ESP32 LoRa bridge that reads a P1 (DSMR) smart electricity meter over a DX-LR22 modem and publishes it to Home Assistant via MQTT

Topics

Resources

Stars

12 stars

Watchers

1 watching

Forks

Latest commit

 

History

12 Commits

Folders and files

Repository files navigation

Zat

A two-board LoRa bridge for a P1 (DSMR) smart electricity meter. One ESP32 sits at the meter, reads the P1 port and sends every valid reading over a DX-LR22 LoRa modem. A second ESP32 near your WiFi receives the readings and publishes them to MQTT with Home Assistant discovery.

It is meant for homes where the meter is out of WiFi range (a basement, a meter cabinet, another building). The transmitter keeps WiFi and Bluetooth off.

The Home Assistant entities keep the names used by an earlier ESPHome version of this project (device "Electricity meter", so sensor.electricity_meter_power, sensor.electricity_meter_energy_total, …). Dashboards and automations built for that version keep working once the old ESPHome device is removed from Home Assistant. The new entities have new unique IDs, so while the old ones are still registered, Home Assistant names the new ones sensor.electricity_meter_power_2 and so on.

Contents

Features

  • Reads the P1 port directly. The ESP32 inverts the UART itself on GPIO16, so you don't need a transistor or an inverter chip. Two resistors and an RJ12 cable are all the extra hardware it needs.
  • Checks the telegram CRC. Each telegram's CRC16 is checked, and a reading is used only if it matches. Dropped telegrams (bad CRC or cut off) are counted and reported to Home Assistant as P1 CRC errors.
  • No float rounding. Values are parsed and sent as fixed-point integers (Wh, W, 0.1 V, 0.01 A), so kWh totals keep all three decimals.
  • Compact radio packets. Each reading is 59 bytes with a CRC-8, a sequence number and a network ID, so several transmitter/receiver pairs can share a channel.
  • Sets up the modem by itself. At every boot, each ESP32 puts its DX-LR22 into AT mode, reads every setting and changes only the ones that differ from config.h.
  • Home Assistant MQTT discovery. 22 sensors plus a LoRa link connectivity sensor, with retained states. Discovery is sent again when Home Assistant restarts.
  • Availability tracking:
    • Meter entities become unavailable when no meter data arrives for 20 s.
    • The LoRa link sensor turns off after 75 s without any packet.
    • An MQTT Last Will marks the whole bridge offline if the receiver disconnects.
  • Heartbeat while the meter is silent. The transmitter sends a small status packet every 60 s, so you can tell "meter silent" apart from "radio link down".
  • Test mode. The transmitter can send changing mock readings, so you can test the radio link and Home Assistant without a meter.
  • OTA updates. The receiver supports Arduino OTA, with an optional password.

How it works

flowchart LR
    M[Smart meter<br/>P1 port] -- "DSMR telegrams<br/>115200 8N1, inverted" --> TX[ESP32 transmitter<br/>P1LoRaTransmitter]
    TX -- UART 9600 --> L1[DX-LR22]
    L1 -. "LoRa, 59-byte packet<br/>at most every 5 s" .-> L2[DX-LR22]
    L2 -- "UART 9600<br/>+ RSSI byte" --> RX[ESP32 receiver<br/>P1LoRaReceiver]
    RX -- "WiFi / MQTT<br/>HA discovery" --> HA[MQTT broker<br/>Home Assistant]
Loading
  1. Transmitter (P1LoRaTransmitter): reads DSMR telegrams from the meter and drops any with a bad CRC. Every 5 s (TX_PERIOD_MS) it sends the newest valid reading, but only when a new telegram has arrived since the last packet.
    • Readings older than 30 s (P1_STALE_MS) are not sent.
    • While no fresh data exists, it sends a status packet (no meter values) every 60 s (STATUS_PERIOD_MS).
  2. Receiver (P1LoRaReceiver): drops packets that are malformed or carry another network ID. It publishes each value to MQTT and adds two computed values, Energy Total and Export Total (T1 + T2 + T3). It also reports the LoRa RSSI of each packet and the transmitter's P1 CRC error count. Readings that arrive while the receiver is disconnected from MQTT are logged to serial but not buffered or published.

Hardware

Part Qty Notes
ESP32-WROOM DevKit 2 One at the meter, one within WiFi range. Pin numbers in config.h assume a DevKit.
DX-SMART DX-LR22-900T22D 2 UART LoRa modem (LLCC68). The driver follows the module's "serial port application guide" v2.2.
RJ12 cable (6P6C) 1 From the meter's P1 port to the transmitter ESP32. Use a 6-wire cable: the transmitter takes its power from pins 1 and 6.
Resistor, 1 kΩ 1 Between P1 pin 1 (+5V) and pin 2 (Data Request), so the meter sends telegrams.
Resistor, 1 kΩ 1 Pull-up between GPIO16 (RX2, P1 Data) and 3.3V on the transmitter ESP32.
Smart meter with a P1 port 1 The parser targets the IEC Kaifa three-phase meter (see below).

The transmitter is meant to be powered from the meter's P1 port (see the comment at the top of P1LoRaTransmitter.ino). Check that your meter's P1 port can supply the ESP32 plus the LR22 at your transmit power. The receiver needs a 2.4 GHz WiFi network.

Meter compatibility. The parser reads these OBIS codes:

OBIS Value
1-0:1.8.11 / 1.8.12 / 1.8.13 Energy imported, tariffs T1–T3 (kWh)
1-0:2.8.11 / 2.8.12 / 2.8.13 Energy exported, tariffs T1–T3 (kWh)
0-0:96.14.1 Active tariff
1-0:1.7.0 / 1-0:2.7.0 Power imported / exported (kW)
1-0:21.7.0 / 41.7.0 / 61.7.0 Power L1 / L2 / L3 (kW)
1-0:32.7.0 / 52.7.0 / 72.7.0 Voltage L1 / L2 / L3 (V)
1-0:31.7.0 / 51.7.0 / 71.7.0 Current L1 / L2 / L3 (A)

Meters that use other codes (for example the Dutch 1-0:1.8.1 / 1.8.2 tariffs) won't fill the energy fields unless you change P1_FIELDS in p1_packet.cpp on both sides.

Wiring

Both boards wire the LR22 the same way:

LR22 pin ESP32 pin config.h
TXD GPIO26 (ESP32 RX) PIN_LR22_RX
RXD GPIO27 (ESP32 TX) PIN_LR22_TX
AUX GPIO25 PIN_LR22_AUX
M0, M1 not connected AT+SWITCH0 makes them module outputs
VCC ESP32 VIN (5V) The module board is marked 3.3–5.5 V.
GND ESP32 GND

The transmitter also connects to the meter's P1 port with an RJ12 (6P6C) cable. In this build the ESP32 sits on a screw-terminal breakout board, and the LR22 power wires share the VIN and GND terminals with the P1 power:

P1 to ESP32 wiring: RJ12 pins, the two 1 kΩ resistors and the LR22 power

P1 pin (RJ12) Signal Connect to
1 +5V ESP32 5V (VIN), and through a 1 kΩ resistor to pin 2
2 Data Request Through a 1 kΩ resistor to pin 1 (+5V); this enables the P1 output
3 Data GND ESP32 GND
4 not used —
5 Data GPIO16 (RX2, PIN_P1_RX), with a 1 kΩ pull-up resistor to 3.3V
6 Power GND ESP32 GND

The pull-up is needed because P1 Data is an open-collector output. Pulling it up to 3.3V, not 5V, keeps the signal safe for the ESP32 input. The signal is still inverted in software, so no transistor or inverter is needed. The pin numbers follow the DSMR P1 standard; check your meter's documentation if it differs.

The transmitter build

Inside the enclosure Installed at the meter
Transmitter enclosure open: ESP32 on a screw-terminal board in the lid, DX-LR22 module in the box, RJ12 cable entering from the side Transmitter enclosure mounted next to the Kaifa meter, with the RJ12 cable plugged into the meter's P1 port and the LoRa antenna on top

Installation

The firmware is two Arduino sketches. There is no PlatformIO project and no prebuilt binary.

