An open-source, portable Ethernet diagnostic tool built for troubleshooting in the field.
Syndetis is a small ESP32-based project designed for network technicians, industrial automation engineers, and anyone troubleshooting wired network connections. It combines a wired network interface, a 128×64 OLED display, three buttons, and a local web dashboard in a prototype powered by a USB power bank.
The idea is simple: connect to a network port, check what is happening, and get useful information without having to reach for a laptop every time.
Current stable firmware: v0.7.0 | Previous stable firmware: v0.6.0 | Platform: WT32-ETH01 / ESP-IDF v6.1
Syndetis pairs passive LLDP/CDP neighbor discovery with user-initiated PROFINET DCP discovery on the wired link. The PROFINET scan runs at Layer 2 with wired IPv4 off.
| PROFINET discovery | Mobile dashboard status |
|---|---|
| Passive LLDP discovery | Diagnostic report download |
|---|---|
Actual Syndetis v0.7.0 field testing on a Siemens SIMATIC S7-1200 PLC. Sensitive network identifiers have been redacted for privacy.
See the November 27, 2026 field acceptance record.
| Field Hardware (Link & IP) | Main Menu |
|---|---|
| Physical link up, 100 Mbps full-duplex readout | OLED navigation with UP / DOWN / OK buttons |
| Switch Discovery (CDP) | Local Wi-Fi Web Dashboard |
|---|---|
| Passive CDP/LLDP neighbor switch & MAC discovery | Live status view on mobile via 192.168.4.1 |
- Detect Ethernet link status, negotiated speed (10/100 Mbps), and duplex.
- Passively discover neighboring equipment through LLDP and CDP.
- Display advertised switch/device identity, port, and VLAN information when available.
- Listen for neighbor advertisements without starting an IPv4 test.
- Discover responding PROFINET stations with an OLED-initiated DCP Identify All scan while wired IPv4 is off.
- Request an IPv4 configuration using DHCP and display the IP address, subnet mask, gateway, and DNS servers.
- Configure a temporary manual IPv4 address, including ARP conflict detection.
- Ping the gateway or a custom IPv4 address, showing replies, packet loss, and response times.
- Stop, release, and repeat network tests without rebooting the device.
- Navigate the device using a 128×64 OLED and UP / DOWN / OK buttons.
- Enable a local Wi-Fi access point and view Ethernet status, LLDP/CDP neighbors, PROFINET results and counters, and DHCP results in a browser.
- Start or stop a DHCP test through the web dashboard.
- Export a JSON diagnostic report, with network identifiers omitted by default.
- Update the firmware over Ethernet or Wi-Fi, with a USB-UART recovery path.
Syndetis is intended for quick, targeted diagnostics, not continuous monitoring or comprehensive network scanning. The current hardware supports 10/100 Mbps only; it does not measure cable length, certify cabling, or provide Gigabit Ethernet link negotiation. Advertised VLAN information is not a complete VLAN inventory. Passive discovery depends on neighboring equipment sending LLDP/CDP advertisements.
- Connect the Ethernet cable to the port you want to inspect.
- Open Link & IP to check the physical connection, speed, and duplex.
- Open Switch Info to see any LLDP/CDP neighbors detected on the link.
- Use Network Tests when you need DHCP, manual IPv4 configuration, or ping diagnostics.
- Release any active test configuration before moving to another port.
By default, Syndetis does not start an IPv4 diagnostic session until you explicitly request one. Not receiving a ping response does not, by itself, prove that a device is offline. Use active tests only on networks you are authorized to troubleshoot.
Use UP and DOWN to move through menus, press OK to select, and hold OK for approximately 500 ms to go back. Numeric editors support button repeat.
Main menu order in v0.7.0 is Link & IP, Switch Info, PROFINET, Network Tests, Device Info, Web Access, About, Settings, Diagnostic Report.
- Connect to an authorized diagnostic port with an Ethernet link. The tester's wired interface can stay without an IPv4 address.
- On the OLED, select PROFINET → Start discovery. The tester sends one DCP Identify All request and listens for five seconds. Hold OK to cancel.
- Open View results to scroll the last inventory. Select a station to see its advertised details. Unnamed stations appear by MAC address. A three-second cooldown follows each scan.
The inventory shows the source MAC and, when advertised, the station name, device type, IPv4 address, subnet mask, gateway, vendor and device IDs, role flags, and IP status. It flags potential duplicates within the sample and marks results historical after link loss. The dashboard displays the same discovery results and counters. Starting a scan requires the physical buttons.
The Layer 2 query reads advertised information. Boot, link changes, opening the menu, and dashboard polling leave DCP transmission off. Results depend on which devices reply and how the connected segment forwards Layer 2 traffic. See the PROFINET implementation and discovery scope.
From the device's main menu, select Web Access → Enable. Connect to the Wi-Fi network shown on the OLED using the displayed password, then open:
The dashboard shows live Ethernet information, IP/DHCP state, discovered switch information, and PROFINET results. Browser dashboard access is through the device's Wi-Fi hotspot, not its wired Ethernet address.
The prototype dashboard has no separate login once hotspot access is enabled. Use it on trusted networks and disable Web Access when you're finished.
- On the OLED main menu, choose Web Access → Enable and wait for Web Access to start.
- Open Web Access → Connection details for the hotspot name and password. Join that Wi-Fi network and open http://192.168.4.1/ in your browser.
- In the dashboard's Diagnostic report section, wait for the first status update, then select Download diagnostic report to save
syndetis-diagnostic-report.json.
The report includes firmware version and uptime, Ethernet initialization and link status, negotiated speed and duplex, wired addressing mode and state, DHCP status and timing, and LLDP/CDP discovery status, counters, neighbor protocol, TTL, age, and expiry. It includes Ethernet and DHCP error details when available. Ping statistics and device wall-clock timestamps are unavailable in the report.
Network identifiers are omitted by default. Select Include network identifiers to include available MAC and IP addresses, subnet, gateway and DNS settings, switch, chassis, port and VLAN details, and the PROFINET device inventory. The default PROFINET section contains scan state, count, age, validity, completion, error and drop counters, and aggregate conflict flags. These optional identifiers can reveal network topology when you share the file. Review reports before sharing them.
The report uses the last valid dashboard snapshot and records browser UTC receipt and export times, snapshot age, and whether the data is stale. A failed status poll or a snapshot older than four seconds marks the data stale. You can still download it after disconnecting if the dashboard tab stays open and has received a valid update. Reloading or closing the page discards the cached snapshot.
The OLED Diagnostic Report item follows Settings in the main menu. It shows the dashboard URL when Web Access is on, asks you to enable Web Access when it is off, and shows Check Web Access during startup, shutdown, or an error. Short or held OK returns to the main menu with the item selected. Wi-Fi activation stays in Web Access, and the download happens in the browser.
JSON reports can be opened in a text editor, such as VS Code, or processed with standard JSON tools. On Linux, python3 -m json.tool syndetis-diagnostic-report.json prints the report in a readable format.
| Qty | Part | Specification |
|---|---|---|
| 1 | WT32-ETH01 | ESP32, 4 MB flash, onboard LAN8720-family RMII PHY, 10/100 Mbps |
| 1 | OLED display | SH1106, 128×64, I²C, suitable for 3.3V operation |
| 3 | Momentary push buttons | Normally open; UP, DOWN, OK |
| 3 | Resistors | 10 kΩ, one external pull-up per button |
| 1 | Power source | Regulated 5V USB power bank and suitable power leads |
| 1 | USB-UART adapter | 3.3V logic, for initial flashing and recovery |
| As needed | Wiring and assembly materials | Jumper wires, breadboard or prototyping board |
| 1 | Ethernet patch cable | For field testing |
The USB-UART adapter is a programming accessory and does not need to remain attached during normal use. No custom PCB, enclosure, integrated battery charger, or SD card is required for the current prototype. Component prices vary by supplier and region; this is a parts list rather than a fixed-price kit.
Current GPIO assignments:
| Connection | GPIO |
|---|---|
| OLED SDA / SCL | GPIO32 / GPIO33 |
| UP / DOWN / OK | GPIO36 / GPIO39 / GPIO5 |
The OLED address is detected at 0x3C or 0x3D; automatic probing expects exactly one responding address. The authoritative pin mapping and board settings are in main/board.h.
The current build uses a WT32-ETH01, an SH1106 128×64 I²C OLED, three active-low navigation buttons, and three external 10 kΩ pull-up resistors. It is powered from a regulated 5V USB power bank output connected to the board's 5V and GND pins, not through a USB connector on the WT32-ETH01.
Open the full-size wiring overview
OLED connections
| OLED pin | WT32-ETH01 connection |
|---|---|
| VCC | 3.3V |
| GND | GND |
| SDA | GPIO32 |
| SCL | GPIO33 |
Button connections (active-low)
Use the following circuit independently for each of the three buttons:
3.3V ──[10 kΩ]──┬── GPIO input
│
[BUTTON]
│
GND
The GPIO connects to the junction between the pull-up resistor and the normally open momentary push button. The resistor connects to the WT32-ETH01's 3.3V rail, not to 5V.
- Released: the pull-up holds the GPIO HIGH (3.3V).
- Pressed: the button connects the GPIO to GND, making it LOW (0V).
- Use one separate 10 kΩ resistor per GPIO; all three circuits share the board's 3.3V rail and GND.
| Button | GPIO | External resistor | Switch connection |
|---|---|---|---|
| UP | GPIO36 | 10 kΩ from GPIO36 to board 3.3V | GPIO36 to GND when pressed |
| DOWN | GPIO39 | 10 kΩ from GPIO39 to board 3.3V | GPIO39 to GND when pressed |
| OK | GPIO5 | 10 kΩ from GPIO5 to board 3.3V | GPIO5 to GND when pressed |
Each GPIO input should be held HIGH through its own 10 kΩ pull-up to the WT32-ETH01's 3.3V rail and pulled LOW by its button when pressed. The three buttons share a common GND return. Do not connect 3.3V directly to GND when a button is pressed. GPIO36 and GPIO39 require external pull-ups; the firmware also disables internal pulls for all three buttons.
Power connections
| Power-bank output | WT32-ETH01 connection |
|---|---|
| Regulated +5V | 5V pin |
| 0V / negative | GND pin |
Important: Check the actual WT32-ETH01 module pin labels before making connections; the diagram is a simplified overview, not a pin-position-accurate schematic. Use only a suitable regulated 5V power source on the 5V input, and verify polarity and common ground before powering on. Never apply 5V to a GPIO or the 3.3V rail. GPIO5 is a boot-strapping pin on the ESP32; avoid holding OK during reset or power-up. The present prototype uses a power bank; it has no integrated battery charging circuit.
This is still prototype hardware; a custom PCB and enclosure are potential future improvements.
- With power disconnected, assemble the OLED and buttons using the wiring tables above.
- Obtain the current firmware release or build the firmware from source as described below.
- Use a 3.3V-logic USB-UART adapter and follow
RESTORE_USB.mdand the release documentation for initial flashing. A raw OTA application image alone is not a complete blank-device installation. - After flashing, boot normally with the programming strap released. Check that the OLED displays the main menu and that all three buttons respond.
- Connect to a known working Ethernet port. Check Link & IP, then Switch Info if the connected equipment advertises LLDP/CDP.
- On an authorized test network, run DHCP and ping as appropriate, then release the active IPv4 configuration.
- Enable Web Access, open the dashboard, download a diagnostic report, and disable Web Access when finished.
The firmware is written in C and targets ESP32 using ESP-IDF v6.1, pinned to SDK commit:
fff9895c82d744c7237be8847347bdd1b07c6643
Install and activate the appropriate ESP-IDF environment, then run from the repository root:
idf.py -B build-final build
python3 scripts/verify_build.py build-finalThe application image is generated at build-final/Syndetis.bin.
Linux setup and dependencies are described in LINUX_SETUP.md. On Windows, use an ESP-IDF terminal and the available Python command (python or py -3 instead of python3, if needed).
For initial flashing, partition-layout changes, or USB recovery, follow RESTORE_USB.md and the release documentation rather than flashing an old factory image over the current OTA layout.
The project contains C host tests, Python verification, Node.js checks, and browser-based tests for the dashboard and updater. With the required toolchain and dependencies installed:
npm ci --ignore-scripts
npx playwright install chromium
python3 scripts/run_tests.py
python3 scripts/run_ota_crypto_tests.py --idf-path "$IDF_PATH"
python3 tests/ota_identity_test.py --idf-path "$IDF_PATH"See the v0.7.0 release manifest for build and image verification and the v0.5.2 release manifest for historical results.
On the device, open Settings → Firmware Update and use one of the following addresses while update mode is active:
| Connection | Update page |
|---|---|
| Device Wi-Fi hotspot | http://192.168.4.1:8080/update |
| Ethernet (after IPv4 is configured) | http://<device-ip>:8080/update |
Upload a trusted, strictly newer Syndetis application .bin image. The firmware uses two OTA application slots, image validation, and trial-boot rollback.
Download Syndetis-v0.7.0.bin and its SHA-256 checksum file from the current stable release.
Important: Updates use HTTP without transport encryption or cryptographic authentication of the firmware author. Only use trusted images, a controlled local connection, and stable power during an update. USB recovery details are in RESTORE_USB.md.
v0.7.0 is the current stable firmware following the project owner's November 27, 2026 field acceptance on a Siemens SIMATIC S7-1200 test setup. v0.6.0, the previous stable release, introduced browser JSON diagnostic reports and the OLED Diagnostic Report screen.
- Current stable release — v0.7.0
- Changelog
- v0.7.0 release manifest
- v0.7.0 field acceptance
- Historical v0.5.2 release manifest
- Historical v0.5.2 field acceptance results
- Reliability report
The goal remains the same: quick, easy, informative Ethernet diagnostics. The next hardware generation should keep everyday field tasks simple, even if more advanced features become available.
| Area | Direction |
|---|---|
| Interface | Small OLED + browser dashboard, or screenless device + browser dashboard |
| Portable power | Integrated battery and charging |
| Ethernet | Researching 10/100/1000 Mbps link negotiation, including modular Ethernet hardware alongside an ESP32-based controller |
| Data logging | Optional local storage or SD card logging under consideration |
| Cable diagnostics | Exploring VCT/TDR capabilities where supported by the selected hardware |
| Mechanical design | More compact, field-friendly assembly and enclosure |
Both interface concepts use the browser dashboard. No dedicated native mobile application is planned.
V2 is in the research and design stage. No hardware platform, final feature set, price, or release date has been selected. Gigabit link negotiation is a research goal, not a promise of gigabit throughput. Affordability, component availability, power consumption, and ease of replication will guide hardware selection. The current WT32-ETH01 version remains usable independently of this roadmap.
This remains a personal project and a work in progress. Contributions and suggestions grounded in real troubleshooting needs are welcome. If you build Syndetis or use it in the field, feedback about your hardware, use case, and practical limitations is especially helpful.
For questions, feedback, or collaboration regarding Syndetis:
Email: projects.theo79@gmail.com
You can also open a GitHub Issue for bug reports, feature requests, or technical discussions. Remove sensitive network information before posting diagnostic reports publicly.
Syndetis source code is released under the MIT License. See LICENSE.