A PLC ladder logic simulation of an automatic box sorting system built using CodeSys. The system runs a conveyor to detect boxes, uses a pneumatic cylinder to push detected boxes off the line, counts processed boxes, and includes full Emergency Stop fault handling.
📌 Project Overview
Field
Details
Platform
CodeSys (Simulation)
Language
Ladder Diagram (LD)
Function
Detects boxes on conveyor and sorts them using a pneumatic cylinder
Counting
Tracks sorted boxes using CTU counter
Safety
Emergency Stop with Fault Lamp and latched fault handling
🔌 I/O Table
Inputs
Variable
Type
Description
START
BOOL
Start button — initiates the conveyor
STOP
BOOL
Stop button — halts the system
E_STOP
BOOL
Emergency stop — triggers fault condition
BOX_SENSOR
BOOL
Detects a box on the conveyor
F_LIMIT
BOOL
Forward limit switch — stops cylinder extension
B_LIMIT
BOOL
Backward limit switch — stops cylinder retraction
RESET_FAULT
BOOL
Resets the fault lamp after E_STOP condition
RESET_CTR
BOOL
Resets the box counter
Outputs
Variable
Type
Description
CONVEYOR
BOOL
Conveyor motor
FAULT_LAMP
BOOL
Indicates fault condition (set by E_STOP)
Cylinder_Extend
BOOL
Extends the pneumatic cylinder to push the box
Cylinder_Retract
BOOL
Retracts the cylinder back to home position
STOP_REQUEST
BOOL
Internal flag — requests conveyor stop when box detected
COUNT_REQUEST
BOOL
Internal flag — triggers box counter
Timers & Counters
Block
Type
Setting
Description
CTU_0
CTU
PRESENT_VALUE := 10
Counts sorted boxes, preset to 10
CURRENT_VALUE
WORD
—
Current box count
R_TRIG_0
R_TRIG
—
Rising edge trigger — fires once when cylinder reaches back limit
🔄 System Sequence
START pressed → CONVEYOR turns ON
BOX_SENSOR detects a box → STOP_REQUEST set → conveyor stops, cylinder begins extending
Cylinder extends until F_LIMIT is reached → Cylinder_Extend resets, Cylinder_Retract sets
Cylinder retracts until B_LIMIT is reached → Cylinder_Retract resets
On reaching B_LIMIT, rising edge trigger fires → COUNT_REQUEST set
CTU_0 increments the box count
Cycle repeats for the next box
Emergency Stop Sequence
E_STOP pressed → FAULT_LAMP set
Cylinder_Extend and Cylinder_Retract both reset — cylinder halts immediately
Conveyor stops (FAULT_LAMP blocks conveyor rung)
RESET_FAULT pressed → FAULT_LAMP resets → system ready to restart
🧩 Ladder Logic — Rung Breakdown
Rung
Description
1
START with seal-in (CONVEYOR + COUNT_REQUEST) energizes CONVEYOR. STOP_REQUEST, STOP, E_STOP and FAULT_LAMP all break the circuit
2
E_STOP sets FAULT_LAMP and resets both Cylinder_Extend and Cylinder_Retract — immediate safe stop
3
BOX_SENSOR sets STOP_REQUEST and sets Cylinder_Extend — begins push sequence
4
F_LIMIT resets Cylinder_Extend and sets Cylinder_Retract — cylinder reverses direction
5
B_LIMIT resets Cylinder_Retract. Rising edge on B_LIMIT triggers COUNT_REQUEST
6
COUNT_REQUEST increments CTU_0. RESET_CTR clears the counter
7
RESET_FAULT resets FAULT_LAMP, clearing the fault condition
🖥️ Visualization
A simple HMI was built in CodeSys with manual test buttons for START, STOP, E_STOP, FAULT RESET, CTR RESET, and simulated sensor inputs (F_LIMIT, B_SENSOR, B_LIMIT) along with three status indicator lamps.