Skip to content
bigbadoooffPublic

About

A Home Assistant integration for Stiebel Eltron LWZ / Tecalor THZ heat pumps.

Topics

Resources

Contributing

Stars

19 stars

Watchers

2 watching

Forks

Repository files navigation

Stiebel Eltron LWZ / Tecalor THZ Integration (unofficial)

Validate GitHub Release License: GPL v3 Ruff Checked with mypy

GitHub last commit GitHub issues GitHub contributors GitHub Repo stars

Open your Home Assistant instance and open this repository inside the Home Assistant Community Store. Open your Home Assistant instance and start setting up this integration.

Version 0.7.1 — See CHANGELOG.md for the full list of new features and breaking changes in this release.

Introduction

This is a custom Home Assistant integration for connecting Stiebel Eltron LWZ or Tecalor THZ heat pumps to Home Assistant. The integration enables comprehensive monitoring and control of your heat pump system directly from your Home Assistant instance.

The integration communicates with the heat pump using the serial protocol, supporting both direct USB connections and network-based serial connections (via ser2net). This allows flexible deployment options depending on your home automation setup.

Parts of this software have been developed by the help of AI.

Origin: This integration is based on the FHEM-Module developed by Immi, adapted for Home Assistant with modern async architecture and full UI configuration support.

Features

Currently Implemented

  • ✅ Full UI Configuration: Easy setup through Home Assistant's integration interface — no YAML configuration required
  • ✅ Connection Options: Support for both USB serial and network (ser2net) connections
  • ✅ Sensor Platform: Monitor temperatures, pressures, operating states, runtime hours, and more
  • ✅ Binary Sensor Platform: Status flags such as compressor, pumps, valves and filter alarms
  • ✅ Switch Platform: Control heat pump functions on/off
  • ✅ Number Platform: Adjust numeric settings and parameters
  • ✅ Select Platform: Choose between predefined options — including passive cooling mode (firmware 4.39/5.39)
  • ✅ Time Platform: Set time-based parameters, schedules and programmes
  • ✅ Button Platform: One-shot commands, e.g. resetting the error list (depending on the firmware)
  • ✅ Climate Platform: Climate entities for Heating Circuit 1 and Heating Circuit 2 — with temperature control, HVAC mode and preset support
  • ✅ Water Heater Platform: Hot water as a water heater entity — temperature, setpoint and eco (setback) / performance / off state
  • ✅ Fan Platform: Ventilation as a fan entity — shows the current stage and starts unscheduled ventilation at stage 0–3
  • ✅ Event Platform: Events for a new fault and a requested filter change
  • ✅ Repairs: A drifted heat pump clock raises a fixable repair issue
  • ✅ Diagnostics: Download a diagnostics report for troubleshooting (via Settings → Devices & Services)
  • ✅ Device Registry Integration: Proper device identification in Home Assistant
  • ✅ Per-Block Polling Intervals: Each register block has its own configurable poll interval
  • ✅ Smart Entity Management: Non-essential entities are hidden by default to reduce clutter
  • ✅ Services: thz.read_raw_register, thz.refresh_block, thz.set_diverter_valve, parameter backup/restore (thz.backup_parameters, thz.restore_parameters, thz.list_parameter_backups), and fault memory (thz.probe_fault_memory, thz.acknowledge_faults, thz.clear_fault_memory)

Climate Entities

These entities are created when the required data blocks and parameters are available:

Entity Source Supports
Heating Circuit 1 (climate) pxxF4 Temperature setpoint, HVAC mode (heat, or cool with cooling support: follows the cooling switch, and in cool mode the temperature is the cooling setpoint), preset (operating mode); a circuit in standby shows the action off
Heating Circuit 2 (climate) pxxF5 Temperature setpoint, HVAC mode, preset — created only when HC2 is configured
Hot Water (water heater) pxxF3 Temperature and setpoint in effect; state performance (day), eco (setback, night setpoint) or off (standby). Setting a temperature writes the day setpoint (p04), the night setpoint (p05) while in eco, or the manual setpoint (p11) when that one is in effect.
Ventilation (fan) p99startUnschedVent (4.x/5.x), pxxF6/pxxEE (2.x) The time programs set the ventilation stage; the fan controls unscheduled ventilation. A speed of 33/66/100 % starts it at stage 1/2/3, off starts it at stage 0, each for the time set in p43–p46; then the program takes over again. The program's stage settings (p07 etc.) are not changed. Shown is the stage the ventilation runs at, also as the stage attribute: from the supply airflow of the current stage (pxxE8, when polled) compared with p37–p39, otherwise from today's fan time program (day stage p07 inside a window, night stage p08 outside). On 2.x firmware, which has no command to start ventilation, the fan only shows the stage (from the polled blocks pxxF6 and pxxEE): the one set at the device while its time runs, otherwise the stage of the fan program state (day, night or standby). The fan reads its registers through the same parameter poller as the other settings, so it adds no extra requests for registers that are polled anyway.

HC1 also exposes HVAC action (heating / cooling / idle / off) and optional cooling mode when the device supports active cooling. The HVAC mode is what is selected (the cooling switch); the action shows whether the heat pump is cooling right now.

Services

thz.read_raw_register

Read any raw register block directly from the heat pump and return the hex dump. Useful for firmware research and debugging. Accepts the same block name forms as thz.refresh_block. See docs/read-raw-register-service.md for full documentation.

thz.refresh_block

Force an immediate re-read of a specific coordinator block without waiting for the next poll interval. Accepts any block name form ("FB", "pxxFB", "0xFB"). Returns {success, block}.

service: thz.refresh_block
data:
  block: "FB"

thz.set_diverter_valve

Manual control of the 3-way diverter valve motor. Both heating and dhw directions are guarded by the diverterValve status bit in pxxF2, read from the heat pump right before the move — the command is refused if the heat pump is currently pressurising the opposite circuit, or if pxxF2 cannot be read. After 3 seconds the motor is automatically stopped and the stop is verified by reading back both motor registers.

service: thz.set_diverter_valve
data:
  position: "dhw"   # heating | dhw | off

⚠️ Only use this service if you have a manually-controlled 3-way valve and understand the risk of incorrect actuation.

Fault Memory (firmware 4.x / 5.x)

The heat pump keeps its last ten faults but has no "acknowledged" concept. When the Fault Log (pxxD1) block is polled, four sensors are created from it (no extra serial traffic):

Sensor Meaning
Fault status No fault / Fault — Fault while there are records you have not acknowledged
Fault memory Number of stored records; all records (newest first) are in the entries attribute
Latest fault The newest stored fault, translated (none if there is none) with code, date and time as attributes
New faults Number of records not yet acknowledged; the records are in the entries attribute

Faults already stored when the integration first sees the block are treated as acknowledged, so an existing history does not trigger an alarm. The heat pump stores day and month only, no year.

thz.probe_fault_memory

Read-only. Returns the raw D1 bytes and the decoded records.

thz.acknowledge_faults

Marks all records currently stored as seen. Only affects Home Assistant (the Fault status and New faults sensors); nothing is written to the heat pump.

thz.clear_fault_memory

Physically clears the heat pump's fault memory. It reads and validates D1 first, sends one clear command (0000 to D1, never retried) and verifies the result by reading D1 again. The history on the device is lost. You must pass confirmation: "CLEAR D1". It works on every firmware that provides D1, but the write has only been verified on real hardware on firmware 4.19; if the readback still shows faults the service reports an error.

service: thz.clear_fault_memory
data:
  confirmation: "CLEAR D1"

Hidden Entities by Default

To provide a cleaner initial setup experience, the following entity types are hidden by default:

  • Time plan/programme entities: Advanced schedule configuration entities (programDHW_*, programHC1_*)
  • Advanced technical parameters: Parameters like gradient, hysteresis, integral components (typically p13 and higher)
  • HC2 (Heating Circuit 2) entities: Only needed if you have a second heating circuit installed, including HC2's own schedule entities (programHC2_*). Gated separately from the two categories above (see below).

Two independent settings control this, both asked during setup and changeable later via Settings → Devices & Services → THZ → Configure. Changing either retroactively bulk enables/disables the matching entities already in the registry, not just newly-created ones — any entity you've individually re-enabled or disabled by hand is left alone.

