Esdc Row
Esdc Row
MANHOLE
TEMPORARY
OFFICE FOR ESDC SAMPLE
& ROW ROOM
MPCALA OFFICE
IC-DPWH-DESIGNER'S
OFFICE
ENTRY
EXIT
SERVICE
ENTRANCE
BASKETBALL AREA
PARKING AREA
WAREHOUSE DRIVERS GENSET
OFFICE TYPE EF LOUNGE
TYPE
BOOSTER
TANK
TIN NO.
1 2 3 4 1 2 3 4 A B C
W
B TOP OF CEILING
W W
2 2 1
A TOP OF CEILING
W
2
W
2
W
1 FINISH FLOOR LEVEL
FINISH FLOOR LEVEL GROUND LINE
A A GROUND LINE
LEFT-SIDE ELEVATION
SCALE 1: 100 MTS
FRONT ELEVATION
SCALE 1: 100 MTS
B
W W
2 2
C B A
C
W
B
1
4 3 2 1
TOP OF CEILING
TOP OF CEILING
ESDC, ROW FLOOR PLAN FINISH FLOOR LEVEL
SCALE 1: 100 MTS
GROUND LINE
W W W
1 2 2
RIGHT-SIDE ELEVATION
SCALE 1: 100 MTS
REAR ELEVATION
SCALE 1: 100 MTS
FFL
TYPE/NAME : D2/ FIBERBOARD FLUSH TYPE/NAME : W1/ ALUMINUM ANODIZED TYPE/NAME : W2/ ALUMINUM ANODIZED
DOOR SLIDING WINDOW SLIDING WINDOW
DESCRIPTION: 6mm FIBERBOARD HIGH DESCRIPTION: 6mm THK. CLEAR DESCRIPTION: 6mm THK. CLEAR GLASS ON
DENSITY PLYWOOD, SINGLE RABBIT GLASS ON ANALOK ALUMINUM FRAME ANALOK ALUMINUM FRAME
WOOD JAMB
QUANTITY: 4
QUANTITY: 3
QUANTITY: 2
TIN NO.
1 2 3 4
A
SEE DETAIL 1
+.30m ON FILL
+.30m ON FILL
FOUNDATION PLAN
SCALE 1: 100 MTS
WALL FOOTING
TIN NO.
1 3 4
1 2 3 4
A
A
B
B
C
C
TIN NO.
1 2 3 4
EXISTING
MANHOLE
MDP-3
TEMPORARY A
OFFICE FOR ESDC SAMPLE
& ROW ROOM
MDP-2
MDP-4
MPCALA OFFICE
IC-DPWH-DESIGNER'S
OFFICE
ACU -1
ENTRY
EXIT
MDP-5
RETROFITTING:
BAR BUS EXTENSION
1 2 3 4 1 2 3 4
f f f
b b d d
f f f
b b d d
Sab Scd
B e e e
B
Sefg
e e e
C C
MDP-1
TIN NO.
GENERAL ELECTRICAL NOTES AND SPECIFICATIONS
2. ALL JUNCTION UTILITY, SQUARE AND PULL BOXES SHALL BE GAUGE #18 OR
APPROVED EQUIVALENT AND SHALL BE PAINTED WITH ONE COAT PRIMER
PRIOR TO INSTALLATION.
4. POWER SUPPLY SHALL BE 230 VOLTS, 3 PHASE, 60 HERTZ, THREE WIRE SYSTEM.
TIN NO.
1 2 3 4
W W
2 2 EXISTING
A MANHOLE
CO
CO
TCGI-ESDC DCCD-ESDC ROW OFFICE
LAV LAV
FD FD
B
WC WC OUTLET
W W
2 2
CO (TAP TO EXISTING
URI
CO
FD
LAV
WC
LAV
WC
FD
OUTLET
SEPTIC TANK STREET
DRAINAGE LINE)
C CO
URI
VSTR
SEPTIC TANK
VSTR
CO
VSTR 100mm DIA. PVC SOIL PIPE
1 2 3 4
A
W
2
W
2 FAU FAU
FAU FAU
B
W W
2 2
FAU FAU
TIN NO.
GENERAL NOTES AND PLUMBING SYMBOLS :
SPECIFICATIONS: FAU FAUCET SSP SOIL STACK PIPE
WC WATER CLOSET VSTR VENT STACK THRU ROOF
1. ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE WITH THE
RULES AND REGULATIONS OF THE LATEST EDITION OF THE LOCAL LAV LAVATORY GV GATE VALVE
PLUMBING CODES, ORDINANCES AND UNIFORM PLUMBING CODE. FD FLOOR DRAIN CV CHECK VALVE
3. ALL PIPING MATERIALS, WATER LINES, WASTE AND SOIL PIPES AND
FITTINGS SHALL BE OF APPROVED QUALITY AND TO BE TESTED FOR
LEAKS, BACKFLOW AND MALFUNCTION.
2400.00
SPACED @ INLET
0.20m O.C. OUTLET
PLAN
SECTION
CAD / DESIGN BY:
LOGO: ENGINEER: PROJECT TITLE / LOCATION:
SHEET CONTENTS: SCALE SHEET NO.
JDR-CE
DATE : 10-15-2020
TEMPORARY FIELD OFFICE FOR ESDC & ROW CHECKED BY: PLUMBING DETAILS
AS SHOWN
PRC NO. Validity: GENERAL NOTES
REVISIONS: SEPTIC TANK DETAILS
PTR NO. Date: LANGKAAN 2, DASMARINAS, PHILIPPINES
TIN NO.