2
NOTE
(1) The unauthorized copying of some or all of this manual is prohibited.
(2) The information contained herein is subject to change without notice.
(3) If there are any questions such as wrong or missing parts of the contents
    listed in this manual, please contact us.
(4) To improve the product performance, functions can be changed with no
    notice.
(5) Please understand that CAS does not have responsibility for a demand
    related to loss, lost profit etc. caused by operating the product, regardless
    of the third clause.
               This is warning & caution mark
               This is hazard alert mark
               This is useful information mark
                                       3
                                             CONTENTS
1. Precautions....................................................5
2. Main Features...............................................5
3. Technical Specifications ..............................6
4. Description of Panels and Symbols ...........7
5. Installation.....................................................8
6. General Functions......................................11
7. Test Mode.....................................................12
8. Setting Mode ...............................................13
9. Infrared Remote Controller .....................16
10. Wireless Specification..............................16
11. RS-232C Interface....................................17
12. Real Time Clock.......................................18
13. Wireless Pairing........................................19
14. Check Message .........................................20
                 4
1. Precautions
     Please be informed that we’re not responsible for any incident or
mishap caused by partial modification of this product.
To avoid such situation, customers need to contact our customer
service team or system installation staff in advance, and any
modification should be conducted under our surveillance.
 Do not connect incompatible adaptor.
    Use only adaptor approved by CAS for use with this particular model.
    The use of any other types may invalidate any approval or warranty, and may be dangerous.
    For availability of approved enhancements, please check with your dealer.
 Don’t install the CRD-F series in direct sunlight.
 Avoid sudden temperature changes, vibration, wind, water or dirt.
 Avoid from the shock of excessive weight.
 Place the scale away from water.
 Use away from heavy R.F noise.
 Do not disassemble or modify this product.
2. Main Features
 Water proof: IP65
 ZigBee wireless communication
   Interface with crane scale & wheel load scale & indicator
   Standard remote control
   Tilt and swivel mount bracket
   Touch key
                                                     5
3. Technical Specifications
◆   General specifications
Display              2300F: FND (2.3 inch) / 3000F: FND (3 inch)
Display lamp         Zero, Tare, Hold, Stable, Power
Touch key            Zero, Tare, Hold, Power
Case material        Engineering plastic
Temperature range    -20℃ ~ 60℃
Product weight       2300F: Approx. 1.5kg / 3000F: Approx. 2.2kg
Adaptor              12V     1A
Option 1 (OP-01)     RS232C, RTC(Real time clock), 2solid state relays and 4inputs
Option 2 (OP-02)     Use the vehicle power (12~24V )
◆   Product size
    1) CRD-2300F
    2) CRD-3000F
                                           6
4. Description of Panels and Symbols
                                     DISPLAY
              Displays weight or messages
              Indicates that the weight to be in stable condition
 ZERO lamp    Indicates that scale is stable and at zero
 Kg/lb lamp   Unit conversion operating lamp
 TARE lamp    Indicates that scale is currently using a tare
 Power lamp   Power lamp
    kg lb     Indicates the weighing unit
                                   KEYBOARD
              Turn on and off the product
              Return the display to zero
              Used to change unit
              Used to weigh an item by using the container
                                        7
5. Installation
12V         Power adaptor + (RED)
GND         Power adaptor – (BLACK)
TX3         Not used (Extra RS232C TXD)
RX3         Not used (Extra RS232C RXD)
GND         Not used (Extra RS232C GND)
                           8
RX1
        Not used
GND
TX2     RS232C TXD (OP-01)
RX2     RS232C RXD (OP-01)
GND     RS232C GND (OP-01)
EX+
EX-
SIG+    Not used
SIG-
GNG
POWER
ZERO    External key 4 contact / 4inputs (OP-01)
TARE       “HOLD” mark is the same as “kg/lb”
HOLD
GND
EVCC+
OUT1
        2 solid state relays contact (OP-01)
EVCC+
OUT2
                            9
1) External input circuit
    External inputs are interlocked with the touch keys.
2) Solid state relay circuit
  Maximum load (AC, DC 350V /130mA)
  Output conditions
            Output                              Conditions
     OUT2 ON (low limit)            Low limit< Measured value ≤ High limit
     OUT1 ON (high limit)                High limit < Measured value
         OUT1,2 OFF                      Measured value ≤ Low limit
                                  10
6. General Function
6.1. Zero function
Use to correct drifted zero value when the scale is unloaded, and motion is not detected.
This function works when ZERO KEY is pressed, and the ZERO LAMP is on.
6.2. Setting Tare Weight Function
Press the TARE KEY. Then, the scale will memorize the weight of the tare and will display
zero value “0”kg. The TARE LAMP will be on.
To escape this function, remove everything from the scale, and press the TARE KEY.
Then, the TARE LAMP will be off and this function is terminated.
