This document provides specifications for the F800 ALL IN ONE TYPE WEIGHING CONTROLLER. It has the following key features: 1) It is a full-scale weighing controller developed for measuring systems with high speed 100 times/sec A/D conversion and powerful digital processing. 2) It can store setting values in 100 different codes for convenient code selection and measuring. 3) It has excellent operability with function-prioritized key input and a large vacuum fluorescent display. 4) It allows direct connection to PLCs and has DeviceNet and CC-Link interfaces.

Uploaded by

Isah Emmanuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views1 page

Weighing Controller Specs

This document provides specifications for the F800 ALL IN ONE TYPE WEIGHING CONTROLLER. It has the following key features: 1) It is a full-scale weighing controller developed for measuring systems with high speed 100 times/sec A/D conversion and powerful digital processing. 2) It can store setting values in 100 different codes for convenient code selection and measuring. 3) It has excellent operability with function-prioritized key input and a large vacuum fluorescent display. 4) It allows direct connection to PLCs and has DeviceNet and CC-Link interfaces.

Uploaded by

Isah Emmanuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

F800 ALL IN ONE TYPE WEIGHING CONTROLLER

Specification
Excitation voltage DC10V±5% Output current : within 120mA
ANALOG
Remote sense type (up to 4 units of 350 loadcells can be
connected in parallel)
Zero adjustment range 0ޯapprox. 2mV/V
Rough adjustment : Digitally controlled via rough adjustment circuit.
Fine adjustment : Automatic adjustment via digital processing.
Span adjustment range 0.3ޯ2.0mV/V
Rough adjustment : Digitally controlled via rough adjustment circuit.
Fine adjustment : Automatic adjustment via digital processing.
Min. input sensitivity 0.3μV/count
Accuracy Non-linearity...... within 0.01%/FS (Typ 0.005%/FS at room temperature)
Zero drift............ within 0.1μV/℃ RTI (Typ 0.08 μV/℃)
Gain drift............within 15ppm/℃ (Typ 5ppm/℃)
Noise..................within 0.1μVp-p RTI (0.1ޯ10Hz)
Analog filter Bessel type low-pass filter (-12dB/oct.)
Selectable at 2, 4, 6, 8 Hz
A/D Speed ...........................100 times/sec (10mS)
converter Resolution .....................16bit (binary)
DISPLAY Display unit Eight (8) digits, 12mm Original Vacuum Fluorescent Display

Display 5 digits Signs: Minus sign on most significant digit

Unit Selectable at g, kg, t, N, none

Display frequency Selectable at 3, 6, 13, 25 times/sec. (internal 100 times/sec.)

Status display SET / LOCK / HOLD / Z.ALM / STAB. / TARE / NET / GROSS /
RUN / HI / LO / NEAR Z. / SP1 / SP2 / SP3 / OVER / GO / UNDER
/ COMPL / D.CHG / AFC

Set value display CODE / FINAL /OVER / UNDER / SP1 / SP2 / CPS
● A full-scale weighing controller developed exclusively for SETTING Setting items ・Calibration ........ Zero Calibration / Span Calibration / Balance Weight Value /
measuring system. Capacity / Min. Scale Division / Over Net / Over Gross / Display
Frequency / Decimal Point / 1/4 Scale Display On/Off / Unit /
● High speed A/D conversion and powerful digital processing gravitational acceleration compensation
・Comparative .....SP1 / SP2 / CPS / Final / Under / Over / AFF Reg / Compensation
capabilities of 100times/sec., for rapid response to input setting 1
Input Timer (These items preset according to 100 individual
signal. codes.)
・Comparative .....Near Zero / Lo / Hi / Preset Tare Weight / Comparison Inhibit
● Set ting values c an be stored in each of the 10 0 kinds setting 2
Time / Judging Time / Complete Time / Discharging Time / AZ
times / Judging times / Sequence mode
of codes so that code selection and measuring can be ・Function............ Digital Filter / Motion Detection / Weighing Function 1 / Weighing
conveniently performed. setting Function 2 / Weighing Function 3 / Function Key Inhibited /
RS-232C / ID Number Setting / Analog filter / Zero tracking /
● Excellent operability. Measurement Law / Extended function selection
Function-prioritized key input and Vacuum Fluorescent EXTERNAL External output Near zero / SP1 / SP2 / SP3 / under / go / over / complete /
SIGNAL signal (16) discharge / Lo / Hi / stable / weight error / error / final error / RUN
Display (VFD) tube for improved visibility. Transistor open collector output (Emitter = COM terminal)
Output is set to LO when transistor is ON.
● Direct PLC connection Vceo = 30 V (max), Ic = 120mA (max)

DeviceNet and CC-Link interface. External input Gross or net / digital zero / tare on / tare reset / hold or judge / feed
signal (23) or discharge / accumulation command / accumulation clear / code
● High display resolution setting / start / stop / discharge command / compulsory discharge
command / discharge gate open / discharge gate close / code
1/10000 resolution at all input range is assured. assign selection
Set to ON when shorted to COM terminal through contact point
(relay, switch etc.) or non-contact point (transistor, open collector
output such as TTL etc.) Ic=10mA or lower
External Dimension INTERFACE ・ SIF : 2-wire type serial interface
・ SI2 : 2-wire high speed bidirection serial interface (option)
(Front View) (Side View) ・ 232 : RS-232C Communication Interface (option)
・ BCO : BCD Parallel Data output Interface (option)
・ BCI : BCD Parallel Data Input Interface (option)
・ 485 : RS-485 Communication Interface (option)
・ DAC : D/A Converter Interface (option)
・ ODN : DeviceNet Interface (option)
・ CCL : CC-Link Interface (option)
・ TLK : T-LINK Interface (option)
Please inquire from our sales office for the combination of options that can be installed.

GENERAL Power supply voltage AC85ޯ110V, 102ޯ132V, 170ޯ220V, 187ޯ242V


SPECIFICATIONS (Please specify when ordering) 50/60Hz
Power consumption Approx. 20VA
Operation condition Temperature : Operation temperature : −10ޯ+40℃
Storage temperature : −40ޯ+80℃
Humidity : < 85% RH (non-condensing)
External dimension 130(W)×207(H)×150(D)mm (not including protrusions)

(Rear View) Weight Approx. 3kg


ATTACHMENTS AC input cord (Nominal rating 125V) 2m.. 1 BCD output connector
Spare fuse (1A) ....................................1 (when BCD output option is selected) ..............................................1
Mini driver ............................................. 1 BCD input connector
Loadcell connector (JRC connector) .....1 (when BCD input option is selected) ................................................ 1
57 series 50p connector ........................1 DeviceNet connector (when DeviceNet option is selected).. 1
Operation Manual ..................................1 CC-Link connector (when CC-Link option is selected) ..........1
Panel cutPanel cut dimension
dimension
OPTIONAL CAAC2P-P2 : AC input cord 2m
ACCESSORIES CAAC3P-CEE7/7-P1.5 : AC input cord (voltage resistance: 250V) 1.5m
CA4131 : (6-wired) cable with JRC connector at one end 3m
CA4230 : JRC-PRC (6-wired) conversion relay cable 0.3m
CN3P-2P : 3P-2P converter plug for AC input cord
CA4311 : JRC-PRC(6-wired)conversion relay cable 1m(4-wired to 6-wired)(for 520A)
CN21 : BCD input/ output connector
CN22 : 57 series 50p connector for external input/output
Unit mm CN35 : D-sub25p connector for RS-232C
CN71 : CC-Link connector
CND01 : DeviceNet connector