Requirements

  • Arduino IDE or arduino-cli with the ESP32 Arduino core (Espressif). The code is kept C++11-compatible so it also builds on core 2.x.
  • The PubSubClient library (by Nick O'Leary), for the receiver only. WiFi and ArduinoOTA come with the ESP32 core.
  • An MQTT broker, such as the Mosquitto add-on in Home Assistant, with the MQTT integration enabled.

1. Configure

  1. Pick a NETWORK_ID, LoRa channel and air rate, and set them the same in P1LoRaTransmitter/config.h and P1LoRaReceiver/config.h. Each sketch has its own copy of config.h. See Configuration.
  2. Fill in P1LoRaReceiver/secrets.h (WiFi, MQTT, OTA). Don't commit it with real values; see Security notes.

2. Flash the transmitter

Arduino IDE: open P1LoRaTransmitter/P1LoRaTransmitter.ino, select ESP32 Dev Module, and upload.

arduino-cli compile --fqbn esp32:esp32:esp32 P1LoRaTransmitter
arduino-cli upload  --fqbn esp32:esp32:esp32 -p /dev/ttyUSB0 P1LoRaTransmitter

To test the link before you go to the meter, set TEST_MODE to 1 in P1LoRaTransmitter/config.h. The transmitter then ignores the P1 port and sends mock readings every 5 s. Set it back to 0 before you connect the real meter.

3. Flash the receiver

arduino-cli lib install PubSubClient
arduino-cli compile --fqbn esp32:esp32:esp32 P1LoRaReceiver
arduino-cli upload  --fqbn esp32:esp32:esp32 -p /dev/ttyUSB0 P1LoRaReceiver

Later updates can be sent over WiFi with Arduino OTA, using OTA_HOSTNAME and OTA_PASSWORD.

4. Check the serial logs

Both boards log at 115200 baud (LOG_BAUD). On a working setup you will see lines like:

# transmitter
LR22 ready (0 setting(s) changed)
P1 ok #12 fields=0x3FFFF P=1234W T1=12345678Wh
TX seq=13 data

# receiver
WiFi connected, IP ...
MQTT connecting... ok
MQTT discovery published
RX seq=13 fields=0x3FFFF RSSI=-62 received=13 lost=0

Configuration

All settings are compile-time #defines. Five of them can also be overridden with a build flag instead of editing config.h: LR22_LEVEL, LR22_CHANNEL, LR22_POWER_DBM, NETWORK_ID and TEST_MODE (transmitter only), for example -DNETWORK_ID=0xA102. The LR22_* values are C strings ("3"), so a flag must keep the quotes, e.g. -DLR22_LEVEL=\"2\". Each sketch is built separately, so pass the same pairing flags to both builds. All other settings (pins, timing, MQTT, secrets.h) must be changed in the files.

Radio and pairing (config.h, both sketches)

Define Transmitter default Receiver default Description
LR22_LEVEL "3" "3" Air-rate level 0–7 (table below). Must match on both sides.
LR22_CHANNEL "41" "41" Channel as two hex digits: 850.15 MHz + channel × 1 MHz. 41 (hex) = 915.15 MHz, the module default. Must match. Use a frequency your local regulations allow.
LR22_POWER_DBM "20" "10" Transmit power, 0–22 dBm. It can differ per side; the receiver sends nothing.
NETWORK_ID 0xA101 0xA101 16-bit pair ID. Packets with another ID are ignored. Must match.
TEST_MODE 0 — Transmitter only. 1 sends mock readings instead of reading P1.

Air-rate levels, from the DX-LR22 application guide (5.3.2):

Level Modulation Rate Level Modulation Rate
0 SF11 / 125 kHz 336 bps 4 SF8 / 500 kHz 10417 bps
1 SF11 / 250 kHz 1075 bps 5 SF7 / 500 kHz 18229 bps
2 SF11 / 500 kHz 2148 bps 6 SF6 / 500 kHz 37500 bps
3 SF8 / 250 kHz 6250 bps 7 SF5 / 500 kHz 62500 bps

At level 3 a 59-byte reading takes about 0.1 s on air. Lower levels reach further but take longer per packet.

