OOS: an open operating system for the Rigol DHO800/DHO900

OOS replaces the software of a Rigol DHO800/DHO900 oscilloscope with a Linux 6.12 kernel and a new scope application written in Rust. It runs from the scope's own SD card, next to the stock system, and you can switch back at any time.

Experimental software. Read the disclaimer before you install it. OOS has run on a DHO924S and, by a user report, on a DHO804; several functions have never run on real hardware (status). Measurements made with OOS are not calibrated to any standard.

Two channels: a 10:1 probe on the calibration signal and the built-in generator A square wave with its spectrum and peak list under it
Eye diagram with TIE charts, bathtub and jitter breakdown Analog channel with three logic analyser lines

All pictures are screenshots of a DHO924S running OOS. More in the gallery. Guides are in the wiki.

Thanks

OOS builds on the work of these projects. Thank you to everyone behind them:

  • NovaOS by Olympian LED, Inc., for publishing the GPL source of its Linux port to this hardware, which showed what a kernel needs here and where OOS started. The patches, device tree and configuration of the OOS kernel are written anew today. Its install notes also helped with the loader's image format.
  • Norbert Kiszka, for the findings about this hardware he shared in public.
  • Linux, the kernel underneath everything, and Rockchip for the board support it runs on here.
  • Xilinx XDMA driver, which connects the SoC to the FPGA over PCIe.
  • BusyBox, the userland of the image.
  • e2fsprogs by Theodore Ts'o, which checks the data partition at every start.
  • wpa_supplicant by Jouni Malinen and contributors, for WLAN.
  • linux-firmware and Realtek, for the firmware of the WLAN stick.
  • Rust and the libc crate, the only dependency of the OOS code on the scope. The Windows desktop build also uses minifb and windows-sys for its window and network.
  • Roboto, the typeface of the screen.

Sources and licences of the kernel parts are listed in kernel/README.md.

Contents

Disclaimer

Use OOS entirely at your own risk. OOS is provided "as is", without warranty of any kind, express or implied, including but not limited to merchantability, fitness for a particular purpose and non-infringement. To the maximum extent permitted by applicable law, the authors and contributors are not liable for any damage or loss arising from its use or from following these instructions. That includes damage to the instrument, to connected equipment or devices under test, loss of data or calibration, lost warranty, wrong measurements, injury and any consequential loss.

Installing OOS means that you accept in particular the following risks:

  • Warranty. The boot card is inside the instrument. Installing OOS with a second card means opening the scope, and that voids the warranty. The USB install does not open it, but it changes the card, and nothing here promises that your warranty survives that. If it goes wrong, you may have to open the scope anyway.
  • Instrument damage. OOS drives the hardware directly: FPGA, ADC, front ends, sample clock, fan, relays and the generator output. A software fault can leave hardware in a state the stock firmware would never select. A failed fan control or a wrong setting can cause overheating or damage.
  • Data loss. A mistake while writing the card can make the scope unbootable or destroy the factory calibration stored on it. Without a good copy of your original card this data cannot be replaced.
  • Licences. Option licences of the stock system have been seen to stop working after running OOS, and had to be entered again. Keep your licence keys at hand.
  • Wrong measurements. OOS is not a calibrated or certified measuring instrument. Readings, trigger behaviour, decoders and analysis results can be wrong without any visible sign. Do not use OOS for safety-relevant, medical, legal, commercial or compliance measurements, and never rely on it to decide whether something is safe to touch.
  • Electrical safety. OOS changes nothing about the input ratings of the instrument. Observe the manufacturer's safety instructions and ratings. The open instrument contains a mains power supply with dangerous voltages. Disconnect the mains and all probes before you open it, and close it again before you connect mains. Only open it if you know how to do this safely.
  • Network security. Apart from SSH (password or key, docs/network.md 7) OOS has no authentication: telnet (on by default, a shell without password), SCPI, VXI-11, HiSLIP (on a computer), the web remote and MCP are open to everyone who can reach the scope. The community signing key is public, so anyone on the network can also install an update. This holds for WLAN as well. Connect the scope to a trusted bench network only, never directly to the internet.
  • Experimental settings. System > Overclock and /oos/limits.conf can change the sample clock, limits.conf can also lift limits. Values outside the defaults are outside any rating and can make the scope unusable or damage it. Overclocked samples are worse and at 2 GHz wrong: see docs/models.md.

OOS is an independent project. It is not affiliated with, endorsed by or supported by RIGOL TECHNOLOGIES CO., LTD. Rigol and all other names are trademarks of their respective owners and are used here only to identify the hardware. Do not contact Rigol for support with OOS. The repository contains no Rigol code. At run time OOS uses the FPGA image already in the scope's flash, the calibration files on its own card and the stock software on that card, which it needs to read the scope's identity. It only reads them.

Supported models

OOS reads the model from /rigol/data/vendor.bin at start and adapts channels, logic analyser, generator and EXT trigger to it. The stock software has to be on the card for that; without it, set model = ... in /oos/limits.conf. Details and limits: docs/models.md.

Model Rated bandwidth Channels Logic analyser Generator EXT trigger Runs OOS
DHO802 / DHO812 70 / 100 MHz 2 - - yes not yet
DHO804 / DHO814 / DHO824 70 / 100 / 250 MHz 4 - - - a DHO804 runs it (user report)
DHO914 / DHO924 125 / 250 MHz 4 yes - - not yet
DHO914-EDU / DHO924-EDU 125 / 250 MHz 4 yes - - not yet
DHO914S / DHO924S 125 / 250 MHz 4 yes yes - a DHO924S runs it (developer's unit)

Each row is one hardware variant: its models differ only in the licensed bandwidth (docs/models.md 2.1), so a model whose row runs OOS counts as verified, and the USB install takes it without being told (docs/install-usb.md 4). The other models are prepared from the known model table and have never run OOS. The feature columns follow the model line-up; whether the EDU variants have the LA port is not confirmed. DHO1000, HDO1000/2000/4000 and MHO models are different boards and are not supported; docs/porting.md says what would carry over and how an owner can describe one.

Limits on all models:

1 channel 2 channels 3-4 channels
Sample rate per channel 1.25 GSa/s 625 MSa/s 312.5 MSa/s
Memory depth per channel 125 M 62.5 M 31.25 M
Memory depth with the LA on 31.25 M 12.5 M 10 M

For how the hardware works, see the hardware overview.

