Job Card: 26-23-00-710-801-A - Operational Check of Firing-Circuit Continuity
Job Card: 26-23-00-710-801-A - Operational Check of Firing-Circuit Continuity
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
CARD: ZONE: 130 INTERVAL:
SKILL: ACCESS: 821, 132WW, 132SW
MECH. INSP.
** ON A/C ALL
TASK 26-23-00-710-801-A
Operational Check of Firing-Circuit Continuity
REFERENCE QTYDESIGNATION
No specific 1 ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific 1 BOOMSET 600 OHMS
No specific AR CAP - BLANKING
No specific 1 HEADSET 600 OHMS
No specific AR SAFETY CLIP - CIRCUIT BREAKER
No specific 1 TOOL-TEST
(324477) AR CAP,PROTECTIVE-FIRE EXTINGUISHER SYSTEM
** ON A/C 201-300
132SW
** ON A/C ALL
C. Referenced Information
REFERENCE DESIGNATION
(Ref. 20-15-00-912-801-A). Handling Precautions for Electrostatic Discharge
Sensitive Devices
(Ref. 24-41-00-861-801-A). Energize the Aircraft Electrical Circuits from the External
Power A
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the APU
01). (APU Started with APU BAT)
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the External
03). Power A and B
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
REFERENCE DESIGNATION
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the APU
04). (APU started with External power A)
(Ref. 24-41-00-861-801-A- Energize the Aircraft Electrical Circuits from the External
05). Power B
(Ref. 24-41-00-862-801-A). De-energize the Aircraft Electrical Circuits from the
External Power A
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the APU
01).
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the
03). External Power A and B
(Ref. 24-41-00-862-801-A- De-energize the Aircraft Electrical Circuits from the
04). External Power B
(Ref. 25-52-00-000-801-A). Removal of the Ceiling Panels, the Partition Panels and
the Sidewall Panels in the Forward Cargo Compartment
(Ref. 25-52-00-400-801-A). Installation of the Ceiling Panels, the Partition Panels and
the Sidewall Panels in the Forward Cargo Compartment
** ON A/C 201-300
(Ref. 26-10-00-860-801-A). Energize the CIDS Smoke Detection Function (SDF)
** ON A/C ALL
(Ref. 26-16-00-710-803-A). Operational Check of the Lower-Deck Cargo-
Compartment and the Avionics-Compartment Smoke
Detection by PTT
(Ref. 52-30-00-010-801-A). Opening of the FWD and Aft Cargo-Compartment Doors
with the Yellow Electric Pump
(Ref. 52-30-00-410-801-A). Closing of the FWD and Aft Cargo-Compartment Doors
with the Yellow Electric Pump
Test Tool SHEET 1
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
30 OHMS
50W
PIN 1 +-
PIN 3
28VDC
< 2W
/
V
+-
PIN 2
PIN 4
PIN CONNECTOR
NO SPECIFIED LINK
F_MM_262300_5_T00L_01_01
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
3. Job Set-up
** ON A/C 201-300
Subtask 26-23-00-861-050-B
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-801) .
(2) Make sure that the Smoke Detection Function (SDF) is energized
(Ref. AMM TASK 26-10-00-860-801) .
** ON A/C ALL
Subtask 26-23-00-865-055-A
B. Get access to the avionics compartment. Then open, safety and tag this(these) circuit
breaker(s):
** ON A/C 201-300
722VU SMK CAN B&D 106WH T33
722VU SDF/DIR2 104WH T32
722VU SDF/DIR1 102WH T31
742VU SMK CAN A&C 105WH F80
742VU SDF/DIR2 103WH F79
742VU SDF/DIR1 101WH F78
742VU CRG FIRE EXTNG/A 101WX F77
Subtask 26-23-00-010-052-A
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the
forward cargo-compartment door 821.
(2) Open the forward cargo-compartment door 821 (Ref. AMM TASK 52-30-00-010-
801) .
(3) In the forward cargo compartment, on service panel 5022VE, set the "CARGO
COMPT LIGHT" switch to the "ON" position.
(4) Remove the sidewall panel 132SW (Ref. AMM TASK 25-52-00-000-801) .
Subtask 26-23-00-020-052-E
D. Preparation for Test
NOTE: For this test procedure, we recommend that a minimum of two persons can
speak to each other through the service interphone system. One person must
monitor the cockpit CARGO SMOKE panel 212VU, the other person must be
at Zone 132.
