Dear customer:
Please read carefully the user manual before using the indicator!
                                                               1
                                 X K 3 1 9 0-C 8
Chapter 1 Profile
     XK3190—C8 weighing indicator adopts MCS—51 single chip microprocessor and high-speed Σ-△A/D
switch technology, which performs conversion and displays weight, with the maximum conversion speed
reaching up to 80 times/second. The display can be easily connected to the resistance strain gauge load cell to
form batching scale, quantitative packing scale and control scale etc., which are applicable to various control
occasions where high-speed and high precision weighing are required.
1. Integration of additive scale, subtracting scale, catchweigher function, with 3-channel input of external
control and 3-channel control output;
2. Standard asynchronous serial communication interface (RS232 or RS422/485), with flexible communication
mode (continuous send and command response);
3. 0-20mA/4-20mA (or 0-5V/0-10V) DA precision output, adjustable;
4. Upper and lower limit alarm output setting;
5. High-precision A/D conversion with readability up to 1/30000;
6. 5-point nonlinear correction;
7. When changing indicator, re-calibration is not required; and you can use it with parameters of original
indicator;
8. Scoreboard output;
9. Flexible peak holding function;
10. Storage, inspection and deletion function of information such as summation of weighing data and
accumulated frequency etc.; power-off data protection is provided;
11. It can be connected to serial printer to print weighing record, accumulated amount or parameters; manual
or automatic print is optional;
12. It has tare function; when the automatic control is activated, the automatic tare can be selected;
13. The digital filtering intensity of AD data can be changed according to requirements;
14. Many kinds of operating information and error message prompts;
15. Selection of printing unit: kg, t, g, lb;
16. Real-time clock, calendar, automatic leap year, leap month display, which are not affected by power off;
17. Factory defaults recovery function;
18. Strong immunity and high reliability.
                                                     2
                                  X K 3 1 9 0-C 8
                                  Chapter 2 Main Parameters
8. Display:                        Single-row 7-bit LED, character height 0.5, and 11 status indicating
                                   lamps
9. Division:                       1/2/5/10/20/50/100 optional
10. Clock:                         Display real time and date.
11. Keyboard:                      Adopt 5 soft touch buttons
12.Scoreboard interface:           Adopt serial output, 20mA constant current source signal.
13 Communication interface:        Serial RS422/RS422/RS485, optional; baud rate 1200~9600 optional
14.Print interface:                Shared with serial port, and can be connected to serial printer.
15. Relay output:                  Capacity AC:220V; 0.5A
16. External input:                Switch contact (close control is effective)
17. Power supply:                  AC 110~230V, 50/60Hz 1A
18.Service temperature,
                                   0~40℃;≤90%RH
moisture:
19.Storage and transportation
                                   -20~50℃
temperature:
20. External dimension:            Housing: 150×76×85mm (width × height × depth)
                                   Panel: 172×93×3mm (width × height × thickness)
21. Dead weight:                   Approximately 700 gram
                                                     3
                                  X K 3 1 9 0-C 8
               Chapter 3 Installation, Interface and Data Format
I.      Diagram of Front and Back Function Buttons of Indicator
The meanings of the 11 indicating lamps on display panel are showed as follows from left to right:
Power supply: power supply indicating lamp
Operation: automatic operation status
Zero point: zero zone indication
Net weight: net weight status
Stabilization: stabilization status
IN: three input indications (1, 2, 3 represents three inputs respectively)
OUT: three output indications (1, 2, 3 represents three outputs respectively)
The five buttons on display panel has the following meaning respectively:
Symbol Button name             Meaning
[ F1 ] button Press [F1] and [Operation] buttons simultaneously to examine the inner code
          [Operation]
                            It also serves as stop button. It is return button in parameter setting status.
          button
          [Zero setting]
                            It is shift key in parameter setting status.
          button
          [Print input]
                            It is print button under the situation of displaying weighing value.
          button
                                                       4
                                X K 3 1 9 0-C 8
All interfaces in Figure 3-2 will be described in detail below, please read the following detailed interface
description while referring to the interface position in Figure 3-2.
                                                    5
                                  X K 3 1 9 0-C 8
The connection with load cell adopts the six wire system connection mode. Please refer to the interfaces in the
Diagram of Back Function Buttons, Figure 3-4. Detailed definitions are given below:
Tips: If the long line compensation function (four wire system connection mode) is not used, the pins of
“EX+” and “SEN+”, “SEN-” and “EX-” in Figure 3-4 must be short-connected, or otherwise, the
indicator can not be calibrated and weigh normally.