  • Entity visibility — a three-way tier covering schedules and advanced parameters:
    • Default: hide both.
    • Extended: enable advanced parameters, keep schedules hidden.
    • All: enable both.
  • Enable HC2 entities — a separate checkbox, off by default. Independent of the tier above — even the "All" tier leaves HC2 hidden until this is checked, since most installs only have one heating circuit.

Entities can also always be re-enabled individually via Settings → Devices & Services → THZ → device → Show disabled entities.

Sub-devices

The entities can be grouped into sub-devices linked to the heat pump:

  • Heating circuit 1
  • Heating circuit 2
  • Hot water
  • Ventilation
  • Compressor (compressor, refrigerant circuit, defrost, COP)
  • Solar
  • Cooling

General entities, such as the clock, fault memory, versions, outside temperature and operating mode, stay on the heat pump device. Each sub-device has its own device page and can be put in its own area.

The Split into sub-devices setting is asked during setup, on by default. It can be changed later via Settings → Devices & Services → THZ → Configure. Installations set up before this option existed keep the single device until you switch it on.

Switching the split on or off keeps the entity IDs, but the displayed names change. With the split on, a name is made of the sub-device name and the entity name, for example "lwz Hot water DHW temperature". Automations that refer to entity IDs keep working. Automations that pick a device (device triggers, conditions or actions) must be pointed to the new device. When the split is switched off, the entities move back to the heat pump with their names, areas and enabled state intact, and the sub-devices are removed.

COP (Coefficient of Performance) Sensors

For firmware versions that support energy monitoring (e.g., 4.39), the integration automatically provides COP sensors:

  • Current COP: Real-time COP based on instantaneous power measurements
  • Daily COP DHW / Heating / Total
  • Lifetime COP DHW / Heating / Total

The heat pump resets only the kWh part of its daily energy counters at midnight and keeps the Wh part. The integration subtracts that kept part, so the daily counters and the daily COP start at 0 each day. The correction starts with the first midnight after installation.

COP = Heat Output ÷ Electrical Input. A COP of 3.0 means 3 kW of heat for every 1 kW of electricity consumed.

Runtime Hours (firmware 4.39 / 5.39)

The sHistory block (command 09) provides cumulative operating hours for the compressor and booster heaters:

  • compressor_runtime_heating — compressor hours in heating mode
  • compressor_runtime_cooling — compressor hours in cooling mode
  • compressor_runtime_dhw — compressor hours in DHW mode
  • booster_runtime_dhw — booster heater hours for DHW
  • booster_runtime_heating — booster heater hours for heating

Passive Cooling (firmware 4.39 / 5.39)

A Passive Cooling select entity controls the passive cooling mode:

Mode Description
off Passive cooling disabled
exhaust_air Cool via exhaust air only
supply_air Cool via supply air only
bypass Bypass mode
sommerkassette Summer cassette mode

Diagnostics

The integration supports Home Assistant's built-in diagnostics download:

  1. Go to Settings → Devices & Services → THZ
  2. Click on your heat pump device
  3. Click Download Diagnostics

The report includes firmware version, connection status, coordinator last-update times, and redacted hex dumps of all currently-polled register blocks.

How Data Is Updated

The integration polls the heat pump over its serial protocol; the heat pump never pushes anything. Only one request is on the line at a time.

  • Read values (sensors, binary sensors, climate, water heater): each register block has its own coordinator and interval, 600 seconds by default, set per block under Reconfigure. A block is read in one request, and all entities of the block update together.
  • Settings (number, select, switch, time, fan, and the climate preset and cooling setpoint): one parameter poller per heat pump reads every setting once per write interval (3600 seconds by default), one after the other. A register shown by several entities is read once; disabled entities are not read. On 2.x firmware, settings inside a polled block take their value from that block.
  • After a change from Home Assistant the entity shows the written value at once, and the register (or, for a 2.x setting inside a polled block, its block) is read again right away, so every entity showing it follows.
  • Right now: homeassistant.update_entity reads a setting at once; thz.refresh_block re-reads a block.
  • Clock: compared with Home Assistant's time every 15 minutes (see Device Clock).

