SolarMax connects Home Assistant directly to a SolarMax inverter over the MaxComm TCP protocol on your local network. It reads production, energy totals, operating status, alarms, and diagnostic measurements without a cloud account.

At a glance

  • Local, read-only communication with no cloud account
  • Optional night values for dashboards and energy statistics
  • One persistent inverter connection with automatic recovery
  • Faster checks after daytime failures and quiet polling overnight
  • Clear states for normal shutdowns and unexpected connection faults
  • Optional inverter group with automatic sum entities across every inverter
  • Native reconfiguration and repair flows in Home Assistant
  • English, German, and French translations

Before you install

You need:

  • Home Assistant 2024.12.0 or newer
  • A SolarMax inverter that exposes the MaxComm protocol over TCP
  • Network access from Home Assistant to the inverter, normally on port 12345

Supported inverters

Compatibility Models or protocol
Confirmed by users SolarMax 7TP2, 4200S, 3000S, and 13MT3
Likely to work Other pre-2015 SolarMax inverters with MaxComm TCP support
Not supported Models that provide only Modbus, serial, or cloud access

Support is determined by the protocol, not only by the model name. Some inverters omit individual MaxComm fields. The integration still works, but the entities for those fields remain unavailable.

Important

A SolarMax inverter accepts only one TCP client at a time. Stop MaxTalk, vendor software, test scripts, or another Home Assistant instance before setting up the integration.

Give the inverter a fixed DHCP lease if possible, so its address does not change after setup.

Install

HACS

  1. Open HACS and select Integrations.
  2. Open the menu and select Custom repositories.
  3. Add https://github.com/ludgerbeckmann/ha_solarmax as an Integration repository.
  4. Search for SolarMax and install it.
  5. Restart Home Assistant.

HACS handles updates after the custom repository has been added.

Manual installation

  1. Download ha_solarmax.zip from the latest GitHub release.
  2. Create custom_components/ha_solarmax in the Home Assistant configuration directory and extract the archive there.
  3. Confirm that custom_components/ha_solarmax/manifest.json exists.
  4. Restart Home Assistant.

Set up and configure

After installation:

  1. Open Settings → Devices & services.
  2. Select Add integration.
  3. Search for SolarMax.
  4. Enter the inverter details and polling settings.

Home Assistant briefly connects to the inverter before saving the entry. After a successful check, the integration creates one device and its sensor entities.

Connection and polling settings

Setting Default Description
IP address (none) Inverter IP address or host name
Port 12345 MaxComm TCP port
Inverter address 1 MaxComm address from 1 to 249
Update interval 30 s Normal online interval from 5 to 3600 seconds
Device name Inverter Device name shown in Home Assistant
Verify response checksum On Reject responses with an invalid MaxComm checksum
Keep sensor values overnight On Apply the synthetic night policies described below
Twilight elevation threshold Sun elevation below which an offline inverter is expected

Change settings later

The integration menu offers two actions:

Action Use it for
Reconfigure IP address, port, inverter address, or device name
Configure Update interval, checksum verification, night values, or twilight threshold

Home Assistant tests a changed host, port, or inverter address before saving it, so the inverter must be reachable. It then reloads the integration and restores the previous connection if the new one cannot start. Entity IDs and unique IDs stay unchanged. Changing only the device name does not contact the inverter.

Options do not require a connection test. Home Assistant reloads the integration after saving them and restores the previous options if that reload fails.

Multiple inverters and the inverter group

Add one config entry per inverter, each with its own address (1-249). Several inverters can share one host and port when they sit behind the same MaxComm gateway; the integration serializes and shares that connection between them automatically.

To get combined totals across every inverter, select Add integration, choose SolarMax again, and pick Inverter group instead of adding another device. This creates one virtual device with a sum entity for every register where adding values across inverters is meaningful (power, current, energy, installed power, start count -- for example, a combined AC Power across all inverters). Voltages, frequencies, temperatures, and relative power are left out: they describe the grid or a single device rather than something that scales with fleet size, so summing them would produce a meaningless multiple rather than a real total. Only one group can exist. By default every configured inverter counts, and one added or removed later is picked up automatically without reconfiguring the group; use the group's own Configure (gear icon) to limit the sum to a specific selection of inverters instead. A register missing or unavailable on one included inverter is left out of that register's sum rather than making the whole sum unavailable; a sum entity itself is only unavailable when no included inverter currently reports that register at all.

