0% found this document useful (0 votes)
116 views2 pages

Fluke 115: Multimeter

The Fluke 115 multimeter is a compact true-rms multimeter for field service technicians. It measures voltage, current, resistance, frequency, capacitance and more. It has features like one-handed operation, large backlight, min/max recording, and CAT III 600V safety rating.

Uploaded by

gokulraje
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
116 views2 pages

Fluke 115: Multimeter

The Fluke 115 multimeter is a compact true-rms multimeter for field service technicians. It measures voltage, current, resistance, frequency, capacitance and more. It has features like one-handed operation, large backlight, min/max recording, and CAT III 600V safety rating.

Uploaded by

gokulraje
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Fluke 115

Multimeter
Technical Data

Compact true-rms meter for


field service technicians
The Fluke 115 is the solution for a wide
variety of electrical and electronic test-
ing applications. This true-rms meter
provides easy one-handed operation in
a compact package.

Features include:
• Resistance, continuity, frequency, capacitance, and diode test
• Measures 10 A (20 A overload for 30 seconds)
• Large white LED backlight to work in poorly lit areas
• Compact ergonomic design for one-handed operation
• Compatible with optional magnetic hanger (ToolPak™)
• True-rms for accurate measurements on non-linear loads
• Min/Max/Average with elapsed time to record signal
fluctuations
• CAT III 600 V safety rated

General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 90 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )
Maximum voltage between any 600 V
terminal and earth ground
Surge protection 6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse
(Fluke PN 803293)
Actual size
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery 9 volt Alkaline, NEDA 1604A/
IEC 6LR61
Battery life 400 hours typical, without backlight

N10140
R
Accuracy specifications
Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
Ordering
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 information
DC volts 6.000 V 0.001 V
60.00 V 0.01 V 0.5 % + 2 Fluke-115 Multimeter
600.0 V 0.1 V Included
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
TL75 Test leads, holster, User’s
4.0 % + 3 (500 Hz to 1 kHz) manual and 9 V battery (installed).
AC millivolts1 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
true-rms 2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms 6.000 V 0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
60.00 V 0.01 V
2.0 % + 3 (500 Hz to 1 kHz)
600.0 V 0.1 V
Continuity 600 Ω 1Ω Beeper on < 20 Ω off > 250 Ω; detects
opens or shorts of 500 µs or longer.
Ohms 600.0 Ω 0.1 Ω 0.9 % + 2
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ
0.9 % + 1
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
40.00 MΩ 0.01 MΩ 5%+2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF 1 nF
10.00 µF 0.01 µF 1.9 % + 2
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF 1.9 % + 2
> 1000 µF 5 % + 20
Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms 6.000 A 0.001 A
(45 Hz to 500 Hz) 1.5 % + 3
10.00 A 0.01 A
20 A overload for 30 seconds max.
DC amps 6.000 A 0.001 A
1.0 % + 3 Fluke. Keeping your world
10.00 A 0.01 A up and running.™
20 A overload for 30 seconds max.
Hz (V or A input)2 99.99 Hz 0.01 Hz Fluke Corporation
PO Box 9090, Everett, WA USA 98206
999.9 Hz 0.1 Hz Fluke Europe B.V.
0.1 % + 2
9.999 kHz 0.001 kHz PO Box 1186, 5602 BD
Eindhoven, The Netherlands
50.00 kHz 0.01 kHz For more information call:
Notes: In the U.S.A. (800) 443-5853 or
1 All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, Fax (425) 446-5116
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected In Europe/M-East/Africa (31 40) 2 675 200 or
from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full Fax (31 40) 2 675 222
scale. AC volts is ac coupled and ac mV is dc coupled. In Canada (800)-36-FLUKE or
2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006-2009 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 2/2009 2634043 D-EN-N Rev C