DIESEL GENSET MODEL
SGP 2000 PH
Rating
2000 kVA
1600 kW
Voltage
Frequency
Speed
415 Volts
50 Hz
1500 RPM
Optional equipment and finishing shown. Standard may vary.
PRODUCT HIGHLIGHTS
Engine
CPCB II compliant
Fast load response
Stable frequency
Low vibrations and structure borne noise level
Competitive fuel and lube oil consumption
High power to weight ratio
Proven low life cycle cost
Alternator
Brushless type, screen protected, self-excited
alternator complying to IS 4722/IEC 60034 1
Excellent motor start capability
Excellent alternator efficiency across the
load range
Compact design with sealed bearings for longer
life and lower maintenance
Optimised engine compatibility
D. G. Package
Highly optimised and efficient package design
Excellent
performance
under
most
demanding environmental conditions
Near zero down time for continuous power supply
Sturdy base frame made from folded sheet
metal for increased strength
Efficient anti-vibration mounts
Stringent shop floor testing to ensure class
leading, hassle-free performance
Testing carried out using state-of-the-art
PLC based, resistive load bank
Product Support
Seamless 24 x 7Service support with toll
free number 1800 3000 7666
Best in class product support with PAN India Presence
Highly
Energetic
team
with
immense
experience in troubleshooting.
APPLICATION DATA
Engine
Engine Make & Model
Base Frame
Frequency
Engine Speed
Fuel Tank Capacity
Rated Current
Alternator
Perkins-4016-61TRG2 Make
Frame
Power Factor
SGPL No. of Phase
50 Hz Frequency
1500 RPM Rated Voltage
990 Liters Voltage Regulation
2572Amps Excitation System
Leroy Somer
LSC74L
0.8
3
50 HZ
415V 5%
1%
Self-Excited Self-Regulated
Brushless
R 450
AVR Type
No. of Cylinders
16
Type of Construction
Displacement
Bore / Stroke
Gross Engine Power Output
Rated Speed
Aspiration
Governor Type & Class
Vee
Medium Duty
Axial Flow
12-37 mbar
61.12 L Air Filter Type
160X190 mm Air Intake Restriction
2379 BHP
1500 RPM
Turbocharged
Lubrication System
Electronic Recommended Lube Oil
Lube Oil Consumption
Cooling System
Method of Cooling
Qty of Coolant (Engine)
Induction System
API-CG15W/40
0.1% Of SFC
Lube Oil Filter Type
Heat Exchanger Lube Oil System Capacity (With Filter) :
225 L
Paper element
213 L
Exhaust System
Fuel System
Silencer Type
Number of Silencers
Maximum Allowable Back Pressure
Direct injection Exhaust Gas Temperature
HSD
Spin On Paper Element
Make/Type of Injection System
Recommended Fuel
Fuel Filter Type
Specific Fuel Consumption : L/hr
75% Load
100% Load
278.67
376.09
*Note: Specific gravity of fuel considered - 850
gms/Litre with +3% tolerance
Resdential
2 No.
40 mbar
457 Deg C
Diesel Genset ModelSGP 2000 PH| 2
Dimensions & Weights
Drawing above for reference purpose only. Dimensions may vary with other voltages. Not to be used for installation purpose.
Length = L
mm
5847 Wet Weight (Approx.) kg
Width = w
mm
1932
Height = H
mm
2631
Output Ratings
Generating Set Rating @ 415V - 50 Hz | 2000 KVA | 1600 kW
Note: Ratings at 0.8 power factor.
Definitions: Prime Rating
This rating is applicable for supplying continuous electrical power (at variable load) in lieu of
commercially purchased power for unlimited number of hours with an average load factor of 80%
Fuel Consumption Data:
Fuel consumption data with diesel fuel of specific gravity 0.85 and conforming to IS: 1460
Standard Features
Perkins Range
Sterling provides a range of Perkins engine powered generating sets which are recognised for reliability.
Global technology available in India.
Most energy efficient D. G. set in its own rating.
Microprocessor based control panels.
Wider maintenance intervals.
Pre tested at factory with PLC test bench.
Well experienced and trained engineers for 24 x 7 after sales support.
Designed to meet the latest environmental norms and approved by CPCB nodal agency.
3 |Diesel Genset ModelSGP 2000 PH
*****
Standard Control Panel
SG 2010:
Standard Supply
Operating Features
Microprocessor based digital controller
Accurate LCD display
Local Start/Stop
Auto Main Fail Detection & Mains Monitoring
Remote Start/Stop
Generator breaker control
Easily Accessible through Fascia
Engine Protection/Faults Moni through CAN
Flexibility for Selecting Manual, AMF Operations
Metering
Engine Parameters:
Engine Speed
Lube Oil pressure
Coolant temperature
Engine Running Hour
Engine Battery voltage
Running status
Fuel level in Percentage
Event Log with date and time
Electrical Parameter Generator
Generator Voltage (Ph-Ph)
Generator Voltage (Ph-N)
Current -(R,Y,B) Generator
apparent power (kVA)
Generator active power(kW)
Generator reactive power(kVAr)
Generator Power Factor
Generator Frequency (Hz)
Cumulative Power Consumption in kWh
Cumulative Power Consumption in kVAh
Cumulative Power Consumption in kVArh
Mains Voltage (Ph-Ph)
Monitoring
Generator Breaker Status
Generator Healthy Status
Mains Healthy Status
Mains Breaker Status
Engine
High Water Temperature
Low Coolant Level
Engine Overspeed
Low oil pressure
Low Fuel Level
Electrical
Generator under Voltage (ANSI-27)
Generator over Voltage (ANSI-59)
Generator under Frequency (ANSI-81L)
Generator over Frequency (ANSI-81H)
Generator Over Current (ANSI-51)
Generator kW Overload (ANSI-32P)
Control Supply under Voltage
Control Supply over Voltage
Breaker/Contactor
DG Breaker
Mains Breaker
Communication
RS485-Modbus Communication Available for BMS/PLC
Panel location
Right side of the canopy viewing from Alternator end.
General Information
Documentation
A full set of operation and maintenance manuals and circuit wiring diagrams.
Warranty
Please refer warranty policy.
No
No