Checksum verification

Leave Verify response checksum enabled unless your inverter is known to return valid MaxComm data with a non-standard checksum. If its logs repeatedly show checksum errors, turn the option off. The integration will then ignore the CRC value but will still reject malformed responses.

Connection, outages, and recovery

The integration owns one persistent TCP connection and reuses it across polls. It requests device information separately from live measurements, so a missing optional value does not discard an otherwise valid update.

Architecture in brief

  • The protocol layer builds and validates MaxComm frames, checks checksums when enabled, and converts raw register values to Home Assistant units.
  • SolarmaxLink owns the inverter's single TCP connection and serializes requests so two exchanges cannot overlap.
  • ConnectionEngine caches values, applies the 15-second poll budget and retry policy, and turns connection or protocol failures into an EngineSnapshot.
  • SolarmaxCoordinator schedules the next poll from that snapshot and supplies the resulting state to sensors, diagnostics, and repairs.

See the architecture guide for the full component and state model.

What the Status Code means

The Status Code entity shows the inverter's translated SYS state while it is online. If the inverter cannot be reached, it reports one of these integration states:

Home Assistant state Raw state Meaning
Unknown unknown No successful connection yet; daytime startup is still within its reconnect window
Offline (expected) offline_expected Darkness or inverter shutdown evidence explains the disconnect
Offline (fault) offline_fault The inverter failed during daytime without shutdown evidence

The normal online condition is represented by the live inverter status rather than a synthetic online value.

How Home Assistant classifies an outage

The integration uses the last valid inverter data together with Home Assistant's sun position:

  1. A successful poll arms an expected shutdown when SYS reports 20002 or DC power (PDC) falls below 25 W.
  2. The next disconnect is Offline (expected) when that evidence exists or the sun is below the configured twilight threshold.
  3. An unexplained daytime disconnect is Offline (fault).
  4. A shutdown that starts unusually early is allowed one hour and at least ten failed probes before it escalates to a fault.

At daytime startup, the integration keeps the state Unknown (unknown) during a 150-second reconnect window. This avoids raising a fault while the inverter or network is still becoming available.

Polling and recovery

Condition Poll interval
Online Configured update interval
Startup reconnect Configured interval or 60 seconds, whichever is shorter
Daytime fault Configured interval or 60 seconds, whichever is shorter
Expected offline during full night 15 minutes
Expected offline from civil dawn or during daytime 60 seconds

Expected-offline polling accelerates when the rising sun reaches -6°, before the configurable twilight threshold used to classify faults. This helps detect the inverter's return promptly without increasing traffic throughout the night. Each poll has a 15-second budget. A lost response or corrupt frame gets one retry within that budget. Reloading or unloading the integration closes the socket so the inverter does not retain the client slot.

If Home Assistant's sun.sun entity is unavailable, the integration logs one warning and uses the local clock: 20:00-06:00 for expected-offline classification, with faster recovery polling starting at 05:00. A diagnostic download reports sun.sun, clock_fallback, or unknown as the active sun source.

Connection repairs

After five minutes of a daytime fault, Home Assistant creates a repair issue. Open it to change the host or port and test the connection. A successful test saves the new connection, but the issue remains visible until the inverter completes a full online update. You can also use Home Assistant's Ignore action.

Automations and diagnostics

When relevant, the Status Code entity exposes:

Attribute Purpose
last_successful_update Time of the last valid inverter response
fault_since Start of the current unexplained fault
reconnecting Whether startup recovery is still in progress
expected_outside_twilight Whether shutdown evidence occurred above the twilight threshold
code and raw_value Raw status or offline details for diagnostics

Automations created with an older version must replace Offline (Night) (offline_night) with Offline (expected) (offline_expected), and Connection failed (connection_failed) with Offline (fault) (offline_fault). Automations match the raw values shown in parentheses.

Last Connection Fault

This entity records when the most recent unexpected daytime connection fault began, and keeps showing that time after the inverter recovers — a history/alerting signal for a dashboard or an automation such as "notify me if this changed in the last few minutes". It stays unknown until the first such fault. A brief reconnect right after a Home Assistant restart or update, and any disconnect the integration can already explain (shutdown evidence, or darkness below the twilight threshold), are never recorded here — only a fault classified as Offline (fault) updates it.

Sensor values at night

Many SolarMax inverters turn off their network interface when production ends. That is normal, but it leaves Home Assistant without a live value until the next successful poll.

