0% found this document useful (0 votes)
39 views4 pages

02 16005 22 en

The document provides installation instructions and safety information for the SpaceLogic TB-IO-W1 Terminal Base, emphasizing that only qualified personnel should handle the equipment. It includes details on compatible electronics modules, wiring specifications, and compliance with UL 864 requirements for smoke control applications. Additionally, it contains a warning regarding California Proposition 65 related to potential chemical exposure from the product.

Uploaded by

Aneta Deliu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views4 pages

02 16005 22 en

The document provides installation instructions and safety information for the SpaceLogic TB-IO-W1 Terminal Base, emphasizing that only qualified personnel should handle the equipment. It includes details on compatible electronics modules, wiring specifications, and compliance with UL 864 requirements for smoke control applications. Additionally, it contains a warning regarding California Proposition 65 related to potential chemical exposure from the product.

Uploaded by

Aneta Deliu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Installation Sheet 02-16005-22-en, May 2021 | 1

SpaceLogic™ TB-IO-W1
Terminal Base
Regulatory Compliance and Safety Information
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences arising out of the use of this material.
Carefully read these instructions and all information relevant for this product before trying to install it. See the list of technical literature.
The technical literature and declarations of conformity can be accessed on the Schneider Electric Exchange website, ecobuilding.schneider-
electric.com. Contact your local Schneider Electric sales office for a hard copy of the documentation or for additional information.

Technical Literature
• SpaceLogic Hardware Reference Guide, 04-XX001-XX-en
• EcoStruxure Building Management - Smoke Control System Design Guide, 04-16014-XX-en

Dimensions Overview

Connecting the Next Terminal Base


Installing the Terminal Base
WARNING
HAZARD OF ELECTRIC SHOCK OR EQUIPMENT DAMAGE
Ensure that the module type and the terminal base type match.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.

NOTE: Install the terminal base on a horizontal DIN rail. This


position provides proper cooling air flow through the electronics
module.

Terminal Base and Applicable Electronics Modules (-H indicates Override Switch)
Device Part number Device Part number

TB-IO-W1 Terminal Base SXWTBIOW110001 DO-FC-8 SXWDOC8XX10001

DI-16 SXWDI16XX10001 DO-FC-8-H SXWDOC8HX10001

UI-16 SXWUI16XX10001 AO-8 SXWAO8XXX10001

RTD-DI-16 SXWRTD16X10001 AO-8-H SXWAO8HXX10001

DO-FA-12 SXWDOA12X10001 AO-V-8 SXWAOV8XX10001

DO-FA-12-H SXWDOA12H10001 AO-V-8-H SXWAOV8HX10001


02-16005-22-en, May 2021 | 2

Terminal Base and Applicable Electronics Modules (-H indicates Override Switch), continued
Device Part number Device Part number

UI-8/DO-FC-4 SXWUI8D4X10001 UI-8/AO-V-4 SXWUI8V4X10001

UI-8/DO-FC-4-H SXWUI8D4H10001 UI-8/AO-V-4-H SXWUI8V4H10001

UI-8/AO-4 SXWUI8A4X10001

UI-8/AO-4-H SXWUI8A4H10001

I/O Bus Addressing, Power Limits, and Cables S-Cables


Device Part number

S-Cable, 1.5 m, angle SXWSCABLE10002

S-Cable, 0.75 m, angle SXWSCABLE10003

Smoke Control Application Note


All Universal Inputs (UI), Digital Inputs (DI), and Analog Outputs
(AO) are power-limited per UL 864 requirements. All Digital Output
(DO) relays are non-power-limited. For more information on the use
of the I/O modules for a UL 864 smoke control application, see the
latest version of the EcoStruxure Building Management - Smoke
Control System Design Guide (04-16014-XX-en).

Connections for I/O Modules


02-16005-22-en, May 2021 | 3

Connections for I/O Modules, continued

Wiring
Recommended screw tightening torque: 0.56 Nm (5 lbf.in)

Specifications
Operation environment Output rating UI-16 Module
Ambient temperature, operating 0 to 10 VDC , 0 to 20 mA DC input power
0 to 50 °C (32 to 122 °F) Channels 24 VDC , 1.8 W
Humidity 8 output Input rating
Maximum 95 % RH non-condensing 24 V, 2.4 mA
AO-V-8 (-H) Module Channels
Mechanical DC input power 16 input
Ingress protection rating 24 VDC , 0.7 W
IP 20 Output rating RTD-DI-16 Module
Plastic flame rating 0 to 10 VDC DC input power
UL94-5VB Channels 24 VDC , 1.6 W
8 output Input rating
Electrical 24 V, 2.4 mA
I/O bus power DI-16 Module Channels
24 VDC max. 30 W per I/O bus power DC input power 16 input
supply, Class 2 24 VDC , 1.6 W
Maximum addresses per I/O bus Input rating UI-8/DO-FC-4 (-H) Module
32 24 V, 2.4 mA DC input power
Channels 24 VDC , 1.9 W
AO-8 (-H) Module 16 input Relay contact rating
DC input power 250 VAC / 30 VDC ,3A
24 VDC , 4.9 W Pilot Duty (Power Factor 0.35)
02-16005-22-en, May 2021 | 4

Specifications, continued
Input rating UI-8/AO-V-4 (-H) Module Relay contact rating
24 V, 2.4 mA DC input power 250 VAC / 30 VDC ,2A
Channels 24 VDC , 1.0 W Pilot Duty (Power Factor 0.35)
4 output/8 input Output rating Channels
0 to 10 VDC 12 output
UI-8/AO-4 (-H) Module Input rating
DC input power 24 V, 2.4 mA DO-FC-8 (-H) Module
24 VDC , 3.2 W Channels DC input power
Output rating 4 output/8 input 24 VDC , 2.2 W
0 to 10 VDC , 0 to 20 mA Relay contact rating
Input rating DO-FA-12(-H) Module 250 VAC / 30 VDC ,3A
24 V, 2.4 mA DC input power Pilot Duty (Power Factor 0.35)
Channels 24 VDC , 1.8 W Channels
4 output/8 input 8 output

Addendum - California Proposition 65 Warning Statement for California Residents


WARNING: This product can expose you to chemicals including lead which is known to the State of California
to cause cancer and which is known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

© 2021 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
www.se.com/buildings