N
3000 4000 3000 3000 4000 3000
3000 4000 3000
A
NE
A
NE
W E
a
NE
S1
3000 BEDROOM 1 3000 a NE
3000
fg
S2
h
S
b
S1
3000 BEDROOM 2 3000 b 3000
LIVING ROOM
Se
tan
-C
ala
hij
GARAGE
bu
S3
13500 i 13500 an
13500 an Rochelle's Traveller's Inn
The Site Ro
c
S1
ad
3500 BATHROOM 3500 c f
3500
Producers Bank
j
e
S1
DINING PB
4000 4000 d 4000
CKT 3
MASTER'S e Pacific Gym and
BEDROOM PB Fitness Center
2
CKT 2
REF
d
S1
KITCHEN PB
CKT 4
3500 3500 3000 3500 3500 3000 OVERHEAD SERVICE ENTRANCE
3500 3500 3000
CONNECTED TO 230 AC,
SINGLE PHASE,2 WIRE,60Hz
VICINITY MAP
FLOOR PLAN LIGHTING LAYOUT POWER LAYOUT NOT TO SCALE KWHR METER
SCALE 1:100MM SCALE 1:100MM
SCALE 1:100MM
M G
8-14 mm² THHN.cu conductor as service
entrance in 35mmØ RSC/PVC and
60ATCB as main circuit protection
60AT MANUAL
TRANSFER SWITCH
SCHEDULE OF LOAD AND COMPUTATION
DETAILS - Panel board
NO. OF SIZE OF CIRCUIT
CKT NO. DESCRIPTION VOLTS VaS/VA AMPERE SIZE OF WIRE MAIN
FIXTURE CONDUIT PROTECTION Service Entrance
M KiloWatt-Hour Meter 60AT 15AT 2 LO
1 MAIN
Duplex Convenience
2 LIGHTING OUTLET (100VAs) 10 230 1000 4.3478 2 - 2.0mm² THHN cu. 20 mmØ 15ATCB Outlet 20AT 30AT
CO 3 4 REF
3 CONVENIENCE OUTLET (200VAs) 11 230 2200 9.5652 2 - 3.5mm² THHN cu. 20 mmØ 20ATCB Triplex Convenience
Outlet
4 REFRIGERATOR OUTLET 1 230 1840 8 2 - 5.5mm² THHN cu. 20 mmØ 30ATCB 5 SPARE SPARE 6
Lighting Panel Board
5 SPARE 1500 6.5217
6 SPARE 1500 6.5217 Power Panel Board
a
S1 One Gang Switch
Total 230 8040 34.9564
ab
S2 Two Gang Switch
S3
abc
Three Gang Switch RISER DIAGRAM
NOT TO SCALE
COMPUTATION: Ground
Circuit Breaker
FEEDER: LED light
G
Generator
TOTAL CURRENT + 25%(HIGHEST MOTOR LOAD) LEGENDS
NOT TO SCALE
GENERAL NOTES AND SPECIFICATION
= 34.9564+25%(8) 1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE PHILIPPINE ELECTRICAL
CODE (PEC), RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL
= 36.9564 AMPERES POWER AND TELEPHONE COMPANIES.
2. THE TYPE OF POWER SERVICE SHALL BE 2-WIRE, SINGLE PHASE, 230 VOLTS, 60 HERTZ.
USE: 8-14 mm² THHN.cu CONDUCTOR AS MAIN FEEDER IN 35mmØ RSC/PVC. 3. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE APPROVED TYPE FROM THE BUREAU OF STANDARDS FOR
LOCATIONS AND PURPOSES.
OVERCURRENT PROTECTION DEVICE: 4. STANDARD SIZES OF FITTINGS, BUSHINGS AND OTHER APPURTENANCES SHALL BE USED.
5. ADEQUATE PROTECTION AND GROUNDINGS SHALL BE PROVIDED FOR ALL REQUIREMENTS.
TOTAL CURRENT + 150%(HIGHEST MOTOR LOAD) 6. THE MINIMUM ALLOWABLE SIZE OF CONDUCTORS AND RACEWAYS OR CONDUIT SHALL BE 2.0 mm² COPPER WIRE AND
= 36.9564+150%(8) 20mmØ PVC OR RSC RESPECTIVELY.
= 48.9564 AMPERES 7. THE FOLLOWING MOUNTING SHALL BE OBSERVED AND FOLLOWED:
A. WALL SWITCHES MUST BE 1.2m FROM THE FINISHED FLOOR LINE.
B. CONVENIENCE OUTLET MUST BE 0.3m FROM FINISHED FLOOR LINE .
C. PANEL BOARD/DISTRIBUTION LOAD MUST BE CENTRALLY LOCATED BETWEEN THE FINISHED FLOOR LINE AND THE
UESE: 60ATCB, 2-POLE, 60Hz, BOLT-ON AS MAIN CIRCUIT PROTECTION CEILING LINE.
D. AIR CONDITIONING OUTLET MUST BE 1.6m ABOVE THE FINISHED FLOOR LINE.
E. ALL OTHER OUTLET MUST BE DETERMINED OR PRESCRIBED BY ELECTRICAL ENGINEER IN-CHARGE.
8. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY
ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.
SUBJECT SUBMITTED BY: PROJECT TITLE INSTRUCTOR REMARKS RATINGS SHEET NO.
ENGINEERING GROUP 6 FLOOR PLAN ENGR. JAY PEE NUÑEZ
UTILITIES 1 BSCE-3REQ SCALE 1:100MM