When the heat pump does not answer, the entities become unavailable and recover with the next successful read.

Events

See docs/automations.md for example automations.

Two event entities let automations react to things that happen once:

Entity Event types Fires when Attributes
Fault fault a new record appears in the fault memory (pxxD1, firmware 4.x/5.x) fault_number, fault_code, description, time, date
Filter change filter_both, filter_up, filter_down the heat pump starts asking for that filter change (pxx0A0176) —

They use data that is polled anyway, so the blocks must be selected for polling. The fault event remembers the records it has seen, so a fault stored while Home Assistant was not running fires once after the start. On the very first start the existing fault history fires nothing, and neither does a filter that is already due; the fault sensors and filter binary sensors show that state.

Device Clock

The heat pump's time programs run on its own clock. Every 15 minutes the integration compares it with Home Assistant's time. If it is off by more than a minute:

  • with Auto-sync clock on (Reconfigure), the clock is corrected;
  • otherwise a repair issue appears under Settings → System → Repairs. Fixing it sets the heat pump clock to Home Assistant's time, and can turn on automatic sync for the future. The issue goes away by itself once the clock is right again.

Compatibility

Supported Firmware Versions

Firmware Notes
2.06 Sensor read support; write support via block read-modify-write
2.14 / 2.14j Sensor read support; write support via block read-modify-write
4.19 4.39-like profile for the THZ 303 SOL; a few pxxFB sensors the shorter payload cannot supply are disabled. Fault memory clear verified on this firmware
4.39 Full support including energy sensors, COP, runtime hours, and passive cooling
5.09 / 7.09 4.39-based profile with the 5.09 extras (7.09 uses the 5.09 maps)
5.39 Full support including passive cooling energy sensor (sCoolHCTotal)
7.59 Uses the 5.39 maps
Other Falls back to a 4.39-like configuration (like the reference FHEM module) — may work partially

How Firmware Versions Are Loaded

The firmware the heat pump reports at setup (or a firmware override chosen at setup or under Reconfigure) selects which register map modules the integration merges together. This determines both which sensors/entities get created and how their raw bytes are decoded — picking the wrong firmware typically produces missing entities or garbled values, not errors.

Everything is driven by RegisterMapManager / RegisterMapManagerWrite (custom_components/thz/register_maps/register_map_manager.py), which build a merged map for a given firmware string in three layers, applied in order (a later layer's entries win, matched by sensor name within the same register block):

  1. Base map — register_map_all.py (reads) is always loaded first. It defines the registers common to essentially every firmware (climate blocks F2–F5, sGlobal/FB, sTimedate/FC, firmware/hardware version FD/FE, etc.), using the 4.39/5.39 byte layout. There is no write_map_all.py — the base write map is effectively empty.
  2. Write maps — one or more write_map_*.py modules for the firmware, merged in listed order.
  3. Read maps — one or more readings_map_*.py / register_map_*.py modules for the firmware, merged in listed order over the base map.
firmware value Write maps Read maps (over the base)
206 write_map_206 readings_map_2xx, readings_map_206, register_map_206
214 write_map_206, write_map_214 readings_map_2xx, readings_map_214, register_map_214
214j write_map_206, write_map_214 readings_map_2xx, readings_map_214j, register_map_214j
419 write_map_439_539, write_map_439 readings_map_439, register_map_419
439 write_map_439_539, write_map_439 readings_map_439, register_map_439
439technician write_map_439_539, write_map_439, write_map_X39tech readings_map_439, register_map_439
509 / 709 write_map_439_539, write_map_539 readings_map_439, readings_map_509
539 / 759 write_map_439_539, write_map_539 readings_map_439, readings_map_539
539technician write_map_439_539, write_map_539, write_map_X39tech readings_map_439, readings_map_539
anything else write_map_439_539, write_map_439 readings_map_439 (default, treated as 4.39-like)

709 is intentionally identical to 509 — the 7.09 firmware has no register differences from 5.09 that this integration is aware of, and 759 likewise uses the 5.39 maps. An unrecognized firmware string falls back to default, which mirrors the reference FHEM module's own behaviour of assuming 4.39 rather than guessing at 5.39-like registers that may not exist on the device (e.g. cooling-only blocks).