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
(1) On the CAPT jack panel, connect the HEADSET 600 OHMS to the related
connector.
(2) On the overhead panel 285VU, make sure that the ON legend on the SVCE INT
OVRD pushbutton switch 15RJ is off.
(3) In Zone 132, connect the BOOMSET 600 OHMS to the service interphone jack.
(4) At the fire extinguisher bottles:
(a) Do the procedure for electrostatic discharge sensitive-devices:
WARNING:
DO NOT TOUCH THE CARTRIDGE BEFORE YOU DO
THE PROCEDURE APPLICABLE TO DEVICES THAT
ARE SENSITIVE TO ELECTROSTATIC DISCHARGE.
ELECTROSTATIC DISCHARGE CAN CAUSE THE FIRE
EXTINGUISHER BOTTLE TO RELEASE ITS CONTENT
SUDDENLY AND CAUSE INJURY TO PERSONS.
1 Before you touch the cartridges, do the procedure for devices that are
sensitive to electrostatic discharge (Ref. AMM TASK 20-15-00-912-
801) .
(b) At the cartridges of the fire extinguisher bottles:
WARNING:
BEFORE YOU TOUCH THE POWER DEVICE CARTRIDGE,
MAKE SURE THAT YOU ARE GROUNDED AND THAT YOU
INSTALL A SHUNT DEVICE ON IT. USE A CAP OR PLUG
AS SHUNT DEVICE (THE CAP OR PLUG WILL SHUNT THE
PINS TOGETHER ON THE CARTRIDGE). DO NOT USE A FOIL
SHUNT.
IF YOU TOUCH A POWER DEVICE CARTRIDGE THAT DOES
NOT HAVE A SHUNT DEVICE INSTALLED, AN EXPLOSION
CAN OCCUR AND CAUSE INJURIES TO YOU.
** ON A/C ALL
Subtask 26-23-00-865-056-A
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
** ON A/C 201-300
742VU CRG FIRE EXTNG/A 101WX F77
** ON A/C ALL
4. Procedure
** ON A/C 201-300
Subtask 26-23-00-710-050-V
A. Operational Test of the Firing Circuit Continuity
WARNING:MAKE SURE THAT YOU ARE GROUNDED AND THAT THE SHUNT
DEVICE IS INSTALLED ON THE ELECTRICAL CONNECTOR OF THE
CARTRIDGE. DO NOT USE A FOIL SHUNT. IF THE SHUNT DEVICE IS
NOT INSTALLED, THERE IS A RISK OF AN ACCIDENTAL EXPLOSION
OF THE CARTRIDGE. THIS CAN CAUSE INJURY TO PERSONS.
(1) Wait 3 minutes to make sure that the system is correctly booted.
(2) Do the test procedure:
ACTION RESULT
1.On the electrical connector 4003WX-
C:
· Remove the blanking cap and
connect the TOOL-TEST.
2.On the test tool:
· Select pin 1 and 2. In the cargo compartment, on the test
tool:
· The lamp is off.
· The indication on the ammeter is less
than 5 mA.
· The indication on the voltmeter is less
than 1 VDC.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 7 of 15
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:32
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 262300-01
JAI - A330 AMM TASK : 26-23-00-710-801-A
26-23-00 PB 501
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 8 of 15
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:32
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 262300-01
JAI - A330 AMM TASK : 26-23-00-710-801-A
26-23-00 PB 501
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
DO NOT CONNECT THE
CONNECTOR TO THE
CARTRIDGE BEFORE THE
TEST IS COMPLETED. IF
YOU OPERATE THE FIRE
EXTINGUISHING SWITCH
WHILE THE CONNECTOR
IS CONNECTED, YOU WILL
CAUSE A DISCHARGE OF THE
FIRE EXTINGUISHER BOTTLE
TO OCCUR.
