HSE Observation Report: S. No Location Issues Photograph Action Required / Recommendations Rectification Close Out Photo

1) The HSE observation report documents 11 issues found at various locations on site including missing tag lines during lifting, unsecured floor openings, expired crane certificates, damaged power tools without inspections, lack of an ambulance on site, improper PPE, cigarette butts in non-smoking areas, unsafe ladder use, poor illumination and housekeeping. 2) For each issue, the report recommends actions for the contractor to rectify the problems including ensuring tag lines and floor openings are properly secured, cranes hold valid certificates, all power tools are inspected and color coded, an ambulance is available, proper PPE is worn, smoking rules are enforced, ladder safety training is provided, and illumination and housekeeping are

Uploaded by

faisal nadeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (6 votes)
9K views3 pages

HSE Observation Report: S. No Location Issues Photograph Action Required / Recommendations Rectification Close Out Photo

1) The HSE observation report documents 11 issues found at various locations on site including missing tag lines during lifting, unsecured floor openings, expired crane certificates, damaged power tools without inspections, lack of an ambulance on site, improper PPE, cigarette butts in non-smoking areas, unsafe ladder use, poor illumination and housekeeping. 2) For each issue, the report recommends actions for the contractor to rectify the problems including ensuring tag lines and floor openings are properly secured, cranes hold valid certificates, all power tools are inspected and color coded, an ambulance is available, proper PPE is worn, smoking rules are enforced, ladder safety training is provided, and illumination and housekeeping are

Uploaded by

faisal nadeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

HSE Observation Report

Date: 4-6-2020
Action required /
S. No Location Issues Photograph Rectification Close Out Photo
Recommendations

Contractor need to ensure


Found and Observed that tag line should be
Tower Tag line was available to control the
1
Crane- 3 missing during the movement and ration of the
lifting ( repeated) load

Contractor need to ensure


that Openings must be
closed properly with the
Found and Observed
2 A05 & A02 unsecured floor suitable material , Warning
opening signs must be in place to
notify the workers of the
hazard

Found that Tower Contractor must ensure that


Tower Crane-2 , 3rd Party all tower cranes must hold
3 Crane-2 certificate was valid 3rd party certificate
expired

4 Found and Contractor need to ensure


Observed damaged that, All power tools must
cable power tool and be in a good condition,
Ground Floor without monthly
inspected prior to use by a
A02 inspection color
code competent person and color
HSE Observation Report

Action required /
S. No Location Issues Photograph Rectification Close Out Photo
Recommendations
code must be in place

Contractor must ensure that


Found and Observed
all power tools are inspected
5 Ground Floor power tool plug’s
were not installed prior to use by a competent
A02
properly person.

Contractor need to ensure


Observed that that emergency vehicle
Basement-1 emergency vehicle (ambulance) is available on
6
( Ambulance ) not site to respond to any
available on site medical emergencies

Contractor need to ensure


Found and Observed
7 without proper PPE that all persons should wear
Water Tank
on Site mandatory PPE

Contractor need to strictly


instruct their Manpower to
Found and
8 Basement-1 Observed cigarette smoking is not allowed in
butts at rest area non-designated area, it’s
strictly prohibited.
HSE Observation Report

Action required /
S. No Location Issues Photograph Rectification Close Out Photo
Recommendations

Contractor need to conduct


Found an operative
awareness training to the
9 Ground Floor was standing on the
ladder without any workers regarding Ladder
A02
support. Safety

Observed Poor Contractor need to ensure


illumination due to
that all access/egress and
electrical
10 Maintenance at staircase are well
Basement-1 basement, from stair illuminated. emergency
Mess hall access to the mess light must be installed.
hall

Observed Poor
Housekeeping at Contractor need to
Basement-1 and maintained a good
11 A05 & A05 several places in housekeeping all over the
the building building premises
premises ( A05 & (A02&A05)
A02 )
Prepared by:
Mohammed Vajid Ali