Features

Acquisition

  • Normal, peak detect, average and high-resolution modes (high resolution in software, it needs more samples than screen points); Auto or fixed memory depth up to 125 M points
  • Time base from 1 ns/div; roll mode from 200 ms/div, scan mode at slow time bases
  • Zoom window, pinch and drag on the touch screen
  • Auto set-up, then a bar with four views of the signal: a few periods, many periods, the rising or the falling edge
  • Channel bandwidth Auto (follows the sample rate, the default), Full, 20 MHz or a limit in 5 MHz steps

Trigger

  • Hardware trigger: edge, pulse, slope, video, pattern, duration, timeout, runt, window, delay, setup/hold, Nth edge
  • Protocol trigger (bus events found by the decoders)
  • Zone trigger: up to two boxes or polygons a waveform must or must not cross
  • Noise reject (wider comparator hysteresis); a slow, noisy edge is drawn on the edge you set, not on the other one

Display

  • Dots or vectors, colour grade, waveform histogram, dotted graticule
  • Waveform windows: the plot split into two windows side by side, two stacked, or four, each channel, math channel and the LA in a window of your choice, all on one time base
  • Full screen: one tap at the top right of the plot hides the top bar and the cards, one more brings them back
  • Text size Normal, Large or Larger for the bars, cards, measurement rows, menus and dialogs; backlight brightness
  • HDMI output as a mirror, as a separate waveform workspace, or laid out again at the monitor's size
  • the picture drawn on the GPU (Mali-T860, Panfrost; System > Graphics, CPU as before is the other choice): a third less load on the frame loop, a monitor scaled without CPU work (gpu/README.md); the web picture as JPEG from the video encoder (VPU)

Measurement and maths

  • 35 automatic measurements plus delay and phase between channels, 14 at once, with statistics
  • Time, voltage, tracking and XY cursors; DVM; frequency counter in the FPGA (reciprocal, up to 6 digits; frequency, period, totalize)
  • Second pane under the plot, as high as its content: spectrum with a peak list, results table with statistics, cursors and peaks, decoder events, or the trends of two measurements
  • Measurements labelled on the trace: level lines and arrows with their values
  • Up to four views to switch between (Display > Views): each keeps its windows, second pane, measurements, cursors and zoom; a swipe from the edge of the plot or the numbers in the top bar switch
  • Data logger: measurements as CSV at an interval from 1 s to 1 h, to the stick or the card
  • 8 math channels, also on each other, with free formulas (sqrt(CH1^2+CH2^2)): add, subtract, multiply, divide, integrate, differentiate, abs, sqrt, log, ln, exp, Ax+B, low/high/band-pass and band-stop filters, FFT
  • Reference waveforms with scale, offset, colour, name and CSV export and import, mask test

Protocol decoders (26)

  • Four decoders at once, with an event table you can export and that jumps to an event; DCC lists one command per row ("Loco 5 Fwd 50/128")
  • Serial: UART, UART 9-bit, I2C, SPI, Quad-SPI, I3C, 1-Wire, DS2482, SWD, JTAG
  • Automotive and aerospace: CAN, CAN-FD, LIN, FlexRay, SENT, ARINC 429, MIL-STD-1553
  • Audio, lighting, industrial: I2S, S/PDIF, DMX512, Modbus RTU, Modbus ASCII
  • Other: USB low/full speed, USB PD, parallel
  • Model railways: NMRA DCC (contributed by Arjen Halma), with a view of the layout in Display > Second pane > Bus view: locomotives, turnouts, signals, and the track status, green while live and red after an emergency stop
  • New decoders come as protocol modules: one file, one registration (docs/protocol-modules.md)
  • New measurements come as measurement modules the same way (docs/measurement-modules.md)

Analysers

  • Spectrum analyser: resolution from the whole record, span that follows the signal in the pane, fundamental and harmonics found as numbered peaks, RBW, trace modes, waterfall, THD, SNR, SFDR, limit line from a trace
  • Eye diagram with voltage and UI axes, density colours, TIE trend, histogram and spectrum, bathtub curve. Jitter split into TJ, RJ and DJ (dual-Dirac model) and measured DCD, DDJ and PJ, pooled over records
  • Power analysis: quality, harmonics, switching, ripple
  • Bode plot with the built-in generator or an external one on the LAN or the USB-A port (APPL or BSWV command sets, a UTG900 preset, generic SCPI), or from one record of a generator that sweeps on its own and marks the sweep start on a sync output
  • Identify: names a signal and sets up a trigger and decoder for it
  • Bandwidth test: rise time, overshoot and magnitude response from a fast edge

Logic analyser (models with an LA port, PLA2216 probe)

  • D0..D15, hardware trigger on the digital lines, also in roll and scan mode. Thresholds are set as under stock, but on the unit tested so far neither system changes the level the lines switch at

Generator (S models)

  • Sine, square, ramp, pulse, noise, DC, arbitrary wave (also captured from a channel), AM, FM, PM

Remote control

Interface Port Purpose
SCPI over TCP 5555 SCPI manual: DHO800/DHO900 subset and OOS extensions; RAW reads retained native CH memory, and references retain their own native timing
VXI-11 111, 9009 on the scope, where port 111 is free: TCPIP::<ip>::INSTR
HiSLIP 4880 on a computer: the payload is the same SCPI interpreter; TCPIP::<ip>::hislip0::INSTR
Web remote 8080 live screen, keys, knobs, touch in the browser; saves screenshots and CSV to your computer
LXI identification 8080 /lxi/identification
LAN announcement 5353 mDNS of the SCPI socket, VXI-11 and HiSLIP; the HTTP record's path is /lxi/identification
MCP 8080 POST /mcp: tools scpi and screenshot for AI assistants
SSH 22 root shell with the scope's own password or a trusted key, off by default (docs/network.md 7)
mDNS, DNS-SD 5353 (UDP) the scope by name, http://dho924s-123456.local:8080, and its services for browsing (docs/network.md)

None of them slows the scope down: they are read without waiting, and the live picture of the web remote is made on the slow cores with spare time only (on a DHO924S the screen stays at 30 frames a second with two web viewers). All of them run over Ethernet and over WLAN with a USB stick in the front port (RTL8188EU; open, WPA and WPA2 personal networks, see docs/wlan.md).