                                                     6
                                  X K 3 1 9 0-C 8
Table 3-1 Definition of Pin                                            Table 3-2 Selection of Communication
Interface
232 communication          485 communication
                                                                Selection          of   Selection of jumper
GND: Grounded              A:      RXD+       receiving         communication
                                                                                   JP1          JP2
RXD: Receiving end         positive data                        interface
of indicator               B: RXD-            receiving         RS232C
                                                                                      Left         Left
TXD: Sending end of        negative data                        (Factory defaults)
indicator                  Z: TXD- sending negative
                                                              RS485C                  Right        Right
                           data
                           Y: TXD+ sending positive
                           data
This indicator can select continuous send or command response mode:
Continuous send mode:
    The transferred data is the current weight (gross weight or net weight) displayed on the indicator. Each
frame of data is composed of 12 groups of data. The format is as follows:
       C8 indicator can choose 3 analog output modes: 0~5V, 0~10V voltage signal output and 4~20 mA
current signal output (It can be also adjusted to 0~20 mA actually). The electric current loop adopts internal
electrical power supply mode, the output mode is selected by jumper JM3~JM5 (See Figure 3-3) on main
board, and for the setting mode, please see Table 3-3. The factory setting is 4~20 mA electric current loop. The
switch of analog output is controlled by the C bit of parameter [H ABC] under parameter [SET 1].
                              Table 3-3 Setting of Analog output
                                                               Selection of jumper
                                   Analog output
                                                              JM3      JM4     JM5
                                                     7
                                   X K 3 1 9 0-C 8
                                       0—10V                  Down       Left      Up
     Print
     The serial port communication RS232 connection mode is adopted. By means of selecting connection to
serial printer in indicator parameter Set 1, the weighing data can be printed through the serial port. Mainly
hand print and automatic print are available, which are introduced respectively below:
     1. Hand print
     Single print: In weighing status, press “Input/ Print” button to print the current time, date, net weight, tare
weight, accumulated frequency and accumulated weight.
     Print record: At the mode of 0, 1, 2, all weighing records, including the time, date, net weight, tare weight,
accumulated frequency and accumulated weight for each weighing, can be stored and printed. For concrete
operations, see [Set 3].
     2. Automatic print
     After selecting printer and automatic print in parameter settings, information such as the current time,
date, net weight, tare weight, accumulated frequency and accumulated weight will be printed automatically
when a process is finished every time during the automatic control process.
     Note: new printing cannot be proceeded until it returns to zero after every print; in status such as not
selecting printer or in hand peak holding function, the hand print function is invalid; when communication in
[Set      1] is not selected or communication is selected but the serial printer is not selected, print is not valid;
when the set baud rate is not 9600, [Err     P] will be prompted.
     Storage
     Storage is often used together with print, and is also divided into hand storage and automatic storage.
Automatic storage should be enabled in parameter settings. Attention must be paid to several points during
storage:
     1. Hand storage cannot be conducted in catchweighing mode.
     2. The next storage cannot be executed until it returns to zero after every time of storage.
     3. After the control mode (i.e. additive scale, subtracting scale, catchweigher) is changed, it needs to enter
the parameter setting 0 to eliminate the accumulated results, or otherwise the data may have error.
                                                        8
                                      X K 3 1 9 0-C 8
[Operation] button: the current setting is not saved, and return to the previous parameter
              [Input] button: make sure to save the current parameter setting, and enter the next parameter
             setting
       Press [F1] button and [Zero setting] button simultaneously to enter parameter setting selection interface.
The setting catalogues are:
【SEt        0】 : enquiry parameter;
【SEt        1】 : general parameter;
【SEt        2】 : control parameter;
【SEt        3】 : print record (no such function in catchweighing mode)
    [Note] Please pay attention to the instruction in remarks for each parameter. Part of parameters will
only be displayed under specific mode or conditions.
                                                          9
                               X K 3 1 9 0-C 8
                                                               Press [Zero setting] button to move the current
4     [d**.**.**]      Current date setting                    flicker bit, press [Tare] button to modify parameter
                                                               value
                                                               Press [Zero setting] button to move the current
5     [t**.**.**]      Current time setting                    flicker bit, press [Tare] button to modify parameter
                                                               value
6     [A ****]         Zero position calibration
8     [C ****]         Nonlinear correction point 1 Restricted parameter. The calibration switch must
                                                    be opened (turn the calibration switch CAL to the
                       CAL Coefficient 2 (nonlinear left ON position) when changing, and input the
9     [d ****]                                      correct password.
                       correction)
                                                    Press [Input] button to check the parameter
10    [E    ****]      Nonlinear correction point 2 value one by one;
                                                     10
                                   X K 3 1 9 0-C 8
                       Accumulated          frequency          of
5     [n 3 ****]                                                    Ditto
                       Channel 3
                       Accumulated weight of Channel
6     [A******]                                      Ditto
                       3
                                                                    The following parameters are same with the latter
7     [d**.**.**]      Setting of current date
                                                                    part of Table 1.
Table 4-3
Para- Indicator
                       Parameter Specification                                            Remarks
meter Display
                       Hardware selection
                       A - Communication (0: communication is not For                 example:          When
                                                                           communication is required,
                       required, 1: communication is required)
                                                                           large-screen and analog are not
1     [H     ABC]      B-Large-screen (0: large-screen is not required, 1:
                                                                           required, set it to [H 100].
                       large-screen is required)
                                                                           Note: This setting will affect
                       C-Analog (0: analog is not required, 1: analog is the following display menu.
                       required)
                       Relevant Parameters of Zero Zone
                       A-zero setting range upon startup (0~5)
                       B-zero setting range by hand (0~5)
                                                                             For example: if set the zero
                       A,B 0          1       2       3      4      5        setting range upon startup to
                                                                             20%, the zero setting range by
                       F .S% 0        2       4       10     20     100
2     [n     ABC]                                                            hand to 4%, and the zero
                       C-zero tracking range (0~8)                           tracking to 0.5e, it will be set to
                       When it is set to 0, the tracking function is closed. [n 421].
                       For other values, see the following table:
                       C       1    2       3         4   5         6       7         8
                                                          11
                                  X K 3 1 9 0-C 8
                          Communication Mode:
                          0-command response mode (Refer to Chapter 3); It won’t be displayed when
6      [tod      *]
                          1-continuous send mode                              communication is not required.
                          2-connect to serial printer
                          Automatic accumulated print:
                          0-automatic accumulation                            Accumulation         and      print
7      [AtP      *]
                          1-automatic accumulation without print              conditions should be satisfied.
                          2-automatic accumulation and automatic print
                          Print Unit:
                          0-kg (kilogram)                                     It’s effective only when printing.
8      [Unit     *]       1-g (gram)                                          It won’t be displayed when
                          2-t (ton)                                           communication is not required.
                          3 – lb (lbs)
                          Peak Holding:
                          0-Peak holding is closed.
                                                                              Hand mode includes pressing the
                          1-Peak holding is effective, and the holding will
9      [F        *]                                                           input button and input terminal
                          be cancelled automatically after returning to zero. to obtain input signal.
                          2 - Peak holding is effective; press the button
                          manually to cancel holding.
                          The corresponding weight of analog output zero It won’t be displayed when
10     [AL*****]
                          point                                               analog output is not required.
                          The corresponding weight of analog output full It won’t be displayed when
11     [A******]
                          range                                            analog output is not required.
                          DA inner code (0-30000) when analog output is at
                                                                           The zero point for calibration
                          zero point
12     [PL ***]                                                            analog output of this parameter
                          (Output 4-20mA signal is about 12520;
                                                                           can be modified.
                          output 0-5V/0-10V is 0)
                          DA inner code (30000-65535) when analog output
                                                                           The zero point for calibration
                          is at full range
13     [PH ***]                                                            analog output of this parameter
                          (4-20mA output is about 62590;
                                                                           can be modified.
                          0-5V/0-10V output is about 65200)
                          Whether to print this set parameter:
                                                                           This item won’t be displayed
14     [Prt      *]       0: No.
                                                                           when there is no printer.
                          1: Yes.
Table 4-4
Para- Indicator
                          Parameter Specification                Remarks
meter Display
                          Control Mode
                          0: 1 kind of additive mode of batching
                          1: 1 kind of subtraction mode of
                                                                 For work flows of all kinds of mode, see
1      [CP       *]       batching
                                                                 Chapter 6.
                          2: 2 kinds of additive mode of
                          batching
                          3:catchweighing mode
                                                                 The number of control process (0~99, 0
2      [Pt        0]      Number of cycles
                                                                 stands for indefinite times)
Please select the corresponding parameter setting according to the set [Control Mode].
                                                      12
                            X K 3 1 9 0-C 8
Mode 0, 1 (Additive mode or subtraction mode for 1 kind of batching material)
                     Advanced Control Parameters
                     A-quick or slow feed status
                         0: When quick feeding, only the
                     quick feed is opened.