6.3. Hold Function
   This function will only work with IR remote control.
   Also, F08 of CCB setting mode must be set to 4.
■ Automatic hold
- Press * KEY when the scale is empty (Initial zero state).
- The weight display will indicate            . HOLD LAMP is on.
- After loading a thing, if the weight turns stable then, a display shows      and
 average weight will appear.
- The weight of a loaded thing is displayed.
- To escape the automatic hold mode, when zero point is on, press * KEY.
 Then, the message of                is displayed and HOLD LAMP is off and normal weighing
 mode is reverted.
■ Manual hold
- Press * KEY loading a thing.
- This message of          is displayed and sequentially the message of        is
  shown with appearing the average weight.
- The weight of a loaded thing is displayed.
- To escape the manual hold mode, remove everything from a hook, or press the * KEY.
  Then, HOLD LAMP will be off and the scale changes from a hold mode to a normal mode.
                                           11
7. Test Mode
(1) How to enter this mode
Press the ON KEY to power on and immediately press ZERO KEY to enter test mode.
(2) Testing Menu (TEST 1- TEST 2)
■ TEST 1 : Keyboard Test
         Remote
 Key                       Display                          Description
         Control
                                           Press a keyboard that you want to test, and
                                           then the display message will be shown.
                                           If press a TARE KEY, move on TEST 2.
■ TEST 2 : Display Test
       Display                                   Description
                      TEST 2 runs off automatically and a display is on.
                      If press the TARE KEY, move on normal mode
                                     12
8. Setting Mode
8.1. How to enter this mode
Press the ON KEY to power on and immediately press TARE KEY.
And press the TARE KEY again.
8.2. Keyboard
■     : Use to set up an initial zero value (0).
        (F12, F13: Used to move the input value to the left or right by one place)
■     : Use to add a value of “1” from existing value.
■     : Use to save an inputting value and to move on next menu.
8.3. Menus
■ F01: PC / Printer connection (0~2)
    Setting Menu                                    Description
        F01-0          Wireless
        F01-1          RS232C
        F01-2          Wireless & RS232C
    In case of F01-0/2, you used the CRC-200 (Wireless dongle)
     Weighing data will be sent by according to set in F02.
■ F02: Function * key (Remote controller) (0~2)
    Setting Menu                                    Description
        F02-0          Operation is equal to the * key of the master
        F02-1          Send data command key (Print format)
        F02-2          Send data command key (22bytes format)
■ F03: Item number (Identification number of each item) (0~9)
    Setting Menu                                    Description
        F03-0          Item No.0
        F03-5          Item No.5
        F03-9          Item No.9
                                            13
■ F04: Print line feed (0~9)
   Setting Menu                                        Description
        F04-0             1 line feed
        F04-5             6 line feed
        F04-9             10 line feed
■ F05: Print form (0,1)
   Setting Menu                                        Description
        F05-0             Form 0 (weigh No., Item No., weight)
        F05-1             Form 1 (Serial No., Item No., weight)
   When the F02-1 is selected, this form is printed.
   The weigh No. is not saved.
[FORM 0]                                              [FORM 1]
  2014.10.13 12:00                                      2014.10.13 12:00
  001, ID_9,       25 lb                                SN_02, ID_9,     25 lb
■ F06: Initialization of serial number (0,1)
   Setting Menu                                        Description
        F06-0             Maintain current number
        F06-1             Initialization (starting from No.1)
■ F07: Auto transmit at stable (0~2)
   Setting Menu                                        Description
        F07-0             Not used
        F07-1             Send data at stable (Print format)
        F07-2             Send data at stable (22bytes format)
■ F08: Auto transmit at data hold (0,1)
   Setting Menu                                        Description
        F08-0             Not used
        F08-1             used
   The hold data will be sent by according to set in F07.
                                            14
■ F09: Wireless connection of other company’s product (0~2)
   Setting Menu                                    Description
       F09-0           Not used
       F09-1           Product with 22bytes RS232C format
       F09-2           Product with 18bytes RS232C format
   If you select F09-1 or F09-2, you must use the CRC-200 dongle at the scale.
■ F10: RS232C Stream mode (0,1)
   Setting Menu                                    Description
       F10-0           Not used
       F10-1           Stream mode
■ F11: High limit (not included weighing points)
   Setting Menu                                    Description
         200           20.0 lb (In case of one decimal point)
■ F12: Low limit (not included weighing points)
   Setting Menu                                    Description
         100           10.0 lb (In case of one decimal point)
                                           15
9. Infrared Remote Controller
9.1. How to use
                  ■     : Use to power on/off the CRD-F series
                  ■     : Same as keyboard of CRD-F series
                  ■     : Same as keyboard of CRD-F series
                  ■     : Same as keyboard of CRD-F series
                  ■     : Same as keyboard of CCB crane scale
                  ■       : Used to add weights.