New inverters are set up with this enabled by default. To change it:

  1. Open Settings → Devices & services.
  2. Find SolarMax and select Configure.
  3. Toggle Keep sensor values overnight and save.

With this option disabled, measurement entities become unavailable while the inverter is offline. When enabled, the integration applies a policy suited to each register:

Policy Sensors Value while expected offline
Zero PAC, PDC, PD01PD03, PRL, IDC, ID01ID03, IL1IL3, UDC, UD01UD03 0
Hold KMT, KYR, KT0, KHR, CAC, KLD, KLM, KLY, PIN, ULH, ULL, TNH, TNL, SAL Last successful value
Hold until midnight KDY Last value, then 0 after local midnight
Unavailable UL1UL3, TNF, TKK, TK2, TK3, and unlisted sensors Unavailable

Synthetic states include a night_value_source attribute such as zero, hold, or unavailable, so automations can distinguish them from live data.

An early disconnect above the twilight threshold is treated cautiously. Zero policy sensors stay unavailable until darkness because the integration cannot yet assume production has stopped. Hold policy sensors may retain their last value.

After a Home Assistant restart at night, a sensor remains unavailable until the integration has received that register at least once. This prevents an unsupported register from appearing as 0. Once observed, zero-policy sensors can report 0, and hold-policy sensors can retain their last value.

Available sensors

Entity names are translated in Home Assistant. The MaxComm register is shown in parentheses to make protocol logs and diagnostics easier to interpret.

Enabled by default

Entity Register Unit or value
AC power PAC W
DC power PDC W
Energy today KDY kWh
Energy this month KMT kWh
Energy this year KYR kWh
Total energy KT0 kWh
Energy yesterday KLD kWh
Energy last month KLM kWh
Energy last year KLY kWh
Relative power PRL %
Operating hours KHR h
Start count CAC count
Installed power PIN W
Inverter temperature TKK °C
Grid frequency TNF Hz
Alarm SAL Translated alarm state and active alarm details
Status Code SYS Translated inverter or connection state
Last Connection Fault — (synthetic) Timestamp; see Last Connection Fault

Optional diagnostic entities

Group Registers Unit
DC string power PD01PD03 W
AC phase voltage UL1UL3 V
DC and string voltage UDC, UD01UD03 V
AC phase current IL1IL3 A
DC and string current IDC, ID01ID03 A
Additional inverter temperature TK2, TK3 °C
Grid voltage limits ULH, ULL V
Grid frequency limits TNH, TNL Hz

Optional entities can be enabled from the SolarMax device page. An unavailable optional entity usually means the inverter does not return that register; it does not necessarily indicate a connection failure.

The Alarm entity exposes its numeric code and, for a bitmask containing multiple alarms, an active_alarms attribute. The Status Code entity also retains its raw code for diagnostics while displaying a translated state.

Troubleshooting and support

Symptom First check
Setup cannot connect Confirm the IP and port, then stop every other MaxComm client
Repeated checksum errors Verify the inverter response, then try the checksum checkbox for known non-standard firmware
Offline (fault) (offline_fault) during daylight Check power, Ethernet, IP address, and whether another client took the connection
Offline (expected) (offline_expected) at the wrong time Check Home Assistant's location, time zone, sun entity, and twilight threshold
Only some entities are unavailable The inverter may not implement those MaxComm registers
Held values are missing after a night restart Wait for the first successful daytime poll

The troubleshooting guide explains these checks, logging, connection states, and diagnostic downloads in more detail.

If the problem remains, use the matching GitHub issue form. Include the Home Assistant and integration versions, inverter model, connection state, relevant settings, diagnostics, and logs. Remove credentials or network details that you do not want to publish.

Contributing and development

CONTRIBUTING.md covers local setup, checks, translations, pull requests, and releases. docs/architecture.md describes the protocol, connection engine, coordinator, entities, and test emulator.

Run the same validation used by CI with:

script/check

Disclaimer

This is an independent, community-maintained project. It is not affiliated with, endorsed by, sponsored by, or supported by SolarMax or any related company, distributor, installer, or rights holder. Product and company names are trademarks of their respective owners.

Credits

This project started as a fork of oschick/solarmax-ha-integration by Ole Schicketanz.

License

This project is licensed under the MIT License.

About

Home Assistant integration for SolarMax inverters over the local MaxComm TCP protocol

Topics

Resources

Contributing

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages