Installation Sheet                                                                                    NNZ3098401-01 / 02-33043-02-en, May 2021 | 1
SpaceLogic™ CRS-HH-REL-10
Expansion Module
Regulatory Compliance and Safety Information
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences arising out of the use of this material.
Carefully read these instructions and all information relevant for this product before trying to install it. See the list of technical literature.
The technical literature and declarations of conformity can be accessed on the Schneider Electric Exchange website, ecobuilding.schneider-
electric.com. Contact your local Schneider Electric sales office for a hard copy of the documentation or for additional information.
Technical Literature
• SpaceLogic Hardware Reference Guide, 04-XX001-XX-en
Dimensions
                                                                             Installing the Device on a DIN Rail
Installation Orientation Restrictions
                                                                                                       NOTICE
                                                                              EXPANSION MODULE DAMAGE
                                                                              Use the DIN rail end clip when you install the RP controller
                                                                              expansion module on a vertical DIN rail.
                                                                              Failure to follow these instructions can result in equipment
                                                                              damage.
                                                                                                NNZ3098401-01 / 02-33043-02-en, May 2021 | 2
Installing the Device on a Flat Surface
Connections
                                                                     DANGER
 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
 • Turn off all power connected to this equipment before working on the equipment.
 • More than one disconnect switch may be required to de-energize this equipment before servicing.
 Failure to follow these instructions will result in death or serious injury.
                                                                     DANGER
 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
 Do not connect high and low voltage next to each other for relay outputs.
 Failure to follow these instructions will result in death or serious injury.
To prevent from connecting high and low voltage next to each other, it is recommended not to mix high and low voltage connections on the
same side of the device. Connect the high voltage equipment on the upper (DO1-DO6) or lower (DO7-DO10) side and connect low voltage
equipment on the opposite side.
                                                                                                         NNZ3098401-01 / 02-33043-02-en, May 2021 | 3
Connections, continued
                                                                             NOTICE
 BLINDS/AWNINGS DAMAGE
 Before connecting the AC mains voltage to the blinds/awnings connected to the relay outputs, ensure that the CRS-HH-REL-10 relay
 module is powered up by the RP-C room bus (24 VDC).
 Failure to follow these instructions can result in equipment damage.
                                                                             NOTICE
 CONNECTOR OR CABLE ASSEMBLY DAMAGE
 Anchor the excess cabling to alleviate all stresses on connectors and cable assemblies.
 Failure to follow these instructions can result in equipment damage.
Wiring
Recommended screw tightening torques:
• 2-pole connector: 0.5 Nm (4.4 lbf.in)
• 9-pole connector: 0.2 Nm (1.7 lbf.in)
For information on wiring, see the SpaceLogic Hardware Reference Guide.
Part Numbers
Product                                                                                 Part number
CRS-HH-REL-10                                                                           SXWHHREL10001
Includes pluggable screw terminal blocks (10 x 2-pole, 2 x 9-pole connectors) for the
I/O, delivered in a plastic bag with the device.
DIN-rail end clip, 25 pieces                                                            SXWDINEND10001
                                                                                                                                    NNZ3098401-01 / 02-33043-02-en, May 2021 | 4
Specifications
DC input                                                        Pollution degree                                                Relay output rating
DC input supply voltage                                         2                                                               24 to 277 VAC     , 50/60 Hz / 30 VDC     ,
24 VDC                                                                                                                          Resistive and incandescent: 10 A
Powered by the RP-C through the room bus                        Mechanical                                                      Standard magnetic ballast: 5 A
(RJ45)                                                          Ingress protection rating                                       LED driver: 5 A
Maximum power consumption                                       IP 20                                                           1/2 HP, 240 VAC, 50/60 Hz
0.3 W                                                           Plastic flame rating                                            1/4 HP, 120 VAC, 50/60 Hz
                                                                UL94 V-0                                                        Maximum load current
Port types                                                      Plenum rating                                                   Maximum 50 A total load for the 10 outputs
Room bus                                                        UL 2043 (Approved for plenum installations)                     Maximum inrush current
RS-485                                                                                                                          Maximum 165 A inrush current (<20 ms) per
Dual RJ45 ports for daisy-chain                                 Relay outputs
                                                                                                                                output
configurations                                                  Outputs
                                                                                                                                Maximum 800 A inrush current (<200 µs) per
                                                                10, DO1 to DO10
                                                                                                                                output
Operation environment
Ambient temperature, operating                                                                                                  Digital inputs
0 to 50 °C (32 to 122 °F)                                                                                                       Inputs
Humidity                                                                                                                        12, DI1 to DI12
20 to 90 % RH non-condensing                                                                                                    Input rating
                                                                                                                                5 VDC       , 2.2 mA, SELV
Addendum - California Proposition 65 Warning Statement for California Residents
    WARNING: This product can expose you to chemicals including lead which is known to the State of California
to cause cancer and which is known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
© 2021 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
www.se.com/buildings