Use nf-core/ribomsqc to:
- Perform automated quality control of ribonucleoside analysis by mass spectrometry.
- Summarize and visualize QC metrics through integrated MultiQC reports.
Figure 1: General workflow overview showing the pipeline steps from RAW file input through ThermoRawFileParser conversion, MSNBase XIC extraction, JSON merging, to final MultiQC report generation.
Figure 2: Detailed workflow diagram illustrating the data flow and process connections in the ribomsqc pipeline.
Note
If you are new to Nextflow and nf-core, please refer to this page on how to set-up Nextflow.
-
Prepare a samplesheet with your input data, for example:
id,raw_file Day_5,path/to/Day_5.raw
For more information, see the usage docs on required samplesheet.csv columns.
- Prepare an analytes TSV file (e.g.
qcn1.tsv) with your compounds and theoretical retention times. The TSV must have exactly these columns and format:
short_name long_name mz_M0 mz_M1 mz_M2 ms2_mz rt_teoretical
C Cytidine 50 μg/mL 244.0928 112.0505 555
U Uridine 25 μg/mL 245.0768 113.0346 1566
m3C 3-Methylcytidine methosulfate 100 μg/mL 258.1084 126.0662 508
m5C 5-Methylcytidine 100 μg/mL 258.1084 126.0662 655
Cm 2-O-Methylcytidine 20 μg/mL 258.1084 112.0505 883
m5U 5-Methyluridine 50 μg/mL 259.0925 127.0502 1866
I Inosine 25 μg/mL 269.088 137.0458 1741
m1A 1-Methyladenosine 25 μg/mL 282.1197 150.0774 523
G Guanosine 25 μg/mL 284.0989 152.0567 1726
m7G 7-Methylguanosine 25 μg/mL 298.1146 166.0723 554Note
If you are new to Nextflow and nf-core, please refer to this page on how to set-up Nextflow. Make sure to test your setup with -profile test before running the workflow on actual data.
Note
Replace only the values in the rt_teoretical column with your own retention times (in seconds) for each compound.
-
Run the pipeline:
nextflow run nf-core/ribomsqc \ --input samplesheet.csv \ --analytes_tsv qcn1.tsv \ --analyte all \ --rt_tolerance 120 \ --mz_tolerance 7 \ --ms_level 1 \ --outdir results \ -profile singularity
Warning
Please provide pipeline parameters via the CLI or Nextflow -params-file option. Custom config files including those provided by the -c Nextflow option can be used to provide any configuration except for parameters; see docs.
For more information, see the usage docs and parameters.
See results page for example output and output docs.
nf-core/ribomsqc was originally written by Roger Olivella.
If you would like to contribute to this pipeline, please see the contributing guidelines.
For further information or help, don't hesitate to get in touch on the Slack #ribomsqc channel (you can join with this invite).
See CITATIONS.md for tool references.
Ewels PA et al. (2020) The nf-core framework. Nat Biotechnol. doi:10.1038/s41587-020-0439-x