amphour

A monitor for DC power-system gear. It reads Renogy charge controllers over Bluetooth (BT-1 / BT-TH, Modbus RTU over a BLE characteristic, via bleak) and Victron devices over VE.Direct (SmartShunt, SmartSolar MPPT, and anything else with a VE.Direct port), and Mopeka propane tank pucks over BLE advertisements, decodes them, and exports the readings to Prometheus and optionally InfluxDB.

It is a modern, maintained replacement for the ageing solar-bt-monitor / renogy-bt lineage, which is built on the unmaintained gatt Python library — amphour talks BLE through bleak instead. See Why this exists for the specific bugs it fixes.

Runs on Python 3.11+. No vendored libraries, no dead dependencies. Currently running in production against a Victron SmartShunt and a Renogy BT-TH.

Drivers

driver speaks to how
renogy_bt1 Renogy BT-1 / BT-TH module fronting a Renogy charge controller Modbus RTU over a BLE characteristic (via bleak), polled
victron_vedirect Victron SmartShunt, SmartSolar MPPT, and anything else with a VE.Direct port plain-text serial, streamed
mopeka_ble Mopeka Pro Check tank-level puck (propane) BLE advertisements, listened for — never connected to

Drivers are in-repo and chosen by name in config. There is deliberately no entry-point discovery or dynamic third-party loading: that machinery earns its keep when strangers write drivers you do not control, and costs complexity for nothing when every driver lives in this tree.

Each device runs as its own task, so one failing and retrying never stalls another — a BLE module that has wandered off must not hold up a serial shunt that is working perfectly.

Listening, not connecting

The Mopeka driver never opens a BLE connection. The puck broadcasts its reading in the advertisement itself, so amphour only listens — which means it cannot lock the device out, and staleness shows up directly as silence.

That also means every Mopeka puck in radio range is talking at once, under one manufacturer id. address is a filter, not a convenience. A puck retired with a dead ultrasonic transducer keeps advertising a perfectly well formed reading of zero, and may well be louder at the collector than the tank you care about. Matching on manufacturer id alone would quietly monitor the wrong tank.

A reading whose signal quality is below min_quality publishes no level at all — not a zero, not a NaN. Temperature, battery and quality keep publishing, so a puck that cannot see the liquid surface stays visibly alive rather than drawing an empty tank. (NaN in particular is load-bearing: InfluxDB rejects a NaN point, and a rejected point can sit in a write buffer and poison later writes.)

One more thing that is invisible from the code: a puck this collector cannot hear is not a puck that has moved on. Where two collectors each cover pucks the other cannot reach, that is radio geography, and the split is deliberate rather than a migration half-finished. If you find one, look for the note explaining it before tidying it away.

One vocabulary across drivers

Two drivers reporting the same physical quantity use the same field name, and every metric carries a device label. So they land on one metric with two label values:

amphour_battery_state_of_charge{device="renogy"}      9.0
amphour_battery_state_of_charge{device="smartshunt"} 99.7
amphour_battery_voltage{device="renogy"}             11.4
amphour_battery_voltage{device="smartshunt"}         11.128

That is real output from this repo's fixtures, and it is the point of the convention. Two independent measurements of one battery disagreeing by ninety points is a thing you want to see in one query — not something split across two metric names that never meet. The voltages agreeing to within 0.27 V in the same breath cross-validates both readings.

The convention cuts the other way too. A shunt's battery_current is net current into and out of the bank, signed; a charge controller's battery_charging_current is only what that controller is delivering. Same units, different quantities, so deliberately different names.


Why this exists

It replaces a working but ageing script built on gatt (unmaintained upstream), libscrc, a vendored logging module and gpiozero pulled in to read one temperature. That stack pinned its host to Python 3.9, and Python 3.9 pinned the host to an obsolete OS.

Three behaviours changed on purpose, because they were wrong rather than merely old:

A truncated frame is an error, not a reading of zero. The predecessor's integer reader returned 0 when asked to read past the end of a short buffer, so a partial frame produced a complete-looking set of zeros. amphour raises.