                         1: When quick feeding, both the
                     quick and slow feed are opened
                     simultaneously.
7     [d******]      Allowance
                                                      1. When the indicator is discharging, if the net
                                                      weight is less than that of zero zone value, it
                                                      will be deemed as discharge completion;
8     [L******]      Zero zone
                                                      2. The indicator print and accumulation
                                                      cannot be conducted until the gross weight is
                                                      greater than the zero zone value.
                     0.0~9.9 seconds feed measurement To avoid weight misjudgment caused by
9     [t0   **]
                     delay                            weight impact when starting.
                     0.0~9.9 seconds delay of quick feed
10    [t1   **]
                     over
                     0.0~9.9 seconds delay of slow feed
11    [t2   **]
                     over
                     0.0~9.9 seconds gradual feed output It won’t be displayed when there is no gradual
12    [t3   **]
                     time                                feed.
                     0.0~9.9 seconds gradual feed interval It won’t be displayed when there is no gradual
13    [t4   **]
                     time                                  feed.
                                               13
                             X K 3 1 9 0-C 8
                     0.0~9.9 seconds time
14    [t5    **]     Mode 0: discharge over delay
                     Mode 1: qualified output time
15    [t6    **]     0.0~9.9 seconds re-feed delay
                                                 14
                            X K 3 1 9 0-C 8
                    0.0~9.9 seconds material 2 feed over
13    [t2     **]
                    delay
                    0.0~9.9 seconds gradual feed output This item won’t be displayed when there is no
14    [t3     **]
                    time                                gradual feed.
                    0.0~9.9 seconds gradual feed interval It won’t be displayed when there is no gradual
15    [t4     **]
                    time                                  feed.
                    0.0 ~ 9.9 seconds discharge finish
16    [t5     **]
                    delay
                                               15
                                   X K 3 1 9 0-C 8
                          Calculation Delay (0~9.9) Seconds:
9      [t2    **]         The indicator has no action within t2
                          after t1 is calculated, wait with delay.
                          Signal Sending Time (0 ~ 9.9)
10     [t3    **]         Seconds:
                          The indicator sends catchweighing
                          signal, with duration of t3 second.
                          Whether to print this parameter:
11     [Prt    *]         0: No.                                   It won’t be displayed when there is no printer.
                          1: Yes.
★Please confirm H≥L during setting, or otherwise the indicator cannot work normally, and may cause
unexpected errors. The above time does not take reaction time such as relay action into consideration.
IV. Record Print [SEt      3]
V. Calibration
     Turn the calibration switch CAL to the left ON position to open the calibration switch. Then press [F1]
button and [Input] button simultaneously, the indicator displays [--CAL--], indicating entering calibration
status. Press [Input] button to enter. For specific calibration parameter instructions and operation, refer to the
following table (* stands for the original set value):
Table 4-7
        Parameter
Step                       Parameter Instruction                       Operation Instruction
        Display
2 [dC *] Digits of decimal point (0-3) Press [Input] after modifying parameters
                                                       16
                                X K 3 1 9 0-C 8
                        Full value (The alarm limit set
3    [F******]                                                       Press [Input] after modifying parameters
                        automatically is full value plus 9 division)
                        Save the original zero position:
                        0: the current zero position needs to be
                                                                     Input 0 to enter Step 5 (recommended),
4    [r      0]         reconfirmed;
                                                                     Input1 to enter Step 7.
                        1: skip over the current zero position
                        confirmation.
                                                                     Confirm that the current weighing
5    [noLoAd ]          Zero position confirmation                   platform has no load and the stability
                                                                     lamp is ON, then press [Input].
6    [*******]          Display the current AD code                 Press [Input] after the AD code is stable.
8    [*******]          Display the current AD code                 Press [Input] after the AD code is stable.
                                                                     Change to the weight value of current
                                                                     weights, press [Input] button to enter Step
                                                                     12 and complete the calibration;
9    [ *******]        The weight of current loaded weights
                                                                     Change to the weight value of current
                                                                     weights, press [F1] button to enter the
                                                                     nonlinear correction flow of Step 10;
                                                                  th
                       Load weights, calibrate the weight of n Press [Input] to enter the next step after
10   [AdLoAd* ]
                          point (n<=5)                               weights are loaded.
                                                                     Press [Input] to enter Step 9 cyclically
                                                                     after the AD code is stable. (At most five
11   [*******]         Display the current AD code
                                                                     -point nonlinear correction can be
                                                                     conducted)
                                                                     The calibration is finished. Return to
12   [*******]         Display the current weight value
                                                                     weighing status.
               Please put the calibration switch at OFF position after calibration is finished
                                                    17
                                       X K 3 1 9 0-C 8
                              Chapter 5 Operating Instructions
I. Startup and zero setting upon startup
       After connected with the power, the display performs self-check of strokes “0-9”, then shows the version
No.. After that, it enters into weighing mode. After startup, if the weight of empty scale deviates from zero
point, but remains within the zero range, the display will perform zero setting upon startup. If the weight is out
of the zero setting range, the display shows the weight based on the calibrated zero point. For the zero setting
upon startup, please refer to the setting of parameter B in the parameters 1:[n ABC] as described in Chapter 1
【SEt      1】.
II. Zero setting manually
     When the display value deviates from zero point, but remains within the range of zero setting manually,
ad the light is steady on, please press the button 【Zero setting】to make the display value reset to zero. The
zero point light is ON. For the range of zero setting manually, please refer to the setting of parameter A in the
parameters 1:[n ABC] as described in Chapter 1 【SEt 1】.
III. Tare
     Under weighing status, when the displayed weight is a positive value and weighing is stable, press the
button 【Tare】to deduct the displayed value as tare. Then the displayed net weight is 0, with the net weight
indicator light ON.
IV. Setting of date and time
     Set the date through the contents [d**.**.**] and the time through [t**.**.**] in parameters setting 【SEt
0】. Press the button 【Zero setting】to change the flicker bit, and 【Tare】to change the size. After completion
of setting, press the button【Input】for setting of other parameters or exit from setting by pressing the button
【 F1 】.
V. Startup/stop
     For startup or stop, press directly the button 【Run】on key board, or input an impulse signal from the
“Startup” end of back panel, the indicator is ready to enter into control mode or exit from control mode.
VI. Peak holding
     By means of setting the parameter [F        *] in parameters【SEt 1, select the peaking holding mode:
0-peak holdings is off.
1-peak holding is valid, and it is cancelled automatically after zero setting.
2-peak holding is valid. Press the button 【input】to enable peaking holding; press the button 【input】once
again to disable peaking holding (under this status, the button 【input】has no save manually/print function).
VII. Input and output function
The input and output has the following meanings under different modes:
                   Input                                       Output
 Mode
                   I1             I2          I3               O1                  O2                  O3
 Mode 0            startup/stop   feed        discharge        Quick feed          Slow feed           discharge
 Mode 1            startup/stop   discharge   ——               Quick discharge     Slow discharge      complete
 Mode 2            startup/stop   feed        discharge        Feed material 1     Feed material 2     discharge
 Mode 3                           External
                                                               Net       weight≤
                                                                                   Lower limit < net
                                                                                                       Net weight    ≥
                   startup/stop   control     ——                                   weight < upper
                                                               lower limit                             upper limit
                                  input                                            limit
                                                          18
                                   X K 3 1 9 0-C 8
   Press the button 【 F1 】under weighing mode to enquire the following parameters respectively:
Mode 0, 1:batching value, date, time
Mode 2 :batching value 1, batching value 2, date, time
Mode 3 :upper limit, lower limit, date, time
                                                       19
                                 X K 3 1 9 0-C 8
                 Chapter 6 Explanations of Control Procedure
   The four working modes of the indicator are explained in details as below:
I. Mode 0(additive mode with 1 batching material)
    The double-speed batching of 1 kind of material mainly involves the following parameters: batching value
A1, quick feed lead b, slow feed lead C, allowance, zero value L. Please refer to the following figure for
understanding of the functions, meanings and time sequence of control input and output of various parameters
during the process:
     Additive mode of 1 batching material:
Note: A—batching value; b—quick feed lead value; C—slow feed lead value; L—zero zone value.
       t0—measurement delay;t1—quick feed over delay;t2—slow feed over delay;t3—gradual feed output
 time;t4—interval time of gradual feed;t5—discharge over delay.
       The schematic diagram of slow feed 1 shows the slow feed output when both the quick feed and slow
                                                    20
                                  X K 3 1 9 0-C 8
feed are ON during quick feed process, and gradual feed exists.
       The schematic diagram of slow feed 2 shows the slow feed output when only the quick feed is ON
during quick feed process, and without gradual feed.
      The control procedure in the above diagram is composed of 4 processes including quick feed, slow feed,
gradual feed and discharge.
