1 2 3 4 5 6 7
F ELECTRICAL NOTES: ABB REVIATIONS:
Ø PHASE M MOTOR W WATT / WIRE
GENERAL NOTES: MA MILLIAMP W/ WITH
1. THE FOLLOWING COMPONENT IDENTIFICATION SHALL BE USED AS A AMPERE(S) MB MAIN BREAKER WP WEATHERPROOF
APPROPRIATE: A/C AIR CONDITIONING MCB MAIN CIRCUIT BREAKER WTP WATER TREATMENT PLANT
1.1. (F) FIELD MOUNTED NOT AT STARTER OR OTHER CONTROL PANELS. Al ANALOG INPUT MCC MOTOR CONTROL CENTER WTP-AC- ACCESS CONTROL PANEL
1.2. (S) STARTER PANEL MOUNTED. ALT ALTERNATE MCP MAIN CONTROL PANEL WTP-PP- PATCH PANEUNETWORK PANEL
1.3. (TCP) AT TEMPERATURE CONTROL PANEL. AO ANALOG OUTPUT MH MAN HOLE
1.4. (MCP) AT MAIN CONTROL PANEL. ARV AIR RELEASE VALVE MIN MINIMUM XFMR TRANSFORMER
2. ELECTRICAL MATERIALS AND EQUIPMENT ITEMS SHOWN IN LIGHT LINE WEIGHTS ON THE DRAWINGS ARE FUTURE. ELECTRICAL MATERIALS AND EQUIPMENT ASB ALARM SILENCE BUTTON MLO MAIN LUG ONLY
ITEMS SHOWN IN HEAVY LINE WEIGHTS ARE NEW TO THIS CONTRACT UNLESS OTHERWISE NOTED. AWG AMERICAN WIRE GAUGE MM MULTI-MODE
3. FOR ITEMS INDICATED AS 'FIELD LOCATE' CHECK DRAWINGS OF OTHER TRADES (IN PARTICULAR PROCESS PIPING AND STRUCTURAL) FOR INTERFERENCES MP METERED PUMP
AND FOR LOCATIONS OF MOUNTING FLANGES, CONNECTION POINTS, ETC. BFV BUTTERFLY VALVE MS MOTOR STARTER
4. INSTALL A SINGLE CONDUCTOR INSULATED (RHW, THHN OR XHHW) COPPER GROUND WIRE IN EACH CONDUIT, SIZE AS SHOWN ON DRAWINGS OR AS A MTR MASTER
MINIMUM PER THE NATIONAL ELECTRICAL CODE. THIS GROUND WIRE SHALL BE CONNECTED AT EACH END TO THE EQUIPMENT GROUND. CONDUIT SHALL C CONDUIT BID SET
BE 3/4" MINIMUM. CAT CATEGORY N NEUTRAL
5. WIRE NUMBERS (1,3 & 5) ETC. SHALL BE PREFIXED WITH STARTER TAG NUMBERS. THE WIRE NUMBER AFTER THE PREFIX, MAY BE THE MANUFACTURERS CB CIRCUIT BREAKER NO. NUMBER
WIRE NUMBERING SYSTEM. WIRE MARKERS MAY BE USED AT EACH WIRE TERMINATION POINT. CLAR CLARIFIER
6. PROVIDE SIGNAGE/PLACARD/TAGS AS INDICATED ON THE DRAWINGS DETAILS. CMR CAMERA O.C. ON CENTER
7. OUTSIDE EQUIPMENT MUST BE RATED FOR -40 TO 150 DEG F. CP CONTROL PANEL OL OVERLOAD
E 8. CONDUIT FILL MUST MEET NFPA REQUIREMENTS. (WHERE NFPA IS SILENT CONDUIT FILL MUST NOT EXCEED 40%) CR CONTROL RELAY ORP OXIDATION REDUCTION POTENTIAL
8.1. INSTRUMENT SIGNAL CONDUIT: SHIELDED SIGNAL WIRES FOR 4-20 MA TYPE INSTRUMENTS OR THERMOCOUPLE WIRES ASSIGNED TO THE SAME CSF CARBONSTORAGE& FEED
CONTROL PANEL MAY BE RUN IN THE SAME CONDUIT. NO OTHER WIRES WILL BE PERMITTED IN AN INSTRUMENT SIGNAU2-WIRE CONDUIT. CT CURRENTTRANSFORMER P POLE
8.2. CONTROL CIRCUIT CONDUIT (120VAC). 120VAC CONTROL CIRCUIT WIRES USED FOR DISCRETE PLC INPUT OR MCC CONTROL ASSIGNED TO THE SAME P.B. PUSHBUTTON
CONTROL PANEUMCC MAY BE RUN IN THE SAME CONDUIT. NO OTHER WIRES WILL BE PERMITTED IN THE CONTROL CIRCUIT CONDUIT. DB DUCTBANK PDB POWER DISTRIBUTION BLOCK