The 2xx family (206 / 214 / 214j)

  • readings_map_2xx.py holds the sensor blocks the legacy FHEM module requests identically for all three 2.xx variants (defrost/heating/DHW/ solar parameters, operating hours, schedules, fan calibration, solar circuit, system status, time/date). readings_map_206.py, readings_map_214.py, and readings_map_214j.py then only need to add what genuinely differs per variant:
    • pFan (cmd 01): 206 uses a longer byte layout than 214/214j, which share a shorter one.
    • sHC1 (cmd F4) and sGlobal (cmd FB): each variant has its own bit layout, since the underlying hardware/firmware differ.
    • The fault log sLast10errors (cmd D1) only exists on 206 — 214/214j firmware doesn't expose it, so no entity is created for those variants.
  • Writing a parameter on 2xx firmware works differently from 4.39/5.39: the protocol has no per-register write command, so RegisterMapManagerWrite cross-references the read register maps to look up each writable parameter's containing block, byte offset, and length, then performs a read-modify-write of the whole block (write_mode="block", see _enrich_2xx_write_entries). 4.39/5.39 write registers directly.
  • No energy/COP metering, runtime-hours-by-mode, or passive cooling exists on 2xx firmware — those registers were only added starting with 4.39 (see below).

The 4.39 / 5.39 family (439 / 509 / 709 / 539 / 759)

  • readings_map_439.py is the common base for this family (energy/COP sensors, compressor & booster runtime hours, fault log, solar circuit, fan speeds); readings_map_509.py / readings_map_539.py layer firmware-specific extras on top (e.g. flow rate, humidity thresholds, compressor power/rotation limits, dew point sensors, and — 5.39 only — the passive-cooling energy sensor sCoolHCTotal).
  • Devices without active cooling hardware get cooling-only registers stripped from the merged 5.39 maps (_COOLING_READ_BLOCKS / _COOLING_WRITE_KEYS, applied via the has_cooling flag from your config), so the passive cooling select entity and its related sensors only appear when relevant.
  • The 439technician / 539technician variants add write_map_X39tech on top of the normal 439/539 write maps, exposing extra technician-only parameters that are otherwise not writable.

Confirmed Working Devices

Model Firmware Version Status
LWZ5 7.59 ✅ Working

Note: While this integration has been confirmed to work with the devices listed above, it may work with other Stiebel Eltron LWZ and Tecalor THZ models. Users are encouraged to test and report compatibility.

Installation

Prerequisites

  • A current Home Assistant release (tested with 2026.2; releases before 2024.11 are not supported)
  • USB-to-serial adapter or ser2net server for network connection
  • Physical access to your heat pump's serial interface

Option 1: HACS (Recommended)

  1. Ensure HACS is installed in your Home Assistant instance
  2. Open HACS → Integrations → three-dot menu → Custom repositories
  3. Add https://github.com/bigbadoooff/thz as a custom repository with category Integration
  4. Search for "Stiebel Eltron LWZ / Tecalor THZ" and click Download
  5. Restart Home Assistant

Option 2: Manual Installation

  1. Download the latest release from the releases page
  2. Copy the thz folder to <config_dir>/custom_components/thz/
  3. Restart Home Assistant

Configuration

  1. Go to Settings → Devices & Services → + ADD INTEGRATION
  2. Search for "Stiebel Eltron LWZ / Tecalor THZ Integration"
  3. Choose your connection type (USB or Network/ser2net) and follow the wizard

Removal

  1. Go to Settings → Devices & Services → THZ
  2. Click the three-dot menu on the integration entry and choose Delete
  3. Confirm the removal — this stops all polling and removes the device and its entities from Home Assistant. The thz.* services stay registered until Home Assistant restarts without the integration.