(1)       Quick feed-- When the control procedure starts, the quick feed output gives out a signal, and the
          corresponding O1 relay is closed. When the weight is added to the quick feed stop value A-b, the
          quick feed output signal is cancelled, the corresponding O1 relay is switched off.
(2)       Slow feed-- After a period of delay time t1 (quick feed over delay), the slow feed output gives out a
          signal, and the corresponding O2 relay is closed. When the weight is added to the slow feed stop
          value A-C, the slow feed output signal is cancelled, the corresponding O2 relay is switched off. If the
          parameter is set to both quick feed and slow feed ON, the slow feed output gives out a signal since
          the beginning, and the corresponding O2 relay is closed until the weight reaches up to the slow feed
          stop value A-C.
(3)       Gradual feed-- If the parameter is set with gradual feed, the O2 relay corresponding to slow feed will
          be closed for a period of t3, and switched off for a period of t4. Gradual feed is carried out through
          such repeated cycle, until the weight reaches up to the allowance range of batching value, i.e. the
          qualified area.
(4)       Discharge-- Discharge output sends out a signal, and the corresponding O3 relay is closed. After the
          weight is less than the value L in zero zone, the discharged is considered completed, which
          corresponds to point M in the figure. At this moment, after another delay of t5, the discharge output
          signal is cancelled, and the corresponding O3 relay is switched off. A complete control procedure is
          finished.
    Note: during the above process, if the slow feed lead is bigger than that of quick feed lead, i.e. C>b, then
  the slow feed output won’t give out signal, and the corresponding O2 relay remains switched off. If no
  gradual feed is set for parameters, the above gradual feed process (3) is not included. The turning off of
  discharge should meet the conditions that the weight is less than zero zone value.
    Please refer to the following figure for understanding of the functions, meanings and time sequence of
control input and output of various parameters during the process:
Note: A—batching value; b—quick subtraction lead value; C—slow subtraction lead value;
       t1—quick subtraction over delay;t2—slow subtraction over delay;t3—gradual feed output time;
t4—interval time of gradual feed;t5—discharge over delay
      The schematic diagram of slow subtraction 1 shows the slow subtraction output when both the quick
subtraction and slow subtraction are ON during quick subtraction process, and gradual feed exists.
       The schematic diagram of slow subtraction 2 shows the slow subtraction output when only the quick
                                                       21
                                   X K 3 1 9 0-C 8
subtraction is ON during quick subtraction process, and without gradual feed.
      The control procedure in the above diagram is composed of 4 processes including quick subtraction,
slow subtraction, gradual feed allowance treatment and discharge.
(1)       Quick subtraction -- When the control procedure starts, the quick subtraction output gives out a
          signal, and the corresponding O1 relay is closed. When the weight is reduced to the quick
          subtraction stop value A-b, the quick subtraction output signal is cancelled, the corresponding O1
          relay is switched off.
(2)       Slow subtraction -- After a period of delay time t1 (quick subtraction over delay), the slow
          subtraction output gives out a signal, and the corresponding O2 relay is closed. When the weight is
          reduced to the slow subtraction stop value A-C, the slow subtraction output signal is cancelled, the
          corresponding O2 relay is switched off. If the parameter is set to both quick subtraction and slow
          subtraction ON, the slow subtraction output gives out a signal since the beginning, and the
          corresponding O2 relay is closed until the weight reaches up to the slow subtraction stop value A-C.
(3)       Gradual feed -- If the parameter is set with gradual feed, the O2 relay corresponding to slow
          subtraction will be closed for a period of t3, and switched off for a period of t4. Gradual feed is
          carried out through such repeated cycle, until the weight reaches up to the allowance range of
          batching value, i.e. the qualified area.
                                                     22
                                   X K 3 1 9 0-C 8
(4)      Discharge-- Discharge output sends out a signal, and the corresponding O3 relay is closed. After the
         delay of t5, the discharge output signal is cancelled, and the corresponding O3 relay is switched off.
         A complete control procedure is finished.
 Note:
   1.    During the above process, if the slow subtraction lead value is bigger than the quick subtraction lead
         value, i.e. C>b, the slow subtraction output won’t give out signal, and the corresponding O2 relay
         maintains switched off.   If no gradual feed is set for parameters, the above gradual feed process (3)
         is not included.