System

  • Own cold boot of all hardware: the stock system never has to run first
  • Self-calibration into own files (/oos/cal); factory files are never changed
  • System > Overclock: the sample clock in steps from 1.25 to 2 GHz, experimental, from the next power-on
  • Saves setups, CSV, binary waveforms and PNG, also to a USB stick; System info page with model, temperatures and limits
  • System > Date and time: the clock from an NTP server (off by default), time zones with daylight saving time, or set by hand; once the clock is set, file names carry the local date and time
  • System > Network > 10 Mbit retry: an Ethernet link that comes up at 10 Mbit/s gets one more autonegotiation
  • On-screen keyboard for names, formulas and WLAN passwords, with arrow keys to correct inside a long entry
  • The start-up screen shows the version and the build
  • Signed update packages with trial start and automatic rollback

Gallery

Results pane Trend pane
Results pane: every measurement with statistics, peaks beside it Trend pane: two measurements over time
Labels on the trace Spectrum
Measurements labelled on the trace Spectrum view with its peak list
Main screen System menu
The main screen, 200 kHz from the built-in generator System menu
Auto set-up views Full screen
After Auto: a few periods, many periods, rising or falling edge Full screen, the same button goes back

Status

Area State
Boot, cold boot, acquisition, trigger, roll and scan, touch, front panel, generator (sine, built-in Bode), self-calibration run on a DHO924S
Signed updates from the web page and the shell, kexec trial start, trial and confirmation, install over ADB run on a DHO924S
An update with another device tree, tried by kexec first (kexec-tools, from 0.1.7) run on a DHO924S: 0.1.6 to 0.1.7 to 0.1.8 through the web page, with cold starts
System > Graphics = GPU, JPEG live picture from the video encoder run on a DHO924S, on the panel and with a 1920x1080 monitor in Mirror, Waveform and Layout
Frequency counter in the FPGA, backlight, AC/DC by a long press run on a DHO924S (the counter with the built-in generator, 1.5 Hz to 9.9 MHz)
Logic analyser with a PLA2216: lines, pulse widths, edge, pulse, pattern, duration and protocol trigger, UART, SPI and I2C on the lines, roll, scan, whole deep records, CSV run on a DHO924S, three lines (D0 to D2) driven; thresholds have no effect here, under stock neither
Generator modulation (AM, FM, PM), deep memory, limits, web, MCP, VXI-11 run on a DHO924S
HDMI output run on a DHO924S
Automatic rollback of a bad update tests on the host only
USB install without opening the scope run on a DHO924S with a modified stock system: dry run, first install, run again
Generator noise, system info, bandwidth test tests on the host only
Bode with a free-running sweep tests on the host only (synthetic sweeps); the scan path for sweeps above about 0.9 s is not yet tried on a unit
Bode with a generator on USB (USBTMC), UNI-T UTG900 preset tests on the host only (a simulated USBTMC device); no generator on USB tried yet
USB storage stick, 10:1 probe run on a DHO924S
WLAN driver, firmware and scan run on a DHO924S with an RTL8188EU stick; joining a network tested on simulated radios only
Overclocking (System > Overclock) run on a DHO924S: 1.5 GHz with more noise, 2 GHz with wrong samples; the default stays 1.25 GHz
Spectrum, eye and jitter, results and trend panes, measurement labels, Auto run on a DHO924S with the generator and an RF source
Protocol decoders tested with simulated signals; only some with real signals
All models other than the DHO924S never run
Hardware averaging, 800 ps/div not implemented

The technical documents in docs/ say for each topic whether it is verified on the unit.

Known limits:

  • Generator DC level: the output's middle jumps by about 85 mV where the generator switches its range at 2 Vpp. Whether the stock system shows the same is not known yet.
  • High resolution only gains where the record has more samples than the screen has points.
  • Logic analyser: D3 to D15 were not driven with a signal yet.
  • WLAN: joining a network has not been tried on the unit.

Try it without a scope

On Windows, with Rust installed, build and open the desktop window from PowerShell:

.\build-windows.ps1 -Run

The app is ui\target\release\oos-ui.exe. Mouse clicks and drags act as touch; Space toggles Run/Stop. Plain mouse wheel pans horizontally, and Ctrl+wheel zooms the time scale around the pointer. F12 saves a PNG in Documents\OOS. Use --offline to start with the analog channels off for stored waveforms. Keyboard controls are listed in ui/src/desktop.rs.

For development, run the checkout and automatically restart after saving source changes:

.\run-windows.ps1 -Watch -Offline -WebPort 18080 -ScpiPort 5555 -HislipPort 14880

Rust compiles changed code automatically. The window includes front-panel buttons and knob controls. Use Reference > Load file or Ctrl+O to open CSV, OOS BIN, or WFM files; the web remote at http://localhost:18080 also accepts file selection and drag-and-drop. Loaded sources appear as R1–R10 cards. SIM (start menu, Analysis) starts a simulated reference; Run/Stop, Single, and trigger settings control its acquisitions. Live restores the live session. Measurements follow each captured window and recompute when a stopped reference is panned. Measure opens categorized choices with Source, Settings, and Selected; large readout lists have page controls. The Windows app announces its actual SCPI and HiSLIP listeners over mDNS.

SIM > Advanced adds SSC profile, deviation and modulation frequency, duty-cycle distortion, and correlated random jitter with its corner frequency. PRBS-13 is available alongside the other patterns. With SSC enabled, the stored record covers a complete modulation cycle at eight samples per bit. Long records generate in the background; cancel or return to Live to keep the previous session. Configurations exceeding the generation budget report an error without replacing the current waveform. The HSS down-spread profile removes its DC term; centered spread uses plus/minus the configured deviation. Choose Auto Eye/Jitter in the analysis menu/settings to analyze the selected live or reference source. Automatic setup recovers an NRZ clock/rate, chooses voltage thresholds from the signal and opens the eye with its TIE trend, histogram, spectrum and bathtub. The source/rate header keeps manual rate and explicit-clock settings accessible. Flat, insufficient or sparsely sampled data shows its limit; model estimates are labeled. The Eye analyzes a full stored reference once per changed record or setting, including while the trace is zoomed; large files show Computing without blocking navigation. Live captures accumulate; stopped panning does not add observations. Ordinary trace measurements use the selected Screen or Full record gate.

The same advanced settings are available through OOS SCPI. Values use seconds, hertz and fractional deviation (0.005 means 0.5%). Configure them together, then start generation and poll :SIM:BUSY?:

:SIM:PRESET "PCIe 3.0"
:SIM:SSC:MODE CENTER
:SIM:SSC:DEVIATION 0.005
:SIM:SSC:FREQUENCY 33000
:SIM:JITTER:DCD 4e-12
:SIM:JITTER:CORRELATED 2e-12
:SIM:JITTER:CORNER 2e6
:SIM:PATTERN PRBS13
:SIM:PLAY ON
:SIM:BUSY?
:SYSTEM:ERROR?

OOS builds on macOS and Linux and can run scripted without hardware, with its simulated demo signals. It writes a screenshot in PPM format next to the script:

cat > /tmp/demo.txt <<'EOF'
frames 30
shot demo.ppm
EOF
cd ui && cargo run -- --script /tmp/demo.txt

The commands are listed at the top of ui/src/cmd.rs. Add --model DHO804 to act as another model.

To try the web remote with the same demo signals, run this and open http://localhost:8080/:

cd ui && cargo test web_demo -- --ignored --nocapture

It runs for 5 minutes.

Installation

There are three ways:

Way Opens the scope Your original card State
Second card, steps 1 to 8 below yes stays untouched in a drawer run on a DHO924S
USB stick no OOS goes on it, beside stock run on a DHO924S with a modified stock system
ADB over the network no OOS goes on it, beside stock run on a DHO924S with a modified stock system

From a GitHub release, without building

The latest release has ready-made files. You need no Rust and no Docker for them:

File What it is for
DHO800_DHO900_OOS_Install.GEL install from a USB stick through the stock system, without opening the scope: go on at From a USB stick
oos-<version>.img install on a second card: steps 1, 2 and 6 to 8 below, with --image oos-<version>.img in step 6. Steps 3 to 5 are the build, skip them
oos-<version>.oosupd update a scope that already runs OOS: open http://<scope>:8080/update and choose the file, then switch off at the mains, wait 30 seconds and switch on. From 0.1.6 or older, first oos-0.1.7.oosupd from the 0.1.7 release: later builds bring another device tree, which only 0.1.7 and later can try before they install it
SHA256SUMS the checksums of all of them

Check what you downloaded. The number has to be the same as in the file's line of SHA256SUMS:

shasum -a 256 DHO800_DHO900_OOS_Install.GEL      # macOS
sha256sum DHO800_DHO900_OOS_Install.GEL          # Linux
certutil -hashfile DHO800_DHO900_OOS_Install.GEL SHA256      # Windows

ADB needs steps 3 to 5 to build the image.

On a second card

The steps below use macOS, where they were developed. tools/sdcard-clone.sh needs macOS; on Linux, use dd for the clone and /dev/sdX instead of /dev/rdiskN. That path is untested. Steps 1 and 2 on Windows and Linux, with the tools to use and what to watch out for: docs/sdcard-backup.md.

You will need for the second card

  • A DHO800/DHO900. The boot SD card is inside, so you have to open the scope, which voids the warranty
  • A second SD card, best of the same size or larger. OOS is only ever installed on this card. A smaller card works too (step 2), down to about 8 GB on a stock card.
  • A card reader
  • Python 3 and this repository (git clone https://github.com/dekajoule/oos.git)
  • To build the image yourself, not with a file from a release: Rust with rustup target add aarch64-unknown-linux-musl, and Docker, running. A Rust from the distribution's packages usually lacks that target and rust-lld. Hosts: macOS on Apple silicon, Linux on arm64 or x86-64. On Linux, run the scripts as yourself, not with sudo: put yourself in the docker group (sudo usermod -aG docker $USER, then log in again). On x86-64 the kernel is cross-compiled; the image's busybox, wpa_supplicant and e2fsck come from arm64 containers, which need QEMU once: docker run --privileged --rm tonistiigi/binfmt --install arm64. The workflow .github/workflows/image.yml builds it all on both Linux hosts. Step by step: Building on Linux.

The whole process takes about an hour, mostly for copying the cards.

1. Back up the original card

This step protects your factory calibration. Do not skip it.

  1. Switch the scope off, unplug the mains cable and all probes, open the instrument and take out the boot SD card.
  2. Put the card in the reader and find its disk number:
    tools/sdcard-clone.sh list
  3. Read the whole card into an image. The tool also writes a checksum and a layout report:
    tools/sdcard-clone.sh read diskN ~/oos-backup/sd-original.img
  4. Keep the image in at least two places, then put the original card away. From here on you only use the second card. On Windows or Linux: docs/sdcard-backup.md. Always the whole card, never a partition, and never let the computer format or initialise it.

2. Write the clone to the second card

tools/sdcard-clone.sh list
tools/sdcard-clone.sh write ~/oos-backup/sd-original.img diskM    # asks you to type the disk id, then verifies

Cards of the same nominal size differ by a few MB. If the second card is smaller than the image, write refuses and names the way out: fit makes a copy of the image for that card. The last partition, userdata (the stock /data, about 1.4 GB used on a stock card), runs to the end of the card; fit checks its ext4 and shrinks it in Docker, as far as the card needs. The original image is only read.

tools/sdcard-clone.sh fit ~/oos-backup/sd-original.img diskM ~/oos-backup/sd-fit.img
tools/sdcard-clone.sh write ~/oos-backup/sd-fit.img diskM

On Linux, give the card's size in bytes instead of diskM (lsblk -bdno SIZE /dev/sdX), and write sd-fit.img with dd.

Put the second card into the scope, close the instrument and start it once. The stock system must work as before, with its calibration and licences. Then unplug the scope and take the card out again.

3. Build the kernel

Download linux-6.12.115-base.tar.xz from the releases into kernel/src/ (kernel/README.md), then:

kernel/build-base.sh        # in Docker, 5-30 minutes depending on the machine, result in kernel/out/base

You only have to repeat this when the kernel changes.

4. Signing key

Update packages must be signed. To let everyone build updates for every OOS scope, the repository includes a public community key, keys/community-signing.key, and all builds trust it. You do not have to do anything: the build uses it automatically.

The community key only protects against damaged packages. It says nothing about who built one, so only install packages from people you trust.