The device's checksum is actually checked. Every frame carries a CRC16/MODBUS. The predecessor computed one for outbound requests and never verified the inbound one, so a corrupted frame was parsed as truth.

The wait moved out of the callback. The predecessor called time.sleep(30) inside the BLE notification handler, blocking the gatt library's event loop for the whole interval. Here the interval is an await in the poll loop and the callback only hands over bytes.


Install

python3 -m venv /opt/amphour
/opt/amphour/bin/pip install git+https://github.com/nickodimus/amphour
sudo install -d /etc/amphour
sudo install -m 640 config.example.toml /etc/amphour/config.toml
sudoedit /etc/amphour/config.toml

Then the service:

sudo install -m 644 amphour.service /etc/systemd/system/
sudo systemctl daemon-reload
sudo systemctl enable --now amphour

BLE access goes through BlueZ over D-Bus, so the service needs no elevated privileges. It requires BlueZ 5.55 or newer (bleak's own floor).

Use

amphour                              # run against /etc/amphour/config.toml
amphour --config ./config.toml       # somewhere else
amphour --once                       # one reading from each device, then exit
amphour --list-drivers               # what drivers exist
amphour --list-fields renogy_bt1     # a driver's fields and confidence levels
amphour --decode ff0344...           # decode a captured Renogy frame offline

--once is the commissioning check: it proves every configured device is reachable and decoding before anything is installed as a service. It works for polling and streaming drivers alike — each device runs normally and is stopped as soon as it has produced one reading.

Configuration

See config.example.toml. The essentials:

[[device]]                       # note the DOUBLE brackets
name = "smartshunt"              # becomes the `device` label; must be unique
driver = "victron_vedirect"
port = "/dev/ttyUSB0"

[[device]]
name = "renogy"
driver = "renogy_bt1"
address = "AA:BB:CC:DD:EE:FF"

[prometheus]
enabled = true
port = 5000

[influxdb]
enabled = false

Prometheus is on by default; InfluxDB writes nothing and opens no connection unless enabled. Credentials may be supplied by AMPHOUR_INFLUX_USERNAME and AMPHOUR_INFLUX_PASSWORD instead of being written into the file, and the environment wins when both are present.

An unrecognised option is an error rather than a silently ignored default — a typo that gets dropped is how a setting appears to be applied without being applied.

Migrating from solar-bt-monitor

Set metric_prefix = "solarmon_" and existing dashboards keep working through the cutover. Field names differ (battery_percentage became battery_state_of_charge, max_charging_power_today became charging_power_max_today), so a dashboard referencing those needs updating; amphour --list-fields prints the current set.


The Renogy register map, and how much of it to trust

The device answers a single Modbus read of 34 holding registers from 0x0100. This map was reverse engineered, so every field records how well established it is:

confidence meaning
confirmed decoded from a real captured frame and cross-checked against the value the previous implementation independently reported for the same instant
probable not independently cross-checked, but triangulates against a confirmed field in a physically coherent way
unverified consistent with the published Renogy layout and with the captured bytes, but nothing yet rules out another reading

18 fields are confirmed, 2 probable, 11 unverified.

Only confirmed and probable fields are exported by default. Set include_unverified = true if you want the rest — but do not build an alarm on a hypothesis without checking it first.

Two captures anchor this so far: one at night with the array dark, one the next morning with it producing. The second one both promoted and demoted hypotheses, which is the point of recording confidence at all.

Promoted — 0x010B/0x010C, today's minimum and maximum battery voltage. Night showed 11.3 / 11.8 V bracketing a live 11.5 V. The next morning the pair had reset to that day's own figures, 9.8 / 12.5 V, still bracketing the live reading. Resetting overnight is exactly what a daily min/max must do, and the bracket has held on every frame of both captures. Still probable rather than confirmed, because confirmed here means cross-checked against another implementation's output and the predecessor never reported these fields.