                  If press a SUM KEY, the sum of weights is displayed.
                  After that, about 2 sec later, a weighing mode is reverted.
                  Weight of less than 5 digits is not summed.
                  Maximum of sum weights is 99999, and if it exceeds
                  the weights is initialized to zero.
9.2. Specification
 List                          Description
 Available Distance            6 m ~ 10 m
 Available Angle               60°
 Power                         3V (1.5V AA 2 EA)
10. Wireless Specification
 RF frequency range                  2400 ~ 2483.5 MHz
 Output power                        Max. 4dBm
 Channel width                       2 MHz
 Frequency offset                    < ±30ppm
 Transmit data rate                  250Kbps,500Kbps
 Receiver sensitivity                -99dBm (PER <1%)
 Maximum input level                 0dBm
 RF In/out impedance                 50 ohm (TXRF, RXRF)
 Spurious(2nd harmonics)             < -30dBm
 Radio link effective range          Approx. 100M (Open space)
                                        16
11. RS-232C Interface
1) Type : EIA-RS-232C
2) Method : Full-duplex, asynchronous transmission Format
① Baud rate: 9600 bps
② Data bit: 8 bits
③ Code : ASCII
3) Format (22bytes)
Header 1      Header 2        ID                Data                 Unit       Terminator
 S    T      , G S        ,            ,                 0   .   0          l     b    CR    LF
                         Lamp status
                     ST      Stable weight data (0x53) (0x54)
                     US      Unstable weight data (0x55) (0x53)
  Header 1
                     OL      Overload (0x4F) (0x4C)
                    HD       Hold weight data (0x48) (0x44)
                    GS       Gross data (0x47) (0x53)
  Header 2
                     NT      Net data (0x4E) (0x54)
       ID          Command address ID is selected in F02 (If ID is 1, 0x31 is sent)
     Lamp          Bit7     Bit6    Bit5 Bit4              Bit3       Bit2    Bit1 Bit0
     status         1      Stable     1      Hold            1         Net    Tare Zero
                   Example 1) 13.5 lb ‘ ’, ‘ ’, ‘ ’, ‘ ’, ‘1’, ‘3’, ‘.’, ‘5’
     Data          Example 2) 135 lb ‘ ’, ‘ ’, ‘ ’, ‘ ’, ‘1’, ‘3’, ‘5’, ‘ ’
                   Example 3) -13.5 lb ‘-’, ‘ ’, ‘ ’, ‘ ’, ‘1’, ‘3’, ‘5’, ‘ ’
                      Kg        (0x6B) (0x67)
      Unit             g        (0x20) (0x67)
                       lb       (0x6C) (0x62)
 Terminator          CR LF      (0x0D) (0x0A)
                                           17
12. Real Time Clock
1) How to enter this mode
Press the ON KEY to power on and immediately press kg/lb KEY.
And press the TARE KEY.
2) Keyboard
   : Used to increase the setting constant one by one.
   : Used to move the input value to the left or right by one place.
   : Used to save the value and to move next menu.
  Display                                     Description
             Year input readiness.
             Modify the year by pressing the numerical keys and press TARE KEY
             Month & date input readiness.
             Modify the date by pressing the numerical keys and press TARE KEY
             Time input readiness.
             Modify the time by pressing the numerical keys and press TARE KEY
             The end
                                        18
13. Wireless Pairing
 Step                         Operation & Description
        How to enter the pairing mode
        1) CCB crane scale
        When the display is off, press ON/OFF key while pressing * key.
        When “ =      ”(Firmware version) is displayed, press kg/lb key.
        Then, “       ” is displayed.
        2) CRD-F wireless display
        Press the ON/OFF key to power on and immediately press kg/lb key.
        And press the kg/lb key again.
  1
        Then, “       ” is displayed.
        3) CRC-100 controller
        When the display is off, press ON/OFF key while pressing ENTER key.
        When “ =      ”(Firmware version) is displayed, press3 key.
        Then, “       ” is displayed.
        4) CRC-200 wireless dongle
        Press the SET KEY for the 5 seconds with the power on that connected.
        Then, the green light is blinking.
        Pairing
        When “         ” is displayed at both products, if you press * key of CCB
        crane scale, pairing will finish.
  2
            Please check “     ” message at both products.
            If ending message is not appear, please repeat the pairing.
                                       19
14. Check Message
When a thing is over-weighed within the maximum weight value, the error message
is displayed.
Do not weigh the thing whose the limit of a maximum weight value is exceeded.
If a load cell is broken, then the load cell has to be replaced.
Something wrong in a Load cell connection or in an A/D conversion.
Please contact us to resolve this technical problem.
              ☞               ☞                ☞                ☞
When the scale and CRD-F series does not communicate, this is displayed.
Confirm radio link effective range.
                                      20
MEMO
21
MEMO
22
23