If you want a scope to accept only your own builds, create your own key before you build:

cd fpgad && cargo run --release --bin oos-update -- keygen && cd ..

Replace all keys in keys/update.pub with the line it prints. The secret key is in ~/.config/oos/update-signing.key. Back it up and never publish it. Details: docs/update.md.

5. Build the image

boot/build-dev-image.sh

This produces boot/out/oos-dev.img for the card, boot/out/oos-dev.oosupd, the signed update package, and boot/out/DHO800_DHO900_OOS_Install.GEL for the USB stick. If the script fails, the previous image stays in place, so check the file's time.

Building on Linux

Steps 3 to 5 on Linux, here with Debian or Ubuntu, on an ordinary x86-64 PC as well as on arm64. On x86-64:

  • the kernel and oos-hw are cross-compiled with Ubuntu's gcc-aarch64-linux-gnu inside the build container; you install no cross compiler yourself,
  • the Rust programs are cross-compiled by rustup's aarch64-unknown-linux-musl target and rust-lld,
  • busybox, wpa_supplicant and e2fsck come from arm64 containers, which run through QEMU (the binfmt line below). docker run --rm --platform linux/arm64 alpine:3.22 uname -m prints aarch64 when that works.

Run everything as yourself, not with sudo.

sudo apt install docker.io git python3 curl
sudo usermod -aG docker $USER      # then log out and in again, so that docker runs without sudo
curl --proto '=https' --tlsv1.2 -sSf https://sh.rustup.rs | sh      # Rust from rustup, not from apt
rustup target add aarch64-unknown-linux-musl
# x86-64 only: arm64 containers through QEMU, for busybox, wpa_supplicant and e2fsck (again after a reboot)
docker run --privileged --rm tonistiigi/binfmt --install arm64

git clone https://github.com/dekajoule/oos.git && cd oos
mkdir -p kernel/src
curl -fL -o kernel/src/linux-6.12.115-base.tar.xz \
  https://github.com/dekajoule/oos/releases/latest/download/linux-6.12.115-base.tar.xz
kernel/build-base.sh
boot/build-dev-image.sh

The scripts say what is missing before they start: Docker not reachable, no rustup or no target, no arm64 containers. On x86-64 the first build takes longer than on arm64, mostly for wpa_supplicant and e2fsck under QEMU; they are built once. A finished build leaves the same files as on macOS. The workflow .github/workflows/image.yml builds on arm64 and on x86-64 for every release and compares the kernel, the DTB and the files inside the image of the two. To install them on a second card from Linux, see steps 1, 2 and 6, with /dev/sdX for the card.

6. Install OOS on the second card

Put the second card in the reader. Unmount it, then do a dry run, which only checks the card and prints the plan. With a file from a release, write --image oos-<version>.img instead:

diskutil unmountDisk /dev/diskM
sudo python3 boot/card-install.py install /dev/rdiskM --image boot/out/oos-dev.img --fallback-stock

The tool refuses cards that do not have the stock layout. If the plan looks right, write it:

sudo python3 boot/card-install.py install /dev/rdiskM --image boot/out/oos-dev.img --fallback-stock --execute

This saves the current recovery partition to backups/, writes OOS into recovery, reads it back, and copies the stock boot image into the empty backup partition. That copy is the fallback if the loader refuses OOS.

Now select OOS for the next start:

sudo python3 boot/switch.py oos /dev/rdiskM --execute
sudo python3 boot/switch.py show /dev/rdiskM

7. First start

  1. Eject the card, put it into the scope, close the instrument, connect Ethernet and switch on.
  2. You see the Rigol logo from the stock loader, then the OOS start-up screen with a checklist.
  3. The scope screen appears. Each failed step is named on the screen. A missing calibration file is a warning: the scope then runs on defaults and is less accurate.

The IP address comes from DHCP and is shown in the top bar. Without DHCP the scope takes a link-local address (169.254.x.y, as computers do): a computer connected straight to the scope reaches it without any set-up.

8. Choose how OOS starts

By default OOS is one-shot: every start of OOS restores the stock boot, so the next power-on starts the stock system. This is the safe mode for a new installation.

To start OOS once more, run this in an SSH session (or on the serial console) and power-cycle the scope:

oos-boot-oos-again

When OOS works for you, make it the normal system: set System > Boot mode to Persist, or run oos-update mode persist. It counts from the next power-on. One-shot goes back, and the next power-on starts stock.

Even then, a start that does not complete leaves the stock boot in place, so the next power-on starts the stock system.

Without opening the scope

Both ways install OOS from the running stock system onto the card that is in the scope. The USB stick takes the update file of the release or of your build (steps 3 to 5); ADB needs the build.

Read this before you start

  • Both ways have run on one DHO924S only, whose stock system is a modified one. Try them on a card you can take out if you can.
  • There is no second card to fall back on. A refused image is harmless, the loader starts the stock copy. But if the kernel hangs before the first script of the image runs, every power-on hangs the same way. The card then has to come out, so the scope has to be opened after all.
  • Only the DHO924S is accepted, the only model OOS has run on. See the disclaimer.

The install writes recovery, the first 32 MiB of backup and, as its very last step, the 4 bytes of boot that select OOS. A failure or power cut before that step leaves a card that starts stock as before, and running the same install again finishes the job. No stock update step runs, and the FPGA flash and /rigol are not touched. Details: docs/install-usb.md.

From a USB stick

You need a FAT32 USB stick with at least 200 MiB free, and DHO800_DHO900_OOS_Install.GEL: download it from the latest release and check it against SHA256SUMS, or take it from boot/out/ of your own build.

  1. Copy the file to the top folder of the stick. Keep the name: the scope ignores a file whose name does not end in .GEL and contain DHO800_DHO900.
  2. For a dry run, put an empty file oos-dry-run.txt next to it. This runs all checks and saves the rescue set, without writing the card.
  3. Start the stock system, put the stick into the front USB port, open Storage > Upgrade, choose the file and start it. This takes about a minute. The screen says at the end whether it worked. If Storage does not show the stick, switch the scope off and on and look again (docs/install-usb.md, section 5). If the list also has a small file starting with ._, that one comes from macOS: choose the real file of about 16 MB.
  4. Read oos-install.log on the stick on a computer. It should end with exit code 0.
  5. Delete oos-dry-run.txt and run the update again. The log should end with OOS selected for the next power-on and exit code 0.
  6. Copy the folder OOS-rescue from the stick to a computer and keep it. It holds your calibration (rigol-data), the stock recovery and the start of the card.
  7. Switch the scope off at the mains, wait 30 seconds and switch it on. OOS starts.