Demoted — 0x010D, which the night capture made look like today's peak charging current. 802 W of confirmed peak charging power divided by 56.53 A gave 14.19 V, a textbook absorption voltage. It was a real relationship producing a correctly-shaped number, and it was wrong. The morning capture disconfirmed it three ways at once: the value did not reset overnight (5653 → 5616) while charging_power_max_today plainly did (802 → 691 W); a "peak today" of 56.16 A is inconsistent with the 22.76 A actually observed that morning; and the voltage ratio stopped landing anywhere sensible (12.30 V). It is now an unnamed raw register, with that history recorded in its help text so nobody re-derives the same wrong answer.

0x0121 sits immediately after the charging-state register, and the obvious guess was fault/alarm bits. Across 30 frames it instead tracks charging state exactly — state 04 on 11 of 11 frames, state 21 on 19 of 19, no exceptions. That is a companion status word, not an independent fault register. Only two charging states have been observed, so this is suggestive rather than settled. Exported raw, deliberately not decoded into named faults.

Testing

pip install -e ".[dev]"
pytest

The suite needs no hardware. It runs against real frames captured off the air from a live BT-TH module.

Each fixture entry holds two things that come from different programs:

  • frame_hex — the raw bytes the device put on the air, from a btmon capture
  • old_app_log — what the previous implementation reported for that same instant, read straight out of its own log file

tools/extract_fixtures.py builds these and deliberately does not decode anything, so the fixture cannot end up carrying the extractor's opinion of what the bytes mean. The test decodes frame_hex and asserts it matches old_app_log. Because the two sides come from different programs, that is a real cross-check rather than a decoder agreeing with itself.

tests/conftest.py refuses to load a fixture that is not in this format, so a future well-meaning change to the extractor cannot quietly make the comparison circular again.

The poll loop is tested too, through a replay transport that can be scripted to fail — connection failures, mid-run dropouts, corrupt frames, exploding sinks.

What the fixtures do and do not cover

Everything is captured from live hardware. Nothing is synthesised.

fixture contents conditions
night-2026-09-09 11 Renogy frames array dark; every PV, load and discharge field a legitimate zero
day-2026-09-09 19 Renogy frames overcast with variable cloud, array producing 180–270 W, charging in mppt
vedirect-smartshunt-2026-09-09 12 VE.Direct blocks a live SmartShunt 500A/50mV, both block types
vedirect-corrupt-sample one corrupt fragment from a genuinely corrupt region of the same capture

The Renogy fixtures give 540 field comparisons against the previous implementation, with no mismatches. The VE.Direct field meanings were each cross-checked against the description and units an independent implementation recorded for the same labels on the same physical device.

The daylight capture closed the gap that mattered: PV voltage, PV current, PV power, battery charging current and a non-zero charging_state were all structurally zero at night and so completely unexercised. test_reading.py asserts that coverage explicitly, so losing or replacing the daylight fixture with dark data fails the suite rather than quietly halving what it tests.

Still not covered by the automated suite, and honestly:

  • The tests never touch a live transport — production now does. The protocol layers are exercised against real captured bytes; the serial and BLE transports are not covered by the suite. In the field, though, both drivers now read live hardware continuously — a Victron SmartShunt over serial and a Renogy BT-TH over BLE, feeding Prometheus and InfluxDB. The BLE connect needed a retry loop to ride out BlueZ returning HCI 0x3e ("connection failed to be established") when the module's narrow advertising window is missed — common on a Raspberry Pi's built-in Bluetooth radio.
  • The top of the range. The daylight capture was taken under overcast, not at peak output. Scaling is linear and the largest raw value in play is nowhere near a u16 ceiling, so this is not a correctness risk — but nothing here has seen a bright day.
  • Everything load-side. load_voltage, load_current, load_power and every discharge counter read zero in both Renogy captures, because that controller has nothing wired to its load terminals.
  • Sub-zero temperatures. The sign-bit convention is implemented from documentation; no capture has been below freezing.
  • The VE.Direct capture is a SmartShunt only. An MPPT controller emits a different label set over the identical protocol; those labels are declared but have not been seen on the wire here.

Licence

MIT.