English C Ensure the valve arrows face in the direction of

water flow, and push valve onto inlet and outlet


pipes until secure. Follow PVC cement instruc-

Rain+Birdt
tions for cure time.

CP/CPF Series Valve Installation


and Operation
1 2
SOLENOID

FLOW CONTROL
(select models) TO LANDSCAPE WATER SOURCE

BLEED
SCREW
Connect Valve Wires

bb
NOTE: Use watertight connectors and direct
OUTLET burial wire for all connections.

A Connect one solenoid wire to a common wire


(usually white). All valves can share the same
INLET common wire.

B Connect the second solenoid wire to a power


wire (usually colored).

BODY

Before Installation
llInstall master valves, pressure regulators and back-
flow preventers as needed.
llA pressure regulator is required if water pressure
1
exceeds 150 PSI (recommended over 80 PSI).
llInline valves require a separate backflow preventer
in the main line. Check local building codes. 2
llFlush the system thoroughly until water runs clear.

llShut off the main water supply.

Connect Valve to Pipes


A Apply PTFE thread-seal tape to the male threads
on the adapters, screw into the valve and
hand-tighten (do not use PVC glue or pipe dope
on adapter threads).

B Apply primer and then PVC cement to the ends


of the pipe and inside the adapters per manu-
facturer’s instructions.
1
Valve Operation Operating Ranges
075-CP / 075-CPF 100-CP / 100-CPF
Manual Operation:
Flow2 0.2 - 22 GPM 0.2 - 40 GPM
A Manual on: Turn the solenoid counter-clockwise Pressure 15 - 150 PSI 15 - 150 PSI
1/4 turn. Do not unscrew completely. To close,
hand tighten clockwise.
bb
NOTE: For flows below 3 GPM (0.75 m3/h), or
any drip application, use a 200 mesh filter up-
B Flow control (select models only): Turn clock-
stream and a pressure regulating filter down-
wise to restrict flow. Turn counter-clockwise to
stream from the valve. 40 psi for 1” and 30 psi for
open flow.
3/4” drip lines.
C Flush valve to clear debris: Turn the bleed screw
Troubleshooting
counter-clockwise ONLY 1 turn. Flush one min-
ute and turn clockwise to close. Symptom Solution
Valve Make sure flow control is open (select
First Use:
Won’t Turn models)
D Open the main water supply and flush one min- On when
Solenoid is
Check that main water supply is on
Make sure piping is connected properly and
ute with bleed screw to clear debris.
Turned not blocked
E Test wiring by using the Manual Water feature Verify timer settings are correct
on the irrigation controller. Check and repair wiring and connections as
Valve Won’t
needed
F Adjust the flow control to reduce over-spray. Turn On at
Check and replace valve solenoid as need-
(select models). the Timer
ed
Verify timer power output
Verify timer settings are correct
Valve Won’t
Hand tighten solenoid and bleed screw if
Shut-off
needed
Incorrect timer settings
2 Check wiring
Valve Won’t
Check solenoid
Turn On at
the Valve Timer not supplying power to the valve
1 Make sure the Flow Control stem is not
turned all the way closed
Clear debris by opening the bleed screw
Leaks at
and flushing 1 minute
sprinkler
Remove and clean the diaphragm. Replace
heads
3 if needed.
Check pipe fittings connection and glue,
repair or replace as needed
Hand tighten solenoid and bleed screw if
needed
Pressure Loss Chart Leaks around If vacuum breaker is leaking (anti-siphon
the valve models) remove cap, gasket, and internal
12
piston gasket to clean and reassemble
Pressure Loss - PSI

10 Turn off main water supply, relieve pressure


on the valve by opening the bleed screw
8
and tighten the jar top bonnet
6

bb
NOTE: During winter, shutdown and drain the
4
system to protect valves from freezing. Failure to
2 properly drain the lines can result in damage to
0 the valves, which is not covered under the cus-
0 10 20 30 40 50 tomer satisfaction policy.
3/4" CP-075 1" CP-100
Flow Rate - GPM
2
Rain+Birdt
Rain Bird Corporation
Consumer Products Division
6991 East Southpoint Rd. Bldg #1
Tucson, AZ 85756
Tel.: 1-800-RAINBIRD (800-724-6247)
www.rainbird.com

Questions?
In the USA or Canada, call Rain Bird
toll free Technical Support at
1-800-724-6247
or visit our valves support web site

Copyright 2016 Rain Bird Corporation


Registered trademark of Rain Bird Corporation
P/N: 182193 06AP16EO

You might also like