The scope does not restart by itself after this update. OOS starts once: the power-on after it starts stock again. To stay on OOS, set System > Boot mode to Persist. Later versions go in through the .oosupd file of a release.

Over ADB

You need adb on your computer and a scope that answers on its network port 55555 with root access. This is known from a modified stock system; it has not been checked on an unmodified one.

adb connect <scope>:55555
adb root
adb connect <scope>:55555        # adb root drops the connection

# your calibration and licences, onto your computer
adb pull /rigol/data rigol-data

# the tool for the scope, not the one in fpgad/target/release
adb push fpgad/target/aarch64-unknown-linux-musl/release/oos-update /data/local/tmp/
adb push boot/out/oos-dev.oosupd /data/local/tmp/
adb shell chmod 755 /data/local/tmp/oos-update

# dry run: all checks, the rescue set, the card is not written
adb shell /data/local/tmp/oos-update gel-install /data/local/tmp/oos-dev.oosupd --save /data/local/tmp/OOS-rescue

# the rescue set onto your computer: keep it
adb pull /data/local/tmp/OOS-rescue

# the install: last line "OOS selected for the next power-on"
adb shell /data/local/tmp/oos-update gel-install /data/local/tmp/oos-dev.oosupd --save /data/local/tmp/OOS-rescue --execute

Before the last command, check the rescue set on your computer: run sha256sum -c SHA256SUMS in OOS-rescue (shasum -a 256 -c SHA256SUMS on macOS). After the install, switch the scope off and on. OOS starts.

The rescue set takes 132 MiB on the scope. Afterwards you can remove it with adb shell rm -rf /data/local/tmp/OOS-rescue /data/local/tmp/oos-update /data/local/tmp/oos-dev.oosupd.

After the install

OOS starts once, then the next power-on starts stock again (step 8). To start OOS once more, run the same install from the stock system: it writes nothing but the selection. To stay on OOS, use System > Boot mode > Persist on OOS.

The stock recovery is replaced by OOS. Everyday stock use does not need it, but anything that starts into it no longer works. Putting it back needs the card in a reader, with recovery.bin from the rescue set and boot/card-install.py restore.

Daily use

Controls. Front-panel keys and knobs work as labelled. The Menu button at the bottom left reaches every function. A channel key held for more than half a second, or a finger held on a channel's card, switches that channel between AC and DC coupling. A short press switches a channel that is off on and opens its menu. With several channels on, the first press on one that is not selected only selects it, so the knobs act on it (its card has the coloured border); the next press opens its menu, and a press with its menu open switches it off. A tap on a channel's card selects and opens the menu the same way; a tap with the menu open closes it.

Backlight. Display > Backlight sets the panel's brightness from 10 to 100 %, in steps that look even to the eye. It is a setting of the scope (/oos/system.conf).

Auto. Works on the channels that are on, at full bandwidth, and sets the memory depth back to Auto; each channel then gets its own bandwidth back. With no signal it restores the set-up. Afterwards a bar at the top of the plot offers a few periods, many periods, the rising edge or the falling edge of the trigger channel; its x or a tap elsewhere closes it.

Windows and full screen. Display > Windows splits the plot into two windows side by side, two stacked, or four. The same page puts each channel, math channel and the LA into a window; a new split spreads the channels that are on. All windows share the time base, and a drag in a window moves a channel of that window. Zoom, XY and the analysers use one window. The button with four corners at the top right of the plot gives the plot the whole screen; it shows inward corners then and brings the top bar and the cards back. The box button under it arms one drag: the next drag on the plot draws a box, and that box is the zoom window. A tap does not zoom.

Views. Instead of one screen with everything on it, Display > Views (2, 3 or 4) gives screens to switch between. Each view keeps what is shown and where: the windows, the second pane, the measurements and their bar, DVM and counter, the cursors, the zoom, the histogram, the analyser page, XY and full screen. The channels, the time base, the trigger and the acquisition are the same in all of them; what changes while a view is shown stays with it, and a view not used yet starts with the plot alone. To switch: the numbers left of the top bar's buttons, a swipe from the left or right edge of the plot inwards (a vertical drag there still moves a channel or the trigger level), the Quick key set to Next view, or SCPI :DISPlay:VIEW <n> (:DISPlay:VIEW:COUNt <1..4>). The views are saved with a setup.

Text size. Display > Text size makes the text larger: Normal is the original look, Large and Larger use fonts 2 and 4 pixels bigger in the top bar, the cards, the measurement and cursor rows, the menus, the keyboard and the dialogs. The rows under the plot grow with them, so the plot gets a little shorter. Where a long text would not fit (a narrow channel card with four channels on, a long button label in the start menu, a narrow table column) it stays at the next smaller size, and the dense figure tables of the eye / jitter view keep the normal size. The setting is kept with the other preferences and across restarts; Default set-up and Recall keep it.

Bandwidth and noisy signals. A channel's bandwidth is Auto by default: the limit follows the sample rate, as on the stock system. With Full, the noise of a slow signal can be larger than the trigger hysteresis and the hardware triggers on the other edge too; the display still shows the edge you set, and Trigger > Noise reject widens the hysteresis.

Keyboard. Names, formulas and WLAN passwords are typed on the on-screen keyboard. The arrows either side of Space move the insertion point, a tap into the entry puts it there; typing and Delete work at that point.

Generator. Tap the frequency in the generator window for a keypad with units; the limits apply by themselves. The - and

  • buttons step it. Changes inside one amplitude range take effect at once and keep the output running.

Analysers. Menu > Analysers holds Spectrum, Eye / jitter, Power analysis, Bode and the bandwidth test. Eye/Jitter opens as a full analysis page with optional side or lower panes and has source/rate settings and Close in its pane header. Other analyser views use the button with three dots at the top right for Exit and Settings.