Each board also applies these fixed LR22 settings at boot (lr22_esp32.h): MODE0 (transparent), SLEEP2 (always receiving), SWITCH0 (M0/M1 ignored), PACKET3 (230-byte sub-packets, so one reading is one LoRa packet), CRC1, IQ1. DRSSI is 1 on the receiver (the module adds an RSSI byte after each packet) and 0 on the transmitter.

Pins and serial ports (config.h)

Define Default Description
PIN_LR22_RX 26 ESP32 RX, from LR22 TXD
PIN_LR22_TX 27 ESP32 TX, to LR22 RXD
PIN_LR22_AUX 25 LR22 AUX (high while the module is busy)
LR22_BAUD 9600 LR22 UART speed (module default; not changed)
PIN_P1_RX 16 P1 Data input (transmitter)
P1_BAUD 115200 P1 UART speed (8N1, inverted)
LOG_BAUD 115200 USB serial log speed

Timing (config.h)

Define Default Used by Description
TX_PERIOD_MS 5000 transmitter Minimum time between packets
P1_STALE_MS 30000 transmitter Readings older than this are not sent
STATUS_PERIOD_MS 60000 transmitter Status packet interval while P1 is silent
METER_TIMEOUT_MS 20000 receiver Meter entities unavailable after this without data
LINK_TIMEOUT_MS 75000 receiver LoRa link turns off after this without any packet

Keep LINK_TIMEOUT_MS longer than STATUS_PERIOD_MS, or the link sensor will drop between status packets while the meter is silent.

MQTT and Home Assistant (config.h, receiver)

Define Default Description
MQTT_BASE_TOPIC "p1lora" Topic prefix; topics are p1lora/<network id>/...
HA_DISCOVERY_PREFIX "homeassistant" Home Assistant discovery prefix
HA_DEVICE_NAME "Electricity meter" Device name; entity IDs become sensor.electricity_meter_*

Credentials (secrets.h, receiver)

Define Default Description
WIFI_SSID "" WiFi network (2.4 GHz)
WIFI_PASSWORD "" WiFi password
MQTT_HOST "" Broker host name or IP
MQTT_PORT 1883 Broker port (plain TCP; TLS is not supported)
MQTT_USER "" Broker user name; set it to nullptr if the broker allows anonymous clients
MQTT_PASS "" Broker password
OTA_HOSTNAME "" Hostname for WiFi and Arduino OTA. Set a value, e.g. p1lora-receiver.
OTA_PASSWORD "" OTA password; "" means no password

Home Assistant and MQTT

Topics

With the defaults (NETWORK_ID 0xA101) the base topic is p1lora/a101, and the MQTT client ID and discovery node ID are p1lora_a101. All states are published retained, so Home Assistant gets the last values after a restart.

Topic Payload Meaning
p1lora/a101/bridge online / offline Receiver connected to MQTT (offline is the Last Will)
p1lora/a101/meter online / offline Meter data received in the last METER_TIMEOUT_MS
p1lora/a101/link ON / OFF Any packet received in the last LINK_TIMEOUT_MS
p1lora/a101/<key> number One topic per entity below

Discovery configs go to homeassistant/sensor/p1lora_a101/<key>/config and homeassistant/binary_sensor/p1lora_a101/link/config. The receiver subscribes to homeassistant/status and publishes discovery again when Home Assistant reports online.

