0% found this document useful (0 votes)
28 views2 pages

SF Ecp60

The ECP Series AC-DC power supply offers a low profile and compact design with a size of 4” x 2” and is suitable for IT and medical applications. It features dual and triple output options, high efficiency of 88%, and a peak load capability, along with a 3-year warranty. The power supply meets various safety and EMC standards, making it reliable for diverse operational environments.

Uploaded by

muhammad waseem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views2 pages

SF Ecp60

The ECP Series AC-DC power supply offers a low profile and compact design with a size of 4” x 2” and is suitable for IT and medical applications. It features dual and triple output options, high efficiency of 88%, and a peak load capability, along with a 3-year warranty. The power supply meets various safety and EMC standards, making it reliable for diverse operational environments.

Uploaded by

muhammad waseem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

60 Watts

AC-DC
xppower.com

ECP Series
• Low Profile Design

• Compact Size, 4” x 2”

• IT & Medical Approvals

• Dual and Triple Output

• <0.5 W No Load Input Power

• Peak Load Capability

• 3 Year Warranty

Specification
Input General
Input Voltage • 85-264 VAC, derate from 100% load at Efficiency • 88% typical at 230 VAC and full load
90 VAC to 90% load at 85 VAC Isolation • 4000 VAC Input to Output
Input Frequency • 47-63 Hz 1500 VAC Input to Ground
Input Current • 0.85 A max at 115 VAC 500 VDC Output to Ground
Inrush Current • 100 A max at 230 VAC, cold start at 25 °C Switching Frequency • 30-130 kHz variable
Power Factor • EN61000-3-2, class A MTBF • >400 kHrs to MIL-HDBK-217F
No Load Input Power • <0.5 W at 25 °C, GB
Earth Leakage Current • <250 μA at 264 VAC, 60 Hz
Input Protection • Internal T2 A/250 V fuse in both
Environmental
line and neutral Operating Temperature • -20 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Output Cooling • Natural convection
Output Voltage • See table Operating Humidity • 5% to 95% RH, non condensing
Output Voltage Trim • ±10% on V1 only, output 2 on multi output Operating Altitude • 3000 m max
models will track by the same percentage Storage Temperature • -40 °C to +85 °C
Minimum Load • 10% minimum load required on all Shock • 30 g pk, half sine, 6 axes
outputs of multi output models Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes
Start Up Delay • 1.3 s max
Start Up Rise Time • 15 ms typical EMC & Safety
Hold Up Time • 16 ms min at full load at 115 VAC Emissions • EN55011/32, level B conducted & level A
Total Regulation • Output 1: 2% from 0% load to 100% load radiated
Output 2: 5% from 20% load to 100% load Harmonic Currents • EN61000-3-2, class A
Output 3: 5% from 10% load to 100% load Voltage Flicker • EN61000-3-3
Transient Response • 4% max deviation, recovering to less than ESD Immunity • EN61000-4-2, ±4 kV indirect contact,
1% within 500 μs for 50% step load Perf Criteria A
change at 1 A/μs
Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A
Ripple & Noise • 1% pk-pk measured with 20 MHz
bandwidth EFT / Burst • EN61000-4-4, level 3 Perf Criteria A
Overvoltage Protection • 115-140% of nominal output voltage Surge • EN61000-4-5, level 2 Perf Criteria A
on V1 only, recycle input to reset Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A
Overload Protection • 120-160% of nominal power Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Short Circuit Protection • Trip and restart (hiccup mode)
EN60601-1-2, 30% 500 ms, 60% 100 ms,
Temperature • ±0.02%/°C max 100% 10 ms, 100% 5000 ms,
Coefficient Perf Criteria A, A, A, B
Safety Approvals • UL62368-1, IEC62368-1, EN62368-1,
ANSI/AAMI ES 60601-1, IEC60601-1,
EN60601-1, CE & UKCA meets all
applicable directives & legislation.
AC-DC
Models and Ratings ECP60
Output Output 1 Output 2 Output 3
Model Number
Power Voltage Current Peak(1) Voltage Current Peak(1) Voltage Current

60 W +5.0 VDC 7.0 A 9.1 A +12.0 VDC 3.0 A 3.90 A ECP60UD01

60 W +5.0 VDC 7.0 A 9.1 A +15.0 VDC 2.0 A 2.60 A ECP60UD02

60 W +5.0 VDC 7.0 A 9.1 A +24.0 VDC 1.5 A 1.95 A ECP60UD03

60 W +5.0 VDC 7.0 A 9.1 A +15.0 VDC 2.0 A 2.60 A -15.0 V 0.30 A ECP60UT02

60 W +5.0 VDC 7.0 A 9.1 A +24.0 VDC 1.5 A 1.95 A -12.0 V 0.30 A ECP60UT04

Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.

Mechanical Details

4.00 (101.6)

3.75 (95.2)
Voltage Adj.
CN1 - Input Connector
Pin 1 Neutral
Pin 2 Not Fitted 1
1 CN3
Pin 3 Line
CN2 6
Mates with JST housing 2.00
VHR-3N and JST Series (50.8) CN2
SVH-21T-P1.1 crimp terminals 6
1.75
3 1.75
Mounting holes marked with (44.4)
1 (44.4)
must be connected to safety earth CN1
1

CN2 Output Connector


UD/UT US05
0.13 ±0.01 (3.4 ±0.3)
UD/UT
Mounting hole need to be isolated from ground
Pin 1 V2
Pin 2 V1
Pin 3 V1
Pin 4 RTN
Pin 5 RTN 1.04 1.20
Pin 6 V3 (26.3) (30.4)
Mates with JST housing
VHR-6N and JST Series
SVH-21T-P1.1 crimp terminals

0.06 (1.6) 0.1 (2.5)

Notes
1. All dimensions are in inches (mm). 3. Tolerance: ±0.02 (±0.5) unless stated
2. Weight: 0.34 lbs (155 g) approx.

Derating Curve
100

80
Output Power (%)

60

40

20

0
-20 -10 0 10 20 30 40 50 60 70 80
Ambient Temperature (ºC)

05 Feb 2024