        3.     Cl No. 4.0 IP 55, PESO                                                                              YES
        4.     In Process Inspection CL No. 2.2 Assembled Motor                                                    YES
  E1 – Details of Witness (W) & Hold (H) Inspection Points
    MQP POINT                                                                                               INSPECTION POINT
                                             ACTIVITY DESCRIPTION
       No.                                                                                               (Hold / Witness / Review)
   Cl No.3.1.A.a      Resistance of Stator Winding, Check and found OK                                             Witness
                      Space Heater Resistance, IR (Before & After) & HV Tests, Check
   Cl No.3.1.A.b
                      and found OK
                                                                                                              Not Applicable
   Cl No.3.1.A.c      RTB(N/A), BTD(N/A), Thermister resistance Check and found OK                            Not Applicable
   Cl No.3.1.A.d      Insulation Resistance Before & After HV, Check and found OK                                Witness
   Cl No.3.1.A.e      HV Test, Check and found OK                                                                Witness
   Cl No.3.1.A.f      No Load Tests at Rated Voltage, Check and found OK                                         Witness
   Cl No.3.1.A.g      Reduced voltage running at No load, Check and found OK                                     Witness
   Cl No.3.1.A.h      Vibration Measurement on No Load, Check and found OK                                       Witness
   Cl No.3.1.A.i      Locked Rotor Tests at reduced Voltage, Check and found OK                                  Witness
   Cl No.3.1.A.j      Noise Level Measurement on No Load, Check and found OK                                     Witness
   Cl No.3.1.B.1      Name Plate Verification, Check and found OK                                                Witness
   Cl No.3.1.B.2      Dimension Check (Mounting Dimensions), Check and found OK                                  Witness
    Cl No.3.2.j       Dimension Check (Shaft), Check and found OK                                                Witness
    Cl No.3.2.k       Dimension Check (Centre height), Check and found OK                                        Witness
    Cl No.2.3.a       Painting: Paint Shade, Check and found OK                                                  Review
    Cl No.2.3.b       Painting: Paint Thickness, Check and found OK                                              Review
     Cl No.3.2        Type Test Report.                                                                          Review
    Cl No.4.0.a       Test for Degree of Protection of encloser (IP 55).                                         Review
  E2 – Details of Monitoring and Surveillance Patrols                                            Tick if conducted during the visit
  N/A
  E3 – Details of Certificates Review                                                          Tick if conducted during the visit
      The following documents reviewed are listed below.
      1. IP 55 Report
      2. Calibration Status.
      3. PESO Certificate.
  DISCLAIMER
   BVIL has only verified the technical content during the certificate review of bought out item(s) and is not
   accountable for any compliance with lab traceability to ISO/IEC 17025 or NABL Accredited laboratory.
  E4 – Problem Pending / Area of Concern
  N/A
  E5 – Manufacturing Process Status
  Manufacturing process completed, offered lot shown in final condition.