   2.    When the residual weight doesn’t reach to the batching value, the indicator stops subtraction, and
         wait for feed signal. After receiving feed signal, the indicator starts to feed material, and make
         judgment to the weight during feeding process. When the batching value is obtained, material
         feeding is stopped. At this moment, the weight can finish a subtraction cycle, then material
         subtraction is continued. For example, if the batching value is 50Kg, when the remaining material in
         the hopper is only 20kg, no subtraction will be performed until the hopper is added with material up
         to 50Kg.
   3.    The discharge process in the subtracting scale can be used to remove the container loaded with
                                                     23
                                   X K 3 1 9 0-C 8
          material, just like a discharge process.
Note: A—batching value of material 1; b—lead value of material 1; P—batching value of material 2; d—lead
value of material 2; L—zero zone value.
t0—measurement delay;t1—feed over delay of material 1;t2—feed over delay of material 2;t3—gradual feed
output time; t4-interval time of gradual feed; t5-discharge over delay time.
       The control procedure in the above diagram is composed of 5 processes including feed of material 1,
gradual feed out-of-allowance treatment of material 1, feed of material 2, gradual feed out-of-allowance
treatment of material 2 and discharge.
(1)       Feed of material 1-- When the control procedure starts, the feed output of material 1 gives out a
          signal, and the corresponding O1 relay is closed. When the weight is added to the feed stop value of
          material 1 A-b, the feed output signal of material 1 is cancelled; the corresponding O1 relay is
          switched off.
                                                     24
                                       X K 3 1 9 0-C 8
    (2)       Gradual feed out-of-allowance treatment of material 1-- After the delay for a period of t1 (feed over
              delay of material 1), if the parameter is set with gradual feed, the O2 relay corresponding to feed of
              material 1 will be closed for a period of t3, and switched off for a period of t4. Gradual feed is
              carried out through such repeated cycle, until the weight reaches up to the allowance range of
              batching value of material 1, i.e. the qualified area.
    (3)       Feed of material 2-- The feed output of material 2 gives out a signal, and the corresponding O1 relay
              is closed. When the weight is added to the feed stop value of material 2 P-d, the feed output signal of
              material 2 is cancelled, the corresponding O1 relay is switched off
    (4)       Gradual feed out-of-allowance treatment of material 2 -- After the delay for a period of t2 (feed over
              delay of material 2), if the parameter is set with gradual feed, the O2 relay corresponding to feed of
              material 2 will be closed for a period of t3, and switched off for a period of t4. Gradual feed is
              carried out through such repeated cycle, until the weight reaches up to the allowance range of
              batching value of material 2, i.e. the qualified area.
    (5)       Discharge -- Discharge output sends out a signal, and the corresponding O3 relay is closed. After the
              weight is less than the value L in zero zone, the discharged is considered completed, which
              corresponds to point M in the figure. At this moment, after another delay of t5, the discharge output
              signal is cancelled, and the corresponding O3 relay is switched off. A complete control procedure is
              finished.
          Note: If no gradual feed is set for parameters, the above gradual feed process (2), (4) is not included.
                                                            25
                                   X K 3 1 9 0-C 8
Parameters   Indicator display Parameters instructions                    Remark
                                                          26
                                       X K 3 1 9 0-C 8
      Brief description of control process(please understand in combination with the time sequence
diagram):
(1)      The indicator is put into operation and judge if the weight is bigger than the value in zero zone. If so,
         t0 delay is started, waiting for cargo to be loaded on the weighing platform.
(2)      The time t0 is over, and starts to calculate the average weight of cargoes, with time duration of t1.
         The value obtained from calculation serves as foundation for later catchweighing signal.
(3)      The time t1 is over, t2 delay starts, waiting for the cargo to be unloaded from the weighing platform.
(4)      The time t2 is over, and the catchweiging channel signal is sent, to make the cargo enter into the
         corresponding channel. The time for sending channel signal is t3.
(5)      The time t3 is over, and signal is sent, and the indicator judges once again if the weight returns to
         zero zone. The next cycle can’t be started only when the weight stays within zero zone.
2. External mode of catchweigher
Application example:
     It is assumed that high speed catchweigher is used at site: the industrial control PLC together with this
indicator performs quick catchweighing to the cargo. PLC controls the transportation of cargo to the weighing
platform, and gives out a trigger signal to the indicator when it reaches there to make it calculate the weight.
The weight range of the qualified product of user is between 9.90Kg~10.10Kg. Channel signal is sent as per
weight, to make the PLC control and send to different channels. About 3-5 seconds is taken during 1 cycle.
The indicator and PLC should coordinate well. We can set the parameters in 【SET--2】according to the
following table (2-digit decimal is assumed during calibration).
