HumaStar 100 | 200

The perfect choice for aspiring labs

> Robust design for optimal performance


> Proven - thousands of units in use worldwide
> Reliable results - perfect matching of reagents, calibrators and controls

Clinical Chemistry
CoreLab DX
HumaStar 100 | 200
Experience out of the ordinary

One concept – two instruments


> Random access clinical chemistry analyzer
> Tailored solution to your throughput need
> Eco-friendly - low water consumption

HumaStar 100 REF 16890 HumaStar 200 REF 16895


> Constant throughput of 100 tests per hour > Up to 200 tests per hour

Comprehensive features (DV\DQGHIŠFLHQW


> Less than 1L/h (HS100) or 2L/h (HS200) > Automatic pre- and post-dilution
> 80 reusable Bionex® cuvettes > Minimal water and energy consumption
> 8-step wash station > Minimal user maintenance
> Primary tubes and sample cups > Removable sample tray
> Reagent cooling > Choice of three different sample trays
> 30 reagent and 60 sample positions > Primary tubes up to 16 x 100 mm and sample cups
> Internal sample barcode reader > Removable reagent tray
> Needle shock detector > 50 ml or 20 ml reagent bottles available
> Capacitive liquid level detector > Printing on Windows compatible printer
> Large liquid containers with level sensors
> Method defined washing programms
> Windows 10®, USB compatible
> LIS via ethernet, ASTM, bidirectional Safety first
> Software designed for touch screen > Intelligent flagging system and extensive error log
> Continuous reagent cooling independent > Counter for components life cycle and maintenance
from main power switch > Two types of systemic and special washing solution
> Routine check and blank for each individual cuvette
> Validity limits for methods and
reactions programmable
> Reagent integrity check
> UPS 230V included in standard delivery

Clinical Chemistry Movie


User so
software – versatile and easy to use
> Software
Softwa designed for touchscreen use
> Intuitive
Intuiti user interface
> Numerous
Nume features to ease daily routine

Intelligent software design and architecture


> Smart graphical user interface for convenient operation Sample Tray
> Continuous loading of samples and reagents
> Random-access and STAT
> Free choice of execution order
> Extended walk-away capability
> Results archive with cumulative charts
> Programmable automatic start up routine
> Multiple work lists
> Multi-language software: English, French, Spanish
> Method and reagent monitor
(volumes, available tests, calibration, QC status)
Test Inspection
QC options
> Levey-Jennings plots and Westgard multi rules
> Up to 3 QC levels per test
> QC monitor and reports
> Method statistics: including test counter,
CV%, mean, graphical trend analysis

Calibration
> Automatic pre-dilution for calibrators
> Up to 8 calibrators per method
Quality Control
HumaStar 100 | 200
Technical data

Mode Random-access, STAT Pipetting Needle shock detector


Throughput HumaStar 100: Capacitive liquid level detector
100 t/h constant throughput Wash station 8-step cuvette wash station
HumaStar 200: Systemic and special washing solution
Up to 200 t/h throughput HumaStar 100:
Analysis Endpoint (bichromatic), 4 dispensing needles
Differential endpoint (with sample blank), Water consumption < 1 l/h (8 ml/test)
Fixed time, Kinetic (bichromatic), HumaStar 200:
Multi-standard (up to 8), 6 dispensing needles
factor, linear, non linear (cubic-spline, Water consumption < 2 l/h (8 ml/test)
poly-linear and logit-log four parameters) Optical system 9 discrete wavelengths (340, 405, 505, 546,
Samples Removable sample tray 578, 600, 650, 700 nm, one free position)
60 positions: primary tubes 12 – 12.5 x 100 mm Band pass: + /– 5 nm
and 10 mm cups Photometric linearity: 0 – 2.5 Abs
Optional: sample tray for 20 primary tubes Stability: < 1 % drift per day
12 – 16 x 100 mm and 20 cups 3.5 ml LIS Bi-directional, polling mode, ASTM, ethernet
Sample volume: 2 – 300 μl Usability Designed for touch screen (1280 x 1024 pixel)
Internal barcode reader Languages English, French, Spanish Software
Automatic pre- and post-dilution (other languages can be added)
  7HVWSURŠOHVDQGUHSOLFDWHV Printouts By patient, single test, complete sample,
Reagents Removable reagent tray work sheet, method and QCs,
30 reagent / diluent positions calibration curves, kinetics, continuous printing
50 and 20 ml bottles, adapter for tubes and cups Power 220 – 240 or 110 – 120 Vac, 50/60 Hz, < 200 VA
Reagent volumes: 5 – 350 μl Online UPS 230V included in Standard delivery
Refrigeration to ~ 9 °C below ambient Dimensions 69 x 76 x 52 cm (W x D x H)
Substrates, Enzymatic, Turbidimetric Weight 51 kg
Reaction Reaction volume: 210 – 350 μl Environment 16 – 30°C, humidity < 80 % non-condensing
80 reusable Bionex® cuvettes
6 mm optical path
Heat transfer by air