After deleting the integration in the UI, also remove the files depending on how it was installed:

  • HACS: open HACS → Integrations, find "Stiebel Eltron LWZ / Tecalor THZ", and click Remove
  • Manual installation: delete the <config_dir>/custom_components/thz/ folder

Then restart Home Assistant. No credentials or external accounts are created by this integration, so there is nothing else to revoke — only the local serial/network connection to the heat pump is released.

Known Limitations

  • One client per serial line. The heat pump's interface serves one program at a time. FHEM or another tool on the same USB port or ser2net connection disturbs the communication.
  • No discovery. USB and ser2net connections are set up by hand.
  • Settings update slowly. A change made at the heat pump's control panel shows up after the next write interval (1 hour by default), unless you refresh the entity (see How Data Is Updated).
  • Firmware coverage. The register maps cover 2.06, 2.14, 2.14j, 4.19, 4.39, 5.09, 5.39, 7.09 and 7.59. Any other firmware uses the 4.39 maps; some values may then be missing or wrong. A firmware override is available under Reconfigure.
  • 2.x firmware: no fault memory sensors or fault events (different pxxD1 layout), and the ventilation can only be shown, not started.
  • Cooling: passive cooling exists on 4.39 and 5.39; active cooling only on 5.x devices whose cooling hardware answers at setup.
  • Hot water mode follows the heat pump's time program and operating mode; the water heater sets the temperature, not the mode.
  • Energy values and COP need firmware 4.39 or newer.

Troubleshooting

USB connection stops working after host reboot

If you are using USB and another application (e.g., FHEM) also accesses the serial port, it may grab the device before Home Assistant on startup, causing "Handshake 1 failed" errors. Disable the THZ device in FHEM (or whichever application is competing) and restart the Home Assistant container.

If HA is running in Docker and the device was not enumerated when the container started, restart the container after the USB adapter appears: docker restart homeassistant.

Integration does not create entities

Check HA logs for thz entries. Common causes:

  • Firmware version not detected (empty firmware string) — the integration falls back to a default map but some blocks may be empty
  • Block not supported on the device — blocks returning no data are skipped silently

Use thz.read_raw_register to verify that a specific block returns data on your device.

Logging

In normal operation the integration logs one line at startup ("Connected to the heat pump") and otherwise only what needs attention:

  • a lost connection once as a warning, and once as info when it is back (the blocks that fail meanwhile are not logged one by one);
  • a single setting that cannot be read while the heat pump answers, once as a warning, and once as info when it reads again;
  • a sensor whose data is too short or cannot be decoded, and an unknown select value, once until it reads correctly again;
  • a drifted device clock once, when its repair issue is raised (see Device Clock).

For troubleshooting, turn on Enable debug logging on the integration's page, or set the level in configuration.yaml, for example:

logger:
  logs:
    custom_components.thz: debug              # everything
    custom_components.thz.thz_device: debug   # only the serial/TCP exchange

Disclaimer

IMPORTANT: This is an unofficial, community-developed integration and is not affiliated with, endorsed by, or supported by Stiebel Eltron or Tecalor.

⚠️ Use at Your Own Risk: While this integration has been tested and used in production, no warranty is provided. Improper use could affect your heat pump's operation. Always monitor your heat pump after installing this integration.

How to Contribute

Contributions are welcome!

  • Bugs: Open an issue with HA version, heat pump model, firmware version, and relevant log entries
  • Compatibility reports: Let us know which devices work (or don't)
  • Code: see CONTRIBUTING.md and ARCHITECTURE.md

Contributors

Thanks to everyone who has helped build and improve this integration:

bigbadoooff
bigbadoooff
Largelos
Largelos
MartinDomig
MartinDomig

See the full contributor graph for everyone who has opened issues, filed compatibility reports, or submitted PRs. Parts of this software have also been developed with the help of AI (GitHub Copilot, Claude).

License

GNU General Public License v3.0 — see LICENSE for details.


Credits: Based on the FHEM-Module by Immi. Thanks to the FHEM and Home Assistant community for their support and contributions.

About

A Home Assistant integration for Stiebel Eltron LWZ / Tecalor THZ heat pumps.

Topics

Resources

Contributing

Stars

19 stars

Watchers

2 watching

Forks

Releases

Packages

Contributors

Languages