8.3. CONTROL CIRCUIT CONDUIT (24VDC). 24VDC CONTROL CIRCUIT WIRES USED FOR DISCRETE PLC INPUT OR MCC CONTROL ASSIGNED TO THE SAME DI DISCRETE INPUT PDIT PRESSURE DIFFERENTIAL CURRENT TRANSMITTER
CONTROL PANEUMCC MAY BE RUN IN THE SAME CONDUIT. NO OTHER WIRES WILL BE PERMITTED IN THE CONTROL CIRCUIT CONDUIT. DO DISCRETE OUTPUT PEP PRE-ENGINEERED PANEL
8.4. COMMUNICATION CONDUIT (ETHERNET). COMMUNICATION WIRE USED FOR ETHERNET, FIBER OPTIC, OR MODBUS MAY BE RUN IN THE SAME CONDUIT. DWG DRAWING PLC PROGRAMMABLE LOGIC CONTROLLER
NO OTHER WIRES WILL BE PERMITTED IN THE COMMUNICATION CONDUIT (ETHERNET). PM PHASE MONITOR
8.5. COMMUNICATION CONDUIT (FIELD BUS). FIELD BUS WIRE USED FOR CONTROLNET OR DEVICENET MAY BE RUN IN THE SAME CONDUIT. NO OTHER EFF EFFLUENT PP-XX POWER PANEL
WIRES WILL BE PERMITTED IN THE COMMUNICATION CONDUIT (FIELD BUS). EM EMERGENCY PVC POLYVINYL CHLORIDE
9. EQUIPMENT SHOWN INSIDE SHALL BE RATED NEMA 12 AND EQUIPMENT SHOWN OUTSIDE SHALL BE RATED NEMA 4X, UNLESS OTHERWISE INDICATED. ENET ETHERNET
10. MINIMUM CONTROL WIRE SIZE SHALL BE EITHER #14 AWG OR 2/C#18SH AND MINIMUM POWER WIRE SIZE SHALL BE #12 AWG. ETI ELAPSED TIME INDICATOR RAD RADIANT
11. MINIMUM CONDUIT SIZE SHALL BE 3/4". RCP REMOTE CONTROL PANEL (R I/0)
12. PROVIDE INSULATED CONDUCTOR (RHW) FOR EXTERIOR WORK AND (THHN) FOR INTERIOR WORK FACP FIRE ALARM CONTROL PANEL RL RUNNING LIGHT
FB FUSE BLOCK / FEEDER BREAKER RPM ROTATIONS PER MINUTE
FIT FLOW INDICATING TRANSMITTER RTD RESISTANCE TEMPERATURE DETECTOR
FO FIBER OPTIC RW/RWI RAW WATER/RAW WATER INTAKE
FOC FIBER OPTIC CONVERTER RWP RAW WATER PUMP
FOPP FIBER OPTIC PATCH PANEL
D FVNR FULL VOLTAGE NON-REVERSING SCHED SCHEDULE
O FWP FINISHED WATER PUMP SEL SELECTOR
SH SHIELDED
G / GND GROUND SKD SKID
GA GAUGE SS STAINLESS STEEL
GAL GALLON(S) SPD SURGE PROTECTIVE DEVICE
GALV GALVANIZED STA STATION
N
GEN GENERATOR
<
O GFCl/GFI GROUND FAULT CIRCUIT INTERRUPTER T THERMOSTAT
TB-X TIE BREAKER
HOA HAND-OFF-AUTO TNK TANK
O HORIZ HORIZONTAL TRN TRAIN
HP HORSEPOWER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION
Z HSP HIGH SERVICE PUMP (FINISHED WATER) TYP. TYPICAL
O HTR HEATER
HTS-X HEAT TRACE SYSTEM UPS UNINTERRUPTIBLE POWER SUPPLY
HZ HERTZ
V VOLTAGE
I/O INPUT/OUTPUT VA VOLT AMPS
INC IN-USE COVER VAC VOLTAGE ALTERNATING CURRENT
C IWH EYE WASH HEATER VDC VOLTAGE DIRECT CURRENT
VDS VIDEO DISPLAY STATION
KVA KILO-VOLT-AMPS VERT VERTICLE
Z
O VFD VARIABLE FREQUENCY DRIVE O
Z
LC-X LIGHTING CONTROL PANEL
<
O
LP-XX LOW VOLTAGE 120/208V PANEL
LCP LOCAL CONTROL PANEL (1/0)
O
O
O
O
- <
<
Z
<
Z
Z
B æ Z
!ß 5 F- O
E s O F-
LL Z <
O
co
O
O -
O
O
O
Z
O
O o
e
Project No.: 200-11740-10003
Designed By: TAC
Drawn By: TAC 8
Checked By: DAB
O ..
O
E-0002
Bar Measures 1 inch