CAUTION:
DO NOT CONNECT THE
CONNECTOR TO THE
CARTRIDGE BEFORE THE
TEST IS COMPLETED. IF
YOU OPERATE THE FIRE
EXTINGUISHING SWITCH
WHILE THE CONNECTOR
IS CONNECTED, YOU WILL
CAUSE A DISCHARGE OF THE
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
FIRE EXTINGUISHER BOTTLE
TO OCCUR.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
JCP Title: C-CHECK CERTIFICATE OF TASK / INSPECTION COMPLETION: Page 11 of 15
JCP Ref: C-CHECK DATABASE REV DATE: Apr 01/2017
CERTIFIES THAT THE TASK / INSPECTION HAS BEEN COMPLETED TO THE REQUIRED PRINT DATE: Apr 06/2017 09:32
STANDARD AND SUPPORTS THE FINAL MAINTENANCE RELEASE / CERTIFICATE OF RELEASE
TO SERVICE
JOB CARD MPD-TASK: 262300-01
JAI - A330 AMM TASK : 26-23-00-710-801-A
26-23-00 PB 501
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
CAUTION:
BEFORE YOU USE THE
TEST TOOL, MAKE SURE
THAT EACH MULTIMETER IS
CORRECTLY SET FOR THE
NEXT STEP. FOR THAT STEP,
MAKE SURE THAT:
- THE AMPERE RANGE ON
EACH MULTIMETER IS
CORRECT
- THE VOLTAGE RANGE
ON EACH MULTIMETER IS
CORRECT.
IF THESE RANGES ARE NOT
CORRECTLY SET BEFORE
YOU USE THE TEST TOOL,
YOU CAN CAUSE DAMAGE TO
THE MULTIMETERS.
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
ACTION RESULT
13.Do the step 10. thru 12. again for pin
3 and 4.
14.Disconnect the TOOL-TEST.
CAUTION:
DO NOT CONNECT THE
CONNECTOR TO THE
CARTRIDGE BEFORE THE
TEST IS COMPLETED. IF
YOU OPERATE THE FIRE
EXTINGUISHING SWITCH
WHILE THE CONNECTOR
IS CONNECTED, YOU WILL
CAUSE A DISCHARGE OF THE
FIRE EXTINGUISHER BOTTLE
TO OCCUR.
CAUTION:
DO NOT CONNECT THE
CONNECTOR TO THE
CARTRIDGE BEFORE THE
TEST IS COMPLETED. IF
YOU OPERATE THE FIRE
EXTINGUISHING SWITCH
WHILE THE CONNECTOR
IS CONNECTED, YOU WILL
CAUSE A DISCHARGE OF THE
FIRE EXTINGUISHER BOTTLE
TO OCCUR.
** ON A/C ALL
Subtask 26-23-00-865-111-A
B. Get access to the avionics compartment. Then open, safety and tag this(these) circuit
breaker(s):
** ON A/C 201-300
742VU CRG FIRE EXTNG/A 101WX F77
Subtask 26-23-00-420-065-A
C. After the Test Procedure
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
(1) Before you touch the cartridge do the procedure for devices that are sensitive for
electrostatic discharge (Ref. AMM TASK 20-15-00-912-801) .
(2) Connect the electrical connectors:
WARNING:MAKE SURE THAT YOU ARE GROUNDED AND THAT THE SHUNT
DEVICE IS INSTALLED ON THE ELECTRICAL CONNECTOR
OF THE CARTRIDGE. DO NOT USE A FOIL SHUNT. IF THE
SHUNT DEVICE IS NOT INSTALLED, THERE IS A RISK OF AN
ACCIDENTAL EXPLOSION OF THE CARTRIDGE. THIS CAN
CAUSE INJURY TO PERSONS.
** ON A/C ALL
Subtask 26-23-00-865-112-A
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
** ON A/C 201-300
722VU SMK CAN B&D 106WH T33
722VU SDF/DIR2 104WH T32
722VU SDF/DIR1 102WH T31
742VU SMK CAN A&C 105WH F80
742VU SDF/DIR2 103WH F79
TITLE:
A/C Reg.: 26-23-00-710-801-A - Operational
VT-JWR Check of Firing-Circuit Continuity
MECH. INSP.
** ON A/C ALL
Subtask 26-23-00-710-059-A
E. Tests
(1) Wait 3 minutes to make sure that the system is correctly booted.
(2) Do the operational check of cargo compartment smoke detection
(Ref. AMM TASK 26-16-00-710-803) .
5. Close-up
** ON A/C 201-300
Subtask 26-23-00-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the sidewall panel 132SW (Ref. AMM TASK 25-52-00-400-801) .
(3) In the forward cargo compartment, on service panel 5022VE, set the "CARGO
COMPT LIGHT" switch to the "OFF" position.
(4) Close the forward cargo-compartment door 821 (Ref. AMM TASK 52-30-00-410-
801) .
(5) Remove the ground support and maintenance equipment, the special and
standard tools and all other items.
(6) Remove the access platform(s).
** ON A/C ALL
Subtask 26-23-00-862-052-A
B. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-801) .
*** END OF CARD ***