Param
      Indicator display Parameter setting                          Setting instruction
eter
                                                      27
                                   X K 3 1 9 0-C 8
    Brief description of control process(please understand in combination with the time sequence diagram)
(1)       The indicators starts to run, waiting for trigger signal;
(2)       The trigger signal is received, t0 delay occurs, waiting for cargo to be loaded stable.
(3)       The time t0 is over; the indicator starts to calculate the average weight of cargo, with time duration
          of t1. The value obtained from calculation serves as foundation for later catchweighing signal
(4)       The time t1 is over, waiting for activation of t2.
(5)       The time t2 is over, the channel signal for catchweighing is sent to make the cargo enter into
          corresponding channels. The time for sending channel signal is t3.
(6)       The time t3 is over, and the signal is sent and the indicator judges once again if the weight returns to
          zero zone. The next cycle can’t be started only when the weight stays within zero zone
      After setting the upper and lower limit value, the instruction under operation will send real time the signal
at the output end according to the actual weight.
                                                       28
                              X K 3 1 9 0-C 8
                         Annex 1 Error Message Prompt
Err P The baud rate setting does not meet requirements during printing
                                                    29
                               X K 3 1 9 0-C 8
 Annex 2 Large Screen Data Waveform Diagram and Format
1. The large screen signal is the 20mA constant current loop signal, with binary code serial output, and
    baud rate of 600. Every frame of data has 11 bits, including 1 start bit (0), 8 data bits (low-order bit in
    front), 1 flag bit, and 1 stop bit (1).
2. A set of data is set every 100ms. Every set of data includes 3 frames of data, with meaning as follows:
                                                  30
                                  X K 3 1 9 0-C 8
                                                 31
                                   X K 3 1 9 0-C 8
        Annex 3 Serial Communication-Data Format of Command
                           Response Mode
AD: indicator address(for example: A(ASCII code is41))
XH: check high four-bit;
XL: check low four-bit.
Note:
(1) The address is 1~26 when setting the indicator, and the corresponding address during communication
         is A~Z;
(2) The command A~H is also sent in ASCII format.
Please refer to the following table in respect of the meaning of various letter command and their
communication format:
        Command               Meaning                      Format                        Example
        Send by PC           Handshake        02 AD 41 XH XL 03             02 41 41 30 30 03
 A      Send         by                       02 AD 61 XH XL 03             02 41 61 32 30 03
                             Handshake
        indicator
        Send by PC        Read gross weight   02 AD 42 XH XL 03             02 41 42 30 33 03
 B      Send         by                       02 AD 62 ** ** ** ** ** **    02 41 62 2B 30 30 31 2E 30 30
                          Send gross weight
        indicator                             ** ** XH XL 03                30 32 37 03(1.000)
        Send by PC         Ret net weight     02 AD 43 XH XL 03             02 41 43 30 32 03
 C      Send         by                       02 AD 63 ** ** ** ** ** **    02 41 63 2B 30 30 30 2E 30 30
                           Send net weight
        indicator                             ** ** XH XL 03                30 32 37 03(0.000)
        Send by PC            Read tare       02 AD 44 XH XL 03             02 41 44 30 35 03
 D      Send         by                       02 AD 64 ** ** ** ** ** **    02 41 64 2B 30 30 31 2E 30 30
                              Send tare
        indicator                             ** ** XH XL 03                30 32 31 03(1.000)
        Send by PC              Tare          02 AD 45 XH XL 03             02 41 45 30 34 03
 E      Send         by                       02 AD 65 XH XL 03             02 41 65 32 34 03
                                Tare
        indicator
        Send by PC          Zero setting      02 AD 46 XH XL 03             02 41 46 30 37 03
                                              Zero setting successful:      Zero setting successful:
                                              02 AD 66 XH XL 03             02 41 66 32 37 03
 F      Send         by
                            Zero setting      Zero setting conditions not   Zero setting conditions not
        indicator
                                              satisfied:                    satisfied:
                                              02 AD 69 XH XL 03             02 41 69 32 38 03
        Send by PC             Startup        02 AD 47 XH XL 03             02 41 47 30 36 03
 G      Send         by                       02 AD 67 XH XL 03             02 41 67 32 36 03
                              Startup
        indicator
        Send by PC              Stop          02 AD 48 XH XL 03             02 41 48 30 39 03
 H      Send         by                       02 AD 68 XH XL 03             02 41 68 32 39 03
                                Stop
        indicator
                                                           32
X K 3 1 9 0-C 8
33