CAL with MET/TEAM Express
TEAMXP
MET/TEAMXP-L   License, Additional MET/TEAM Express
MET/TEAM
               Module, MET/TEAM Mobile
Mobile
MET/TEAM
               License, Additional MET/TEAM Mobile
MOBILE-L
MET/TEAM
               Module, MET/TEAM Customer Portal
PORTAL
MET/TEAM
               License, additional MET/TEAM Customer Portal (pack of 100)
PORT-L100
MET/TEAM
               Module, MET/TEAM Commerce
COMMERCE
MET/
               MET/CAL w MET/CONNECT
CAL-METCON
MET/CAL-MCL    License, Additional MET/CAL (MET/CONNECT)
MET/CONNECT    Calibration Integration Software
                                                  Fluke Calibration. Precision, performance, confidence.™
                                                   Electrical   RF   Temperature   Humidity       Pressure        Flow       Software
                                                  www.flukecal.com            ©2022-2023 Fluke Calibration.
                                                                              Specifications subject to change without notice.
                                                                              Printed in U.S.A. 2230414-en
                                                                              Modification of this document is not
                                                                              permitted without written permission
                                                                              from Fluke Calibration.