Bode with an external generator. In Analysers > Bode pick the Generator preset (Rigol DG, Siglent SDG, UNI-T UTG900 for the UTG932 and UTG962, or SCPI for one that takes FREQ and VOLT), then Connection: LAN with Gen address (IP, port 5555 if none is given; the knob moves the last number) or USB for a generator in the USB-A port of the scope. On USB the scope takes the first USBTMC instrument it finds (no PC, no driver), asks it for *IDN? and shows the answer; without one the sweep stops with the reason (no USB device, a device that is not USBTMC, no permission). Rigol DG and Siglent SDG generators are USBTMC instruments as well. The scope sets channel 1 of the generator to a sine of Amplitude (Vpp) without offset, switches its output on and steps through the frequencies. Over SCPI, :BODE:GENerator "usb" selects USB and :BODE:GENerator "192.168.1.20:5025" the LAN again.

  • UNI-T UTG900 commands: :CHANnel1:MODe CONTINUE, :CHANnel1:BASE:WAVe SINe, :CHANnel1:AMPLitude:UNIT VPP, :CHANnel1:BASE:AMPLitude, :CHANnel1:BASE:OFFSet 0, :CHANnel1:BASE:FREQuency, :CHANnel1:OUTPut ON, from the UNI-T UTG900 series programming manual (REV 00, 2022-07-15; the English UTG900E manual has the same commands). Not yet tried with a real UTG900.

Bode with a free-running sweep. For a generator that the scope does not control, but that sweeps on its own and gives a sync (marker) pulse at the start of each sweep. Wire the generator to the input of the device under test and to the input channel (CH1), the output of the device to the output channel (CH2), and the sync output to CH4. In Analysers > Bode set Generator = Free-running sweep, then the same Start freq, Stop freq, Sweep time and Sweep (Lin or Log) as on the generator, the Sync channel, its edge and level (the sync pulse must cross the level; set the channel's scale so the pulse is on the screen). Input (ref) Off compares the output with Ref level in dBV (0 dBV = 1 V RMS) instead of an input channel. Points is the number of frequencies read from the sweep. Start / stop sweep sets the time base and the memory for one sweep, triggers once (SINGLE) on the sync edge and waits; start the sweep on the generator. The plot shows the gain over frequency, the settings come back afterwards.

  • Each frequency is read in a short window of the record, about 4 periods long and never wider than 25 % in frequency, by a fit of a sine that follows the sweep. Where the sweep passes a frequency in less than one period, that frequency is left out (the message says so). Over three decades, 20 Hz needs a sweep time of a few seconds; a linear sweep needs much more time for its low end than a logarithmic one.
  • Phase comes from the fit of both channels and is shown only with an input channel, where both fits are clean.
  • Sweeps up to about 0.9 s run as normal records (100 ms/div at most), the trigger one division from the left edge. Longer sweeps run in scan mode (Auto Roll off during the sweep, up to 200 s/div, 500 s and more): the trigger sits at the centre, the sweep in the right half, and the record holds min/max pairs. There the gain is half the peak-to-peak value in each window, and there is no phase. The start of the sweep is taken from the sync edge in the record itself.
  • On a 2-channel model use CH1 for the output, CH2 for the sync and Input (ref) Off.
  • :BODE:RUN ON starts it over SCPI, :BODE:DATA? returns the points (phase NaN where there is none).

Panes. Display > Pane puts a second view under the waveform: Spectrum with a peak list, Results with statistics, cursors and peaks, decoder Events, or Trend with two charts. Tap the pane's title for its settings, a trend chart to change its measurement, the peak list's button to sort it. The x closes the pane.

Measurements. A default set-up shows six in the strip under the plot. Measure > Dock moves that strip to the left, the right, or above the trace. In Measure > Add item a tap adds a measurement of the source channel and a second tap removes it. Measure > Labels on trace draws level lines and arrows with their values on the waveform.

Overclocking. System > Overclock sets the sample clock from the next power-on. Above 1.25 GHz the noise rises, and 2 GHz gives wrong samples: it is for tests only. See docs/models.md.

Web remote. Open http://<scope>:8080/. Click on the picture to touch the screen, drag to swipe. It scales with the window, so it also works on a phone. The buttons at the bottom save a screenshot or the last record to your computer; records above 2 million points have to be saved on the scope or read over SCPI. The live picture is a PNG of about 90 KB; "Live picture format" can switch it to the uncompressed 1.8 MB BMP, or to a JPEG of about 75 KB that the scope's video encoder makes at under a third of the processor time of a PNG (text a little less sharp; screenshots stay PNG). The choice is kept in the browser. The PNG is made off the scope's frame loop, only of a changed screen, up to 20 a second (about 13 reach a browser over Ethernet); the page gets each new picture as soon as it is made, and while the screen stands still it gets "not modified" instead. The scope's own screen does not slow down for it. Pause stops the pictures, and a tab in the background stops them too. The Update link leads to the update page.

Files. Setups are kept on OOS's own persistent area /oos and survive a power cycle. Screenshots and CSV files go to a USB stick in the front port (FAT32, exFAT or ext4), into the folder OOS, and can be pulled whenever nothing is being saved. Without a stick they go to /tmp/oos, which is in RAM and lost at power-off, unless you set another directory with --store-dir. The web remote saves them to your computer too. /oos holds 16 MiB for calibration and settings.

Self-calibration. System > Self-cal. Let the scope warm up for 30 minutes and disconnect all inputs first. It takes about 5 minutes per channel and pass, with 4 passes. Results go to /oos/cal and are preferred over the factory files, which are never changed.

Updates. Take oos-<version>.oosupd from the latest release, or build a package yourself (boot/out/oos-dev.oosupd), then install it on the running scope:

curl --data-binary @oos-<version>.oosupd http://<scope>:8080/update

or open http://<scope>:8080/update in a browser. The scope restarts into the new build by kexec before anything is written, and the new build installs itself from there; if its kernel hangs, a power-cycle starts the previous build again. After the install, power-cycle: that start is the trial (coming from 0.1.0, which has no kexec start, too). From 0.1.6 or older go to 0.1.7 first: 0.1.8 and later bring another device tree (the GPU and the video encoder on), and only 0.1.7 and later start such an image by kexec with its own tree; 0.1.6 refuses it. The new build runs on trial. If it crashes in a loop or never becomes stable, the previous image is written back. System > Update shows the state and System > Roll back update returns to the previous image. Details: docs/update.md.