Entities

Key Name Unit Device class State class
energy_t1, energy_t2, energy_t3 Energy T1–T3 kWh energy total_increasing
export_t1, export_t2, export_t3 Export T1–T3 kWh energy total_increasing
energy_total Energy Total (sum of T1–T3) kWh energy total_increasing
export_total Export Total (sum of T1–T3) kWh energy total_increasing
power Power kW power measurement
power_export Power Export kW power measurement
power_l1, power_l2, power_l3 Power L1–L3 kW power measurement
voltage_l1, voltage_l2, voltage_l3 Voltage L1–L3 V voltage measurement
current_l1, current_l2, current_l3 Current L1–L3 A current measurement
tariff Active Tariff — — —
rssi LoRa RSSI (diagnostic) dBm signal_strength measurement
p1_crc_errors P1 CRC errors (diagnostic) — — total_increasing
link LoRa link (diagnostic, binary sensor) — connectivity —

The meter entities are available only while both bridge and meter are online. Diagnostic entities depend only on bridge, so you can still see the RSSI and link state when the meter is silent. Energy Total and Export Total are only published when all three tariff values are present.

For the Home Assistant Energy dashboard, use Energy Total as grid consumption and Export Total as return to grid. You can also add the per-tariff sensors separately.

Dashboard

The homeassistant/ folder holds a ready-made dashboard and the helper sensors it needs. They come from mp3llll/iec-p1-esphome-3phase (MIT) and use the same entity IDs (sensor.electricity_meter_*) as this receiver. The card text is in Hebrew and laid out right to left.

Home Assistant electricity dashboard

File What it is
homeassistant/configuration.yaml Helper sensors: daily and monthly utility_meter, baseload, peak today, comparison with yesterday, cost and month forecast
homeassistant/dashboard-views.yaml The full dashboard. Paste it into the Raw configuration editor
homeassistant/dashboard.yaml The same dashboard as a single card, to paste into a Manual card on an existing dashboard

Click a tile on the dashboard to open its history. Examples:

Power history, 5-minute aggregated Electricity Peak Today history
Electricity Cost Today history Power split between the three phases
Power L1 history Power L2 history
Power L3 history Power history

Requirements. The dashboard uses three custom cards that are not part of Home Assistant. Install them from HACS: Mushroom, ApexCharts Card and card-mod (it provides custom:mod-card). Reload the browser after installing. Without them the dashboard shows "Configuration error" or "Custom element doesn't exist".

Install

  1. Merge homeassistant/configuration.yaml into your own configuration.yaml. It adds utility_meter:, sensor: and template: sections. If you already have one of these keys, add the entries to it instead of repeating the key. Run Developer tools, YAML, Check configuration, then restart Home Assistant.
  2. Settings, Dashboards, Add dashboard, then open it.
  3. Click the pencil icon, then the three-dot menu, then Raw configuration editor. Replace everything with the contents of homeassistant/dashboard-views.yaml and save.

Adjust before relying on the numbers

  • Price. The Electricity Price sensor uses price_with_vat = 0.6352 ILS/kWh and a 0% discount, and Electricity Forecast Month uses fixed_charge = 0. Change them to match your tariff and bill.
  • Gauge limit. The load gauge uses max: 17 (3x25 A). Set it to 27 for 3x40 A.

Radio packet format

Defined in p1_packet.h; little-endian, 59 bytes:

Bytes Content
0 Magic 0xE1
1 Format version (1)
2–3 Network ID
4–5 Sequence number
6–8 Present mask (bit i = field i was in the telegram); 0 = status packet
9–10 P1 telegrams dropped (bad CRC or cut off) since the transmitter started; 16-bit, wraps
11–34 Energy imported T1–T3 and exported T1–T3, 6 × uint32 Wh
35 Active tariff
36–45 Power import, export, L1, L2, L3, 5 × uint16 W
46–51 Voltage L1–L3, 3 × uint16 in 0.1 V
52–57 Current L1–L3, 3 × uint16 in 0.01 A
58 CRC-8 (poly 0x07) over bytes 0–57

Values too large for their field are clamped. Power fields are 16-bit, so anything over 65.535 kW is sent as 65535 W.

The receiver counts gaps in the sequence numbers as lost packets and shows the count in its serial log. A jump of 1000 or more is treated as a transmitter restart.

Security notes

  • Keep credentials out of git. P1LoRaReceiver/secrets.h is tracked with empty values. Once you fill it in, git add -A or git commit -a will pick it up. To stop tracking local changes, run git update-index --skip-worktree P1LoRaReceiver/secrets.h.
  • The radio link has no encryption or authentication. Packets have a CRC-8 and a network ID, but no encryption or signature. Anyone in range can read your meter values, or send packets with your network ID that the receiver will accept. Treat the values as informational, not as a control or billing source.
  • MQTT is plain TCP. There is no TLS support. Keep the broker on your LAN and use a dedicated MQTT user.
  • Set an OTA password. With an empty OTA_PASSWORD, anyone on the LAN can flash new firmware to the receiver.

Troubleshooting

Log message Likely cause
LR22: no answer to +++ (check wiring, 9600 baud) TXD/RXD swapped, wrong RX/TX pins, or the module isn't powered. The board keeps running with the module's current settings.
LR22: <NAME> not supported here, skipped The module firmware doesn't know that AT command. Harmless if the remaining settings match the other side.
TX seq=… FAILED: LR22 busy AUX stayed high for 500 ms. Check the AUX wiring.
P1 telegram dropped: bad CRC Noise or a loose P1 cable. The count also shows in Home Assistant as P1 CRC errors.
TX seq=… status (no P1 data) The transmitter gets no valid telegrams. Check the P1 Data wiring (GPIO16) and its pull-up to 3.3V, the resistor between P1 pins 1 and 2 (Data Request), the ground, and that the meter's P1 port is enabled.
RX from another network (0x…), ignored Another pair is using the same channel. Use different NETWORK_ID values.
RX … bytes, no valid packet Bytes arrived but held no valid packet: another LoRa device on the same channel and air rate, or the two sketches have different copies of p1_packet.*.
No RX lines at all on the receiver The two sides have a different LR22_LEVEL or LR22_CHANNEL (the modules can't hear each other), or the transmitter isn't sending.
MQTT connecting... failed, state <n> Wrong MQTT_HOST, port or credentials. <n> is the PubSubClient state code (e.g. 5 = not authorized).
Meter entities unavailable, LoRa link on Status packets arrive but no meter data. See "status (no P1 data)" above.
All energy sensors stay empty Your meter uses different OBIS codes. See Hardware.

Project layout

P1LoRaTransmitter/
  P1LoRaTransmitter.ino   P1 reading, packet timing, test mode
  p1_telegram.{h,cpp}     DSMR telegram parser + CRC16 (no Arduino dependency)
P1LoRaReceiver/
  P1LoRaReceiver.ino      packet handling, MQTT, HA discovery, OTA
  secrets.h               WiFi / MQTT / OTA credentials
homeassistant/
  configuration.yaml      helper sensors for the dashboard
  dashboard-views.yaml    full dashboard (raw configuration editor)
  dashboard.yaml          same dashboard as a single card
assets/screenshots/       README screenshots
Both sketches (a copy in each folder):
  config.h                radio, pins, timing, topics
  lr22.{h,cpp}            DX-LR22 driver: AT configuration, send, frame receive
  lr22_esp32.h            LR22Port on ESP32 HardwareSerial + common LR22 settings
  p1_packet.{h,cpp}       59-byte radio packet encode/decode + CRC-8

Arduino builds every file in the sketch folder, so the shared files are copied into both. If you change lr22.*, lr22_esp32.h, p1_packet.* or the shared part of config.h, change both copies. The parser, packet and LR22 driver code doesn't depend on Arduino (the driver goes through the LR22Port interface), so it can be compiled and tested on a PC.

Contributing

Issues and pull requests are welcome. Please describe your meter model and include the serial log from both boards when reporting a problem. Keep the shared files identical in both sketch folders.

License

Licensed under the Apache License 2.0.

About

ESP32 LoRa bridge that reads a P1 (DSMR) smart electricity meter over a DX-LR22 modem and publishes it to Home Assistant via MQTT

Topics

Resources

Stars

12 stars

Watchers

1 watching

Forks

Releases

Packages

Contributors

Languages