Network. Tap the network box at the top right: it shows the addresses of Ethernet and WLAN and the address of the web remote. For WLAN, put an RTL8188EU stick into the front USB port, tap Find WLAN networks, tap a network and enter the password. It joins by itself from then on. Everything open on Ethernet is then open on that network too. Details: docs/wlan.md. The page also shows the speed of the Ethernet link; a link at 10 Mbit/s gets one more autonegotiation (10 Mbit retry, on by default, docs/network.md).

Date and time. The scope has no clock battery and starts in 2013. System > Date and time > Time from NTP (off by default) sets the clock from pool.ntp.org or another server whenever a network link comes up, and every hour; Time zone picks the zone with its daylight saving rules (or takes a POSIX TZ string), Set the clock takes it by hand. From then on file names carry the local date and time (shot-20261111-143005.png) instead of a number. The settings are in /oos/system.conf, see docs/network.md.

Waveform files. Storage saves CSV and a compact binary file wave-NNN.bin (wave-<date>-<time>.bin once the clock is set), little endian: OOSW, u32 version (1), u32 channels, u64 samples per channel, f64 dt, f64 t0, then per channel its number (u32) and the samples (f32, volts). Both hold the record on the screen.

Experimental limits. /oos/limits.conf overrides limits for your own tests. Every applied value is shown at start and in the System info. See the disclaimer and docs/models.md.

If something goes wrong

Your scope can always be recovered as long as you have the image from step 1: the worst case is writing it to a card again. Unless noted, the fixes below need the card in the reader, so you have to open the scope again (diskutil unmountDisk first).

What you see Meaning What to do
The stock system starts instead of OOS one-shot mode, or the loader refused the OOS image and used the fallback boot/switch.py show, then select OOS again. If that repeats, rebuild the image.
Rigol logo stays, nothing else, on every start the kernel hangs before OOS runs sudo python3 boot/switch.py stock /dev/rdiskM --execute, then install a working image
Black screen; a Rockchip USB device (2207:330c) appears the loader refused recovery and has no fallback switch.py stock. If needed, sudo python3 boot/card-install.py restore /dev/rdiskM --backup backups/recovery-<date>.bin --execute
Start-up screen stops at a step a hardware step failed Read the stage on the screen. Logs are at /tmp/oos-boot.status and /tmp/oos-cold.log over SSH.
A new build misbehaves System > Roll back update, or oos-update rollback --execute
Nothing helps Write sd-original.img to the second card again (step 2)

Serial console: UART2, 115200 8N1. The stock loader also reports there why it refuses an image.

Going back to stock

  • In one-shot mode: power-cycle. System > Back to stock says the same.
  • In persist mode: System > Boot mode > One-shot, then power-cycle. Or, with the card in the reader: sudo python3 boot/switch.py stock /dev/rdiskM --execute
  • For good: put your original card back. After an install without opening the scope, see After the install.

OOS never writes the FPGA flash, /rigol/data, or the uboot, trust and parameter partitions.

Repository layout

Path Content
hal/ Hardware layer: FPGA register sequences, front ends, ADC, PLL, cold boot, models, updates
dsp/ Signal processing: triggers, measurements, maths, decoders, analysers
ui/ oos-ui: scope screen, SCPI, VXI-11, HiSLIP, web remote, LAN announcement
fpgad/ oos-fpgad bring-up tool and oos-update
boot/ Boot image packer, image build, card installer, USB installer, stock/OOS switch
rootfs/initramfs/ Init scripts and firmware of the image
rootfs/build-wlan-tools.sh, rootfs/build-fsck.sh Build wpa_supplicant and e2fsck in Docker
keys/ Public keys trusted for updates, community signing key
tools/ Card cloning and analysis, device inventory, Python models (README)
kernel/ Kernel source, own patches, device tree, configuration, build in Docker, licences (README)
CHANGELOG.md What changed between releases
docs/ Technical documentation: architecture, boot, hardware, register-level protocols (index)

Development

Each crate builds on its own. The hardware code is Linux-only, so it is checked for the target as well. tools/check.sh runs every check CI runs (the tests of all crates, the target build, the decoder builds, the file and script checks); tools/check.sh test runs one layer of them:

tools/check.sh
(cd ui && cargo test)                                 # one crate
(cd ui && cargo check --target aarch64-unknown-linux-musl)

Coding agents, and people new to the tree, start with AGENTS.md.

Tests that need the calibration files of a real unit are skipped without them. To run them, copy /rigol/data of your scope to local/cal-full and local/cal (the folder local/ stays out of git). OOS_CAL_DIR overrides this for most of them.

tools/plan-matrix.sh prints the register sequences of a fixed set of acquisitions without touching the hardware. Run it with two builds and compare the output to prove that a change leaves the analog path alone.

The test every_menu_fits walks all menus and fails on text wider than its control or a dialog off the screen. OOS_GALLERY=<dir> cargo test gallery -- --ignored in ui/ writes every screen as a picture.

tools/gel-sim.sh runs the USB install on a file laid out like a stock card.

tools/usb-sim.sh tests the handling of USB sticks in a virtual machine, with disks that get pulled.

tools/wlan-sim.sh tests the WLAN path on simulated radios in a virtual machine, without a stick. It needs Docker, qemu-system-aarch64 and one finished image build.

Start with the hardware overview and docs/architecture.md.

Licences

OOS is free software under the GNU General Public License, version 2 or (at your option) any later version. See LICENSE.

Third-party parts keep their own licences. THIRD-PARTY-LICENSES.md lists every one of them with its version, its licence, where its licence text is and which source files go with a release: the Linux kernel and the XDMA driver, BusyBox, glibc and GCC's runtime, Mesa, libdrm and zlib (the GPU helper, gpu/README.md), e2fsck, kexec, wpa_supplicant with libnl, nftables with libmnl and libnftnl, Dropbear, OpenSSH's sftp-server, musl, the Rust standard library, the Roboto font, the wireless regulatory database and the RTL8188EU firmware. An image built from this tree carries the licence texts and that list under /etc/licenses.

Every release carries the source archives of the binaries in its image next to the image. If you pass on an OOS image, the GPL requires you to provide the corresponding source as well: pass those archives and this tree at the release's tag on with it, or point to the release.

About

No description, website, or topics provided.

Resources

Contributing

Security policy

Stars

84 stars

Watchers

3 watching

Forks

Releases

Packages

Contributors

Languages